User manual. MNPG 102 Rev. 04 Edition 04/02/16. Pressotherapy model. Power-Q1000 Premium

Similar documents
User manual. PG132 Rev01 Editi Compressive Limbs Therapy System DVT-7700

User manual. PG89 Rev 01 Editi Pressotherapy model. LymphoPress 4

POWERPRESS UNIT. User Manual. Gradient Pneumatic Sequential Compressor. Neomedic

Intermittent Pneumatic Compression System

DYNAMIC COMPRESSION THERAPY

USER MANUAL. MNPG69-06 Edition 11/09/15. Magnetotherapy model MAG700. I.A.C.E.R. Srl.

USER MANUAL. MNPG69-02 Edition 08/07/13. Magnetotherapy model MAG700. I.A.C.E.R. Srl.

Instruction Manual for Configura Cushionair Portable Pump

BTL-6000 LYMPHASTIM BTL PRESSO-THERAPY SYSTEM FOR MEDICAL AND AESTHETIC PRACTICES

INSTRUCTION MANUAL. Automatic Blood Pressure Monitor with Fit Cuff. =Fit Cuff=!"#$% IA1B. Model

AIR PRESSURE MASSAGER #Unwind

LYMPHA PRESS MANUFACTURED BY MEGO AFEK IMPORTED BY LYMPHA PRESS USA, Ltd. USERS MANUAL LYMPHA PRESS MODEL 201-M

1 METRON MANIPULATION TABLES - WARRANTY STATEMENT

77-I0PN230 Rev. A. Model 1030 User Manual

CONTENTS SPECIFICATIONS GENERAL INFORMATION RECOMMENDED USE OPERATING PRINCIPLE TIPS ON TAKING YOUR BLOOD PRESSURE 3-4 BATTERY INSTALLATION

USER MANUAL LTH-255A Hand Piece

Diamond 8 Plus. Alternating + Micro Low Air Loss Pressure Relief System. User Manual. Distributed by: Quart Healthcare Inc.

User Manual. Indications for safety use This product is intended for use by medical professionals or patients who are under medical supervision.

Med Aire Alternating Pressure Pump and Pad System

Company building TOTAL SOLUTION OF AIR COMPRESSION THERAPY SYSTEM. New second factory. Main office & Factory Stories house

Stroller. Sprint S T R O L L E R S P R I N T

Instructions for Use (IFU) Electrical Leg- & Arm lift, model , ver. 2012

DENAS Reflexo (p.21 40)

6833_INSTRUCTIONS MANUAL DIGITAL WIRST BLOOD PRESSURE

Pressure Automated Calibration Equipment

Introduction. Table of Contents. Automatic Wrist Blood Pressure Monitor With Voice-Guided Operation. Model No.: BP5K

ORB-400 BUBBLE/HAZE MACHINE. Item ref: UK User Manual

OPERATION INSTRUCTIONS

OPERATION MANUAL PNEUMATIC VALVES

CJMJ.DPNQBDU. Instruction for use. Neonatal phototherapy device. BILI-COMPACT WY 1816/ Year of manufacture D2017_00

Model UB-328. Wrist Digital Blood Pressure Monitor. Instruction Manual. Manuel d instructions. Manual de Instrucciones. Manuale di Istruzioni

F-330 Instruction manual. Magic Glove Bio Skin Smoother High Frequency Ultrasound Galvanic

Portable oxygen concentrator

Defibtech AED Training Equipment. User Manual

Hi Flow Stroller H I F L O W S T R O L L E R

VENTI-O 2 plus. O 2 switching valve for: VENTImotion from serial number 4000 VENTIlogic from serial number 4000 VENTImotion 2

PORTABLE WORK LIGHT MODEL NO: CL6FS OPERATION INSTRUCTIONS PART NO: GC0315

The Univentor 1250 Anaesthesia Unit

User Guide Antidecubitus systems EURO BASIC

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

VERTICAL AIR COMPRESSORS

SC505 Sof Care Inflator. Operating Instructions and Service Manual

Fingertip Pulse Oximeter

VER: A00. Model No:BA2010

OPERATOR S MANUAL. Pediatric/Infant cap-one Mask YG-232T/YG-242T A. General. Safety Information WARNING WARNING WARNING. Components WARNING

MODEL Maverick Heavy Duty Aerosol Compressor Operator s Manual

Instructions for Cleaning & Maintaining Air Compressor

AutoChanger Installation & User Guide Issue 2

30000 Series Treatment Tables

Research Grade Blood Pressure Transducer User's Manual

Resusci Anne Simulator

User Manual PTW-DensiX. D / Di/Zi

FLOWTRON HYDROVEN 3. User Manual. Intermittent Pneumatic Compression System

CONSOLE-320 ENGLISH. 230A: CONSOLE-320 with cable data output Item 230B: CONSOLE-320 with cable + wireless radio data output

DISPOSITIVI, SISTEMI E IMPIANTI PER L EVACUAZIONE DEI GAS ANESTETICI DEVICES, SYSTEMS AND PIPELINE SYSTEMS FOR ANAESTHETIC GAS SCAVENGING

Tourniquet Systems Pressure Infusion

APH166 Morpheus Air USER MANUAL. Apollo Healthcare Technologies Ltd. Holme Street, Liversedge, West Yorkshire, WF15 6JF.

INDUSTRIAL - SOLVENT PARTS CLEANER

SkillGuide. User Guide. English

Comfortmax Thermax Hot/Cold Water Circulation System. Instructions for Use

GATOR Battery-powered Pistol Grip Cable Cutters

Model AUTOMATIC UPPER ARM Blood Pressure Monitor

e.do Gripper Safety requirements, technical features and assembly and integration instructions

Paradise Pump Series Operator s Manual

Air Plus User Manual

U S E R M A N U A L. Model: PM4300 Series SAVE THESE INSTRUCTIONS

Digital Blood Pressure Monitor for the Upper Arm INSTRUCTION MANUAL

User Manual Article number: I

PNEUMATIC STOPPERS OPERATING MANUAL. Type F G H - FOG

MP15 Jockey Pump Controller

VERTICAL AIR COMPRESSORS

Indications for Use: Caution: Note:

EPSILON. User Manual. EP-5KG (5000g x 1g) Copyright 2011 American Weigh Scales, Inc. All rights reserved. Rev. 1.0

USER MANUAL SAVE THESE INSTRUCTIONS. 300 Held Drive Tel: (+001) Northampton, PA USA Fax: (+001) ISO Certified

USER MANUAL. JET TST and JET TST S.

CircuFlow TM 5150 Series

Regalia Oxygen Concentrator

INSTRUCTIONS FOR USE BODY ARMOR PRO TERM

MANUAL BLOOD PRESSURE MONITOR BPM 168B Contents Blood Pressure Monitor Intended Use What is blood pressure?

Domiciliary Oxygen Switch. Instructions for Use

Digital Melting Point Apparatus

Arena by Oregon Scientific

OC4000 USER'S GUIDE I O OXYGEN CONCENTRATOR FOR VETERINARY USE ONLY. by Supera Anesthesia Innovations GLOSSARY OF SYMBOLS. : ON (power switched on)

OC Panel High Limit Aquastat Kit, Manual Reset p/n

TECHNICAL CHARACTERISTIC CT 071

Techcon Systems TS1258 Pressure Pot

User Manual. Quantos Automated Dosing Liquid Module

WELCOME TO THE REVOLUTION

KAYAK ERGOMETER. Operating Instructions (Rev 3.0)

OPERATING INSTRUCTIONS PSORIAMED. Revision: 1.0-D GB

Arc4Health User Manual

Semi-Automatic Blood Pressure Monitor with Memory

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

T130/T131/T147. Economy Basket Stretcher with Lifting Kit

OPERATING AND MAINTENANCE MANUAL GOLD LINE EXTRACTION CLEANERS M14-M26

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

Technical information. 700 version software. 500 version software. 700 IFI version software. 500 IFI version software. User manual

Oxygen Dialflow Meter. Instructions for Use

Contents. 中文日本語 Br Es Nl De Fr It Uk

200 PSI FAST-FILL AIR SOURCE KIT

Transcription:

User manual MNPG 102 Rev. 04 Edition 04/02/16 Pressotherapy model Power-Q1000 Premium

I.A.C.E.R. Srl Via S. Pertini 24/A 30030 Martellago (VE) ITALY Tel. 041.5401356 Fax 041.5402684 e-mail: iacer@iacer.it http://www.itechmedicaldivision.com

MDD 93/42/EEC Compliance

Summary Summary 4 Pressotherapy 5 Machine body 6 Graphic display detail 6 Accessories 7 Accessories size 8 Configurations 9 Specifications 10 Technical Specifications 10 Purpose 10 Working instructions 11 Warnings 18 Cleaning 21 Disposal 21 Assistance 22 Spare parts 22 Warranty 22 IACER SRL Page 4 di 24 MNPG102-04 04/02/16

Pressotherapy Compressive limbs therapy is able to promote a right venous circulation by decreasing muscle tension caused by stress or chronic and acute pains: thanks to its pump action it favorites venous return by increasing tissues blood circulation and finally their physiological renewal. Compressive limbs therapy can solve blood stagnation problem in damaged sanguine vessels or in body zones not correctly bedewed. External compression allows excess interstitial fluids to return in circulatory system in order to be quickly removed. Most common applications are: Body massage increase; Blood flow promotion thanks to a slow and progressive pressure; Lymphatic drainage; Lower limbs relief and comfort; Substances stagnation prevention in peripheral tissues; Blood insufficiency prevention caused by an inadequate pump action; Muscle tone loss in disabled or paralyzed patients. Compressive limbs therapy substitutes the manual massage for trophic purposes. IACER SRL Page 5 di 24 MNPG102-04 04/02/16

Machine body 1 4 3 2 3 (1) : ON/OFF button (2) : LCD graphic display (3) : Programs menu buttons (4) : Air discharge output Graphic display detail (1) MENU : menu selector (Mode, Pressure time, Interval, Time, Pressure). (2) MOVE : programs menu selector (Mode, Pressure time, Interval, Time, Pressure). (3) SET : programs values selector (4) START/STOP: start/stop selector (5) SAVE : store button (keeping pressed for 5 seconds) (6) RESET : reset button (keeping pressed for 5 seconds) (7) LCD graphic display (8) PRESSURE (mmhg): pressure value (9) MODE: mode selector (A1, A2, B, C, D(D1, D2, D3, D4), E) (10) INTERVAL : interval time (5,10,15,20,25,30 sec) (11) TIME (min) : therapy time (5 99 min) IACER SRL Page 6 di 24 MNPG102-04 04/02/16

(12) PRESSURE TIME : air flow speed (5,7,9,11,13,15,17,19,21 sec). (13) LEG PICTURE: shows the working compression chamber. Accessories (7) EXTENSIONS FOR LEGGINGS (6) LEGGINGS (10) 1 DERIVATION CONNECTION TUBE (11) ARMBAND (8) PRESSURE PLANTARS (12) ABDOMINAL BAND (9) 2 DERIVATIONS CONNECTION TUBE FOR LEGGINGS (13) SPECIAL SPLITTER FOR SIMULTANEOUS THERAPY ON BOTH LEGS AND ABDOMINAL BAND IACER SRL Page 7 di 24 MNPG102-04 04/02/16

Accessories size Legging: Length around 76 cm (from upper side to heel) Thigh circumference around 65 Ankle circumference around 38 cm Armband: Max. length around 86 cm Biceps circumference around 50 cm Wrist circumference around 36 cm Abdominal band: Abdominal around 136 cm Height around 46 cm Velcro height around 31 cm Extensions: Max. width around 13 cm Min. width around 6 cm IACER SRL Page 8 di 24 MNPG102-04 04/02/16

Configurations Power Q1000 Premium can be supplied in 5 different versions: POWER Q1000 PREMIUM TOT compressive limb therapy system comprising machine body, double legging (6), 2 derivations connection tube (9), 2 pressure plantars (8), armband (11), abdominal band (12), 1 derivation connection tube (10), special connector for simultaneous therapy on both legs and abdominal band (13). POWER Q1000 PREMIUM LEG2-ABD compressive limb therapy system comprising machine body, double legging (6), 2 derivations connection tube (9), 2 pressure plantars (8), abdominal band (12), 1 derivation connection tube (10), special connector for simultaneous therapy on both legs and abdominal band (13). POWER Q1000 PREMIUM LEG2 compressive limb therapy system comprising machine body, double legging (6), 2 derivations connection tube (9), 2 pressure plantars (8). POWER Q1000 PREMIUM LEG1 compressive limb therapy system comprising machine body, single legging (6), 1 derivation connection tube (10). POWER Q1000 PREMIUM ARM1 compressive limb therapy system comprising machine body, armband (11), 1 derivation connection tube (10). Extensions for wide legs (7) and special connector for simultaneous therapy on both legs and abdominal band (13) are available as accessories. Single accessories are available as optional to complete POWER Q1000 Premium content and potentiality. IACER SRL Page 9 di 24 MNPG102-04 04/02/16

Specifications POWER Q1000 Premium has the following specifications: Class IIa equipment (Directive 93/42/EEC, annexed IX, rule 9); Class II, applied part type BF (Classif. CEI EN 60601-1); CE0476 certificate; Equipment not protected against liquids penetration; Equipment and accessories not subjected to sterilization; Use of the equipment is prohibited close to flammable substances or in environments with high concentrations of oxygen; Continuous operating mode equipment; Equipment not suited to be used in external. Technical Specifications Power Supply 220-240 VAC, 50-60 Hz Therapy time Impostabile 5 99 min. Current 0,2 A Max pressure 240 mm Hg (±20%) Max output power 53W Weight Kg 2kg Purpose Clinical Purpose: Use: Therapeutic Clinic and domestic use IACER SRL Page 10 di 24 MNPG102-04 04/02/16

Working instructions Accessories use a) Leggings use i) Wear the leggings (or single legging) and close the zip up to the end, then close the retaining Velcro straps; in case of wide circumferences legs, connect the extensions available as accessories; ZIP VELCRO CONNECTION PLUGS ii) PRESSURE PLANTARS Insert the pressure plantars under the feet (available only with double leggings); iii) When wearing the leggings pay attention to position the tubes connection cables in the internal side of each legging; in single legging version connection cables position is not important; iv) Connect 4 tubes to the 4 plugs positioned on each legging, paying attention to connect the longer tube to the higher position connector (darker color) of legging (thigh); v) After connecting the tubes to the relatives leggings, connect the tubes to the air discharge output (5). IACER SRL Page 11 di 24 MNPG102-04 04/02/16

b) Abdominal band use CONNECTION PLUGS i) Wear the band and connect the tubes to the band plugs, paying attention to connect the longer tube to the higher position connector on abdominal band; ii) After connecting the tubes to the band, connect the tubes to the air discharge output (5). c) Simultaneous use of double leggings and abdominal band i) Connect the special splitter for simultaneous therapy (13) to the air discharge output (5). Then connect double leggings and abdominal band connectors to the splitter; ii) Wear the leggings (or single legging) and close the zip up to the end, then close the retaining Velcro straps; in case of wide circumferences legs, connect the extensions available as accessories; iii) Insert the pressure plantars under the feet (available only with double leggings); iv) When wearing the leggings pay attention to position the tubes connection cables in the internal side of each legging; in single legging version connection cables position is not important; IACER SRL Page 12 di 24 MNPG102-04 04/02/16

v) Connect 4 tubes to the 4 plugs positioned on each legging, paying attention to connect the longer tube to the higher position connector (darker color) of legging (thigh); vi) After connecting the tubes to the relatives leggings, connect the tube to the splitter connected to the air discharge output (13); vii) Wear the band and connect the tubes to the band plugs, paying attention to connect the longer tube to the higher position connector on abdominal band; viii) After connecting the tubes to the band, connect the tubes to the splitter connected to the air discharge output (13). b) Armband use i) Wear the armband and connect the tubes to the armband plugs, paying attention to connect the longer tube to the higher position connector (darker color) on armband; ii) After connecting the tubes to the armband connect the tubes to the air discharge output (5). Extensions use (optional) Extensions are available as optional to increase legging and/or armband circumference. Connect the extensions to the zip of the legging/armband (see the following imagine). IACER SRL Page 13 di 24 MNPG102-04 04/02/16

Working instructions 1. Connect cable to the domestic plug 220-240 VAC, then turn ON (1) the ON/OFF switch (1); 2. Select the parameters by pressing on MENU button. 3. Press on MOVE button to scroll the menu (MODE, PRESSURE TIME, INTERVAL, TIME (min), PRESSURE (mmhg)). 4. MODE. Select the program by pressing on SET button: MODE A 1 : Air flows in the first chamber (lower limb) according to adjusted pressure and sequentially in the other chambers in a distalproximal way. MODE A 2 : Air flows in the fourth chamber (upper limb) according to adjusted pressure and sequentially in the other chambers in a proximaldistal way. MODE B: Air flows in the first two chambers. When adjusted pressure is reached air flows in the last two chambers (distal-proximal way). MODE C: Air flows in the first chamber (lower limb) according to adjusted pressure and sequentially in the other chambers (distalproximal way ) by keeping swelled up the previous chamber every time. MODE D (1-2-3-4) : Air flows only in the selected compression chamber (mode D1 chamber 1 ; mode D2 chamber 2 ; mode D3 chamber 4 ; mode D4 chamber 4). MODE E (MODE A 1 + MODE C) : The machine runs two cycles in sequence. During the first cycle air flows in the first chamber (lower limb) according to adjusted pressure and sequentially in the other chambers in a distal-proximal way. At the end of the first cycle the machine starts the second cycle and air flows in the first chamber (lower limb) according to adjusted pressure and sequentially in the other chambers (distal-proximal way ) by keeping swelled up the previous chamber every time. IACER SRL Page 14 di 24 MNPG102-04 04/02/16

These two cycles are repeated in sequence till the end of duration of the treatment. 5. PRESSURE TIME: Select air flow speed by pressing SET buttons. You can choose 9 speed levels : 5,7,9,11,13,15,17,19,21 seconds. Default speed: 7 seconds. 6. INTERVAL: Select interval time by pressing SET buttons. You can choose 6 time intervals: 5,10,15,20,25,30 seconds. Default interval time 0 seconds. 7. TIME: Select time therapy by pressing SET buttons. Therapy time can be adjusted from 5 to 99 minutes. Default therapy time 15 minutes. We suggest to start with treatment of 10-15 minutes and increase it progressively according to your needs. Attention: It s not possible to change therapy time during the treatment. 8. PRESSURE: Select the pressure by pressing SET buttons. It is possible to adjust pressure for each compression chamber from 0 to 240 mmhg. Attention: Start the treatment with a middle pressure and increase it progressively according to your needs. 9. Press START/STOP button to start the therapy. Any moment it s possible to stop the treatment pressing again START/STOP button. 10.Press RESET the default settings. button to delete adjusted parameters and restore IACER SRL Page 15 di 24 MNPG102-04 04/02/16

Troubleshooting Problem Power Q1000 Premium doesn t switch on Power Q1000 Premium emits a strange sound like air leakage There is no pressure or the air Solution Check the connection to the domestic plug Check the ON/OFF button Check the power supply status (no sign of damages) Check the therapy time Check if there are any damages and/or holes in the tubes and connectors Check the applicators right connection to the main body Check if the tubes are pressed or bent Check the applicators right connection to the main body IACER SRL Page 16 di 24 MNPG102-04 04/02/16

doesn t go into the chambers Air goes into the compression chambers and/or an air leakage is present in the applicators Check if the tubes are pressed or bent Check if the compression chambers swell up in a progressive way Check if there are any holes or damages in the compression chambers. If there are not any air leakages, switch off the device then switch on it and recheck the right working ATTENTION: with POWER Q1000 Premium double leggings version, always connect both leggings to the connection tube even if you use only one legging during the treatment. IACER SRL Page 17 di 24 MNPG102-04 04/02/16

Warnings The following warnings guarantee user safety and prevention against damages and/or lesions. Please read it carefully before using Power Q1000 Premium. Warning In case of not following the instructions the user may suffer from serious injuries Caution In case of not following the instructions the user may suffer from serious injuries or device damages Indications Prohibition indication This is an indication for not disassembling Pay attention Disconnect the cable from domestic plug Warning Do not use the device in presence of acute inflammations or injuries. Infections risk Please consult the doctor in case of cancer, intestinal problems, fractures, acute thrombosis and other invalidating pathologies. IACER SRL Page 18 di 24 MNPG102-04 04/02/16

Do not use the device if you feel pain or bad feelings Do not exceed 20 minutes in the first treatments. We suggest to start with treatments of 5/10 minutes. Use only in consenting adults. Attention do not spill liquids or any substances on the device. Liquid penetration could damage the device. In case of suspected malfunctioning do not open or repair the device. Do not use the device. Electric shock risk. Contact the distributor or fabricant.. Do not connect or disconnect the device from domestic plug with wet hands. Electric shock risk. Use the device only with 220V power supply. Electric shock risk. Disconnect the device from domestic plug when not in use. Do not press, bend or damage the electric cable. Electric shock risk. Avoid to connect more devices to the same multiple plug. Overheating risk Avoid device hits or drops. IACER SRL Page 19 di 24 MNPG102-04 04/02/16

Caution Use the device only for expected purposes. Do not expose the device to the sun and do not storage it next to heat sources. Do not place any objects on the device or on its parts (connector tubes, applicators, etc.) If you not use the device for a long time or if you use the device in cold places, a malfunctioning may happen: make it operating by changing progressively the intensity for 3-4 times Clean the device using a dry soft cloth. Do not use cleaning solvents or other chemical substances in order to avoid any damages. Do not bend or tie the connection tubes. Use the device only for expected purposes. Product subject to WEEE regulations concerning separate waste collection of electronic equipment. IACER SRL Page 20 di 24 MNPG102-04 04/02/16

Cleaning Clean the device and its accessories using a soft cloth. Resistant stains can be removed using a sponge soaked in solution of water and mild soap. Wait for the complete drying before using the device and its accessories. Do not use chemical substances, solvents or cleaners to avoid device and accessories damage. Maintenance, carriage and storage If it is used in accordance with the instructions of the user manual, the device does not need a particular regular maintenance. Carriage precautions It doesn t need any particular carriage precautions: however we recommend to put away Power Q1000 Premium and its accessories in their own box after every treatment. Storage precautions Power Q1000 Premium is protected till following environmental conditions: Outside of the packaging temperature from +5 to + 40 C humidity from 30 to 80% pressure from 500 to 1060 hpa Inside of the packaging Temperature from 10 to +55 C Humidity from 10 to 90% pressure from 500 to 1060 hpa Disposal The equipment is subjected to WEEE regulations (see the symbol on the label) concerning separate waste collection: when disposing IACER SRL Page 21 di 24 MNPG102-04 04/02/16

this product, please use the designed areas for disposing electronic waste or contact the manufacturer. Assistance Every intervention on device must be performed by manufacturer. For any assistance intervention contact the national distributor or: I.A.C.E.R. S.r.l. Via S. Pertini, 24/a 30030 Martellago (VE) -ITALY Tel. 041.5401356 Fax 041.5402684 You can get any technical documentation on spare parts but only prior business authorization. Spare parts Contact the distributor or the fabricant for original spare parts at following address: I.A.C.E.R. S.r.l. Via S. Pertini, 24/a 30030 Martellago (VE) Tel. 041.5401356 Fax 041.5402684 To preserve product warranty, functionality and product safety we recommend to use only original spare parts. Warranty Make reference to the national laws for any warranty conditions by contacting the national distributor (or directly the manufacturer IACER). IACER SRL Page 22 di 24 MNPG102-04 04/02/16

POWER Q1000 Premium is manufactured by: IACER Srl is the mandatary nominated by the manufacturer in the European Community with regard to POWER Q1000 Premium. POWER Q1000 Premium is an exclusive distribution of IACER SRL. POWER Q1000 Premium. All rights reserved. Srl and is registered. logos is owned by I.A.C.E.R. IACER SRL Page 23 di 24 MNPG102-04 04/02/16