Alaris / Asena GS, GH, CC, TIVA, PK, Enteral Syringe Pump

Similar documents
Name: Oxygen Care Ltd Address: 2 Holfeld Business Park, Kilmacanogue, Co. Wicklow, Ireland URGENT FIELD SAFETY NOTICE - UPDATE

Urgent Medical Device Recall Medtronic StrataMR Adjustable Valves & Shunts

Balloon Gastrostomy (BG) Tube

Kimal plc: URGENT FIELD SAFETY NOTICE Field Safety Corrective Action IMMEDIATE ACTION REQUIRED

Urgent Field Safety Notice (Field Safety Corrective Action) for CORAIL AMT Neck Trials Surgical Instruments

CONTRACTOR SAFETY INDUCTION HANDBOOK

Model: 43T. Bermad Pressure Relief Valve

HYGIENIC SIGHT FLOW INDICATORS

Patients Guide for Self Administering Intravenous Antibiotics General points

Domiciliary Oxygen Switch. Instructions for Use

Contents. 6. Infusion Mode...10

Operating instructions - Translation of the original -

Exeter Clinical and Health Research

URGENT MEDICAL DEVICE RECALL NOTICE

MoveRoll Conveyor Operating and Maintenance Manual

Approved by Principal Investigator Date: Approved by Super User: Date:

Pressure maintenance valve SDV-P / SDV-P-E

THE UNIVENTOR 400 ANAESTHESIA UNIT

Blood Pressure Monitoring: Arterial Line

INSTALLATION, OPERATING & MAINTENANCE MANUAL WATER DRAIN VALVE

6900 Maintenance Instruction System Flush

BPS-2, Rev TABLE OF CONTENTS

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings

The University of Georgia Automated External Defibrillator (AED) Program Guidelines

UNITY 2. Uni-DAAMS Manual. Version 1.3 (Changes to Section 1.1) March 2010

URGENT Medical Device Recall

Operating Instructions Foreline Trap Right Angle and Inline

Approved by BNC Managing Director Paul Lum Date: Approved by PI (s) /Super User (s): _Peter Hosemann/Andy Minor_Date:

LIFT MAINTENANCE POLICY

TECHNICAL DATA. Q = C v P S

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

KMB 18/28 (BANDMASK) OVERHAUL, MAINTENANCE, AND INSPECTION CHECKLIST APPENDIX A

Repair instructions. Pivot bushing replacement. XL-AS10001RM-en-DE Rev B

March 2018 FSN Medical Device Recall/Notification HeartStart FRx, HeartStart Home, and Heartstart OnSite AEDs

6800 Maintenance Instruction System Flush Procedure

S&S. Installation Instructions: S&S Stealth Air Cleaner Kit for Harley-Davidison Models With Stock Cable Operated Delphi EFI

OWNER S MANUAL. Read the instructions and warnings in this manual carefully before using this firearm; do not discard this manual.

1.0 - OPENING AND CLOSING THE DOOR

The safe use of infusion devices

WELLS JOHNSON HIGH VOLUME CANISTERS

Please visit our website at and leave your comments.

TOCA MAINTENANCE & TROUBLESHOOTING MANUAL

OWNER S TECHNICAL MANUAL

3 Post Pressure Fit System Owner s Manual

AQUADEX FLEXFLOW SYSTEM QUICK REFERENCE GUIDE

Instruction Manual. Standard Surge Eliminator. Standard X. Flushable X - X

ROTATING DISK VALVES INSTALLATION AND MAINTENANCE 1. SCOPE 3 2. INFORMATION ON USAGE 3 3. VALVE TYPES 3 4. OPERATORS 5 5. VALVE CONSTRUCTION 6

Introduction and instructions for use

SC505 Sof Care Inflator. Operating Instructions and Service Manual

GM/GN2646. Guidance on Axle Bearing Maintenance. Issue One: March 2011 Rail Industry Guidance Note for GM/RT2004 Issue Four

UsER manual for Watersens ph -REDOX

Abdominal Aortic Aneurysm (AAA) Repair Trainer User Guide

641/01 AVK SWING CHECK VALVE OPERATION & MAINTENANCE MANUAL. AVK UK Limited OM270710

The Univentor 1250 Anaesthesia Unit

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &

Pressure Fit System - Two Post Version Owner s Manual

LIQUIP DRYBREAK COUPLER. LYNX Series MAINTENANCE INSTRUCTIONS

TECHNICAL DATA. Q = C v P S

LIQUIP DRYBREAK COUPLER. API800 Series MAINTENANCE INSTRUCTIONS

Name of product: Gripper for vertical façade FTV panels Types: PVF (60, 80, 100, 120, 133, 150, 172, 200 and 240 mm) INSTRUCTIONS FOR USE

TECHNICAL DATA. Q = C v P S

HONG KONG COLLEGE OF ANAESTHESIOLOGISTS TECHNICAL GUIDINES RECOMMENDATIONS ON CHECKING ANAESTHESIA DELIVERY SYSTEMS

Squeegee Unit for MRS Multi-Recovery System

Introduction. Medley TM Medication Safety System. Alaris Medical Systems

T i m i n g S y s t e m s. RACEAMERICA, Inc. P.O. Box 3469 Santa Clara, CA (408)

Instructions for Use

4 ANGLE GRINDER MODEL NO: CAT 52 PART

User Manual. MEGP 25 Electric Gripper. Document version: 1.1

MARINE NOTICE MARINE NOTICE. Marine Notice 11/2012 Supersedes 15/2010 and 7/2012. Guidance on ECDIS for ships calling at Australian ports 11/2012

Standard. Abdominal Aortic Aneurysm (AAA) Repair Trainer. Part No: 60610

TECHNICAL DATA. Q = C v P S

SEries 29 Hydrant valves installation, operation & maintenance manual

Installation/Care/Use Manual

FLANGED TWO-PIECE BALL VALVES

Alaris Syringe Pump (with Plus Software) MK3

Alaris CC Syringe Pump

Port - Body in a Box User s Manual

MANUAL SEALLESS STEEL STRAPPING TOOL MODEL A

Microfluidic Demonstration

FLANGED TWO-PIECE BALL VALVES

Overview. VARICOVER product recovery systems. Special features. Recover the value, reduce the waste! Design with no dead-zones.

MEDICAL REGULATIONS MEDICAL REGULATIONS

Index Table. Model 794. Installation, Operating and Maintenance Instructions

COUNTER CURRENT UNIT. Instruction Manual

Un-Pressurized Orefice Fittings FIO EZ. Parts List and Operation Instructions TECHNICAL MANUAL. Dn 2-6 Class Lbs

OPERATION AND MAINTENANCE MANUAL

7130 Lancer Rear Drive Magnetic Commercial Indoor Cycling Bike

TAMPERS WARNING NOTICE. Reliable s REL-TMP Series makes quick work of setting poles, asphalt patch and general construction backfill compacting.

Syringe, Distribution Valve and Infusion Pump Removal/Replacement ATTENTION SYRINGE REPLACEMENT

Asena PK Syringe Pump. Directions for Use ENGLISH. 1000PB01489 Issue 4

OFFICINE OROBICHE S.p.A. 1/9

Installation Instructions, Pressure Regulator Series

Agilent 1290 Infinity Pump Head Maintenance

TECHNICAL DATA. Q = C v P S

Shut-Off Valves and Valve Boxes

USING HAZOP TO IDENTIFY AND MINIMISE HUMAN ERRORS IN OPERATING PROCESS PLANT

MANITOBA RENAL PROGRAM

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

Instruction Manual. AlfaLavalSBAntiVacuumValve ESE02960-EN Original manual

Recommendations on Checking Anaesthesia Delivery Systems

Transcription:

Name Address Product Name: URGENT FIELD SAFETY NOTICE Alaris / Asena GS, GH, CC, TIVA, PK, Enteral Syringe Pump Product codes with prefix (all variants): 8001, 8002, 8003, 8004, 8005, 8007 FSCA Identifier: RA-2018-03-01 Date: June 2018 Type of Action: Field Safety Notice ATTENTION: Clinical Personnel, Risk Managers, Biomedical Personnel Dear valued customer, BD continuously strives to improve our product s performance and quality, with safety at the forefront of product development. BD is undertaking a corrective action on its Alaris / Asena syringe pumps to replace the existing gripper plate actuating spring (S5) design with a new improved design, which is located on the back-plate of the syringe plunger holder as shown in Figure 1 A) and B). This is being undertaken to improve performance and reliability of the S5 spring to reduce the risk of harm to patients. This corrective action supersedes the Alaris / Asena syringe pump S5 spring replacement, FSN RA-2017-02-02, issued in March 2017. Description of the Problem The S5 spring is located on the back-plate of the syringe plunger holder and ensures that the syringe plunger flange sits tightly between the positive plunger gripper and the backplate. BD has identified that the gripper plate actuating spring (S5), can break and may prevent the gripper fingers from securing the syringe plunger within the plunger holder mechanism which causes a small gap between the syringe plunger flange and the syringe drive mechanism. See Figure 1. 1000RA00340 Page 1 of 8

Positive Plunger Grippers Finger Grippers Syringe Plunger Flange A) B) Figure 1: Backplate and S5 spring location on an Alaris syringe pump. A) New spring (SKU 1000ME02157) B) New backplate (SKU 1000SP02113). In some circumstances the gap between the syringe plunger flange and back-plate may result in a clinically significant over infusion. Neonatal and paediatric patients, or those receiving critical drugs, at low infusion rates, would be considered to be the most at risk if small volumes of fluids reach the patient due to siphoning. Specifically, the gap between the syringe plunger flange and back-plate may lead to the following hazardous situations: 1. Over infusion due to syringe siphoning of <1mL (0.37ml for 5mL syringes to 0.87ml for 50mL syringes) volume of fluid. 2. Delayed start of infusion when the system detects the syringe plunger flange is not in contact with the back-plate and will generate a Check Syringe alarm. 1000RA00340 Page 2 of 8

In addition, trouble-shooting of the CHECK SYRINGE alarm may result in the following use errors: 1. Continued use after receiving CHECK SYRINGE alarm without determining cause is contrary to the syringe pump Directions for Use (DFU). The DFU instructs users to remove the pump from clinical use and have it examined by Qualified Service Personnel in accordance with the TSM if there is no identifiable cause for the CHECK SYRINGE alarm(s). 2. While trouble shooting the CHECK SYRINGE alarm, the user may push the plunger holder against the plunger without first closing the in-line clamp. If the tubing is attached to a patient, unintended boluses and over infusion may result. Alarms and Warnings in the Directions for Use (DFU) Users should be aware of the alarms and warnings highlighted in the new version of the Alaris syringe pump DFU, which provides clarification of what a Check Syringe alarm indicates and the actions to be taken as a result: A Check Syringe alarm may indicate the incorrect size of syringe has been fitted; the syringe has not been positioned correctly, or has been disturbed during operation (for example, the user opens the syringe clamp, or if the syringe plunger loses contact with the plunger button). If there is no identifiable cause for the Check Syringe alarm(s) then the pump should be removed from clinical use and examined by qualified service personnel in accordance with the Alaris Syringe Pump Technical Service Manual. Following feedback from the market, additional information regarding siphonage has been added to the DFU which the user should consider: When more than one pump is being used on a patient, those containing high risk, critical medications must be positioned as close to the patient's heart level as possible to avoid the risk of variations in flow or siphoning. Further information relating to the positioning of the pump has been added in the Syringe Loading section of the new DFU. Please note: The latest updated version of the DFU will be available on the BD website www.bd.com/int-alaris-technical by 29th June 2018 1000RA00340 Page 3 of 8

Action Required 1) Please acknowledge receipt of this Field Safety Notice (FSN) by completing and returning the Acknowledgement Form (Appendix I). Using the Acknowledgement Form, please confirm your preferred option for remediation. Please note that if you choose option 2 below, the FSCA acknowledgement form needs to be returned to BD prior to ordering the backplate assembly part number SKU 1000SP02113. a. OPTION 1: BD to carry out the backplate assembly replacement. If you wish BD to provide this replacement service, please contact your local BD representative as soon as possible to make necessary arrangements. The highest priority should be given to clinical areas such as neonatal, pediatric and critical care areas, where critical drugs are delivered at lower infusion rates. b. OPTION 2: The customer to carry out the backplate assembly replacement. If you wish to perform the replacement yourself, please follow the backplate assembly replacement instructions accompanying this FSN (Appendix II). In this scenario, please contact your local BD representative to order the correct quantity of replacement backplate assemblies. The highest priority should be given to clinical areas such as neonatal, pediatric and critical care areas, where critical drugs are delivered at lower infusion rates. 2) Before starting the backplate replacement activity as per this Field Safety Notice, please ensure that you scrap locally any spare parts or kits that include old backplates and the previous design of the S5 spring as per your internal procedures. Please note: The action to replace the Alaris / Asena syringe pump S5 spring under this Field Safety Notice supersedes the S5 spring replacement under the Field Safety Notice RA-2017-02-02 issued in March 2017. Therefore the actions required under this Field Safety Notice should be carried out as soon as reasonably possible. 1000RA00340 Page 4 of 8

Preventative Maintenance and Correction It is highly recommended that routine preventative maintenance is carried out as per the Technical Service Manual. Preventative maintenance inspections should be performed at least every three years as detailed in the Technical Service Manual. Please note: The Technical Service Manual has been updated to include the new backplate replacement instructions for routine preventative maintenance. The latest updated version of the Technical Service Manual is located on the BD.com website, which can be found at www.bd.com/int-alaris-technical. Additionally, you can find the instructions on backplate replacement in Appendix II of this Field Safety Notice. Transmission of this Field Safety Notice Please distribute this notice to all those who need to be aware of this action within your organisation. If you are no longer in possession of the Alaris / Asena syringe pumps included in this Field Safety Notice, please pass this notice and all the related documentation on to the current user(s). Your competent authority/regulatory agency has already been notified of this Field Safety Notice by BD. Should you have any questions or require assistance relating to this Field Safety Notice, please contact your local BD representative. We sincerely apologise for any inconvenience this action may have caused you or your staff. Sincerely, 1000RA00340 Page 5 of 8

Appendix 1 To be completed and returned by End User Product Name: URGENT FIELD SAFETY NOTICE Acknowledgement Form Alaris / Asena GS, GH, CC, TIVA, PK, Enteral Syringe Pump Product codes with prefix (all variants):8001, 8002, 8003, 8004, 8005, 8007 FSCA Identifier: RA-2018-03-01 Date: June 2018 Type of Action: Name of Hospital / Facility Hospital / Facility Address Field Safety Notice Telephone Number Name Signature Date Please confirm the following by checking the box: I have read and understood the contents of this Field Safety Notice If your facility does not have any affected syringe pumps listed in this Field Safety Notice, please confirm the following by checking the box: I confirm that our facility does not have any of the affected syringe pumps listed in this Field Safety Notice. Please pass this notice and all the related documentation on to the current user if applicable. If your facility has any of the affected syringe pumps listed in this Field Safety Notice, please complete Sections A, B and C below: Section A: Please confirm both actions by checking the boxes I will distribute this Field Safety Notice to all those who need to be made aware. 1000RA00340 Page 6 of 8

I have scrapped spare parts or kits that include backplate and previous design of S5 spring, following local procedure. Section B: Please confirm one of the following options: BD to carry out the backplate assembly replacement. I will contact my local BD representative to make necessary arrangements. The customer facility will carry out the backplate assembly replacement. I confirm to bear the responsibility of correcting all the pumps in my possession as described in this Field Safety Notice. I will follow the backplate assembly replacement instructions in Appendix II. I will contact my local BD representative to order the correct quantity of replacement backplate assemblies. Section C: To assist us to reconcile the models and numbers of syringe pumps at your facility, please provide the information below: Syringe Pump Model Alaris / Asena GS Alaris / Asena GH Alaris / Asena CC Alaris / Asena TIVA Alaris / Asena PK Alaris / Asena Enteral Syringe Pump Number of syringe pumps Please return your completed Acknowledgement Form to: Local BD representative Address: Or preferred option; please scan the Acknowledgement Form and send via email to: country specific inbox 1000RA00340 Page 7 of 8

Appendix II Plunger Backplate Replacement for RA-2018-03-01 When receiving the new backplate please follow the instructions below which outlines the method for replacing the backplate assembly. See below for spring identification. New Backplate Old Backplate For further information, please contact your local BD representative. A Plunger Back Plate Assembly Kit is available, part number 1000SP02113. 1. Remove three screws holding plunger backplate. 2. Remove the plunger backplate. Note: Be cautious when removing as parts may become loose. Placing the Pump in a vertical orientation may assist with maintaining components in place. 3. Visually inspect the interior of the plunger, follow the Technical Service Manual Corrective Maintenance for further details. 4. Refit the replacement plunger backplate assembly. 5. Fit the three screws into the plunger backplate. Make sure the backplate assembly is secure. 6. Discard the old backplate assembly following local procedure. 1000RA00340 Page 8 of 8