Instructions. Control Solution ICF 20-4, ICF 25-4, ICF ICF 40-4, ICF 20-6, ICF 25-6, ICF 32-6, ICF 40-6, Direction and Position.

Similar documents
Instructions. Control Solution ICF 20-4, ICF 25-4, ICF ICF 40-4, ICF 20-6, ICF 25-6, ICF 32-6, ICF 40-6, Direction and position.

Valve Station ICF 15, 20 and 25

Valve station ICF 15, ICF 20, ICF 25, ICF 50 and ICF 65

Selection of ICF made easy Save even more time with ICF

Capacities Valve Station, type ICF 15, 20, 25

Dual position solenoid valve Type ICSH 25-80

Solenoid valves, two-step on/off Type PMLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Overflow valves Type OFV REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Overflow valves Type OFV Type OFV-SS REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Gas powered stop valves, type GPLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Modulating liquid level regulators, servo-controlled PMFL / PMFH and SV

Solenoid Valves, one - or two step, on/off ICLX

2-step solenoid valve Type ICLX

2-step solenoid valve Type ICLX

Quick closing oil drain valve, type QDV 15 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Regulating valves Type REG 6-65 Type REG-SS REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Pressure regulating valves Types OFV, OFV-SS

Pilot valves for pilot operated servo valves

Liquid level regulating valves Types PMFL / PMFH and SV

PV4 and PV6 Piston Valves

MAKING MODERN LIVING POSSIBLE. Pilot operated internal safety valves type POV REFRIGERATION AND AIR CONDITIONING DIVISION.

Safety relief valves, type BSV 8 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Steam Trap BK BK 212-ASME. Original Installation Instructions English

KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions

Safety relief valves SFV 20-25

Regulating valves REG-SA and REG-SB

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Safety relief valves, type SFA 15 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Manual Actuated Boiler Blowdown Valves

Safety relief valves Type BSV-8

Installation & Operation Manual Proven Quality since 1892

Hand-operated regulating valves in stainless steel Types REG-SA SS and REG-SB SS

KBV21i and KBV40i Air Actuated Boiler Blowdown Valves

Engineering Data Sheet

Safety relief valves, type SFA 15

for for Industrial Refrigeration

Disassembling and assembling APP and APP 16-22

Contents. 1. General information BROEN BALLOMAX Steel Ball Valves Approvals Quality Management...2

APP pumps APP and APP Disassembling and assembling

MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL

Steam Trap BK 15 (DN40, DN 50) Original Installation Instructions English

Installation, Operating and Maintenance Instructions. V914 Cast Iron Flanged Swing Check Valve V914

Liquid level glasses, type LLG REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Float valves Types SV 4, SV 5 and SV 6

THE BP-690 SERIES. Operating and Service Manual. Series includes all variants of BP-LF/MF-690/691

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

ATS430 turbidity sensor Retractable insertion assembly

Safety relief valves Type SFV 20-25

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

Pressure Reducing Valve DMV 750 set range: bar

WW-720. Pressure Reducing Control Valve

Safety relief valves Type SFA 15 and SFA 15-50

AVM7 Stainless Steel Thermostatic Air Vent

Hand operated regulating valves Types REG-SA and REG-SB

WW-720. Pressure Reducing Control Valve

Operation Manual Piston Sensed Gas Pressure Regulators

Leak-Free Load-Control Valve SAE ½ psi flange

OPERATING INSTRUCTIONS

Seated valves VRB 3, VRG 3

1.0 - OPENING AND CLOSING THE DOOR

M10HTi ISO Tobacco Ball Valve Screwed, SW, BW and Flanged versions

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC

Modulating liquid level regulators, direct-controlled, type SV 1 and 3 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

Installation, operation & maintenance manual - original version

MSC-P and MSC-N Manifolds for Steam Distribution and Condensate Collection

TBV OPERATION AND MAINTENANCE MANUAL SERIES 2800: FLANGED BALL VALVE. For technical questions, please contact the following:

Pressure Dump Valve Service Kit for Series 2300 Units

INSTALLATION, OPERATION and MAINTENANCE MANUAL

SV5 Safety Valve Installation and Maintenance Instructions

3-PIECE BALL VALVE, 3600 PSI/ PN 248, WITH ISO DIRECT MOUNTING PAD 306M SERIES/ PED Category II

Declaration of Conformity as per Directive 97/23/EC

INSTALLATION & MAINTENANCE INSTRUCTIONS - ORIGINAL VERSION AVK KNIFE GATE VALVES

M33F ISO, M33S ISO and M33V ISO Ball Valves Installation and Maintenance Instructions

Reliable System Performance PM valves

Pressure relief valve

CAST IRON SAFETY VALVE TYPE 6301

Shut-off ball valve Type GBC

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC

36% higher capacity than market alternatives. New ICF 50-4 and ICF 65-3: A great valve family just got greater.

Needle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

Apollo Standard Port, Full Port & One Piece Flanged Ball Valves Installation, Operation, & Maintenance Manual

3/8" Dr. Air Butterfly Impact Wrench

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50 Systems Outfitted with ABM-725 Monitor C O M P A N Y

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

Inverse Proportional Pressure-Relief Cartridge, Size 10

Bermad Pressure Reducing. Model: 42T

Bray/ VAAS O-Ported Series Knife Gate Valve 770/780 Series Operation and Maintenance Manual

80% Less installation time with just two welds for fast and efficient installation.

Installation, Operation and Maintenance Manual for Back Pressure Regulator

BCV31 DN40 - Blowdown Control Valve

Direct Operated Precision Regulator Modular Style. Standard Specifications

Translation of the original Operating Instructions for HKS rubber compensators

80% Less installation time with just two welds for fast and efficient installation.

Pilot Operated Pressure Reducing Valve

HM and HM34 Inverted Bucket Steam Traps Installation and Maintenance Instructions

Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0

Transcription:

027R9789 Instructions Control Solution ICF 20-4, ICF 25-4, ICF 32-4. ICF 40-4, ICF 20-6, ICF 25-6, ICF 32-6, ICF 40-6, Direction and Position ICF xx-4 ICF xx-6 ICF xx-4 / ICF xx-6 with ICM 027R9789 Fig. 1a Fig. 1b Fig. 1c Welding TIG/MIG welding All modules must be fully opened before welding. Other welding methods Remove all parts before welding. Danfoss M27H0049_1 Fig. 2 Fig. 3 Danfoss A/S (AC-AKC/ frz), 06-2007 DKRCI.PI.FT0.A4.22 / 520H2244

Service and maintenance Fig. 4 Tightening torques ICF 20: ICF 25-40: 50 Nm (36 lbf) 80 Nm (58 lbf) 50 Nm (36 lbf) 50 Nm (36 lbf) Fig. 5 2 DKRCI.PI.FT0.A4.22 / 520H2244 Danfoss A/S (AC-AKC/frz), 06-2007

Operating the manual opener on ICF 25 solenoid module To open the solenoid by the manual stem turn it counter clockwise full way up. To close the solenoid by the manual stem turn it clockwise until the locking ring stop. Do not force the spindle further, in case the locking ring is damaged or removed the spindle will start to leak. The valve can not be forced to close by the manual stem. ICF 25-40 solenoid valve module Locking ring Turn spindle counter clockwise to open Module location ICF 20-4 In order to supply the ICF solution best suited for liquid lines and hot gas lines certain function modules are dedicated to specific module ports. Function M1 M2 M3 M4 ICFS 20 - Stop valve module ICFR 20A - Manual regulating valve module ICFF 20 - Filter module ICFE 20 - Solenoid valve module ICFA 10 - Electronic expansion valve module ICFO 20 - Manual opening module ICFC 20 - Check valve module ICFN 20 - Stop/check valve module ICM 20-A, B or C - Motor valve module ICFB 20 - Blank top cover 0, 2 or 4 optional side ports (up to 6 on request) location not possible Fig. 6 ICF 20-6 In order to supply the ICF solution best suited for liquid lines and hot gas lines certain function modules are dedicated to specific module ports. Function M1 M2 M3 M4 M5 M6 ICFS 20 - Stop valve module ICFR 20A - Manual regulating valve module ICFF 20 - Filter module ICFE 20 - Solenoid valve module ICFA 10 - Electronic expansion valve module ICFO 20 - Manual opening module ICFC 20 - Check valve module ICFN 20 - Stop/check valve module ICM 20-A, B or C - Motor valve module ICFB 20 - Blank top cover location not possible 0, 4 or 6 optional side ports (up to 10 on request) Fig. 7 Danfoss A/S (AC-AKC/ frz), 06-2007 DKRCI.PI.FT0.A4.22 / 520H2244 3

ICF 25-4 40-4 Danfoss M27H0004_1 Module location In order to supply the ICF solution best suited for liquid lines and hot gas lines certain function modules are dedicated to specific module ports. Function M1 M2 M3 M4 ICFS 25-40 - Stop valve module ICFR 25-40 A or B - Manual regulating valve module ICFF 25-40 - Filter module ICFE 25-40 - Solenoid valve module ICFC 25-40 - Check valve module ICFN 25-40 - Stop/check valve module ICM 25-A or C - Motor valve module ICFB 25-40 - Blank top cover ICFW 25-40 - Welding module, 25DIN location not possible 0, 2 or 4 optional side ports (up to 6 on request) Fig. 8 ICF 25-6 40-6 Danfoss M27H0005_1 In order to supply the ICF solution best suited for liquid lines and hot gas lines certain function modules are dedicated to specific module ports. Function M1 M2 M3 M4 M5 M6 ICFS 25-40 - Stop valve module ICFR 25-40 A or B - Manual regulating valve module ICFF 25-40 - Filter module ICFE 25-40 - Solenoid valve module ICFC 25-40 - Check valve module ICFN 25-40 - Stop/check valve module ICM 25-A or C - Motor valve module ICFB 25-40 - Blank top cover ICFW 25-40 - Welding module, 25DIN location not possible 0, 4 or 6 optional side ports (up to 10 on request) Fig. 9 4 DKRCI.PI.FT0.A4.22 / 520H2244 Danfoss A/S (AC-AKC/frz), 06-2007

The function modules - ICF 20 ICFS 20 stop valve module ICFR 20 manual regulating valve module 3. AL-gasket 3. AL-gasket 8. Seat ICFF 20 filter module 1. Gasket 2. Bonnet 3. Hex-head bolt 4. Flange 6. Filter element 7. Plug 8. Plug 1/4 RG ICFC 20 check valve module 1. Bonnet 2. Hex-head bolt 3. Flange 4. Gasket ICFE 20 solenoid valve module ICFA 10 Electronic expansion valve 1. Armature tube 2. Armature tube nut 3. Flange 4. Gasket 6. Seat 1. Armature tube 2. Armature tube nut 3. Hex-head bolt 4. Flange 6. Adaptor ICFO 20 manual opening module ICM 20 A, 20 B or 20 C motor valve module 1. Hex-head bolt 2. Flange 4. Rubber gasket 5. Spindle 1. Adapter 2. Hex-head bolt 6. Seat ICFN 20 stop/check valve module ICFB 20 blank top cover module 1. Hex-head bolt 2. Flange 3. Gasket 3. AL-gasket Danfoss A/S (AC-AKC/ frz), 06-2007 DKRCI.PI.FT0.A4.22 / 520H2244 5

The function modules - ICF 25-40 ICFS 25-40 stop valve module ICFR 25-40 A or B manual regulating valve module ICFF 25-40 filter module ICFC 25-40 check valve module 1. Al gasket 2. Bonnet 3. Hex-head bolt 4. Flange 6. Filter element 7. Plug 1/4 RG 1. Bonnet 2. Hex-head bolt 3. Flange 4. Gasket ICFE 25-40 solenoid valve module ICM 25 A or 20 B motor valve module 1 2 3 4 5 6 1. Armature tube 2. Armature tube nut 3. Bonnet 4. Gasket 6. Seat 1. Adapter 2. Hex-head bolt 6. Seat ICFN 25-40 stop/check valve module ICFB 25-40 blank top cover module 1. Hex-head bolt 2. Flange 3. Gasket ICFW 25-40 Welding module 25 DIN 1. Hex-head bolt 2. Flange 3. Gasket 4. Weld connection 6 DKRCI.PI.FT0.A4.22 / 520H2244 Danfoss A/S (AC-AKC/frz), 06-2007

ENGLISH Installation Refrigerants Applicable to all common non-flammable refrigerants, including R717 and noncorrosive gases/liquids dependent on sealing material compatibility. The use of ICF solutions with flammable hydrocarbons is not recommended. The ICF is only recommended for use in closed circuits. For further information please contact Danfoss. Temperature range 60/+120 C ( 76/+248 F) Pressure range The ICF is designed for a max. working pressure of 52 bar g (754 psi g). Technical data The ICF can be used in suction, liquid, hotgas and liquid/vapor lines. The ICF are available with 4 or 6 function modules. The ICF regulates the flow of the medium by modulation or on/off function, depending on function modules installed on the ICF. Regulating range Dependent on the chosen type and combination of modules installed in the valve. Installation The ICF must be installed with the modules 1,3,5 vertically upwards position (fig. 1). The ICF must be installed with the arrow in the direction of the flow). The ICF will be delivered with all the function modules fully assembled. The modules can be taken off for service or inspection and may be rotated 4 x 90 in relation to the valve body upon installation. The ICF may be fitted with a spindle for manual opening of the solenoid valve. The ICF is designed to withstand a high internal pressure. However, the piping system should be designed to avoid liquid traps and reduce the risk of hydraulic pressure caused by thermal expansion. It must be ensured that the ICF is protected from pressure transients like liquid hammer in the system. Welding The ICF solution can be welded by using either TIG /MIG welding (fig. 2) or arc welding (fig. 3). Attention! It is not necessary to remove any of the modules before TIG/MIG welding; however, it must be ensured that all valve modules are opened before the welding process takes place and that the ICF is protected against weld splatter. During arc welding the modules must be removed. Avoid welding debris and dirt in the valve body and the function module. The housing must be free from stresses (external loads) after installation. The ICF must not be mounted in systems where the outlet side of the ICF is open to atmosphere. The outlet side of the ICF must always be connected to the system or properly capped off, for example with a welded-on end plate. Colours and identification The ICF solutions are Zinc-Chromated from factory. The Zinc-Chromatization does not cover the welding connections. If further corrosion protection is required, the ICF can be painted. Precise identification of the ICF is made via the ID label on each of the 4 or 6 function modules. The external surface of the housing must be protected against corrosion with a suitable top coating after installation involving welding and consequent assembly. Protection of the ID label when painting the ICF is recommended. Maintenance Service The ICF solutions are easy to service. Do not open the ICF while the it is still under pressure. Debris blocking the bolt hole will need cleaning. Upon opening and removal of the function modules: - Check that the O-rings on the function module has not been damaged. A valve with a damaged o-ring might not modulate according to the specification. - Check that the piston and cylinder is free of scratches and look for wear marks. If the wear is excessive the function module should be replaced to prevent false pilot signal around the piston ring. - Check that the movement of the cylinder and valve seat is free and with low friction. - If the teflon valve plate has been damaged, the function module must be replaced. Assembly Remove any dirt from the housing before the ICF is assembled. - Check that all channels in the ICF are free of particles or similar debris. If possible, apply some refrigeration oil to ease the insertion of the modules and to protect the O-rings. Tightening (fig. 5) Tighten the top cover with a torque wrench, to the values indicated in the table. Use only original Danfoss parts, including O-rings and gaskets for replacement. Materials of new parts are certified for the relevant refrigerant. In cases of doubt, please contact Danfoss. Drawings are only for illustration, not for dimensioning or construction. Danfoss accepts no responsibility for errors and omissions. Danfoss Industrial Refrigeration reserves the right to make changes to products and specifications without prior notice. Danfoss A/S (AC-AKC/ frz), 06-2007 DKRCI.PI.FT0.A4.22 / 520H2244 7

Name and Address of Manufacturer within the European Community Danfoss Industrial Refrigeration Stormosevej 10 PO Box 60 DK-8361 Hasselager Denmark Description of Pressure Equipment Refrigerant regulation valve, with straight bonnet arrangement Type ICM, ICS, ICL, ICF Nominal bore Classified for ICM, ICS, ICL, ICF DN20-80 mm ( 3 / 4-3 in.) Fluid Group I (all refrigerants (toxic, non-toxic, flammable and non-flammable)) For further details / restrictions - see Installation Instruction Temperature range ICM, ICS, ICL, ICF 60 C/+120 C ( 76 F/+248 F) Maximum allowable working pressure ICM, ICS, ICL, ICF DN20-DN80 ( 3 / 4-3 in.) Declaration of Conformity The Pressure Equipment Directive 97/23/EC 52 bar (754 psi) 60 C/+120 C ( 76 F/+248 F) Conformity and Assessment Procedure Followed ICV 25-65 platform ICV 20 Category II Article 3, paragraph 3 Module Certificate ID Nominal bore Standard appl. D1 D1: 07 202 0511 Z 0009/1/H-0002 ICM, ICS, ICL, ICF DN20-80 mm ( 3 / 4-3 in.) ICM DN 15-25 ( 1 / 2-1 in.) Name and Address of the Notified Body which carried out the Inspection TÜV-Nord e.v. Grosse Bahnstrasse 31 22525 Hamburg, Germany (0045) Name and Address of the Notified Body monitoring the Manufacturer's Quality Assurance System TÜV-Nord e.v. Grosse Bahnstrasse 31 22525 Hamburg, Germany References of Harmonised Standards used EN 10213-3 EN 10222-4 References of other Technical Standards and Specifications used EN 12284 AD-Merkblätter Authorised Person for the Manufacturer within the European Community Name: Michael Breumsø Title: Production Manager Signature: Date: 01/03/2006 148B9746 - rev. 3 ECM 500000018810 8 DKRCI.PI.FT0.A4.22 / 520H2244 Danfoss A/S (AC-AKC/frz), 06-2007