WBEA Standard Operating Procedure

Similar documents
Title: Standard Operating Procedure for Elemental and Organic Carbon (EC and OC) using Non-Dispersive Infrared Detection (NDIR)

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD)

Standard Operating Procedure for H 2 S and SO 2 Converter

Title: Standard Operating Procedure for R&R Environmental Devices Model MFC201 Gas Dilution Calibrator

Title: Standard Operating Procedure for Dasibi Model 5008 Gas Dilution Calibrator

Title: Standard Operating Procedure for Sabio 2010 and 4010 Dilution Calibrator

COMPARISON OF DIFFERENTIAL PRESSURE SENSING TECHNOLOGIES IN HOSPITAL ISOLATION ROOMS AND OTHER CRITICAL ENVIRONMENT APPLICATIONS

Title: Standard Operating Procedure for The Tapered Element Oscillating Microbalance (TEOM)

TECHNICAL NOTE. October 23, Procedures for Verifying Temperature Calibration

The vital hand-held held tool that replaces an entire belt weather kit.

THE FUNDAMENTALS OF THE AIR SAMPLER CALIBRATION-VERIFICATION PROCESS

210 Series Transmitter with External Electrochemical Sensor

HLM-2000-TX Gas Transmitter User Manual

DEVICES FOR FIELD DETERMINATION OF WATER VAPOR IN NATURAL GAS Betsy Murphy MNM Enterprises 801 N. Riverside Drive Fort Worth, Texas 76111

STANDARD OPERATING PROCEDURES. Andersen Instruments Federal Reference Method (FRM) Ambient Particulate (PM 10 /PM 2.

IEP SENSOR BRACKET CHECKOUT AND VERIFICATION. This is a non-hazardous test.

MODEL GT820 OXYGEN SENSOR

Best Practice Guide, Servomex 2700

Technical Data Sheet MF010-O-LC

General Accreditation Guidance. User checks and maintenance of laboratory balances

Vaisala Pressure, RH & Temp. Transmitter. The instrument was operational upon receipt. The instrument was adjusted and calibrated.

USING THE CS400/CS405 (KPSI SERIES 169/173) SUBMERSIBLE PRESSURE TRANSDUCER WITH CAMPBELL SCIENTIFIC DATALOGGERS INSTRUCTION MANUAL

HumiSys HF High Flow RH Generator

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Improve Process Reliability

Environmental Protection Division

Application Note AN-107

DTG - LCD Digital Temperature Gauge USER MANUAL

! Warning, refer to accompanying documents.

HLM-2000-TX Gas Transmitter User Manual

PRODUCT CONFORMITY CERTIFICATE

Technical Procedure for General Laboratory Equipment

Siting classification for Surface. Michel Leroy, Météo-France

EASIDEW TRANSMITTER with Current Source Output

Transmitter CS 21 Operation Manual

Mass Flowmeters. Mass Flowmeters for Gases

EC214 EC215 - EC215R Bench Conductivity Meters

Met One E-BAM Particulate Monitor

Transmitter CS 21 Operation Manual

AMS 6916 Board mount pressure sensor with ratiometric analog output

PRESSURE SENSOR - ABSOLUTE (0 TO 700 kpa)

TEL/jlRE" Introduction. Display Features and Modes. Startup Procedure. Power-Up Procedure. Adjustment Modes

Air Monitoring Directive Chapter 7: Calibration

MIL-STD-883G METHOD

BAPI Pressure Line of Products - FAQs

AMS 2710 PCB pressure sensor module with V output

4.0 Audit Procedure for the MetOne SASS Speciation Sampler

Columbus Instruments

A Journal of Practical and Useful Vacuum Technology. By Phil Danielson

Model DPC3500 Continuous Low Range Dew Point Analyzer. Operations Manual

Technical Information Conducal CLY421

GMC-I Service GmbH Calibration Center

OxiQuant S. Operating Instructions

Best Practice for Calibrating LTH Conductivity Instruments

Pool and Spa. Water Testing

Advanced Test Equipment Rentals ATEC (2832)

Vortex Flow Meter Wafer or Flange Connection. - Steam - Liquid - Gas

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

Thermo Scientific Model 146i Principle of Operation

Certification of AMS acc. EN 15267, Part 3 - Overview and First Experience -

Predicted Dispense Volume vs. Gravimetric Measurement for the MICROLAB 600. November 2010

HYGRODYNAMICS NARROW RANGE HYGROSENSOR CONTENTS

ali-q TM Gravimetric Verification Procedure

Optical Dissolved Oxygen Meter

HI 2314 HI 2315 HI 23151

Thermo Environmental 48C Carbon Monoxide QA Plan Section I Electronic Calibration Branch Responsibilities

Ultima. X Series Gas Monitor

SAPCON. User Manual. Capacitance Continuous Level Indicator. . Introduction. . General Description. . Principle of Operation. .

SeTAR CENTRE STANDARD OPERATING PROCEDURE

II. MATERIALS REQUIRED FOR PERFORMANCE TESTING

Institute For Thermal Processing Specialists

Kansas State University Fume Hood Operation

Vehicle-mounted meters, pump supplied

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

TV-114 TV-114-A Wind Speed Sensor User s Manual

Guide No. 2/2009. Design, training and equipment Martin Firlus. Physikalisch Technische Bundesanstalt Braunschweig und Berlin

White Paper. Chemical Sensor vs NDIR - Overview: NDIR Technology:

UNDERSTANDING, ACCELERATED

Instrumentation & Data Acquisition Systems

Rigel 601 CHECKBOX. Instruction Manual. 348A551 Issue 2.0. April Seaward Electronic Ltd. Issue 2.0

LK-SX CO 2 +VOC. Application. Security Advice Caution. Notes on Disposal

Model PDT Dewpoint Transmitter

RM-80 respiration monitor

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

Oxygen Meter User Manual

Sensor Stability. Summarized by Breck Owens David Murphy, Sea-Bird Electronics AST-14 Wellington March 18-21

HUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0

THERMAL MASS FLOW MEASUREMENT FOR GASES

OxyCheq Expedition-X Oxygen Analyzer. Operator s Manual

TS1. Ultrasonic Tank Sender. Installation and Operating Instructions. For TS1 Firmware v3.8. Page 1 INST-TS1-V13 18/11/10

Heavy Duty Dissolved Oxygen Meter

This test shall be carried out on all vehicles equipped with open type traction batteries.

GasSense NDIR User Manual

BGA244 Binary Gas Analyzer

Nuclear Associates

Electronic Volume Correctors

Thermo Probe, Inc. TP-5 TP-7 TP-8. Instruction Manual English. Switch. Display. Carry Strap. Probe. Ground Clip. Switch. Display.

628 Differential Pressure Decay Leak Tester

Malema Sensors M-2700 Integrated Ultrasonic Flow Meter

An Automated High Precision Saturation/Dilution Calibration System for Trace Moisture Sensors

Transcription:

Page 1 WBEA Standard Operating Procedure SOP Title Temperature and Relative Humidity Author Gary Cross Implementation date March 2, 2013 Revision History Revision # Date Description Author

Page 2 Table of Contents Introduction and Background... 3 Principle of the Method... 3 Measurement Range and Sensitivity... 4 Equipment and Apparatus... 4 Interferences... 4 Precision and Accuracy... 4 Site Requirements... 5 Installation Requirements... 5 Operating Parameters and Instrument Configuration... 6 Operational and Maintenance Requirements... 6 Calibration Requirement... 6 Temperature probe... 6 Reference Equipment... 6 Procedure... 7 System Verification Check... 7 Relative Humidity probe... 7 Reference Equipment... 7 Reference Procedure... 8 System Verification Check... 8 Data Collection and Management... 9 Reference Documents... 10

Page 3 Introduction and Background This procedure is intended to convey the knowledge required to operate, calibrate and maintain ambient temperature and relative humidity sensors. Temperature data is collected at all WBEA ambient monitoring stations, typically at the 2 metre height, with several stations measuring at various intervals from 2 to 167 meters. This method adheres to the requirements of the current Air Monitoring Directive (AMD) drafted by Alberta Environment in 1989. In some cases the limits and specifications exceed the requirements of the current AMD and subsequent amendments. It should be considered that the current and any future amendments or drafts of the AMD will be used as the benchmark for requirements and criteria for ambient air monitoring practices conducted in the WBEA network. Information used to write this procedure was also taken from sources identified in the reference section. Principle of the Method Temperature in ambient air is measured using a thermistor sensor mounted within an aspirated protected shield. The typically white shield is to reduce the effect of solar energy, as well as terrestrially reflected energy. Thermistor is a device that s name describes its function; a thermal resistor. There are two types of thermistors one which has a resistance that decreases as temperatures rise as with Negative Temperature Coefficient (NTC) and one which the resistance increases as temperatures rise as with Positive Temperature Coefficient (PTC) Thermistors. The majority of thermistor sensors used in the application of air quality monitoring use NTC style thermistors. The thermistor is for the most part made up of a solid state metal oxide ceramic which when heated decreases the amount of resistance in the probe. The temperature is then calculated by measuring the difference in the direct current (DC) voltage. This produces a resistance charge inversely proportional to the ambient temperature being monitored and is sent either as an analog signal to the Data Acquisition System or interrogated digitally via serial connection. The method used to measure Relative Humidity (RH) in ambient air is that of a shielded probe unit combined with a translation system. The RH sensor is typically combined in the same housing with the temperature sensor and is mounted in one radiation shield. The sensor operates by measuring the capacitance change of polymer film capacitor. A porous one micron thin dielectric polymer layer draws molecules of water by metal electrodes; the water molecules change the capacitance in a manor directly proportional to the relative humidity. Because the polymer layers are so thin, the sensor reacts quickly to changes in RH with minimal lag in response. The voltage change is calculated by the in-sensor translator and sent either as an analog signal to the Data Acquisition System or communicated via serial connection.

Page 4 Measurement Range and Sensitivity Ambient temperature sensors used in this method are commercially available models. The measurement range of temperature is typically -50 C to +50 C. Range sensitivity is typically ± 0.1 C. Please refer to the instrument specific installation and operating instructions for more information on range and sensitivity. Relative humidity sensors used in this method are commercially available models. The measurement range is 0 100% of relative humidity within a temperature range of -20 C +60 C. Please refer to the instrument specific installation and operation instructions for more information on range and sensitivity. Equipment and Apparatus The following are commercially available sensors are used by WBEA in this method: Met One Models: 64-2, 592, T200 Vaisala HMP 155 RM Young 43440 Interferences Interferences with temperature measurement accuracy can be caused by improper location of the sensor. Improper mounting can result in the probe being exposed to direct solar energy and even to ventilation of a permanent shelters air conditioning. It should also be noted that glass enclosures, mounting within or next to windows also increases solar energy albedo and magnification effects and can give false readings. Dust and debris may also build up within the shield aspiration which may affect the flow and over all ambient temperature reading. Proximity to large paved areas, open water and other sources of artificial heat will also affect the ambient temperature of an area. Interferences with relative humidity measurement accuracy can be caused by improper location of the sensor. Dust and debris may also build up within the shield aspiration which may affect the flow and over all relative humidity reading. Dust and particulate matter on the sensor it s self can affect the pores of the polymer capacitor and absorb water. The same problem will occur if the sensor is accidentally touched during cleaning; oils from skin can transfer to the polymer and greatly affect the accuracy of measurement. Precision and Accuracy The measurement precision is generally considered to be the repeatability of the measurement. Precision of the data output by the sensor is established by the manufacturer, but confirmed by reference during monthly site visits as well as annual National Institute of Standards and Technologies references.

Page 5 The accuracy of the sensor is generally considered the deviation from true. This means how close it is to what it should be. The benchmark of what it should be is provided by the Alberta Environment Audit Program staff and the use of high quality standards such as available from the National Institute of Standards and Technology (NIST). Refer to the sections identified above for further information on accuracy relating to referencing and audit procedures. Site Requirements Site location of ambient temperature and relative humidity monitoring station should be determined according to the intended application of the monitoring data. As the Alberta Air Monitoring Directive does not have specific criteria regarding the placement and site requirements of ambient temperature monitoring referenced documents include; California Air Resources Board Air Monitoring Quality Assurance Standard Operating Procedures for Air Quality Monitoring, Volume II, Section 2.0.4 (Siting Criteria for Meteorological Equipment) and the Guidance Document on Achievement Determination- Canada Wide Standards for Particulate Matter and Ozone. ISBN: 1-896997-41-4 PN 1330, October 2002, Canadian Council of Ministers of the Environment. Installation Requirements All the installation requirements as specified by the manufacturer in the installation procedures as well as the general requirements below must be followed. Buildings, trees and vegetation can cause disturbance of airflow patterns and relative humidity which can affect measurements. To minimize this effect, the distance between the sample probe and the drip line of the tree must be at least twice the height of the tree, building or other obstruction above the inlet probe or at least 10 meters away whichever is greater. It is recommended that the probe be placed over top of grass or natural earth. Free standing water, concrete, asphalt and other surfaces should be avoided as they may cause artificial heating and cooling of ambient air which may affect the relative humidity within a localized area. In an ideal situation it is recommended that temperature sensors be located between 1.25 and 2 meters above ground, however any tower mounted sensors will encounter interferences with the permanent shelter at this height. As such the sensor should be mounted on a boom extending 1 meter past the roof of the site at 1.25 to 2 meters above the roof height. A data acquisition system is used to record the signal output from the sensors. For connection to record analog voltage signals, the system should be set to match the voltage range of the translator output. Generally this is 1V or 5V full scale and is scaled to convert the output signal to engineering units. See the instrument manufacturer and DAS operations manual for instructions on configuring these channels. Range Set the range of each system is identified in the operations manual. The range set for relative humidity is 0 100%. This is done as soon as the system is powered up after installation. Refer to the operations manual for instructions on this procedure.

Page 6 Operating Parameters and Instrument Configuration Configuration is completed at the CR300 datalogger where the output signals of the sensors are captured, stored and converted to engineering units. Consult the sensor manual for specific configuration details. Operational and Maintenance Requirements The following table of activities must be performed when operating a continuous ambient temperature and relative humidity sensors. Operational and maintenance manuals must be accessible to the operator on site. Analyzer Operational Requirements Action Set data system range System Verification Check Time and Frequency After installation weekly Procedure Documentation Action by As per operations manual Visual check and verification of data values Cleaning Semi-annually See Calibration Section as well as operation manual Accuracy Audit monthly See Calibration Section as well as operation manual Calibration Requirement Entry to Doc-It and Met Calibration Report Entry to Doc-It Entry to Doc-It Entry to Doc-It and calibration form Station operator Station operator Station Operator Station Operator Ambient Temperature and Relative Humidity are factory calibrated sensors; however, the accuracy of the unit must be challenged by performing reference checks monthly as well as before and after any maintenance performed on the instrument. This section will describe the daily and weekly verification checks as well as the process involved in referencing the unit against NIST certified material. Temperature sensor Ambient temperature sensors are referenced and calibrated at the factory when new. Calibration of the sensor is not possible in the field, so reference checks are completed and adjustments can be made to the signal conditioning in the datalogger if required. This is done by referencing the sensor against a known NIST traceable standard. Reference Equipment National Institute of Standards and Technology certified thermometer Insulated container or bath

Page 7 Water Ice Procedure Flag the channels collecting the data for the ambient temperature as down for calibration. Open the RTMC screen to monitor the signal during the calibration. Fill the bath with ice and water stirring to achieve uniform temperature and minimal thermal stratification. Place the thermistor and thermometer at the same level and allow both to stabilize. Record both readings in the applicable calibration form. Use the water at room temperature, approximately 20 C, repeat the process and record both readings in the calibration form. If needed, the slope and offset can be adjusted in the CR3000. Return the temperature sensor to its original location and ensure all cables are connected and the data is flagged back to normal operating conditions. System Verification Check During site visits technicians should verify operation by referencing the station temperature to a thermometer to get a comparison at ambient temperature. The thermometer must be shielded from external heat/solar energy sources, aspirated and located at the same height as the thermistor. If it is at all possible it is strongly recommended that the reference thermometer be placed beside the thermistor to reproduce the exact conditions. Relative Humidity sensor Relative Humidity sensors are referenced and calibrated at the factory when new. Calibration of the sensor is not possible in the field, so reference checks are completed and adjustments can be made to the signal conditioning in the datalogger if required. This is done by referencing the sensor against a known NIST traceable standard. A primary standard RH sensor traceable to the National Institute of Standards and Technology (NIST) is used for this application. Reference Equipment NIST primary standard RH sensor Psychrometer, either sling or battery-fan powered. Distilled water Psychrometric chart

Page 8 Reference Procedure The reference transfer standard sensor should be positioned in the immediate vicinity of the sensor to compare resulting data. Flag the channels collecting the data for the relative humidity as down for calibration. Open the RTMC screen to monitor the signal during the calibration. Record the output from the NIST sensor and the data from the RTMC screen for the ambient sensor on the calibration sheet. Repeat these observations and record 5 times a minimum of 5 minutes apart. Calculate a new slope and offset if required. Return the sensor to active data capture for ambient readings. If an electronic transfer standard is not available the method to determine relative humidity via sling psychrometer is as follows: Use the distilled water to wet the wick of the wet bulb thermometer. The amount of water may vary depending on the make, see operating manual for details, however enough to ensure the wick is fully wet. Place both thermometers in the psychrometer and ensure it s properly contained as well as aspirated to ensure proper air flow. If the psychrometer uses a fan or pump to allow for airflow to move past the thermometers turn this on and allow to stabilize in an area as close to the relative humidity sensor as possible. It is best to avoid direct sunlight or artificial heat sources as these will affect the temperature differential and will throw the humidity calculations. Allow to stabilize for ten minutes. If a sling psychrometer is being used the same conditions apply, try to get the reading as close to the sensor as possible within safe working conditions. As the operator will be spinning the psychrometer it will be very important to avoid any obstructions within the path. Spin the psychrometer for ten minutes and reach stability. calculate the difference between the dry bulb and the wet bulb and follow the psychrometric chart to determine the relative humidity. Repeat this process three to five times to find an average relative humidity reading and compare with the readings the sensor unit is finding. If the unit is more than 15% out it is considered a fail in an AENV audit, as such, if the findings of the reference are greater than 15% out the unit must be shipped to factory to be recalibrated. System Verification Check While more challenging than temperature, it is recommended that operators visually reference the operation of the relative humidity sensor regularly. During mid-day hours where the ambient temperature is high the relative humidity should be at its lowest. During rain storms, if the time and duration is known, the relative humidity sensor should read at or near 100%.

Page 9 Data Collection and Management Ambient temperature and relative humidity sensors should be wired to the station Campbell s CR3000 Datalogger. For more specific information consult the operator manual to determine specific output voltage and ranges. This data recorded at 5 minute intervals and is then polled remotely via cellular modem. It is a best practice to down load all the data filed into a separate storage device monthly to ensure data is backed up.

Page 10 Reference Documents Vaisala model HMP155 Temperature/RH operations manual Met One Model 064-1/064-2 Temperature Sensor Operations Manual Campbell Scientific HMP 45C Temperature and Relative Humidity Sensor Operations Manual Guidance Document on Achievement Determination-Canada Wide Standards for Particulate Matter and Ozone. ISBN: 1-896997-41-4 PN 1330, October 2002, Canadian Council of Ministers of the Environment. CARB Air Monitoring Quality Assurance Standard Operating Procedures for Air Quality Monitoring, Volume II, Section 2.0.4 (Siting Criteria for Meteorological Equipment) Measurement of Ambient Air Temperature using Solid State Sensors, Ambient Air Monitoring Program Methods, Method No.: AQ02/01/14.00M, Greater Vancouver Regional District, Air Quality and Management Division.