Balanced SCUBA Regulator User Guide

Similar documents
SuperFlow Scuba Regulator Assembly

User Guide For SuperFlow First Stage SCUBA Regulator Assembly (Regulator P/N )

User Guide For SuperFlow Second Stage Non-Balanced SCUBA Regulator Assemblies

Balanced SCUBA Regulator User Guide

User Guide For Switchover Open Circuit Regulator Assembly (Regulator P/N )

In this manual; Warnings, Cautions and Notes calls your attention to information provided to help ensure your safety. Always dive safely.

Balanced SCUBA Second Stage Regulator (P/N ) Maintenance Manual Contents

R0001. Northern Diver. HYDRA Regulator Manual

Balanced SCUBA Second Stage Regulator (P/N ) Contents

RG3100 and RG3100Ice Regulator System

Kirby Morgan Air Control System 5 Operations and Maintenance Manual KMDSI Part # Patented, patents pending, foreign patents apply

Appendix Breathing Gas Requirements EXO Balance Regulator Full-Face Mask

RG2200 BC Integrated Octopus

Regulator Owner's Manual

Part # Balanced SCUBA Regulator Assembly for M-48 SuperMask and MOD-1 Installation Guide

KIRBY MORGAN DEEP SEA DIVING HELMETS ALL MODELS HELMET AND EMERGENCY GAS SYSTEM DAILY SET-UP AND FUNCTIONAL CHECKLIST APPENDIX A2.

KMB 18/28 (BANDMASK) MONTHLY MASK INSPECTION APPENDIX A

RG1200 Regulator System

DRAFT 12/17/03 KMB 18/28 (BANDMASK) OVERHAUL, MAINTENANCE, AND INSPECTION CHECKLIST APPENDIX A

( SC) NOTE: KMDSI strongly recommends that all repairs be performed by trained Personnel.

KMB 18/28 (BANDMASK) OVERHAUL, MAINTENANCE, AND INSPECTION CHECKLIST APPENDIX A

REGULATOR OWNER S GUIDE

SEA LW & 4500 (Survival Egress Air) User's Manual

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

SHERWOOD PRO OWNER S MANUAL

Regulator Owner s Manual. Regulator Owner s Manual

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator

453 Series Steam Heated Vaporizing Regulator

SHERWOOD OWNER S MANUAL

Service and Repair Manual

RG1200 Service and Repair Manual

Chapter 9 Accessories

KIRBY MORGAN SUPERFLOW REGULATOR OPERATIONS AND MAINTENANCE MANUAL

High Pressure Inlet Kits for CONCOA BlendMites and BlendMasters

ADMINISTRATION GENERAL INFORMATION OCEANIC ADMINISTRATION FOR PRODUCT SERVICE PROCEDURES

FLANGED TWO-PIECE BALL VALVES

WARNING: Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.

STOP. Chapter 1 General Information KMDSI Products. 1.1 Introduction. EXO Full-Face Mask Manual

Operations & Maintenance Manual for the EXO Original and EXO Balanced Regulator Full Face Mask

FLANGED TWO-PIECE BALL VALVES

Flathead VI Owner s Manual

User Instruction Manual

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

Tri-Safem Model I1 Regulator. INSTRUCTIONS and PARTS

Freedom8 ShoeBox Compressor Manual

KIRBY MORGAN DEEP SEA DIVING HELMETS ALL MODELS OVERHAUL, MAINTENANCE, AND INSPECTION CHECKLIST APPENDIX A

Chapter 1 General Information KMDSI Products


AIR SOURCE. Owner's Manual

Chapter 1 General Information KMDSI Products

AIR INLINE METAL SHEAR

Product Information News

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures

12S 1st Stage. -Maintenance Procedure-

Contents. Stainless Steel Side Block. 1.1 Separating the Side Block. Stainless Steel Side Block Reassembly of. Assembly from the Helmet Shell

User Operation Manual and Safety Instructions

KIRBY MORGAN DEEP SEA DIVING HELMETS ALL MODELS OVERHAUL, MAINTENANCE, AND INSPECTION CHECKLIST APPENDIX A

SOTR Special Operations Tactical Respirator

Model ASSEMBLY and OPERATING INSTRUCTIONS

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

Inflatable Stand Up Paddle Board Manual

Model No Product Name Handpiece Only Complete System

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

FLANGED MULTI-PORT BALL VALVES

Helicopter Aircrew Breathing Device (H.A.B.D.) User s Manual

O2 TECH REG O24/Alpha 7 Regulator owner's guide

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.

Manifold Block (Product Part #s , , )

WARNING: Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.

AIR HAMMERS MODEL NO: CAT138/CAT139 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: / GC064

Gemini Owner s Manual

Where Depth of Experience Produces the Height of Innovation. OWNER S MANUAL BRUT SRB

AND OPERATION INSTRUCTIONS

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

ROPV R40 E Series User Manual

SPECIFICATIONS TABLE Maximum Air Pressure 115 PSI Air Tank Capacity 20 Gallons

Pressure Relief Valve Instruction Manual

MAINTENANCE PROCEDURE FOR X 650

Product Information News September 26, 2003

X-Tech CLV User Manual. English

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

Yoke Block Instruction Manual

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

Aluminum 13 cu tank Includes regulator Fill pressure: 3,000 psi (200 bar) Output: 1,100 psi +/- 10% (75bar)

Contents. REX Regulator and Oral Nasal. 1.1 Regulator Performance Kirby Morgan Tools for the REX REX Regulator

MMR Air Mask With. with Quick-Connect Hose

SERVICE MANUAL MODEL BA100BMST 100 SCFM PORTABLE AIR PANEL

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

3/8" Dr. Air Butterfly Impact Wrench

INSTRUCTIONS warranty watch care

1 DRIVE INDUSTRIAL IMPACT WRENCH

AIR/OVER HYDRAULIC JACK 20 TON

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

CSA Sample Draw Aspirator Adapter Operator s Manual

SIDE 16 Sidemount System User Manual

Part # KMB 18 Small/Medium Hood with Small Molded Face Seal Kit

M5400 Operators Manual

WEATHERIZING INSTRUCTIONS

Transcription:

Balanced SCUBA Regulator User Guide Document P/N 100-141 Kirby Morgan Dive Systems, Inc. 1430 Jason Way Santa Maria, CA 93455, USA Telephone (805) 928-7772 FAX (805) 928-0342 E-Mail: kmdsi@kirbymorgan.com Web Site: www.kirbymorgan.com Kirby Morgan, SuperLite, BandMask, Band Mask, KMB, KMB-Band Mask, DSI, Diving Systems International, EXO, REX, SuperFlow and DECA are all registered trademarks of Kirby Morgan Dive Systems, Inc. Use of these terms to describe products that are not manufactured by KMDSI is illegal. The two dimensional images (such as photographs and illustrations) of our products are copyrighted and trademarks of Kirby Morgan Dive Systems, Inc. The three dimensional forms of our products are trademark, trade design and trade dress protected. MMXIV Kirby Morgan Dive Systems, Inc. All rights reserved. This manual is made available for the express use of the owner of this Kirby Morgan product. No part of this manual may be reproduced, stored in any retrieval system, or transmitted, or used in any form or by any means, whether graphic, electronic, mechanical, photocopy, or otherwise by technology known or unknown, without the prior written permission of Kirby Morgan Dive Systems, Inc. Document #140620001

Warranty Information Warranty Information NOTE: Be sure to complete the enclosed warranty card and return it immediately, or you may register your purchase online at www.kirbymorgan.com go to Support. KMDSI warrants every new Mask, Helmet, SCUBA Regulator, Manifold Block or Kirby Morgan Air Control System 5 (KMACS 5) (each, a Product) to be free from defects in workmanship for a period of three hundred sixty five (365) days from the date of purchase from a KMDSI authorized dealer. This warranty covers all metal and plastic parts, but does NOT cover rubber parts, communications components, or head and chin cushions. In addition, due to the electrolytic nature of underwater cutting and welding, chrome plating cannot be warranted when the diver engages in these activities. Any defect of the product in workmanship or material covered by this warranty discovered within three hundred sixty five (365) days from the date of purchase must be promptly communicated in writing to the nearest authorized KMDSI dealer or (if no such dealer in the buyer s country) contact KMDSI directly at (805) 928-7772. No Product returns will be accepted by KMDSI without a returned merchandise authorization (RMA) number from KMDSI. Upon receipt of the RMA from KMDSI, the buyer should return the defective Product or part, freight prepaid, to an authorized KMDSI dealer or the KMDSI plant, as directed by the RMA. KMDSI will repair or replace the Product at no charge, within a reasonable time, as it deems necessary. 2 ⅯⅯⅩIV Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 140620001

Warranty Information This warranty is null and void if: 1) The Product is not registered with KMDSI within ten (10) days of purchase, or 2) The Product has not been properly serviced and maintained according to KMDSI factory recommended procedures described in the manual and/or Product updates have not been performed as recommended by KMDSI, or 3) Unauthorized attachments or modifications have been made to the Product, or 4) The Product has been used for purposes other than those for which it was designed, or otherwise has been abused, misused, or subjected to unusual conditions, or the Product s intended service has been exceeded. EXCEPT AS SPECIFICALLY PROVIDED HEREIN, THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES FOR MERCHANT- ABILITY OR FITNESS FOR A PARTICULAR PUR- POSE. THE PRODUCT COVERED BY THIS WAR- RANTY IS MARKETED AND SOLD BY KMDSI SOLELY FOR COMMERCIAL OR INDUSTRIAL USE AND IS NOT A CONSUMER PRODUCT IN- TENDED FOR PERSONAL, FAMILY, OR HOUSE- HOLD USE. In purchasing any Product subject to this warranty, the buyer agrees that its sole and exclusive remedy and KMD- SI s entire obligation in contract, tort, or otherwise under this contract will be repair or replacement at KMDSI s option of the Product or any parts which KMDSI determines during the applicable warranty period are defective in workmanship or material covered by this warranty. All exchanged parts are the property of KMDSI. The buyer s ⅯⅯⅩIV Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 140620001 3

Warranty Information exclusive remedy and the KMDSI s entire liability in contract, tort, or otherwise is the payment by KMDSI of the buyer s actual damages up to but not to exceed the amount paid by the buyer for the Product. In no event shall KMDSI be liable to the buyer for indirect, special, incidental or consequential damages (including, but not limited to, damages for lost profits, lost sales, loss of business opportunity, or for injury to persons or property arising out of the use of the Product). Any claim or action for breach of warranty must be commenced within one year following delivery of the Product to the buyer. Buyer acknowledges that this warranty is the sole and exclusive warranty of the Product and that it supersedes any and all oral or written representations and undertakings between KMDSI, its dealers, and the buyer relating to the Products. This warranty allocates the risks of product failure between KMDSI and the buyer, which allocation is recognized by both parties and is reflected in the price of the goods. The buyer acknowledges that it has read this agreement, understands it, and is bound by its terms. B WARNING Diving with compressed breathing gas is a hazardous activity. Even if you do everything in the proper manner there is always the potential for serious injury or death. No one piece of diving equipment can prevent the possibility that you may be injured or killed any time you enter the water. The information in this manual is intended for users of Kirby Morgan helmets and persons that maintain or service Kirby Morgan helmets. 4 ⅯⅯⅩIV Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 140620001

Table of Contents 2 Warranty Information Table of Contents 7 Definitions of Signal Words Used in this Guide 7 Product Changes 10 Cold Water Diving 11 CR Marking 11 CE Certification 14 Notified Body 14 2nd Stage Regulator Serial Number Location 14 1st Stage SCUBA Regulator and 2nd Stage Regulator Maximum Work Pressure 15 Divers Work Rate Expressed as Respiratory Minute Volume (RMV)* 15 Regulator Transport and Storage 17 References to EN250 - Object, Definitions, Limits 17 SCUBA-Minimum equipment (EN 250): 17 Definitions (EN 250) 18 Kirby Morgan Balanced SCUBA Regulator Assembly 19 General Precautions and Warnings 20 Preparation and Setup ⅯⅯⅩIV Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 140620001 5

Table of Contents 20 Mounting the First Stage Onto the Cylinder Valve (Yoke Connector) 21 Using the balanced second stage regulator with the Kirby Morgan M-48 SuperMask and M-48 Mod-1 23 Pre-Dive Checkout 24 Inspection Checklist 25 During the Dive 26 After the Dive 26 Removal of the Regulator Assembly from the Cylinder Valve 27 Safety Precautions 27 Specifications 28 Routine Maintenance 28 Daily Pre-Dive Maintenance 28 Post Dive Maintenance 30 Scheduled Maintenance 31 SuperFlow First Stage Regulator P/N 305-161 32 Balanced SCUBA Regulator Assembly 34 Maintenance Record 6 ⅯⅯⅩIV Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 140620001

Definitions of Signal Words Used in this Guide Definitions of Signal Words Used in this Guide B CAUTION This word indicates a potentially hazardous situation, which if not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices. B WARNING This word indicates a potentially hazardous situation, which, if not avoided, could result in death or serious injury. REMARKS: Operating or descriptive information which will help you make the best use of your regulator. This user guide contains important safety information and should always be available to those personnel using this equipment. Read, understand, and retain all instructions before using this equipment to prevent injury or equipment damage. If you sell or loan this equipment to another person, be sure that this manual accompanies the gear when you transfer possession to them. Product Changes Following publication of this booklet, certain changes in standard equipment, options, prices and the like may have occurred which would not be included in these pages. Your Authorized KMDSI dealer is your best source for up-to-date information on any of these products. Kirby Morgan Dive Systems Inc. reserves the right to change product specifications at any time without incurring obligations. In order to use this regulator assembly, it is essential to complete a training course and receive certification, issued by a recognized national SCUBA training organization, confirming your ability to dive. ⅯⅯⅩIV Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 140620001 7

Product Changes B CAUTION By using this equipment the diver acknowledges that he has read and completely understands the instruction manual provided with it, and hereby agrees to hold harmless Kirby Morgan Dive Systems, inc. from any accident, malfunction, or other event arising from the misuse of the equipment, or from any lack of, or incomplete understanding of its operation and function. B CAUTION This regulator assembly should be used only with breathing air meeting requirements of the EN12021 B CAUTION When the regulator is used in a European Union member country, it should be used only with equipment and accessories that are CE approved, according to EN250. B WARNING The first stage SCUBA regulator has not been designed or tested for use with breathing gas mixtures containing greater than 23% oxygen. Do not use the first stage or the regulator assembly with second stage with breathing gases containing more than 23% oxygen. Use with gas mixtures containing in excess of 40% oxygen could lead to fires or explosions. 8 ⅯⅯⅩIV Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 140620001

Product Changes B WARNING The second stage SCUBA regulator has not been designed or tested for use with breathing gas mixtures containing greater than 50% oxygen. Do not use the second stage with breathing gases containing more than 50% oxygen. Use with gas mixtures containing in excess of 50% oxygen could lead to fires or explosions. B WARNING In accordance with the EN250 Standard, the maximum approved depth for the use of this equipment is 50 meters (164 FSW) @ 62.5 RMV (heavy work load). Do not exceed this limit. The use of open circuit SCUBA at depths below 164 FSW poses extreme risks including out-of-air emergencies and decompression sickness, which can lead to serious personal injury or death. B WARNING Never use solvents or aerosol sprays on our around the regulator assembly. Certain solvents and propulsion agents attack and damage rubber and certain plastics. This could lead to regulator failure. Drowning could result. This user guide gives basic daily operational information for the Kirby Morgan Balanced SCUBA Regulator assembly. Before each use the regulator assembly should be carefully checked and submitted to the operational tests. Never dive with a regulator showing any signs of deterioration or a below normal performance. The hoses fitted to the regulator assembly, and supplied by ⅯⅯⅩIV Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 140620001 9

Cold Water Diving KMDSI meet the requirements of the EN250 standard concerning the connection of components. Only original Kirby Morgan hoses should be used as replacements. - HP thread 7/16" - 20 UNF - MP thread 3/8" - 24 UNF B CAUTION Always allow pressure to build up slowly in the regulator by turning on the cylinder valve slowly. Use only Christo-Lube on the rubber components. Never grease the parts of your regulator with a lubricant containing hydrocarbons, household oil, or motor oil. Cold Water Diving Before diving in cold water (water temperature below 10 C/50 F), the diver should be trained and have mastered the techniques of cold water diving, learning techniques and all precautions necessary to avoid freezing of the regulator. All of this is included in the training programs of organizations offering courses in diving in cold water or under ice. You should also use equipment intended for this purpose. This regulator is not CE approved for waters colder than 10 C /50 degrees F. In order to reduce the risks of regulator freezing when diving in cold water (below 10 C), consider doing the following: 1. Protect your regulators from any water entering the first or second stages. 2. Protect your equipment from cold before the dive. Keep your regulator and all its accessories in a warm dry place. 3. Carry out all pre-dive checks of your equipment in a warm dry place if necessary, before even going to the dive site. 4. Avoid breathing through the regulator or pressing the purge button in very cold air before entering the water. 5. Check that the air used to fill your cylinder is dry. The water vapor contained in this air should have a condensation point 10 ⅯⅯⅩIV Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 140620001

- Cr Marking below -54 C. Excess water vapor can freeze, causing a free flow, or blocking the air flow completely. CR Marking The 1st Stage SCUBA Regulator and 2nd Stage Regulator meets or exceeds all standards established by Dive Lab of Panama City, Florida, and is CR (Commercially Rated) marked. COMMERCIALLY RATED - PROFESSIONAL DIVING GEAR - DIVELAB TESTED TM TM CE Certification The balanced SCUBA regulator (P/N 200-120) has been tested and conforms to the performance requirements as set forth in Annex II of Directive 89/686/EEC and, as far as applicable, the EN 250:2000 and EN 250/A1:2006. The Kirby Morgan first stage P/N and Balanced SCUBA Regulator 2nd Stage Regulator P/N 200-120 as assembly P/N 200-150 are fully CE marked. Category of PPE: III B WARNING The 1st Stage SCUBA Regulator and 2nd Stage Regulator have been tested with air and CE certificates for use with air up to 50 meters. Compressed air must be compliant with the EN 12021. All the tables reporting the technical data and the pressure of use are relative to compressed air. ⅯⅯⅩIV Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 140620001 11

CE Certification CE Mark On the top of the knob is a sticker with the following information (as shown above): 1. The name and the address of the manufacturer 2. CE marking: 0477 3. Notifying Body Number 4. EN 250 :2000/A1:2006 The Working Pressure is reported on the 1st Stage FRAME. 12 ⅯⅯⅩIV Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 140620001

CE Certification On the bottom part of the 1st Stage the Working Pressure is reported in PSI and Bar. The serial number is printed on the frame. On the frame of the Balanced SCUBA Regulator 2nd Stage regulator the CE mark is affixed. BALANCED SCUBA REGULATOR EN 250:2000, EN 250/A1:2006 >10 C 0477 KIRBY MORGAN DIVE SYSTEMS, INC. 1430 Jason Way, Santa Maria, CA 93455 Sample of marking on Balanced SCUBA Regulator 2nd stage housing B CAUTION The user cannot: Remove the mark from the frame/label of the Balanced SCUBA Regulator. Modify or counterfeit the data reported on the frame/label. B CAUTION The data shall be visible and legible throughout the life of the Balanced SCUBA Regulator. If the data deteriorates or is not legible the user shall contact the manufacturer. ⅯⅯⅩIV Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 140620001 13

Notified Body Notified Body The Notifying Body is Eurofins-Modulo Uno S.p.A. Address: Via Courgnè, 21 10156 - Torino - ITALY Identification number: 0477 2nd Stage Regulator Serial Number Location The serial number is printed on the top part, near the mouth piece, on the 2nd stage regulator. 1st Stage SCUBA Regulator and 2nd Stage Regulator Maximum Work Pressure Regulators PSI BAR 1st Stage 145 9.99 2nd Stage 150 10.34 14 ⅯⅯⅩIV Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 140620001

Divers Work Rate Expressed as Respiratory Minute Volume (RMV) Divers Work Rate Expressed as Respiratory Minute Volume (RMV)* Work Load RMV Cubic Feet/Minute (CFM) Rest 7-10 RMV 0.2-0.35 CFM Equivalent Land Based Exercise Light Work 10-20 RMV 0.35-0.7 CFM Walking 2 miles per hour Moderate Work 20-37 RMV 0.7-1.3 CFM Walking 4 miles per hour Heavy Work 37-54 RMV 1.3-1.9 CFM Running 8 miles per hour Severe Work 55-100 RMV 1.94-3.5 CFM * source: U.S. Navy Diving Manual Regulator Transport and Storage 1st Stage: The kind of package is a plastic bag that is sealed; The weight of the bag is usually 2 pounds (.9 Kg); The package dimension is 6 12 inches (152.4 304.8 mm); One regulator is packed per bag; The regulators are sent to dealers by airfreight or truck. Depending on how the dealer wants it sent. 2nd Stage: The kind of package is a plastic bag that is sealed; The weight of the bag is usually.75 pounds (.35 Kg); The package dimension is 8 10 inches (203.2 254 mm); One regulator and hose protector is packed per bag; The regulators are sent to dealers by airfreight or truck. Depending on how the dealer wants it sent. 1st and 2nd Stage Regulators when purchased together: The kind of package is a cardboard box with cardboard inserts to stabilize the regulators; ⅯⅯⅩIV Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 140620001 15

Regulator Transport and Storage The weight of the box is usually 3.7 pound (1.67 Kg); The package dimension is 13 9 1/2 4 1/4 inches (330.2 241.3 107.95 mm); One 1st Stage and one 2nd Stage regulator is packed per box; The regulators are sent to dealers by airfreight or truck. Depending on how the dealer wants it sent. Packaging Step 1 Packaging Step 2 Packaging Step 3 Packaging Step 4 Packaging Step 5 16 ⅯⅯⅩIV Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 140620001

References to EN250 - Object, Definitions, Limits References to EN250 - Object, Definitions, Limits OBJECT: The requirements and tests provided for in EN 250 are aimed at providing a minimum safety level for the operation of diving breathing apparatuses at a maximum depth of 50 m / 164 feet. SCUBA : Definition (EN 1 32): Self-contained, open-circuit compressed air underwater breathing apparatus is an apparatus which has a portable supply of compressed air carried by the diver, allowing him to breathe underwater. SCUBA-Minimum equipment (EN 250): a) Air cylinder/ cylinders b) Demand regulator c) Safety device, e.g. pressure gauge / computer or reserve or alarm. d) Carrying frame or holding device for air cylinder(s) to mount the harness or carrying system, e.g. backpack and/or straps. e) Face piece: mouth piece assembly or full face mask or diving helmet. f) Operating instructions. SCUBA - Component Units (EN 250): The Kirby Morgan Super- Flow SCUBA Regulator Assembly described in this guide may be combined with other SCUBA components such as cylinders and pressure gauges certified in compliance with EC directive 89/686 and EN 250. The air contained in the cylinders must comply with the requirements for breathable air set forth in EN 1 32 - Appendix A. Definitions (EN 250) COLD WATER DIVING - water temperature below +10 C (50 f) WARM WATER DIVING - water temperature over +10 C (50 f) MAXIMUM DEPTH: 50 m / 164 feet. STORAGE TEMPERATURES: +70 c / -30 c (max/min) ⅯⅯⅩIV Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 140620001 17

Kirby Morgan Balanced Scuba Regulator Assembly Kirby Morgan Balanced SCUBA Regulator Assembly Thank you for choosing a Kirby Morgan regulator. Your new regulator assembly has been designed and manufactured with pride, according to Kirby Morgan's world renowned exacting standards for quality and performance. The Kirby Morgan Balanced SCUBA Regulator is a high performance regulator which was designed for the professional SCUBA diver. The second stage is a modified version of the same regulator used on the Kirby Morgan 97 helmet and stand alone SuperFlow 455 regulator. Many of the parts used in this SuperFlow are identical to those used on the KM 97 helmet and SuperFlow 455 regulator. This is helpful to dealers in stocking parts for service and repair. The first stage used on the SuperFlow regulator is known as our HiVent first stage. This regulator was developed from the technology used in our Kirby Morgan Air Control Systems. It offers an exceptionally high flow of air with a minimum pressure drop. Provided it has been purchased new from an Authorized KMDSI Dealer, your regulator assembly is covered by KMDSI's Limited Warranty. Be sure to read and fill out the warranty card completely and return the bottom portion within ten (10) days of purchase. Also save your sales receipt. A copy of your receipt must be presented whenever obtaining warranty service. Perhaps more than any other piece of diving equipment, your regulator's function and performance relies greatly on the care and maintenance it will receive, in addition to regularly scheduled dealer service. Before you dive with your new Kirby Morgan regulator, it is important to read this guide in its entirety; to become 18 ⅯⅯⅩIV Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 140620001

General Precautions and Warnings familiar with its features, as well as the correct procedures for setup, pre-dive inspection, and post-dive maintenance. General Precautions and Warnings Before using this regulator assembly, you must have successfully received training and certification in the technique of SCUBA diving from a recognized certification agency (or any Military or government operated diving school). Use of this equipment by a person who is not certified by a recognized agency shall render all warranties, express or implied, null and void. Use of SCUBA equipment by uncertified, or untrained persons, is dangerous and can result in serious injury or death. B WARNING Never lubricate any part of the regulator or cylinder valve with any lubricant. Lubrication must only be performed by a KMDSI factory trained technician. Improper lubrication can lead to regulator malfunction. Drowning can result. B CAUTION Do not use the regulator first stage as a carrying handle when lifting or transporting the cylinder. Always lift the cylinder by the cylinder valve handle without the regulator attached. The regulator can be damaged if you use it to lift the cylinder. B CAUTION Factory prescribed service for this regulator assembly must be performed at least once each year by a factory trained technician who is employed by an Authorized KMDSI Dealer. Repair, service, disassembly, or first stage adjustment must not be attempted by persons who are not factory trained and authorized by KMDSI. ⅯⅯⅩIV Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 140620001 19

Preparation and Setup B CAUTION Do not leave a cylinder standing unsecured with the regulator attached to the valve. Doing so may cause permanent damage to the regulator and cylinder valve if the cylinder falls over against the first stage. Preparation and Setup KMDSI recommends that you bring your regulator assembly to your Authorized KMDSI Dealer for the installation of any accessory items, including instrumentation, LP quick disconnect hoses, and alternate air sources. Your dealer can also answer any questions you may have pertaining to the information in this guide. 1. If the adjustment knob has been turned "out" (counter-clockwise), turn it "in" (clockwise) until a clicking noise can be heard. This indicates full spring pressure has been acheived. 2. If you are using a standard cylinder with a yoke connector valve, inspect the cylinder valve O-ring for any wear or damage. Mounting the First Stage Onto the Cylinder Valve (Yoke Connector) 1. Partially unscrew the yoke screw of the first stage regulator so that the dust cap can be removed from the filter and air inlet. 2. With the cylinder valve facing away from you, release a small amount of air from the cylinder. When air is heard exiting, immediately close the valve. This will clear any moisture or debris that may be inside the cylinder valve outlet opening. 3. Place the first stage regulator over the cylinder valve so that the inlet fitting aligns with the O-ring of the cylinder valve, and the LP hose of the primary second-stage will be routed over the right shoulder. While holding the first stage in place, turn the yoke screw clockwise. Ensure that the yoke screw mates into the small dimple on the backside of the cylinder valve, and tighten finger tight only. 4. If a submersible pressure gauge is attached to the first stage, 20 ⅯⅯⅩIV Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 140620001

Using the balanced second stage regulator with the Kirby Morgan M-48 SuperMask and M-48 Mod-1 ensure that the gauge is facing away from you. Pressurize the regulator by slowly turning the cylinder valve handwheel counter-clockwise. Continue turning the cylinder valve hand wheel counter-clockwise until it is fully open, and then turn back clockwise ¼ - ½ turn. 5. Listen near the first stage to check for any leakage. If leakage is detected, immerse the first stage and cylinder valve while pressurized to determine the source. 6. If leakage has been detected, follow the procedure for removing the regulator from the cylinder valve. If air was leaking between the first stage and cylinder valve, replace or reseat the cylinder valve O-ring as needed and repeat the above procedure. If leakage persists, do not dive with the regulator! Return the regulator to a KMDSI Dealer. Using the balanced second stage regulator with the Kirby Morgan M-48 SuperMask and M-48 Mod-1 This regulator was specifically designed to work with both the M -48 SuperMask and M-48 Mod-1 as well as being a stand-alone SCUBA regulator. If you purchased Part # 200-125, it will include all necessary parts to allow using with a SuperMask, or Mod-1 mask SCUBA Pod. If you purchased part # 200-120, you should consider purchasing three additional components to optimize the intended enhancements of this design: 220-057, sleeve, 220-087 Purge Tube, and 520-038 tie wrap. These components will be used to replace the original Tilt to Purge valve that is included with all of these mask series. Using the new parts will eliminate the need to manually purge any accumulated water from inside the pod. This will now become an automatic function. 1. After removing the regulator from the pod, clean and carefully inspect the pod assembly for damages such as cuts in the rubber, cracked or broken parts. Replace as necessary. Remove the tie wrap from around the tilt to purge valve and remove the plastic tilt valve assembly, as well as the small internal valve body insert and its exhaust valve. Inspect the valve and valve body for damages, Clean and reassemble or replace as necessary. ⅯⅯⅩIV Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 140620001 21

Using the balanced second stage regulator with the Kirby Morgan M-48 SuperMask and M-48 Mod-1 2. Re-install ONLY the valve body insert with its valve, back into the tube on the pod. Push in all the way. YOU WILL NO LONGER NEED THE TILT TO PURGE VALVE ASSEMBLY. 3. Insert the 220-057 into the 220-087 purge tube, as shown. Make sure the direction of insert is correct. Make certain this part is pushed in all the way. 4. Insert these two parts together into the tube of the pod until they are against the exhaust valve and body. The outside of the tube should not be bulged out or displaced if the tube has been installed properly. Align the tube to point upwards. 5. Install the balanced regulator into the pod as per the mask manual, mouthpiece first. Align the Saddle on the exhaust 22 ⅯⅯⅩIV Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 140620001

Pre-Dive Checkout cover, over the area where the valve assembly was just installed. You will see the grooves on the tube will align to the saddle. Make sure the tube is still lined straight up and install the tie wrap 520-038. The open end of the tube should line up properly with the face of the regulator cover. This system not only provides a much easier method to de-water the pod, but it also gives the regulator a much more solid base to the mask. Any movement of the L.P. Hose will have little to no effect on the position of the regulator and mouthpiece. It also provides a HINGE point for the regulator that allows simply pushing in on the upper area of the regulator to move the mouthpiece directly into the diver's mouth. The ends of the exhaust deflectors also provide stability to this mounting system. Once the regulator has been properly mounted with these parts, it is easy to see how well stabilized the regulator is, by simply trying to move it. This should completely eliminate any jaw fatigue. Pre-Dive Checkout Before each use, the regulator assembly must be given a thorough visual inspection and functional test. NEVER dive with a regulator that shows signs of damage, or provides substandard performance until it has received complete inspection and service from an Authorized KMDSI. ⅯⅯⅩIV Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 140620001 23

Inspection Checklist Inspection Checklist 1. Remove the dust cap and closely inspect the condition of the first stage filter. It should appear clean and free of any corrosion or discoloration. If a green residue is visible on the surface of the filter, moisture has entered the first stage and may have caused corrosion to begin forming inside which can seriously impair the regulator's performance. Other colored residue may indicate that the regulator has been used with an internally corroded aluminum (white/ gray powder) or steel (rust) cylinder. In this event, the cylinder in question should be returned to the dive store for internal visual inspection. B WARNING If discoloration or contaminant residue is found to be present on the surface of the first stage filter, do not dive with the regulator until it has received factory prescribed service from an Authorized KMDSI Dealer. The presence of contaminants could cause the regulator to malfunction, leading to serious personal injury or death. 2. Prior to each use, the regulator assembly must be given a thorough visual inspection and functional test. Carefully inspect all hoses at their fittings to ensure they are securely connected into their respective ports on the first stage. If hose protectors are present, slide the protectors back to expose the hose fittings, and inspect the fittings. Inspect the length of each hose to ensure that the hoses are not blistered, cut, or otherwise damaged. 3. Visually inspect both the first and second stage regulators for any signs of external damage. 4. Slowly back out on the demand regulator adjustment knob counter clockwise until a slight free flow develops, then slowly rotate the adjustment knob in (counterclockwise) until the free flow stops. Depress the front cover of the regulator while slightly blocking the mouthpiece to prevent freeflow of the regulator. At this point the regulator is set for the least amount 24 ⅯⅯⅩIV Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 140620001

During the Dive of breathing effort. Test breathe by taking several shallow and deep breaths to ensure the regulator breathes properly. Turn the adjustment knob in (clockwise) at least three turns. This will prevent the regulator from free flowing if you enter the water without the regulator in your mouth. Readjust the regulator when in the water. During the Dive 1. This demand regulator can be adjusted by the diver during the dive by simply rotating the spring bias adjustment OUT (counter clockwise) to make the demand valve more sensitive or IN (clockwise) to make the demand valve less sensitive. In normal operation the demand adjustment should be set at the easiest breathing setting by rotating the adjustment knob OUT (counterclockwise) until a slight free flow develops and then rotate it in until the free flow stops. At this point the diver will be taking full advantage of the demand valve s performance. NOTE: Before entering the water, it is best to turn the adjustment knob in (clockwise) at least 3 full turns or until an audible click is heard. Doing this, as well as slightly covering the mouthpiece, should eliminate the possibility of free flow from sudden water force on the diaphragm. This regulator does NOT have a Pre-Dive/Dive mechanism/ vane. If the regulator does free flow, slight blockage of the mouthpiece opening will stop any flow. B WARNING The Balanced Scuba Regulator can not be used by more than one diver at a time. B WARNING Diving an adjustable demand regulator that is adjusted to breathe with heavy resistance could cause the diver to become exhausted. This could lead to drowning. Always adjust the demand regulator for the easiest breathing. ⅯⅯⅩIV Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 140620001 25

After the Dive After the Dive If fresh water is available, rinse your regulator completely while it is still connected to the tank before depressurizing it. This helps to prevent any contaminants from entering sealing surfaces inside the regulator. If this is not possible, follow the procedure for removing the regulator assembly from the cylinder valve per "Removal of the Regulator Assembly from the Cylinder Valve" on page 26 and then rinse. Store dry, properly post-dived regulators in a cool, dry place away from direct light. It is recommended that the temperature not exceed: 90 F (32 C) and not go below +14 F (-10 C) in storage. Removal of the Regulator Assembly from the Cylinder Valve 1. Shut off the cylinder air supply by turning the cylinder valve hand wheel clockwise until it stops. 2. While observing the submersible pressure gauge, depress the purge button of the second-stage. When the gauge reads zero and airflow can no longer be heard from the second stage, release the purge button. 3. Turn the yoke screw counter-clockwise to loosen it and remove the first stage from the cylinder valve. 4. Dry the dust cap with a towel or other lint-free cloth. While you may use air from your tank valve to blow the water off the dust cap, you run the risk of blowing out the dust cap O-ring and losing it. 5. Place the dust cap over the first stage inlet fitting and seal it securely in place by tightening down the yoke screw. Do not overtighten the cap. 26 ⅯⅯⅩIV Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 140620001

Safety Precautions B WARNING Use only genuine Kirby Morgan replacement parts. Safety Precautions B WARNING Unlike many of the other Kirby Morgan products, the First Stage should not be used with oxygen-enriched gas mixtures greater than 23% oxygen. NOTE: The second stage regulator can be used with 50% oxygen, provided it's kept clean. To ensure the best possible regulator performance and to avoid damage to regulator components, use only KMDSI original factory replacement parts. To avoid damage to regulator components, only the correct size and type of tools should be used. The use of adjustable wrenches should be avoided whenever possible to avoid damage to soft brass parts. Should you encounter technical difficulties in servicing a Kirby Morgan regulator, please contact Kirby Morgan or Dive Lab directly for assistance. Specifications First Stage Type: Balance Piston Maximum Supply Pressure: 3500 PSIG Intermediate Pressure: 135-145 Intermediate adjustment: Shim Low Pressure Ports: 5 High Pressure Ports: 2 Body Material: Chrome plated brass Second Stage Type: Downstream, balanced bias adjustable. Second Stage Body: Glass fiber reinforced thermoplastic Work of Breathing: 0.87/0.90 (AU) joules/liter at 62.5 RMV at 132 FSW ⅯⅯⅩIV Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 140620001 27

Routine Maintenance Work of Breathing: 1.0/1.1 (AU) joules/liter at 62.5 RMV at 165 FSW Routine Maintenance Routine maintenance is the best way to ensure long regulator assembly life and optimum performance. All end users should be instructed in the proper procedures for regulator care. Daily Pre-Dive Maintenance 1. Check the maintenance log to insure the regulator has been overhauled during the past 12 months. 2. Visually inspect the first and second stage to insure all ports are plugged and the regulator shroud/exhaust cover is secure. 3. Visually inspect all hoses for signs of damage such as cracking, fitting slippage, cuts or abrasions. 4. Visually inspect all regulator components including submersible pressure gage, inflator hose and other components. 5. Visually inspect the first stage filter in the yoke for signs of dirt and corrosion. 6. Rotate the adjustment knob in clockwise, then attach the regulator to a fully charged SCUBA cylinder and slowly open the cylinder valve. 7. Check for proper demand function and purge operation. Listen for the sounds of air leaks. Perform accessory checks as necessary for the equipment in use. Post Dive Maintenance 1. Secure the cylinder valve, depressurize the regulator assembly and remove it from the cylinder. 2. Whenever the Regulator is removed from the SCUBA Cylinder, the Dust Cap (1) should be dried and installed over the First Stage Inlet Port (5). It is very important to dry the Dust Cap (1) to prevent water from the cap from entering the First Stage. Screw the regulator set screw down until snug and the rubber dust cap is slightly compressed. 28 ⅯⅯⅩIV Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 140620001

Post Dive Maintenance 3. At a minimum, the entire regulator should be thoroughly rinsed with fresh clean water after every dive. Mild hand washing type dish soap can be used to remove grime. B CAUTION During rinsing, do not depress the Purge Button on the Second Stage. Pressing the Purge Button can allow water to enter the Inlet Valve and balance chamber. 4. If possible, the entire regulator should be soaked in fresh warm water, between 70-120 ºF, for 15 minutes or longer. Soaking in warm water will remove salt and mineral deposits more effectively than a fresh water rinse alone. B CAUTION During soaking do not depress the Purge Button on the Second Stage. 5. Allow the regulator to dry completely before storage. Remove the exhaust cover, diaphragm retaining ring and diaphragm, and allow to dry then reassemble the regulator. Do not leave the regulator sitting in direct sunlight. Shake the second stage to help remove water trapped inside. Clean, oil-free, low-pressure (< 30 psig) (1.8 bar) air can be directed into the first stage sensing holes to help displace water. This is helpful if the regulator is to be packed for travel. 6. Screw the second stage regulator adjustment knob all the way out, away from the second stage body. This will lengthen the life of the regulator seat considerably. 7. Insure the regulator is completely dry before storing. Store only in a clean, cool, dry place, away from direct light. B CAUTION Never store the Regulator while still connected to a SCUBA tank. ⅯⅯⅩIV Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 140620001 29

Scheduled Maintenance B WARNING DO NOT carry a SCUBA Cylinder by the Regulator or Hose. This abuse will lead to damage of the Regulator or Hose failure. Hose failure can result in personal injury. B WARNING DO NOT use cleaning solvents on any parts or components of this Regulator. The use of solvents may lead to failure of the Regulator parts. B WARNING NEVER pressurize the First Stage Regulator without having a Second Stage attached. Scheduled Maintenance Do not assume that a Regulator is in good working order because of infrequent use. Prolonged or improper storage can result in O- ring deterioration or internal corrosion that may result in poor performance. 1. The minimum maintenance suggested for all regulators is an annual inspection / soft goods overhaul by a qualified KMDSI technician. However, regulators that are used more than 20 times a month or under severely harsh environmental conditions should be serviced more often. For example, a regulator used as a rental or for training purposes may require service every two to three months or more. Whenever a regulator has been inactive for longer than three months, it should be carefully inspected and surface function checked prior to use. 2. The first stage sintered filter (3), located in the yoke assembly (5), should be visually inspected on a regular basis. If a visual inspection reveals discoloration or obvious signs of dirt or corrosion, the regulator should be thoroughly serviced. In addition, the SCUBA cylinders used must be internally inspected and cleaned if necessary. 30 ⅯⅯⅩIV Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 140620001

SuperFlow First Stage Regulator P/N 305-161 SuperFlow First Stage Regulator P/N 305-161 1 Location # Part # Description 1 410-025 Protector Cap 2 430-060 Retainer Ring 3 355-035 Filter 4 510-013 O-ring 5 350-131 Yoke Retainer 6 510-011 O-ring 7 310-115 O-ring 8 350-060 Plug, L.P. High Flow, w/o-ring 9 510-013 O-ring 10 350-135 Regulator Body 11 330-050 Knob 12 350-110 Yoke 13 320-085 Saddle 14 550-095 Plug L.P. 15 310-003 O-ring 16 510-012 O-ring 17 350-092 Plug H.P. 18 510-012 O-ring 19 350-120 Seat 20 350-105 Poppet 21 350-137 Packing Disk, Small 22 310-023 O-ring 23 510-010 O-ring 24 410-010 O-ring 25 350-133 Packing Disk, Large 26 335-010 Spring 27 350-215 Shim (May or may not be present. For adjustment purposes) 28 350-086 Piston 29 310-022 O-ring 30 510-008 O-ring 31 330-510 Washer 32 330-320 Lock Nut 33 250-020 1st Stage Regulator Cap 5 2 3 4 6 7 SuperFlow First Stage Regulator P/N 305-161 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 ⅯⅯⅩIV Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 140620001 31

Balanced Scuba Regulator Assembly Balanced SCUBA Regulator Assembly Balanced SCUBA Regulator Assembly P/N 200-120 Location # Part # Description 1 310-278 Mouthpiece 2 520-038 Tie Wrap 3 220-086 Flow Baffle 4 220-041 Regulator Housing 5 250-031 Adjustable Nipple 6 510-010 O-ring 7 510-015 O-ring 8 220-056 Lever Bearing Clip 25 9 250-059 Main Tube 10 220-090 Flow Sleeve 11 210-060 Valve Seat 12 220-050SS Inlet Valve 13 205-020 Inlet Valve Assembly 14 235-015 Spring 15 210-055 O-ring, Balanced 13 12 1 16 250-029 Piston, Balanced 10 11 8 9 1 2 7 3 6 4 5 28 29 30 42 31 43 32 37 38 39 41 36 40 * When using with an M-48 mask, location numbers 35 and 36 must be purchased in addition to P/N 200-120 assembly. 35 32 ⅯⅯⅩIV Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 140620001

Balanced Scuba Regulator Assembly 26 27 24 21 22 23 25 18 19 20 17 13 14 15 16 Location # Part # Description 12 11 Location # Part # Description 17 510-017 O-ring 18 250-012 Adjustment Guide Insert 19 220-079 Spring Seat 20 210-056 O-ring 21 250-013 Adjustment Shaft 28 22 220-080 Spacer 23 220-031 Thrust Washer 24 220-021 End Cap Packing Nut 25 205-030 Main Tube Assembly 26 220-085 Adjustment Knob 27 230-017 Adjustment Knob Screw 2 33 28 240-008 Lever Arm 29 240-009 Packing Lock Clip 30 210-041 Diaphragm 31 220-032 Diaphragm Washer 34 32 220-034 Diaphragm Surge Dam 33 220-033 Diaphragm Retainer Ring 34 220-042 Regulator Shroud/Exhaust Cover 35 *220-087 Purge Tube, Balanced 36 *220-057 Purge Sleeve, Balanced 37 510-019 O-ring 38 520-022 Exhaust Valve Insert 39 510-776 Exhaust Valve 40 540-012 Retaining Ring 41 205-025 Regulator Body Assembly 42 250-058 Jam Nut 43 220-088 Hose Protector ⅯⅯⅩIV Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 140620001 33

Maintenance Record Maintenance Record Date Dealer Name Technician 34 ⅯⅯⅩIV Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 140620001

This page intentionally left blank

Kirby Morgan Dive Systems, Inc. 1430 Jason Way Santa Maria, CA 93455, USA Telephone (805) 928-7772 FAX (805) 928-0342 E-Mail: kmdsi@kirbymorgan.com Web Site: www.kirbymorgan.com.com