Prep LC Training Manual

Similar documents
Prep LC Training Manual S.V.

SOP: Buck Scientific BLC-20P HPLC Operation

GCMSD-Headspace Analysis SOP

AKTA pure 25 New Owner s Intro

AKTA ION EXCHANGE CHROMATOGRAPHY SOP Date: 2/02/05 Author: A DeGiovanni Edited by: C. Huang Reviewed by:

Setting a New Standard in Flash Chromatography Performance

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

Figure 1: Plug in ion inlet of mass spec

The instrument will process the samples one by one till all the samples have been cleaned up.

Agilent 1100 Series Analytical and Preparative Scale Fraction Collectors. User s Guide

AKTA 3D SOP. Click on the System Control tab. This screen has 4 windows.

DOS in Food Science & Nutrition, Manasagangotri, Mysore

User guide for operating the Agilent 6420A QqQ mass spectrometer by direct infusion/injection

Application Note. Rapid performance verification of AZURA systems with refractive index detector. Summary. Introduction

Recovery collection complete sample recovery in preparative HPLC

AKTA MC SOP Page 1 9/27/04 AKTA METAL CHELATING SOP

5890II GC Standard Operating Procedure 9/2/2005

SHIMADZU LC-10/20 PUMP

System Overview. TCD Detector temperature setpoint Regulator

PerkinElmer Aanalyst100

Operation of the Perkin Elmer TGA-GC/MS

Optimizing Vial Pressurization Parameters for the Analysis of <USP 467> Residual Solvents Using the 7697A Headspace Sampler

User s Booklet for the Wyatt minidawn Light Scattering Instrumentation

Gas Diluter Portable Gas Dilution System User s Manual

Customer Responsibilities. Important Customer Information. Agilent Infinity II Preparative HPLC System Site Preparation Checklist

ANALYTICAL SCALE HPLC AGILENT SYSTEMS OPERATIONAL QUALIFICATION

Agilent 1260 Infinity Purification Solution

Acclaim RSLC. (Rapid Separation Liquid Chromatography)

Extended Application Note

Varian 3300 Gas Chromatograph Abbreviated Operating Instructions

Ghost Peaks: How to Fix a Haunting Problem. Jacob A. Rebholz Teledyne Tekmar VOC Product Line Manager

Ascentis Express HPLC Columns with Fused-Core Technology

LC, RSLC, Bio RS and Dual Gradient Systems

UltiMate 3000 Viper Capillary Kits for Intelligent LC (LCi) System Solutions

Video Notes. LC Troubleshooting Series Retention Time Shifts

More Speed and Resolution for Current Methods

User Manual. Agilent 1260 Infinity Analytical- and Preparative-scale Fraction Collectors

Armfield Distillation Column Operation Guidelines

OMCL Network of the Council of Europe QUALITY ASSURANCE DOCUMENT

operator s manual plus system system nanolc Operator s Manual Revision A1

Agilent 1290 Infinity LC System Applications requiring the Agilent Ultra-Low Dispersion Kit

Precisely HPLC. Hints, Tips, Guidelines and Important Considerations. Presenters: Wilhad Reuter / Tom Breslin

Calibration of a GC955

The instrument should have a mass range from 2 to 2000 m/z or better Interface

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Advancements in Gas Chromatography Analyzers - Keeping up with New Technology. Chuck Runkle Gas Phase Product Specialist ASTS June 2013

TROUBLESHOOTING. Dwell Volume Revisited. Gradient transfer does not have to be problematic.

Using the Akta Prime plus October 22, 2012

HPLC. Solvent Delivery Module Systems

Automated Low Background Solid Phase Extraction of Perfluorinated Compounds in Water. Ruud Addink Fluid Management Systems Watertown MA

NanoSight NS300. NanoSight NS300. Operation instructions. Laser Spectroscopy Labs, UCI

Agilent Dimension Software for ELSD User Manual

Standard Operational Procedure for Capillary Electrophoresis

Quick Start Guide for SA-9600 Series Surface Area Analyzer

SSI Solaris 150 RTA Revision /27/2016 Page 1 of 9. SSI Solaris 150 RTA

GHSA Swimming/Diving POP School User s Guide

The Application of QuEChERS in the Extraction of Anabolic Steroids in Whole Blood

Agilent 1220 Infinity II LC Mobile Upgrade Kit

FRANZ CELL TEST OF NANO GLUTATHIONE WITH HPLC ANALYSIS

6900 Maintenance Instruction System Flush

SOP for use of the SX19 Stopped-Flow Instrument

This GC has two columns (I think new columns can be ordered from Restek)

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

FIG: 27.1 Tool String

Standard Operating Procedure Inductively Coupled Plasma Optical Emission Spectrometer (ICP-OES) - Thermo Scientific icap 6300

JETFIRST 150 RTA SYSTEM OPERATING MANUAL Version: 2 Feb 2012

In Response to a Planned Power Outage: PPMS EverCool II Shut Down and Re-start Procedure

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings

OPERATORS MANUAL G U A R A N T E E D T R Y C H E M APPROVED

Running HPLC Methods on an ACQUITY UPLC System

Automated Determination of Dissolved Gases in Water Anne Jurek. Abstract: Discussion:

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Varian 310

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

Prep 15 SFC System System Guide / Revision A Copyright Waters Corporation 2014 All rights reserved

Evaluation of linear and step gradient performance and retention time precision of the Agilent 1200 Series Rapid Resolution LC

SOP: Anion Exchange Chromatography of Green Fluorescent Protein (GFP) using the AKTA Pure system

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

SOP: Cation Exchange Chromatography of t-pa using AKTA Pure system

6800 Maintenance Instruction System Flush Procedure

School of Molecular Bioscience SMB019. Kamrul Zaman

Superconducting Susceptometer (MPMS-5S) Quantum Design Room 296 (MPMS)

Agilent ICP-MS Interactive Troubleshooting tool for Low sensitivity

Water Weir Flow Controller. Introduction. Safety Precautions. Mounting the Hardware

Varian 325-MS LC/MS Quadrupole Mass Spectrometer Pre-installation Instructions

Manual for continuous distillation

Simplified Backflush Using Agilent 6890 GC Post Run Command Application Note

Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems

Ensuring Best Possible UHPLC Performance Through an Innovative Capillary and Fitting Design

SDS 9414i HPLC Pump. 1. Standard Accessories Stainless Steel Version PEEK Version Safety Instructions...

Pre-installation Checklist

FROG-4000 TM Chemical Analysis System

CHM Gas Chromatography: Our Instrument Charles Taylor (r10)

GN21 Frequently Asked Questions For Golfers

6890 GC Not Ready Messages (A16010)

16. Studio ScaleChem Calculations

AutoTrace SPE Workstation User s Manual

McKnight Hockey Association

Air Operated Hydraulic Pumping Systems to 50,000 psi

Supporting information for J. Med. Chem., 1994, 37(5), , DOI: /jm00031a018

Eksigent MicroLC 200 Plus System. Operator Guide

Transcription:

Prep LC Training Manual (11-6-2013) Location: 1238 Hach Hall Contacts: kamel Harrata and Steve Veysey, 1234 Hach Hall Safety: Introduction:

The Agilent PrepStar SD-1 preparative HPLC is a student operated instrument. Students (and other researchers) are given an appropriate training in order to affect the prep experiments themselves. The instrument can be operated in analytical, semi-prep, and prep mode. Three C18 column sizes are available: analytical (4.6*50 mm, 1.8 um), semi-prep (9.4*250 mm, 5 um), and prep (21.2*250 mm, 7 um). Approprite guard columns are also available and must be used in all circumstances. Two Rheodyne manual injectors are mounted next to the pumps. The top one is for analytical and semi-prep with 500 ul sample loop. The bottom one is for the Prep experiments and is equipped with a 10 ml sample loop. Sample collection tubes are provided. Larger size collection tubes or beakers can be used for large collection volumes. The training will include, among other hardware pluming issues, how to remove and install LC columns. Overview: The SD-1 PrepStar is a dual pump (binary) capable of drawing from to separate solvent reservoir A and B. The A reservoir is dedicated to aqueous solutions while the B is always reserved for the organic solutions. The solvent delivery is system a dual interchangeable pump heads that provide pumping capacity to 3.2 L per minute at pressures of up to 375 psi for high throughput microparticulate columns.

Table 1 illustrates general considerations for column size, flow rates, injection volumes, and sample load. Column ID Flow Rate Sample load (mg) Injection volume 4.6 mm (analytical) 9.4 mm (semi-prep) 21.2 mm (prep) 1 ml/min 4.2 ml/min 21.0 ml/min 2-10 mg 10-50 mg 50-200 mg 1-20 ul 100-400 ul 500ul-5 ml Operating Instruction: Table 1 Before starting an experiment, make sure there is enough solvents in reservoir A and reservoir B. Choose which manual injector to use. Top injector is for analytical and bottom one is for the prep separation. Also, make sure that the purge line and waste line tubing are inserted in their respective bottles. Operating the instrument consists of: 1- Setting up the method

2- Starting and stopping an experiment!!!!pay attention to the Flow rate. It must be 0.000 ml/min when there is no intention of having solvent flow!!!! For existing method, simply open the desired method from the pull down menu Method. Click on ON button. Verify that the flow rate is the desired one. Allow the flow of solvent for sometime until the back pressure is stable. Direct Control: You can control each device directly. Simply right click on the field of the device and set the desired conditions. Setting up new method: All methods are located in C:\Chem32\1\METHODS directory. We prefer that each user possesses only one method under ISU username (e.g. C:\Chem32\1\METHODS\usename). Files are always located in C:\Chem32\1\DATA\filname directory. Filnames must be in the form of usernamexxx, where XXX is the incrementing number. Open the prep LC program:

From the Method drop down menu click on Edit Entire Method:

Set up flow rate and solvent composition. Click Apply. Set up detector conditions by clicking on the PS-325

Enter wavelengths values. Run time or experiment time is entered in this page. Set up Fraction Collector by clicking on

Click OK and save the method: Alternatively you can collect samples automatically by entering the Action (time slice) or you can collect fraction manually. If you want to manually collect sample simply use the buttons on the main instrument page: The divert valve waste contain 4 buttons. The left one allows collection. The next one to the right stops collection. Data Acquisition: From Run Control---Sample info tabs you can set sample name data file etc Proceed to acquisition by clicking Single sample.

Test Mix Standard Experiments: Operating Conditions: Semi-Prep: Eclipse XDB-C18 9.4*250 mm, 5 um Mobile Phase: 70% Acetonitrile/30% Water Flow Rate: 4 ml/min Injection Volume: 50 ul Column back pressure: 1000 PSI Peak# Conc (ug/ml) Compound 1 100 Uracil 2 4000 Phenol 3 500 4-Chloro Nitrobenzene 4 800 Naphthalene