Using Hexoskin Wearable Technology to Obtain Body Metrics During Trail Hiking

Similar documents
Assessment of an International Breaststroke Swimmer Using a Race Readiness Test

JEPonline Journal of Exercise Physiologyonline

External Feedback Does Not Affect Running Pace in Recreational Runners

Anaerobic and aerobic contributions to 800 m and 8 km season bests

Article published in: ACSM s Medicine & Science in Sports & Exercise Vol. 27, No. 4, April 1995

Validation of a Step Test in Children Ages 7-11

A Description of Variability of Pacing in Marathon Distance Running

A Re-Examination of Running Energetics in Average and Elite Distance Runners

Current State of Commercial Wearable Technology in Physical Activity Monitoring

The Optimal Downhill Slope for Acute Overspeed Running

Journal of Exercise Physiologyonline (JEPonline)

1 June Presented by: Jeff Kiley Risk Management Directorate Program Executive Office Assembled Chemical Weapons Alternative

MINERVA MEDICA COPYRIGHT

Personal air pollution exposures in NYC bicycle commuters: Evidence from the Biking & Breathing study

The Energy Cost of Nordic Walking

Journal of Exercise Physiologyonline

#10 Work Physiology. By : Dewi Hardiningtyas, ST., MT., MBA. Industrial Engineering Dept. University of Brawijaya

Name Date of Data Collection. Class Period Lab Days/Period Teacher. Measuring Lung Capacity

A CROSS-SECTIONAL ANALYSIS OF SKILL RELATED PHYSICAL FITNESS COMPONENTS OF KAYAKING AND ROWING PLAYERS

Oxygen Uptake and Energy Expenditure during Treadmill Walking with Masai Barefoot Technology (MBT) Shoes

Practical aspects of tapering for competition in athletics. Iñigo Mujika

Measuring Lung Capacity

The Reliability of a Laboratory-based 4 km Cycle Time Trial on a Wahoo KICKR Power Trainer

HOW MANY DAYS A WEEK WILL I NEED TO RUN?

University of Pretoria

Ref. no Altitude functions

Ref. no FUNCTIONS AND FEATURES

Comparison of Ventilatory Measures and 20 km Time Trial Performance

SC.5.P.13.2 Investigate and describe that the greater the force applied to it, the greater the change in motion of a given object.

The role of fitness testing in the evaluation of primary school running programmes

Variability of pacing in marathon distance running

2nd International Conference on Management Science and Industrial Engineering (MSIE 2013)

Fitbit s 100+ Billion Hours of Resting Heart Rate User Data Reveals Resting Heart Rate Decreases After Age 40

Load dynamics of joints in Nordic walking

Changes in a Top-Level Soccer Referee s Training, Match Activities, and Physiology Over an 8-Year Period: A Case Study

ALTITUDE TRAINING FOR IMPROVING SWIMMING PERFORMANCE AT SEA LEVEL. MITSUMASA MIYASHITA, YOSHITERU MUTOH and YOSHIHARU YAMAMOTO.

Monitoring of performance an training in rowers


Analysis of performance and age of the fastest 100- mile ultra-marathoners worldwide

THEORY OF TRAINING, THEORETICAL CONSIDERATIONS WOMEN S RACE WALKING

Congress Science and Cycling 29 & 30 june 2016 Caen. Théo OUVRARD, Julien Pinot, Alain GROSLAMBERT, Fred GRAPPE

Submaximal Treadmill Exercise Test to Predict VO 2 max in Fit Adults

VALIDITY OF SELECTED CARDIOVASCULAR FIELD-BASED TEST AMONG MALAYSIAN HEALTHY FEMALE ADULT. S. H. Azmi 1,*, and N. Sulaiman 2

Changes in Relative Exercise Intensity during a Two Hour Endurance Race Using a Tandem-Bicycle for Exercise

EXAMINING THE RELABILITY AND VALIDITY OF THE FITBIT CHARGE 2 TECHNOLOGY FOR HEART RATE DURING TREADMILL EXERCISE

NATIONAL STEPS CHALLENGE TM SEASON 4 STEP UP TO TAKE OFF WITH SINGAPORE AIRLINES GROUP CHALLENGE FREQUENTLY ASKED QUESTIONS

Is lung capacity affected by smoking, sport, height or gender. Table of contents

Gait Analysis System. User Manual and Outcome parameters Patent WO2012/ A1

Oral versus Nasal Breathing during Moderate to High Intensity Submaximal Aerobic Exercise

SPRINTING CHARACTERISTICS OF WOMEN S 100 METER FINALS AT THE IAAF WORLD CHAMPIONSHOPS DAEGU 2011

The Influence of Elliptical Chainrings on 10 km Cycling Time Trial Performance

On a track where the goal is to run a given distance

Heart rate response to a climber s fall in sport climbing

COMPARISON OF PHYSIOLOGICAL VARIABLES AND BODY COMPOSITION VARIABLES AMONG WALKING TYPES ON TREADMILL

ABSTRACT THE INFLUENCE OF BODY COMPOSITION ON CADENCE EFFICIENCY IN COMPETITIVE CYCLISTS. by Tate Bross Devlin

Grip Force and Heart Rate Responses to Manual Carrying Tasks: Effects of Material, Weight, and Base Area of the Container

For this investigation, I expect to find that as exercise intensity increases, so too will heart rate and ventilation rate.

Innovation Report. Physiological and Biomechanical Testing of EasyPedal Pedal Prototypes. Jan 2012

R ecent developments in field hockey, such as the artificial

LEVEL OF VO2 MAX CAPACITY VOLLEYBALL PLAYERS

Walking for Heart Health in Rural Women

Chapter 5 Is gross efficiency lower at acute simulated altitude than at sea level?

Procedia Engineering Procedia Engineering 2 (2010)

Journal of Human Sport and Exercise E-ISSN: Universidad de Alicante España

Fitness Assessment Form

Influence of Angular Velocity of Pedaling on the Accuracy of the Measurement of Cyclist Power

The Match Demands of Australian Rules Football Umpires in a State-Based Competition

Vertical hand force and forearm EMG during a High-step Rock-on climbing move with and without added mass

Club coureurs CHALEUR road runners club Club cycliste CHALEUR cycling club

How Running Barefoot (Xero Shoes) and Running Shod (Montrail Shoes) Effects Percent of Maximum Heart rate - A Case Report

A Comparison of Observed Collegiate Female Cyclists to Elite Female Cyclists from a Meta-Analytic Review

Article Title: Relationships Between Triathlon Performance and Pacing Strategy During the Run in an International Competition

The Effects of Hiking Poles on Performance and Physiological Variables During Mountain Climbing

The Physical and Physiological Characteristics of 3x3. Results of Medical Study & Scientific Test

By Seth Schutte, John Amtmann, Harris Cody and William Spath. Intermountain Journal of Sciences

University of Canberra. This thesis is available in print format from the University of Canberra Library.

The effect of the Gravity-Loading Countermeasure Skinsuit (GLCS) upon aerobic exercise performance

16. How to analyze Stryd data: Example of 10K Road Race

Exploring the relationship between Heart Rate (HR) and Ventilation Rate (R) in humans.

Comparison of Three Tests for Assesing the Aerobic Aptitude to the Elite Swimmers

Contact person: Aitor Coca address:

Body Mass Bias in a Competition of Muscle Strength and Aerobic Power

HHS Public Access Author manuscript Int J Cardiol. Author manuscript; available in PMC 2016 April 15.

Women s hockey players have been competing. Prediction of Ice Skating Performance With Off- Ice Testing in Women s Ice Hockey Players

Validity of wrist-worn consumer products to measure heart rate and energy expenditure

HOME BLOOD PRESSURE KIT INSTRUCTIONS TRILINGUAL INSTRUCTION GUIDE MODEL UA-100

Applying Hooke s Law to Multiple Bungee Cords. Introduction

Validity and Reproducibility of the Garmin Vector Power Meter When Compared to the SRM Device

Comparing Garmin Forerunner 405CX GGP and Nike + ipod to Accurately Measure Energy Expenditure, Distance, and Speed of Overground Running

Impulse Lab Write Up. K leigh Olsen. 6th hour

EFFECTS OF SYNCHRONOUS MUSIC ON PSYCHOLOGICAL RESPONSES, PERFORMANCE INDICES AND PHYSIOLOGICAL FUNCTIONING AMONG ELITE TRIATHLETES AND RUNNERS

Factors Affecting Phonotaxis in Male House Crickets, Acheta domesticus

Report for Experiment #11 Testing Newton s Second Law On the Moon

The Yo-Yo Test: Reliability and Association With a 20-m Shuttle Run and VO 2max

Physiological Assessment: Summary Report 11 December 2011

Validity and Reliability of Predicting Maximum Oxygen Uptake via Field Tests in Children and Adolescents

Relationship between Ground Reaction Force and Stability Level of the Lower Extremity in Runners Background: Objective: Design and Setting:

Crawley, Western Australia, AUSTRALIA; 2 School of Mathematical Sciences, The University of Western Australia, Crawley, Western Australia, AUSTRALIA

How Running Barefoot (Xero Shoes) and Running Shod (Montrail Shoes) Effects Percent of Maximum Heart rate - A Case Report

INSTRUCTION MANUAL. Automatic Blood Pressure Monitor with Fit Cuff. =Fit Cuff=!"#$% IA1B. Model

Transcription:

Technical Note Using Hexoskin Wearable Technology to Obtain Body Metrics During Trail Hiking JEFF MONTES 1, TORI M. STONE 1, JACOB W. MANNING 2, DAMON MCCUNE 1, DEBRA K. TACAD 1, JOHN C. YOUNG 1, MARK DEBELISO 2, and JAMES W. NAVALTA 1 1 Department of Kinesiology and Nutrition Sciences, University of Nevada, Las Vegas, Las Vegas, NV, USA; 2 Department of Physical Education & Human Performance, Southern Utah University, Cedar City, UT, USA Denotes graduate student author, Denotes professional author ABSTRACT 8(4): 425-430, 2015. Use of wearable technology to obtain various body metrics appears to be a trending phenomenon. However there is very little literature supporting the notion that these apparatuses can be used for research purposes in the field. The purpose of this study was to utilize Hexoskin wearable technology shirts (HxS) to obtain data in a pilot study using a trail hiking situation. Ten individuals (male, n = 4, female n = 6) volunteered to participate. On the first day, volunteers completed two approximately flat trail hikes at a self-preferred pace with a 15- minute rest between trials. On the second day, participants completed a strenuous uphill hike (17.6% grade) with a 15-minute rest at the summit and then completed the downhill portion. Body metrics provided by the HxS were average heart rate (HR), maximal HR (MHR), total energy expenditure (EE), average respiratory rate (RR), maximal respiratory rate (MRR), total steps (SC), and cadence (CA). Other measurements obtained were systolic and diastolic blood pressure (SBP, DBP), and ratings of perceived exertion (RPE). Data were analyzed using both one-way repeated measures analysis of variance (ANOVA) with significance accepted at p 0.05 and intraclass correlation coefficients (ICC) for each variable. Both were determined using Statistical Package for the Social Sciences software (SPSS). No significant differences for trail type were noted for MHR (p=0.38), RR (p=0.45) or MRR (p=0.31). The uphill trail elicited significantly elevated HR (up=154±24 bpm, easy=118±11 bpm, down=129±19 bpm; p=0.04) and EE (up=251±78 kcal, easy=124±38 kcal, down=171±52 kcal; p=0.02). Significant ICC were observed for DBP (r = 0.80, p = 0.02), RR (r = 0.98, p = 0.01), SC (r = 0.97, p = 0.01) and RPE (r = 0.94, p = 0.01). Non-significant correlation were noted for uphill RR vs CA (r=0.51, p=0.16) or RPE vs SBP (r=0.03, p=0.94), HR (r=0.60, p=0.12), and MHR (r=0.70, p=0.051). We utilized HxS to provide physiological data in an applied setting. It should be noted that HR did not register in 5 out of 10 subjects on the easy trail, and 8 of 10 participants during the uphill hike. Additionally, estimated EE appears to be linked to HR intensity. Future investigations taken in an outdoor environment should take these findings into consideration. KEY WORDS: Attire, devices, trek, outdoor activity INTRODUCTION Utilizing wearable technology to obtain body metrics is a trending phenomenon (3, 5). The ease of obtaining individual measures makes wearable technology an attractive option, however, there is very little literature supporting the notion that these apparatuses can be used for field research.

Hexoskin wearable technology shirt (HxS) is designed to measure several physiological variables including heart rate (HR), respiratory rate (RR), total energy expenditure (EE), and total steps (SC). In a laboratory-based investigation, the validity of this technology was compared with standard laboratory equipment at intensities up to 80% of the estimated MHR. Minimal variability was reported and consistency was accepted (4). While there is evidence the HxS may be valid and reliable in a controlled laboratory setting, its application in an outdoor environment is largely unknown. Therefore, the purpose of this study was to utilize HxS technology to obtain data in various trail hiking situations. We used this opportunity as a means to pilot test the Hexoskin for collecting data in a real-life, outdoor setting. METHODS Participants Ten individuals (male n = 4, female n = 6) volunteered to participate (age = 24±10 years, height = 1663 cm, mass = 65±18 kg). Prior to involvement in the study, participants provided informed consent that was approved by the institutional review board (Southern Utah University protocol #13-092014). Protocol The protocol was a modification of a previous investigation completed by our research group (2). On the first day, volunteers completed two easy (class I, Yosemite Decimal System (YDS)) 1.82 km (1.13 mile) trail hikes at a self-preferred pace with a 15-minute rest period between 426 trials. Altitude was measured at 5,446 feet above sea level (4400 Heat Stress Tracker, Kestrel, Boothwyn, PA). Body metrics provided by the HxS (Hexoskin Smart Shirt, Montreal, Canada) were HR, MHR, EE, RR, MRR, SC and cadence (CA). The HxS collects data through a data collection device (DCD) that connects by a plug to the shirt itself. Measurements begin when the DCD is attached and stop when disconnected. The HxS DCD was connected when the subject began the easy trail hike and was disconnected when they reached the finish point. Systolic blood pressure (SBP), diastolic blood pressure (DBP) and ratings of perceived exertion (RPE) was also taken. SBP and DBP were measured with an automatic blood pressure device (Omron, BP742, Kyoto, Japan). RPE utilized the Borg scale of 6-20. SPB, DBP, and RPE was taken at the very beginning (directly before HxS activation) and immediately at the finish for both easy trail hikes (directly after the HxS was disconnected) (1). On the second day, participants completed a strenuous (class I, Yosemite Decimal System (YDS)) 1.82 km (1.13 mile) uphill hike (17.6% grade). After a 15-minutes rest period at the summit, subjects completed the downhill portion. Initial elevation was 5,757 feet above sea level, and rose to 6,443 feet at the summit. HxS, SPB, DBP, and RPE measurements were taken at the beginning and end of both stages of the strenuous trail hike in a similar manner as the easy trail hikes. Statistical Analysis The dependent variables of average HR, Maximal HR, estimated calories, average breathing rate, maximal breathing rate, steps, cadence and RPE were analyzed

between trail type (initial easy trail, strenuous uphill, strenuous downhill) using one-way repeated measures analysis of variance (ANOVA) (SPSS, ver. 21.0, Chicago, IL, USA) with significance accepted at p 0.05. Intraclass correlation coefficients (ICC) for each of the previously listed dependent variables as well as SBP, DBP, and RPE were determined using the Reliability Analysis: Intraclass Correlation Coefficient option (two-way mixed model, absolute agreement type) in SPSS. ICC s were considered significant at the p 0.05 level. Pearson product moment correlation coefficients (r) were determined for each trail condition for relationships between RPE and the dependent variables of SBP, HR, and MHR; and between cadence and RR in SPSS using the bivariate correlation option and significance was accepted at p 0.05. RESULTS Preferred hiking speed uphill was significantly slower (4.54±0.64 km h -1 ) than the easy trail (5.84±0.45 km h -1, p<0.001) as well as on the downhill portion of the strenuous trail (5.63±0.71 km h -1, p<0.001). No difference was observed between the hiking pace on the easy trail or the downhill portion of the strenuous trail (p=0.80). Conversely, ratings of perceived exertion were significantly greater during the uphill portion of the strenuous trail (13.7±2.4) compared to both the easy trail (9.9±1.3, p<0.001) and the downhill portion (10.4±2.5, p<0.001). There was no difference in RPE between the easy trail or the downhill portion of the strenuous trail (p = 0.40). 427 The uphill trail elicited significantly elevated HR (p=0.04, see figure 1) and EE compared to the other hiking conditions (p=0.02, see figure 2). The downhill portion of the strenuous trail produced significantly increased SC compared to the easy trail only (p=0.01, see figure 3). No differences were observed for any other condition (p>0.05). Additionally, downhill CA was significantly greater when compared to the strenuous uphill portion (p=0.01, see figure 4), but no differences were observed for any other condition (p>0.05). No significant differences for trail type were noted for MHR (up = 168±22 beats min -1, easy = 162±22 beats min -1, down = 147±20 beats min -1 ; p=0.38), RR (up = 38±17 Breaths min -1, easy = 34±7 Breaths min -1, down = 39±14 Breaths min -1 ; p=0.45) or MRR (up = 54±17 Breaths min -1, easy = 64±25 Breaths min -1, down = 64±20 Breaths min -1 ; p=0.31). Figure 1. Average heart rate obtained using the Hexoskin shirt on different trail types. * Significantly different from easy-rated and downhill conditions, P<0.05. Significant ICC was observed for DBP (r = 0.80, p = 0.02), RR (r = 0.98, p = 0.01), SC (r = 0.97, p = 0.01), CA (r = 0.97, p = 0.01) and RPE (r = 0.94, p = 0.01). The ICC for SBP (r = 0.65, p = 0.07), HR (r = 0.73, p = 0.14), MHR (r = 0.65, p = 0.91), EE (r = 0.53, p =

0.25), and maximal RR (r = 0.68, p = 0.09) were not significant. Figure 2. Estimated energy expenditure obtained using the Hexoskin shirt on different trail types. * Significantly different from easy-rated and downhill conditions, P<0.05. Ratings of perceived exertion were not significantly correlated with SBP, average HR, or MHR during any of the hiking stages (see table 1). Furthermore, there was no significant correlation between RR and CA in any of the hiking stages (easy trail r = 0.19, p = 0.49; strenuous uphill r = 0.52, p = 0.16; strenuous downhill r = 0.25, p = 0.49). Table 1. Pearson correlations between ratings of perceived exertion and select dependent variable on differently rated trails (easy, strenuous uphill, strenuous downhill). SBP Average HR Maximal HR RPE Easy Trail r = 0.04, p= 0.86 r = 0.29, p= 0.37 r = 0.26, p= 0.41 RPE Uphill r = 0.03, r = 0.60, r = 0.70, RPE Downhill p= 0.94 r = -0.50, p= 0.14 p= 0.12 r = 0.20, p= 0.61 p= 0.051 r = 0.30, p= 0.43 DISCUSSION Figure 3. Total step count obtained using the Hexoskin wearable technology on various trails. *Significantly different from the easy-rated trail, P<0.05. Figure 4. Cadence obtained using the Hexoskin wearable technology on various trails. * Significantly different from the strenuous uphill trail, P<0.05. 428 The primary purpose of this investigation was to pilot test the HxS while obtaining physiological measurements in an outdoor trail hiking setting. We hypothesized this technology would allow us to record measures that provided face validity. While measurements of HR and EE demonstrated expected values, it was not the case for MHR, RR, or MRR. Additionally, while HxS measurements of RR, SC, and CA were found to be reliable, the measurements of HR, MHR, EE and MRR returned nonsignificant intraclass correlation coefficients. Based on the physiological responses that we reported in our previous investigation (2), we expected to observe a general increase during strenuous uphill hiking when compared with both the easy-rated trail and downhill portion of the strenuous

trail. While we did observe this phenomenon for HR and EE (see figures 1 and 2), it was not consistent for MHR, RR, or MRR. The similar response in these variables to the different trail conditions may be due to the subjects self-selecting a slower pace for the strenuous uphill hike. Evidence for this is suggested by the lower cadence for the uphill hike (Fig. 4) coupled with a significantly greater RPE. Additionally, while not significant, there was a trend for RPE obtained during the uphill strenuous portion of the hike to be correlated with maximal heart rate (p=0.051). We have also observed that the HxS occasionally returned spurious values which could account for the results obtained. This should be taken into account for investigators wishing to utilize HxS in the field. While we acknowledge that a great number of subjects are necessary to determine reliability measures for the HxS, the poor ICCs in the current investigation are a concern. This is another factor that should be taken into consideration for researchers using this technology to obtain physiological measures in an outdoor field setting. Future studies similar to work by Villar et al. (4) will be necessary to confirm that the HxS technology is valid and reliable in both laboratory and field-based settings. The results of this study indicate that HxS technology may be utilized to provide select physiological data in an applied setting. However, our results should interpreted carefully. During the course of our testing, HR did not register in 5 out of 10 subjects on the easy trail, and 8 out of 10 participants during the strenuous hike. Due 429 to the nature of field testing, we were not cognizant of this fact until we attempted to download the data at a later time. Additionally, estimated EE values for the Hexoskin appears to be linked to HR intensity. While further testing is necessary to determine the validity of this algorithm, the returned EE will not be accurate in cases where HR does not register on the HxS device. This study demonstrated there may be issues concerning the HxS s ability to measure and record data in a real-life setting. This product should first be validated against established laboratory and field standards in order to confirm the manufacturer s claims that the HxS is indeed a useful tool for physical training, sleep, and personal daily activities. In conclusion, we recommend that validity and reliability be established before HxS are utilized for research purposes in a fieldbased environment. REFERENCES 1. Borg GA. Psychophysical bases of perceived exertion. Med Sci Sports Exerc 14(5):377-381, 1982. 2. Manning JW, Montes J, Stone TM, Rietjens RW, Young JC, DeBeliso M, Navalta JW. Cardiovascular and perceived exertion responses to leisure trail hiking. J Outdoor Rec Ed Leadership. 7(2): 83-92, 2015. 3. Papi E, Osei-Kuffour D, Chen YM, McGregor AH. Use of wearable technology for performance assessment: a validation study. Medical Engineer Physics 37(7):698-704, 2015. 4. Villar R, Beltrame T, Hughson RL. Validation of the Hexoskin wearable vest during lying, sitting, standing and walking activities. Appl Physiol Nutr Metabol In Press, 2015.

5. Yang CC, Hsu YL. A review of accelerometrybased wearable motion detectors for physical activity monitoring. Sensors 10(8):7772-7788, 2010. 430