Oxygen Sensor with Electrode

Similar documents
The Oxygen Sensor can be connected to all types of einstein Tablets, einstein LabMate, and einstein LabMate +.

Pressure Sensor 150 to 1150 mbar Product Number: ENPRS015

Measuring wind speed and direction

Flow Rate Sensor Product Number: ENFLO-A254A

NEULOG OXYGEN LOGGER SENSOR GUIDE

PRODUCT SHEET. Order probe only as RXPROBE02

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

DOscan10 Pocket Dissolved Oxygen Tester Instruction Manual

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

DISSOLVED OXYGEN SENSOR BT34i

Introduction The Smart Q Oxygen Adaptor enables an Oxygen electrode to be connected to an EasySense unit.

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

Dissolved Oxygen/Temp Waterproof Tester

BI-680 Online Dissolved Oxygen Controller Instruction Manual

Vinmetrica Dissolved Oxygen System User Manual

STEAM STERILIZABLE POLAROGRAPHIC OXYGEN ELECTRODE

Experiment C-6 Gas Solubility

A180 DO/BOD/OUR/SOUR Meter Instruction Manual

LogIT Dissolved Oxygen Probe

Aerobic Respiration. Evaluation copy

SS32L Dissolved O 2 Probe

Evaluation copy. Interdependence of Plants and Animals. computer OBJECTIVES MATERIALS

Dissolved Oxygen Probe (Order Code DO-BTA)

ISE-730 Oxygen Electrode and DO2-100 Currentto-Voltage

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

Dissolved Oxygen in Water. Evaluation copy. Table 1. Temperature Range ( C) Trout Smallmouth bass Caddisfly larvae

Instruction Manual HI Portable Waterproof Dissolved Oxygen Meter.

Dissolved Oxygen Probe (Order Code DO-BTA)

12mm Dissolved Oxygen Sensor Care and Use Instructions

Heavy Duty Dissolved Oxygen Meter

Instruction Sheet. Important Note: Information that requires special emphasis. Note: Information that supplements points in the main text.

Bante904 Benchtop Conductivity/Dissolved Oxygen Meter Instruction Manual

STERILIZABLE DISSOLVED OXYGEN SENSORS

OxyProbe II Instruction Manual

OPERATION MANUAL DIVE CALIPER NOT SCALE / IF IN DOUBT ASK* *ALL UNITS IN MM/DEGREES UNLESS SPECIF. Dive Caliper General DC-051

INSTRUCTION MANUAL. 840 Transmitter. Loop Powered Dissolved Oxygen Transmitter

Dissolved Oxygen Meter. ino2. Instruction Manual. Serial No..

Instruction Manual HI Portable Dissolved Oxygen Meter. DO meter HI 8043 STB C OFF O 2 ZERO SLOPE C. ins rum n s

Experiments in Biology

Read this first. Zetasizer nano series Self installation and Quick start guide MRK825-02

Optical Dissolved Oxygen Meter

D-OptoLogger Dissolved Oxygen Logger Operation Manual

Dissolved Oxygen Sensor

Vernier Optical DO Probe (Order Code ODO-BTA)

Instruction Manual DO 6. Economy Hand-held Dissolved Oxygen Meter. 68X Rev 2 Apr 08. Technology Made Easy... Part of Thermo Fisher Scientific

Optical Dissolved Oxygen Meter

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

D-Opto Dissolved Oxygen Sensor Operation Manual for the D-Opto 4-20mA

Gas Pressure Probe. Information Sheet. Total Dissolved Gas

QUICK START GUIDE TO DRINKING WATER MONITORING

Gas Pressure Sensor (Order Code GPS-BTA)

Operating manual. TA 197 Oxi. Dissolved Oxygen Depth Armature

Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems

BIL 151 Laboratory Enzymes: Practicing the Protocol

1. Photosynthesis and Light. See real-time evidence that light causes photosynthesis to occur!

Instruction Manual. DO 700 Dissolved Oxygen/ºC/ºF Bench Meter. Technology Made Easy...

Conducting an XFe Assay in an Hypoxia Chamber at 3% O ²

HI 9143, HI 9143M HI 9145

Dextens Thermo Conductivity Sensors. Type 52101, 54101, 55101

Visit us at Code

Instruction Manual DO 6+ Dissolved Oxygen/Temp

Oxygen Dipping Probe PSt3 / PSt6 / PSt9

Oxymax W COS41. Technical Information. Potentiostatic amperometric two-electrode sensor Long-term stable sensor for water and wastewater applications

EC214 EC215 - EC215R Bench Conductivity Meters

Experiment B-3 Respiration

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

STARLOG. Capacitive Water Depth Probe

HI 2314 HI 2315 HI 23151

Aqua-DP. Aqua-DP Waterproof Dissolved Oxygen - ph -mv Temperature Meter. TPS Australia - Quality hand-made instruments since 1968.

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

Refillable ORP/Redox Probe: Model MTC30101 or MTC30103

Instruction Manual HI 9146 Dissolved Oxygen and Temperature Meter

SOLUBILITY OF A SOLID IN WATER

Dissolved Oxygen and measurement possibilities. Berno Lüpkes, 15 th March 2017

SodaStream is the modern way to enjoy delicious bubbles. without the bottles. No more lugging or storing heavy

Water Quality Monitoring Using a Handheld Sonde for in situ Measurements Date Prepared: 11/17/2017

Oxygen Measurement Systems High Reliability and Wide Application Coverage

D-Opto. Dissolved Oxygen Sensor. Operation Manual (Software Version 1.0)

D-Opto Dissolved Oxygen Sensor Operation Manual

WELCOME TO THE REVOLUTION

130 SSP Soluble Salt Profiler

SPECIFICATIONS APCEPH1

SensoDirect Oxi200 Dissolved Oxygen Meter Operating instructions

RDO Optical Dissolved Oxygen Sensor

Measuring the Conductivity of Pure Water Using USP<645>

VAC-U DRIVE Swinging float arm for Acrobat like agility 36 Fin disk with DEEP VEE Scoop

MARTINI. instruments. THANK YOU FOR CHOOSING. Sales and Technical Service Contacts:

Micro600DO_ZI INST /1/17 13:16 Page 1. Palintest. Micro 600 DO Meter. Palintest ZI INST 1240

STANDARD OPERATING PROCEDURE MAINTENANCE/CALIBRATION CHECKS OF DISSOLVED OXYGEN PROBES

YSI Model 52 Dissolved Oxygen Meter

Using the Akta Prime plus October 22, 2012

Pool and Spa. Water Testing

Free Chlorine Sensor For additional information, please visit our website at

SOLUBILITY OF A SOLID IN WATER

MASK INTEGRITY TEST ACCESSORY (MITA) MODEL 8120

YSI Model 550a Dissolved Oxygen (DO) Meter

UsER manual for Watersens ph -REDOX

TQC Bresle Chloride test 2008

WXG-4 Manual Polarimeter. Instruction Manual BANTE INSTRUMENTS CO., LTD

Radnoti Liver Perfusion System

Transcription:

imagine explore learn Oxygen Sensor with Electrode Product Number: ENOXY-A222 Overview The Oxygen sensor is a maintenance-free galvanic oxygen electrode, capable of measuring Oxygen both in the air and in solutions. The Oxygen sensor can be used to perform a wide variety of experiments in both liquid and gaseous environments. It is used in a variety of experiments such as measuring the amount of oxygen in an aquarium or understanding the effects of photosynthesis. The Oxygen Sensor can be connected to all types of einstein data loggers. Typical experiments Biology Monitoring changes in oxygen levels during photosynthesis and respiration of plants Consumption of oxygen by yeast during respiration of sugars Fermentation of yogurt Monitoring human respiration Monitoring changes in oxygen levels during photosynthesis and respiration of plants

O x y g e n S e n s o r 2 Water Quality Monitoring dissolved oxygen concentrations resulting from photosynthesis and respiration in an aquarium containing plants and/or fish Monitoring the pattern between light and dissolved oxygen levels, in an aquarium with pondweed On-site testing in streams and ponds to evaluate the capability of their water to support different types of plant and animal life Chemistry Oxidation of metals Discovering the change in oxygen level during combustion using a candle burning in a bell jar Sensor specification Range: 0 to 12.5 mg/l DO 0 to 25% O 2 Accuracy: Note: sensor cables sold separately Technical Notes If the ambient temp is different than 25 C, then calibrate the sensor (see below). It is important to stir the solution during measurement as oxygen consumption by the probe can momentarily reduce the oxygen concentration at the probe s surface. Do not allow any air bubbles to be trapped on the membrane surface, as it will read an air bubble as an oxygen saturated sample. The electrode membrane is very robust, relative to other electrodes. Its function is more of a physical barrier (permeable to O 2) rather than a chemical reaction type membrane. In pond water, its useful life is determined by how well it is cared for e.g. by avoiding stretching, scratching, and fouling the membrane. The membranes only problem areas are: o o o Scratches or tears - Scratches could change the accuracy of the probe, tears will cause immediate failure ± 7% over entire range Resolution (12-bit): 0 to 12.5 mg/l 0.003 mg/l 0 to 25% 0.007% Temperature Compensation: Response Time for 95% of Reading: Default Sample Rate No Up to 2 minutes 10 samples per second Fouling of the membrane - Impacts measurement only if it impedes the membranes permeability to DO. This is unlikely in pond water whereas in wastewater this may be a common problem. Stretching of the membrane - The thickness of the membrane and position of the membrane on the cathode are critical parameters of the measurement.

O x y g e n S e n s o r 3 Maintenance and Storage After the electrode has been used for a period of time the following cleaning method is recommended: 1. Carefully unscrew the cap from the body. 2. Rinse the inside of the membrane cartridge with DI water. 3. Soak the lead anode in 0.1N HCL (8.3 ml concentrated HCl in 1000 ml DI water) for 15 to 20 minutes. Rinse the lead anode with DI water, blot dry with tissue paper. Screw the lead anode back onto the body. 4. Rinse the soaked portions thoroughly with DI water. Blot dry with tissue paper. 5. Fill the cap with Galvanic O2 Fill Solution to a level just above the membrane cartridge using the dropper provided with the sensor. Hold the electrode in an upright position and gently screw the cap back onto the body. 6. Inspect the membrane for tears or leakage. The membrane should be uniformly stretched across the inner body. Replace the membrane if any damage has occurred. Membrane Replacement 1. The membrane should be examined routinely after each fermentation cycle and replaced if any deterioration is evident. See the illustration below. 2. Carefully unscrew the cap from the body. 3. Using the membrane tool provided, pop the membrane cartridge from the cap. 4. Inspect the platinum cathode. Gently wipe it with tissue paper and see if there are any cracks or damage. 5. Take a new membrane out of the plastic package and insert into the cap. Push it down inside until firmly seated inside the outer cap using the membrane tool provided. 6. Fill the cap with electrolyte to a level just above the membrane cartridge, using the dropper provided with the sensor. 7. Do not allow any air bubbles to be trapped on the membrane surface, as it will read an air bubble as an oxygen saturated sample 8. Hold the electrode in an upright position and gently screw the cap back onto the body. Inspect the membrane for tears or leakage. The membrane should be uniformly stretched across the inner body.

O x y g e n S e n s o r 4 Storage Short term (up to one week) 1. Inspect the membrane for tears or leakage. The membrane should be uniformly stretched across the inner body 2. Replace the membrane if any damage has occurred. Long term 1. Carefully unscrew the cap from the body. 2. Rinse the inside of the membrane cartridge with DI water. 3. Rinse the soaked portions thoroughly with DI water. Blot dry with tissue paper. 4. Screw the cap back onto the body without the electrolyte Data logging and analysis MiLAB 1. Take your einstein Tablet or pair your einstein LabMate with your Android or ios tablet via Bluetooth 2. Insert the sensor cable into one of the sensor ports 3. Launch MiLAB 4. MiLAB will automatically detect the sensor and show it in the Launcher View 5. Tap the Settings icon to set the sensor to measure dissolved Oxygen (DO) or atmospheric Oxygen (O 2) 6. Check the icon next to the sensor ( ) to enable it for logging MiLAB Desktop 1. Pair your einstein LabMate with your PC, MAC, or Linux machine via Bluetooth, or connect it via the USB cable (found in the einstein LabMate box). 2. Insert the sensor cable into one of the sensor ports. 3. Launch MiLAB. 4. MiLAB will automatically detect the sensor and show it in the Current Setup Summary window 5. Click Full Setup, located at the bottom of the Current Setup Summary window to program the data logger s sample rate, number of samples, units of measurement, and other options.

O x y g e n S e n s o r 5 6. Click the Run button ( ) on the main toolbar of the Launcher View to start logging. Experiment set up The Oxygen Sensor comes with: One Oxygen sensor One electrode One bottle Galvanic O 2 Fill Solution One bottle Salt for zero solution (Sodium Sulfite, Na 2SO 3) One plastic dropper Extra membranes Calibration When calibrating the Oxygen sensor you will have the choice of calibrating for Dissolved Oxygen (DO) or gaseous oxygen (O 2). DO Calibration MiLAB Desktop Set Zero Calibration In the Current Reading column, click Set cancels this action to set the current value as the zero or base value. Reset MiLAB Set Zero Calibration Under Current Reading column flip the Set As Zero switch to set the current value as the zero or base value. Calibrating in MiLAB Desktop Two Point Calibration 1. Go to the Full Setup window and in the Calibrate column click Set 2. The Calibration window will appear

O x y g e n S e n s o r 6 3. Saturate water with Oxygen by vigorously stirring the water. Enter the known value for saturated water according to your location in the Point 1, Real Reading field 4. Measure the solution and, wait for the readings to stabilize. Enter the measurement as the Point 1 Measured Reading field and click the lock button 5. Prepare a second solution with a known value (we recommend using the salt for zero solution in order to reduce the DO of water to zero). Enter this known value in the Point 2, Real Reading field 6. Measure the solution and, wait for the readings to stabilize. Enter the measured value as the Real Reading on the first line and click the lock button 7. Click Calibrate Calibrating in MiLAB Note: Graphics in your version of MiLAB may differ Two Point Calibration 1. Tap the Settings button next to the sensor s name 2. Flip the Calibrate switch to On 3. Saturate water with Oxygen by vigorously stirring the water. Enter the known value for saturated water according to your location in the Point 1, Real Reading field 4. Measure the substance and, wait for the readings to stabilize. Enter the value as the Point 1 Measured

O x y g e n S e n s o r 7 Reading field and click the lock button 5. Prepare a second solution with a known value (we recommend using the salt for zero solution in order to reduce the DO of water to zero). Enter this known value in the Point 2, Real Reading field 6. Measure the solution and, wait for the readings to stabilize. Enter the known value as the Real Reading on the first line and click the lock button 7. Click Calibrate O2 Calibration Calibrating in MiLAB One Point Calibration 1. Tap the Settings button next to the sensor s name 2. Flip the Calibrate switch to On 3. Choose a well ventilated location (preferably outside) 4. Enter 20.9 (the percentage of oxygen in the air) in the Point 1, Real Reading field 5. Hold the electrode in the air and wait for the readings in the Current Reading field to stabilize. 6. Enter the Current Reading value as the Measured Reading field and click the lock button 7. Click Calibrate. Calibrating in MiLAB Desktop One Point Calibration 1. Choose a well ventilated location (preferably outside) 2. Go to the Full Setup window and in the Calibrate column click Set 3. The Calibration window will appear

O x y g e n S e n s o r 8 4. Enter 20.9 (the percentage of oxygen in the air) in the Point 1, Real Reading field 5. Hold the electrode in the air and wait for the readings in the Measured Reading field to stabilize and click the lock button. 6. Click Calibrate Troubleshooting If the Oxygen sensor isn't automatically recognized by MiLAB, please contact Fourier Education's technical support. Technical support For technical support, you can contact the Fourier Education's technical support team at: Web: /support Email: support@fourieredu.com Phone (in the US): (877) 266-4066 Copyright and Warranty All standard Fourier Systems sensors carry a one (1) year warranty, which states that for a period of twelve months after the date of delivery to you, it will be substantially free from significant defects in materials and workmanship. This warranty does not cover breakage of the product caused by misuse or abuse. This warranty does not cover Fourier Systems consumables such as electrodes, batteries, EKG stickers, cuvettes and storage solutions or buffers. Fourier Systems Ltd. All rights reserved. Fourier Systems Ltd. logos and all other Fourier product or service names are registered trademarks or trademarks of Fourier Systems. All other registered trademarks or trademarks belong to their respective companies. ALBERT EINSTEIN and EINSTEIN are either trademarks or registered trademarks of The Hebrew University of Jerusalem. Represented exclusively by GreenLight. Official licensed merchandise. Website: einstein.biz