Cell Disruption System

Similar documents
User's Manual. MixRite TF 10. Edition 05.08

MULTICHANNEL. Labnet International, Inc.

Instruction Manual Updated 7/26/2011 Ver. 2.2

Helium-Oxygen Blender

Pipettor. User Manual

The University of Hong Kong Department of Physics Experimental Physics Laboratory

The pipettes cover a volume range from 0.1µl to 10ml.

mass of container full of air = g mass of container with extra air = g volume of air released = cm 3

RayPette Plus Autoclavable Pipette. User Manual

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &

Exercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C

Installation, Operation, and Maintenance Manual. Welker Constant Pressure Cylinder With Solid Indicator (Non-mixer) Model CP-30SI

Installation, Operation, and Maintenance Manual

Exercise 5-2. Bubblers EXERCISE OBJECTIVE DISCUSSION OUTLINE. Bubblers DISCUSSION. Learn to measure the level in a vessel using a bubbler.

Ammonia Treatment Instructions Page 1 of 5

Rejuvenation Instructions

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

Heat Engine. Reading: Appropriate sections for first, second law of thermodynamics, and PV diagrams.

P5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

CHEM 355 EXPERIMENT 7. Viscosity of gases: Estimation of molecular diameter

OPERATION MANUAL Please read this Operation Manual carefully before use, and file for future reference.

Installation of Your SprayMaster System

BioAerosol Nebulizing Generator. Operation and Maintenance User Manual

Register your instrument! Eppendorf Research plus. User Adjustment

Users Guide for the Vertical Bunsen Burner Test for Cabin and Cargo Compartment Materials FAA Handbook Chapter 2

PXRF- Tracer Helium Flow Control System

256 Pneumatic Pressure Indicator

PORTABLE 5 GALLON AIR TANK ASSEMBLY & OPERATING INSTRUCTIONS

Installation, Operation, and Maintenance Manual

Welker Constant Pressure Cylinders With Welker Solid Indicator, Syringe T-Handle, or Vortex Mixer

GILMONT ACCUCAL FLOWMETERS

VB85/ Pressure regulating valve (Unloader)

Radnoti Liver Perfusion System

Exp. 5 Ideal gas law. Introduction

Rev. A Jul 07 Part # SS VD510-SS INSTRUCTION MANUAL DISPENSING VALVE MODEL VD510-SS INSTRUCTION MANUAL

CALIBRATION AND ADJUSTMENT

Instruction Manual. Pipe Friction Training Panel

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

Installation, Operation, and Maintenance Manual

Rev. B Sept 06. VD510 INSTRUCTION MANUAL Part # DISPENSING VALVE MODEL VD510 INSTRUCTION MANUAL

1020 Industrial Drive, Orlinda, TN fax

ACV-10 Automatic Control Valve

Installation and Instructions 2. Product Features 3-6. Key Pad Functions 7. Distributor Information Programming Guide 8. Master Programming Guide 9-14

29 Pressure, Temperature relationship of a gas

Adjustable. Unloader Valve. O&M Manual. Part #

Chapter 2. Pipetting techniques. Guide to Pipetting

12S 1st Stage. -Maintenance Procedure-

Exploring the Properties of Gases. Evaluation copy. 10 cm in diameter and 25 cm high)

Air-Oxygen Blender. Service Manual. Model No. PM5200 Series PM5300 Series (shown)

CORESTA RECOMMENDED METHOD N 6

Douglas Call 4/11/2008 1/5. Ammonia Treatment

Boyle s Law VC 09. Experiment 9: Gas Laws. Abstract

MAINTENANCE OF THE HAND-OPERATED SIMPLE PUMP

Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems

Blaustein Atomizer (BLAM) Multi-jet Model. User s Manual

MB-SP Series Solvent Purification System

Exploring the Properties of Gases

Application and Sizing

Instruction Manual - Diaframless TM Ejector Chlorine, Sulfur Dioxide and Ammonia

Ideal gas law. Introduction

8. Carefully layout all the parts of the reservoir setup and clean any dirt, grime or dust from the parts. ( image 8 ) 8

Adjust the Volume Display

PIPETMAN F ENGLISH. Other languages available on our website:

Float Operated Level Controllers

300 Held Drive Northampton Pa

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

Before using or working with the Grab n Go Heliox system, please read and understand the usage and safety instructions provided in this booklet.

Calcimeter Instruction Manual

Installation Procedure for your Disco Double Kit, by Airgun Lab, LLC.

Students measure the change in pressure by varying the volume of trapped air in a syringe while:

PULSAR4 Pressure regulating valve (Unloader)

!!!! SERVICE MANUAL PRESSURE POT 2 GALLON. Service Manual: LT Washington St 931 Progress Ave., #7

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

Manual Solvent Purification System. Innovative Technology, Inc.

Operation Manual - PN A MENSOR MODEL 73 SHOP AIR BOOSTER

INSTRUCTION MANUAL FOR MODEL 7360V VERTICAL CURING CHAMBER Revision E May

Superconducting Susceptometer (MPMS-5S) Quantum Design Room 296 (MPMS)

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

Vapor Pressure of Liquids

BPS-2, Rev TABLE OF CONTENTS

CHEMICAL ENGINEERING LABORATORY CHEG 239W. Control of a Steam-Heated Mixing Tank with a Pneumatic Process Controller

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

Paintball Marker. User s Manual. 530 South Springbrook Road Newberg, OR 97132

Introduction. Objectives. Hazards. Procedure

Agilent ICP-MS Interactive Troubleshooting tool for Low sensitivity

PNEUMATIC PRESSURE CONTROLLERS

User s Manual. Autoclavable & UV resistant. Multi-channel digital micro pipette. In Vitro Medical Diagnostic Devices (98/79/EC)

LEAK SEALING SYSTEMS

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER CONSTANT PRESSURE CYLINDER

OPERATION MANUAL NTF-15

Product Information News September 26, 2003

Agilent 1290 Infinity Pump Head Maintenance

Chemical Injection Technologies Installation/Service Bulletin

Introduction. Part one: Identify the Hydraulic Trainer Components

Air Saving Valve reduction in 40% air consumption 40% air consumption Air consumption reduction ratio (%) Flow valve Flow valv

MEMORIAL UNIVERSITY OF NEWFOUNDLAND Faculty of Engineering and Applied Science FLUID MECHANICS LABORATORY PIPE FRICTION

DS06D,G Dial Set Pressure Regulating Valve

Yoke Block Instruction Manual

ASE SOLVENT CONTROLLER INSTALLATION INSTRUCTIONS Dionex Corporation

PULSAR4 Pressure regulating valve (Unloader)

Transcription:

BioNeb Cell Disruption System* Instruction Manual * U.S. patent number 550100 International patents issued and pending

BioNeb Cell Disruption System Instruction Manual Version 3.0, April, 2000 Edited by: Robert K. Togasaki Stefan J. Surzycki Designed and Developed by: H. Kay Yokota C 1992, 1993, 1994 Indiana University Bloomington, Indiana All rights reserved under Federal Copyright Legislation. No part of this book may be reproduced in any form, without permission in writing from the publisher. Under no circumstance is permission granted for reproduction, including photocopying, for commercial purposes or resale. BioNeb is a registered trademark of Glas-Col. The BioNeb Cell Disruption System is manufactured and serviced by: Glas-Col 711 Hulman Street PO Box 2128 Terre Haute, Indiana 47802-0128 USA Tel: 812-235-17 Fax: 812-234-975 Toll Free: 800-452-725 E-Mail: pinnacle@glascol.com Internet: www.glascol.com

Table of Content Cell Disruption Introduction Principles Of Nebulization...1 What s In This Manual...2 Part I. Part II. Part III. Part IV. Part V. Description Of The Instrument Contents Of BioNeb Kit...3 Additional Items Required...3 Assembly Step 1: Base Assembly...4 Step 2: Cylinder Attachment...5 Step 3: Top Adjustment (1)...5 Step 4: Top Attachment... Step 5: Top Adjustment (2)... Calibration Step 1: Gas Tank Setup...7 Step 2: Gas Flow Adjustment...7 Operation Method Of Operation...9 Method 1: Closed-Drain Single Cycle Mode...10 Method 2: Open-Drain Single Cycle Mode...11 Method 3: Open-Drain Recycling Mode...12 Detachment And Cleaning Detachment And Cleaning...14 Appendixes For Cell Disruption Appendix A: Feature Diagram...15 Appendix B: Worksheet...18 Appendix C: Technical Support Data...19 Appendix D: Tips For Optimal Operation...21 BioNeb Cell Disruptor Instruction Manual I

Introduction Principle of Nebulization Breaking living cells, isolating cell organelles, and fragmenting large molecules are three standard procedures used daily in research and industrial laboratories. The BioNeb Cell Disruption System is an instrument that nebulizes liquid (i.e., reduces liquid to a fine spray) to generate uniform shearing forces that can break cells and molecules. In the process of droplet formation, large molecules or cells suspended in the liquid being nebulized are forcefully distributed from the liquid into the forming droplet. This creates a transient laminar flow in the microcapillary channel formed between the surface of the liquid and the forming droplet. The laminar flow in the capillary channel exerts sufficient shearing forces to break cells and large rigid molecules. We call this capillary channel a nebulization channel and the process of shearing afforded by the formation of this channel, nebulization shearing. The extent of the shearing force created is proportional to the pressure drop described by the equation of liquid capillary flow. Accordingly, this force is directly proportional to the gas pressure applied and the viscosity of the liquid, and inversely proportional to the size of the droplets. Droplet size can be regulated by gas pressure. The kind of gas used also has an influence on the size of the droplet. Under identical pressure, size of droplets will decrease in following order of gasses used: Argon, Nitrogen, Helium. Thus, the same instrument can be used for very gentle opening of the cell as necessary in organelle isolation, or for thorough breakage of the cells, when preparation of a cell extract is desired. Because the size of the formed droplets is very uniform, the applied force is also very uniform resulting in highly efficient cell or molecule breakage. Breaking cells or shearing molecules in the BioNeb cell disruptor does not generate heat and is achieved in a steady-state manner. Shearing or breakage does not depend on the length of time the shearing forces is applied but only on the magnitude of the force applied i.e., the size of the droplets generated. The operation of this apparatus is simple, rapid, and highly reproducible, as described in the following pages. BioNeb Cell Disruptor Instruction Manual 1

Introduction What's in this Manual This manual provides step-by-step procedures for assembly and operation of the BioNeb Cell Disruption System and brief explanations about its features. Technical support data is also included. Sections Specific to Cell Disruption Part I (Description of the Instrument) presents the contents of the BioNeb cell disruptor kit and additional items required to operate the apparatus. Part II (Assembly), Part III (Calibration), and Part V (Detachment and Cleaning) provides step-by-step instructions for each activity. Part IV (Operation) presents details about three methods of operation of the BioNeb system. The appendices contain supplementary information to help you understand the BioNeb system further. Appendix A (Feature Diagram) illustrates the function of each component of the unit. Appendix B (Worksheet) provides an example of a worksheet that might be convenient while you operate the system. Appendix C (Technical Support Data) includes a table presenting the typical distance between the Ball and the Nozzle Cap surface that will produce good misting. Appendix D (Tips for Optimal Operation) deals with tips to avoid potential problems you might face during your operation of the BioNeb cell disruptor. About icon Throughout the manual you will see an icon of the BioNeb disruptor to help you understand which part of the apparatus is being discussed. The white part of the icon is intended to draw your attention to the part under discussion. 2 BioNeb Cell Disruptor Instruction Manual

Part I. Description of the Instrument Contents of BioNeb Kit (105A BN3015) 1. Instrument Base 2. Gas Tube 3. Set of Short Inlet and Outlet Tubes 4. Set of Long Inlet and Outlet Tubes 5. Top. Cylinder 7. Reservoir 8. Base 9. Nozzle Cap 10.Flowmeter 1 3 4 2 5 7 9 8 10 Additional Items Required Gas tank (Nitrogen, Helium or Argon) with pressure regulator. Small beakers (several). BioNeb Cell Disruptor Instruction Manual 3

Part II. Assembly Step 1: Base Assembly 1.1 1.1. Take the base, place the spacer on the nozzle and center it. Screw on the nozzle cap until it stops turning. Do it by hand. Never use a wrench because the nozzle cap might freeze on the nozzle! 1.2 1.2. Close the drain by turning the drain regulator clockwise until it stops. 1.3. Insert the long inlet tube into the liquid inlet and the short drain tube into the drain outlet. Note: There are two sets of tubes. The shorter set is for use with reservoir and the longer set is for use with beakers. The tip of the inlet tube is cut as shown in order to facilitate liquid uptake. 1.3 1.4. Insert the holder rod into the opening of the universal instrument positioner. 1.4 4 BioNeb Cell Disruptor Instruction Manual

Part II. Assembly Step 2: 2.1 Cylinder Attachment 2.1. Insert the cylinder into the base so that each pin rests on the side of the base. Twist the cylinder until pins are directly above the vertical slots. Push the cylinder down. Twist the cylinder until the pins enter the horizontal slots. Note: The small volume cylinder is attached similarly, but it must be positioned right side up. Step 3: 3.1 Top Adjustment 3.1. Pick up the top. With the ball securely attached, rotate the umbrella counterclockwise until it stops. Now rotate the umbrella clockwise for 11 full turns. Note: The tightness of rotation of the ball height adjustment disk can be changed. See Appendix A for details. BioNeb Cell Disruptor Instruction Manual 5

Part II. Assembly Step 4: Top Attachment 4.1 4.1. Insert the top into the cylinder so that each pin rests on the side of the base. Twist the top until pins are directly above the vertical slots. Push the top down. Twist the top until the pins enter the horizontal slots. The gas outlet should face away from the operator. The apparatus should be used in a chemical or a laminar flow hood. Step 5: Top Adjustment 5.1 5.1. Watch the ball while you rotate the ball height adjustment disk clockwise slowly until the ball comes in contact with the nozzle cap surface. Stop as soon as you feel resistance. This is zero position for ball height or BH0. Note: BH0 will change each time the BioNeb is reassembled. Gas Tube Insertion Do not force rotation of the nozzle beyond zero position of the ball. You will dent the surface of the nozzle cap. Push the gas tube into the sleeve at the gas inlet of the base. Pull on the gas tube to make sure that the connection is secure. This completes assembly. In order to remove the gas line, pull it while pushing in the sleeve of the gas inlet. The BioNeb is now assembled and ready for calibration. BioNeb Cell Disruptor Instruction Manual

Part III. Calibration Step 1: Gas Tank Setup 1.1 1.1. Open the gas tank valve and adjust the pressure (e.g., 100 psi). 1.2. Turn the delivery valve 45 from closed position, and note the rapid gas back-flow coming out of the inlet tube. (You can feel it easily with your wet finger.) 1.2 Note: The delivery valve opening can be set differently according to your need. Step 2: Gas Flow Adjustment 2.1 2.1. Rotate the ball height adjustment disk counterclockwise until gas backflow stops. BioNeb Cell Disruptor Instruction Manual 7

Part III. Calibration 2.2. When the back flow is no longer felt with a wet finger, you can place a small beaker, half filled with water, beneath the liquid inlet tube. Observe the ripple on the water surface caused by the backflow. Rotate the ball height adjustment disk counterclockwise until the water surface is no longer disturbed. 2.2 2.3. Immerse the tip of the liquid inlet tube in the water in the beaker and observe slow bubbling. Rotate the disk further until no more bubbles come out. This is the no bubble position for ball height or BHnb. 2.3 2.4. Continue to rotate the adjustment disk counterclockwise 4 to units on the calibration disk (one unit corresponds to 5 ). This should give good misting and active upward movement of liquid through the inlet tube. 2.4 2.5. Turn off the gas tank valve. Turning gas flow on and off with gas tank valve leaves the delivery valve setting constant. This completes the calibration. 2.5 8 BioNeb Cell Disruptor Instruction Manual

Part IV. Operation Methods of Operation The BioNeb can be operated in three different ways: Method 1: Closed-Drain Single Cycle Mode (Batch Operation) Method 2: Open-Drain Single Cycle Mode (Batch Operation) Method 3: Open-Drain Recycling Mode (Continuous Operation) Note: Use the short set of tubes for the BioNeb disruptor reservoir, and the long set of tubes when using beakers. BioNeb Cell Disruptor Instruction Manual 9

Part IV. Operation Method 1: Closed-Drain Single Cycle Mode 1.1. Place sample solution in the reservoir. 1.1 1.2. Insert the reservoir into the base so that each pin rests on the side of the base. Make sure that the short set of tubes is attached. Twist the reservoir until pins are directly above the vertical slots. Push the reservoir up. Twist the reservoir until the pins enter the horizontal slots. Turn on the gas tank valve. Adjust the ball height adjustment disk, if necessary, to obtain good misting. The initial setting with water may not be optimal for the sample solution. This is BHexp position (see Appendix C for further explanation). 1.2 After all the sample solution is transferred, turn off the gas tank valve. 1.3. Open the drain by turning the drain regulator counterclockwise 30 (one full turn). 1.3 Note: For multi-cycle operation, repeat steps 1.3 to 1.5. Detach the reservoir and collect the sample. 10 BioNeb Cell Disruptor Instruction Manual

Part IV. Operation Method 2: Open-Drain Single Cycle Mode 2.1. Open the drain by turning the drain regulator counterclockwise 30 (one full turn). 2.1 2.2 2.2. The inlet tube is inserted into the sample solution while the drain tube is inserted into the beaker. Make sure that the long set of tubes is attached. Turn on the gas tank valve. Adjust the ball height adjustment disk, if necessary, to obtain good misting. The initial setting with water may not be optimal for the sample solution. This is BHexp position (see Appendix C for further explanation). 2.3. With good misting, sample solution should be transferred to the product beaker. 2.3 When all the sample solution is transferred to the product beaker, turn off the gas tank valve. Note: For multiple-cycle operation, repeat the steps 2.2 to 2.5. BioNeb Cell Disruptor Instruction Manual 11

Part IV. Operation Method 3: Open-Drain Recycling Mode 3.1. Open the drain by turning the drain regulator counterclockwise 30. Use the short set of tubes for the reservoir and the long set of tubes for the beaker. 3.1 3.2. Place the sample solution into the reservoir (or beaker). 3.2 3.3 3.3. Insert the reservoir into the base so that each pin rests on the side of the base. Make sure that the short set of tubes is attached. Twist the reservoir until pins are directly above the vertical slots. Push the reservoir up. Twist the reservoir until the pins enter the horizontal slots. 12 BioNeb Cell Disruptor Instruction Manual

Part IV. Operation 3.4. Turn on the gas tank valve. Adjust the ball height adjustment disk, if necessary, to obtain good misting. The initial setting with water may not be optimal for the sample solution. This is BHexp position (see Appendix C for further explanation). 3.4 Nebulize for a given period (e.g., 5 minutes) and then turn off the gas tank valve. Twist the reservoir until pins are directly above the vertical slots. Push the reservoir down. Detach the reservoir and collect the sample. BioNeb Cell Disruptor Instruction Manual 13

Part V. Detachment and Cleaning 1. Make sure that both the main gas valve and the delivery valve are closed. 2. Remove the gas line by pulling it while pushing into the sleeve of the gas inlet. 3. Detach the top, rinse and dry. (Ethanol can be used but not acetone!) 4. Detach the cylinder, rinse and dry. 5. Unscrew the nozzle cap from the base, remove the spacer, rinse and dry.. Rotate the knob of the universal instrument positioner counterclockwise and detach the base from the positioner, rinse and dry. Make sure that both liquid and gas passages are clear. 7. Detach liquid inlet tube and drain tube, rinse and dry. It is recommended that all components of the BioNeb be stored clean and dry. Do not leave the instrument not cleaned after usage. 14 BioNeb Cell Disruptor Instruction Manual

Appendix A Feature Diagram BioNeb Cell Disruptor - Top 1. The Ball is detached from the Ball Height Adjustor Rod. 2. The Umbrella is removed from the Ball Height Adjustor Rod. 3. The tightness of rotation of the Ball Height Adjustment Disk can be adjusted by changing the tightness of the Tightness Screw: (a) Turn three Phillips Screws by using a hexa-wrench. The Ball Height Adjustment Disk is detached from the Calibration Disk. (b) Turn the Tightness Screw on the Calibration Disk to apply pressure on the O-ring. Alteration of the O-ring shape will change the tightness of rotation. BioNeb Cell Disruptor Instruction Manual 15

Appendix A Feature Diagram BioNeb Cylinder (large volume) BioNeb Base 4. Drain Regulator Operation: 1 BioNeb Cell Disruptor Instruction Manual

Appendix A Feature Diagram BioNeb Reservoir BioNeb Cell Disruptor Instruction Manual 17

Appendix B Worksheet Date: Objective: Organism: Protocol: Exp. No. No. of Cycles Type of Gas PSI Gas Delivery Valve Turn BH0 BHexp DBH (BH exp - BH 0 ) Experiment Notes 1 2 3 4 5 7 8 9 10 11 12 13 14 15 Initial gas tank pressure: Final gas tank pressure: 18 BioNeb Cell Disruptor Instruction Manual

Appendix C Technical Support Data The difference between BHexp and BH0 (BHexp - BH0) is DBH which is the indicator of distance between the Ball and the Nozzle Cap surface. This number should be relatively constant for a given experimental setting; i.e., under the same gas pressure. For your convenience, the top of the Calibration Disk is divided into 72 engraved lines, with tick marks at every 10 lines, except between line 70 and line 72/0. It is recommended that each tick line be numerically marked (0, 10, 20,... 70), for easy identification. BioNeb Cell Disruptor Instruction Manual 19

Appendix C Technical Support Data Table. Typical Distance Between the Ball and the Nozzle Cap Surface Solution Nebulized Type of Gas Gas Pressure (psi) Gas Delivery Valve Turn ÐBH BH 0 * BH nb BH exp (BH exp - BH 0 ) (BH exp - BH nb ) Yeast Helium 200 psi 150 100 50 1/8 turn 33 4 43 50 1 0 58 58 7 4 4 34 20 21 14 Yeast Nitrogen 200 psi 150 100 50 1/8 turn 27 2 28 25 14 5 0 53 20 71 59 5 45 38 34 Yeast Argon 200 psi 150 100 50 1/8 turn 21 25 30 28 5 0 55 0 71 1 51 4 3 33 * BH 0 will change each time when the BioNeb is reassembled. Alternative Regulation of Gas Flow by a Flow Meter Theoretically, the efficiency of nebulization should be proportional to the flow rate of gas exiting from the nozzle. In practice, the efficiency of cell breakage with helium, nitrogen and argon have shown a linear relationship with gas flow rate within certain ranges. Furthermore, one can control gas flow rate more precisely with a flow meter. With Cole Parmer flow meter #054-17ST, we carried out 3 cycles of nebulization of yeast cell suspension under 200 psi and found the following ranges of gas flow rate that give proportional cell breakage. Helium Nitrogen Argon (10,000 ml/min. to 20,000 ml/min.) (2,500 ml/min. to 8,500 ml/min.) (2,500 ml/min. to,500 ml/min.) 20 BioNeb Cell Disruptor Instruction Manual

Appendix D Tips for Optimal Operation Potential Problem: Instead of good smooth misting, spattering occurs. Solution: Clean the nozzle opening, as well as the nozzle cap opening regularly. Potential Problem: Variable gas pressure might decrease the efficiency of cell breakage. Potential Problem: The drain regulator might become hard to turn. Solution: Apply stopcock grease to the thread of the Drain Regulator regularly. Make sure that stopcock grease does not reach beyond the O- ring. Solution: Check the gas pressure remaining in the tank. Potential Problem: Loose coupling of pins and slots of the Base and the Cylinder might cause a liquid leak. Solution: Check the tightness of the coupling between the base and the cylinder. If necessary replace O-rings with new ones. Potential Problem: Insufficient seal might develop a gas leak at the gas inlet during operation. Solution: Reseal the gas inlet with fresh Teflon resin thread seal tape. WARNING: 1. Do not open gas tank valve before the gas tube is inserted into the BioNeb system. 2. Operate the BioNeb disruptor in a chemical hood to avoid contamination of laboratory space by nebulized materials. BioNeb Cell Disruptor Instruction Manual 21