LAMINAR FLAME SPEED ANALYSIS USING PIV (PARTICLE IMAGE VELOCIMETRY)

Similar documents
R I T. Title: Amray 1830 SEM Semiconductor & Microsystems Fabrication Laboratory Revision: A Rev Date: 09/29/03 1 SCOPE 2 REFERENCE DOCUMENTS

Operating Procedures for Metal Evaporator I

Trion PECVD SOP IMPORTANT: NO PLASTIC, TAPE, RESISTS, OR THERMAL PASTE ARE ALLOWED IN THE CHAMBER

5.1.3 Mechanical Hazards Drive assemblies have sufficient power to cause injury. Keep hands, fingers, clothing and tools clear of moving parts.

Usage Policies Notebook for NanoFurnace Furnace (EasyTube 3000 System)

Hot Compressed Air Lance Operation Manual. LAB Manufacturing 9483 Reading Road Cincinnati, OH (800)

Gas Absorption Draft Standard Operating Procedure

Safe Work Instructions For Oxygen Acetylene Equipment

Working Environment Safety Assessment

Armfield Distillation Column Operation Guidelines

Warnings: Notes: Revised: January 8,

OAI Model 200 Tabletop Mask Aligner Portland State University

OXYGEN ACETYLENE WELDING & CUTTING EQUIPMENT

Exercise 5-2. Bubblers EXERCISE OBJECTIVE DISCUSSION OUTLINE. Bubblers DISCUSSION. Learn to measure the level in a vessel using a bubbler.

Operating Instructions

Login to ilab Kiosk. Revised 05/22/2018. Load your sample:

OXY FUEL SYSTEM SET UP & SHUT DOWN PROCEDURE CHECKLIST ACETYLENE FUEL GAS

Standard Operating Procedure #COE-SOP-0001 Chemical Fume Hood Operation

Instruction Manual VCG-6

Procedure for Operating Columbia (Nevis) LHe Electron Bubble Chamber Cryostat. Version 5.1

General Specifications: Forensic. Petrochemical Environmental. Lab Quality Analyses in the Field, It Goes with you Anywhere!

COBILT CA-800 Mask Aligner Equipment Operation

In Response to a Planned Power Outage: PPMS EverCool II Shut Down and Re-start Procedure

Cover Page for Lab Report Group Portion. Compressible Flow in a Converging-Diverging Nozzle

Cover Page for Lab Report Group Portion. Boundary Layer Measurements

INSTALLATION GUIDE Gas Rangetops

Cover Page for Lab Report Group Portion. Flow Visualization in a Water Channel

1. Study the performance of a binary distillation column operated in batch mode.

Approved by Principal Investigator Date: Approved by Super User: Date:

The University of Hong Kong Department of Physics Experimental Physics Laboratory

KARL SUSS MJB3 MASK ALIGNER STANDARD OPERATING PROCEDURE

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

Hazards associated with the gas system and how to mitigate them

BASIC RULES OF USAGE, OLIS DSM-20 CD Management The instrument is currently managed by the Analytical Biophysics Core Facility.

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

LEO 1525 FEG SEM Standard Operating Procedures Mar. 6, 2012 For additional assistance, please contact the facility manager.

Model 130M Pneumatic Controller

Equipment Operating Procedure Glove Box

Users Guide for the Vertical Bunsen Burner Test for Cabin and Cargo Compartment Materials FAA Handbook Chapter 2

IBP - YAG. Users Guide. Version No Ophir-Spiricon Inc. 60 W N. Main Logan, UT 84321

CENTRAL GAS SUPPLY SYSTEMS : CYLINDER BATTERIES AND HIGH PRESSURE HOSES

Standard Operating Manual

Operation of the contact mask aligner Canon PPC 210 Projection Print Camera

5890II GC Standard Operating Procedure 9/2/2005

OPERATION MANUAL NTF-15

Standard Operating Procedure Inductively Coupled Plasma Optical Emission Spectrometer (ICP-OES) - Thermo Scientific icap 6300

OPERATION MANUAL NTF-60 Plus

Columbus Instruments

AQUARIUS. Operating Instructions for the. Type 70 Electrolytic Gas Soldering / Welding Unit. Table of Contents

with O 2 Controller Instruction Manual

Approved by Principal Investigator Date: Approved by Super User: Date:

Inert Air (N2) Systems Manual

Cover Page for Lab Report Group Portion. Compressible Flow in a Converging-Diverging Nozzle

INSTALLATION AND OPERATING INSTRUCTIONS BIG TEX VENTED GAS LOGS

3010 MINIFID PORTABLE HEATED THC ANALYSER OPERATING MANUAL

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

Appendix: Simplified Instructions for Operating the HP 5890 GC/FID and Air Sampling Systems

Nanofabrication Facility: ECR Etcher SOP Rev. 01b, March 06. Standard Operating Procedure for PlasmaQuest ECR II Etching

Multiple Gas#5 GC configuration Jan 2016

Agilent Auxiliary Gas Module AGM 2. User s Guide

1)! DO NOT PROCEED BEYOND THIS MARK

ACV-10 Automatic Control Valve

AUTOMATIC TIRE INFLATOR # MW-60, MW-60-4WAY & MW-64HP

INSTRUCTIONS FOR SCORPION TORCHES

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N

GA-300 Gas Analyzer. Technical Note. Overview. Front Panel. iworx Systems, Inc. GA-300

2 Switching off ECRIS 3. 4 Acquire Beam Spectrum 4. 6 Vent Instrument Chamber 5. 7 Pump down Chamber 5. 8 Baking out Chamber 5.

Agilent ICP-MS Interactive Troubleshooting tool for Low sensitivity

Doc No: WELDHOT Midland Engineering Co., Inc. Initial Issue Date 12/14/15 Safety Management System

Gas Cabinets and Valve Manifold Boxes: Applying CGA G13- Rev 2015 to Gas Delivery Equipment

LNG Regulator Test Kit

8.1 Calibration of gas sensors

This test shall be carried out on all vehicles equipped with open type traction batteries.

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

FX134, FX1234, FX3030 Problem and Solutions

300 Held Drive Northampton Pa

Pump out insert (condenser and still lines) overnight with turbo pump

CHEMICAL ENGINEERING LABORATORY CHEG 239W. Control of a Steam-Heated Mixing Tank with a Pneumatic Process Controller

VERTICAL AIR COMPRESSORS

INSTRUCTIONS FOR THE KOBUKI TORCH

NanoSight NS300. NanoSight NS300. Operation instructions. Laser Spectroscopy Labs, UCI

Issue: H Title: CHA E-Beam Evaporator Page 1 of 7. Table of Contents

SSI Solaris 150 RTA Revision /27/2016 Page 1 of 9. SSI Solaris 150 RTA

TRADE OF HEAVY VEHICLE MECHANIC

CHEMICAL ENGINEERING SENIOR LABORATORY CHEG Initiated Chemical Vapor Deposition

Standard Operating Manual

Warnings: Notes: Revised: October 5, 2015

[needs to be discussed with faculty if any new material to be done]

Bubble Tube Installations

Karl Suss MA6 Mask Aligner SOP

Glasgow City Council EDUCATION SERVICES. Technician Support Service

NGP-250/500 Nitrogen Generator Quick Start Guide

Navigator 600 Silica analyzers

XDF BURNERS DUAL FUEL EXCESS AIR BURNER FEATURES DESCRIPTION EXCESS AIR OPERATION

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

Glove Box Installation Manual

Cover Page for Lab Report Group Portion. Head Losses in Pipes

Powermax machine-side reference guide For mechanized applications with Powermax1000, Powermax1250 and Powermax1650

Instruction Manual. Biogas Analyzer InCa Bio 04

Mass Spec will not Autotune

Transcription:

LAMINAR FLAME SPEED ANALYSIS USING PIV (PARTICLE IMAGE VELOCIMETRY) OPERATIONAL PROCEDURES Venue: Project Room, Hopkinson Lab, CUED Experimental date: 25 March 2008 Prepared by: Cheng Tung Chong (ctc31@camacuk) Supervised by: Prof Simone Hochgreb Content 10 Introduction 20 Objectives 30 Procedure descriptions 31 Room preparation 32 Experimental set-up 33 Experimental procedures 331 Seeder test 332 Burner test 333 HFR500 Fast FID test 334 Burner with PIV system 40 Nd:YAG Laser Set-up for PIV 41 Starting the Laser 42 PIV alignment 43 Turning off laser 50 Safety procedures 51 Laminar burner 52 Gas cylinder 53 Acetone 54 Particle seeder 55 HFR500 Fast FID 56 Laser equipment 60 Related documents 70 Appendixes

10 Introduction This document describes the operational procedures of measuring laminar flame speed of methane-acetone-air mixture using PIV system in the Project room of Hopkinson lab 20 Objectives The objectives of the experiment are as follows: (a) To determine the velocity field of laminar flame (b) To familiarize with PIV and FID measurement technique 30 Procedure descriptions 31 Room preparation The project room layout is shown in Appendix 1 The room has one entrance door and an emergency exit door The front door has an electronic lock that requires access password Once the experimental apparatus is set up, follow the steps below: 1 The operator is to wear a CO detector at all times 2 Check methane pressure gauge is at set point from previous run If there is significant pressure drop, perform leak testing 3 Turn on the exhaust fan 4 Ensure that the entrance and fire exit door are not blocked 5 Make sure flammable liquid and materials are placed at safe spot 6 Test the emergency stop solenoid to ensure that it is in fine working condition 7 On the methane line, close ball valve, followed by bottle valve (To enable leak test) 8 Make sure laser safety goggle is worn when PIV system is initiated 9 Make sure the laser interlock system is working 32 Experimental set-up The experimental apparatus is shown in Figure 1 The air flow is supplied by an air compressor while the methane is supplied from a compressed cylinder The air flow is split into 2 lines, one is used to bubble the acetone to saturate the air, and another line is for seeding purposes with one bypass line Aerosil Amorphous Silica R812 S is chosen as the particles to be seeded with air flow because they are good light scatterer with average particle size of 7 nm The seeded air flow will mix with the corresponding amount of methane and acetone-saturated air to achieve the desired mixture before being burnt at the burner at laminar condition The acetone-saturated air line is heated with Omega rope heater that is wrapped around the PTFE tube to prevent condensation The particles in the flame will be illuminated by the double-pulsed laser sheet A co-flow of nitrogen is provided to shroud the mixture to prevent perturbation from surrounding The flame is impinged onto a ceramic plate held by a water cooling system The light source of PIV is

Nd:YAG 120 mj, New Wave Gemini, with second harmonic generating crystals used to create a Q-switched laser output at 532 nm The laser beam will go through a combination of spherical-cylindrical lenses to give a planar laser sheet Two successive flame image will be recorded with a 135 mm Nikkon lens (f:1/28) through a high resolution CCD camera with the array of 2044 x 2044 pixels Computer Exhaust CCD Camera 2 stage regulator Flashback arrestor Ball valve 1 Ceramic plate Beam dump Water out CH 4 Rotameter 1 Water in Nd:YAG laser Air Ball valve 2 Needle valve 1 Particle seeder Burner Lenses Enclosure Rotameter 2 Air line 1 Needle valve 2 Pressure gauge Heated Air line 2 Rotameter 3 Needle valve 3 Ball valve 3 Thermoregulator Drestchel bottle N 2 Rotameter 4 Figure 1: Experimental set-up 33 Experimental procedures 331 Seeder test 1 Turn on the exhaust fan and wear face mask 2 Make sure rotameter 1 and 3, two stage regulator of methane and nitrogen are closed 3 Open the ball valve 2 and needle valve 1 4 Adjust the air pressure regulator to 1 bar 5 Regulate rotameter 2 to flow rate of 20 l/min 6 Slowly close the bypass line by regulating needle valve 2 while open needle valve 1 slowly 7 Observe the seeded flow from the burner outlet 8 The adjustment is tuned until a steady uniform of visible particle stream is obtained

9 Once a steady flow is obtained, maintain the setting of needle valve 1 and 2 10 In order to shut the system, close ball valve 2, let the air purge the system for 2 minutes 11 Regulate rotameter 2 to zero 12 Close the pressure regulator of air 332 Burner testing 1 Turn on the exhaust fan, CO detector and wear face mask 2 Turn on the water pump 3 Open ball valve 1 4 Check every connection to make sure it is properly secured with no leakage 5 Adjust the pressure regulator of methane to 05 bar 6 Regulate rotameter 1 7 Light the burner with a lighter 8 Use the leak detector to check for leakage at connections 9 Regulate rotameter 1 to zero 10 Close the pressure regulator of methane and valve 1 11 Open valve 2 12 Regulate rotameter 2 13 Regulate needle valve 1 and 2 to ensure a smooth stream of particles 14 Use leak detector to check for leakage at connections 15 Adjust the pressure regulator of methane to 05 bar 16 Regulate rotameter 1 (refer Appendix 2) 17 Check the seeding is flowing uniformly and regulate needle valve 1, 2 if necessary 18 Light the burner with a lighter 19 The flame is observed for its stability 20 Adjust the pressure regulator of nitrogen tank to 05 bar 21 Regulate rotameter 3 to provide co-flow for the flame, 22 Observe the flame stability 23 Repeat the experiment with different flow rate (Refer Appendix 2 for different flow rate) 24 To shut the system, regulate the methane flow rate (rotameter 1) to zero 25 Close ball valve 1, then close methane tank valve (To enable leak test) 26 Close ball valve 2 27 To shut the nitrogen flow, regulate rotameter 3 to zero 28 Close the nitrogen tank valve 29 Vent the pressure from the regulator 30 Let the air run to purge the system for a minute 31 Regulate rotameter 2 to zero 32 Turn the knob of the regulator back to zero 33 Close the valve of the compressed air and turn the pressure regulator back to zero 34 Turn off the pump

333 Flame Ionization Detector (FID) testing FID testing is a separate test to examine the concentration of acetone The FID is run exclusively from the main system and therefore not included in the Figure 1 The test is conducted prior to the usage of PIV system and HFR500 Fast FID by Cambustion Limited is used Starting the analyzer 1 Switch on the service control unit, the vacuum pump and the computer 2 Turn on the hydrogen-helium, nitrogen-propane gas and air line to 2 bars 2 Start up the user-interface by double-clicking on the appropriate desktop icon 3 Click and drag down the pull-down menu and select On for Channel 1 4 If the FID flame lights lit successfully, the sample head will warm up for 10-15 min Calibrating and Sampling 1 Select Options from the status pull-down menu 2 Enter correct calibration gas values for span A for HC 3 Select the output range 4 Begin calibrating by selecting Calibration 5 Once calibrated, the Gas Select box will appear green 6 Place the sample probe at the burner exit 7 Draw the sample in by clicking the Sample button Shutting down 1 Switch status indicator from On to Off 2 Exit the User-interface program by pressing Exit 3 Switch off service control Unit 4 Switch off vacuum pump 5 Shut the Computer 6 Switch off power supply to the computer 7 Switch off power supply source to the cabinet 8 Shut off all gas supplies at source 334 Burner with PIV system 1 Turn on the exhaust fan, CO detector and wear face mask 2 Check every connection to make sure it is properly secured with no leakage 3 Fill the Drestchel bottle with acetone and connect to the tube 4 Adjust the pressure regulator of methane to 05 bar 5 Open ball valve 1 6 Regulate rotameter 1 7 Light the burner with a lighter

8 Turn the compressed air regulator to 1 bar 9 Regulate rotameter 2 10 Check the seeding is flowing uniformly and regulate needle valve 1 and 2 if necessary 11 Regulate the rotameter 3 to bubble the acetone 12 Turn on the water pump for the cooling system 13 The flame is observed for its stability 13 WEAR laser safety goggle before turning on the Nd:YAG laser 14 Ensure that the enclosure is accessible with no blockage 15 Activate the laser interlock system 16 Turn on the Nd:YAG laser by following the standard procedure described in section 41 17 Check the sheet formation with a white card 18 Check for light scattering from the metallic part of the burner 19 Take the flame images with the CCD camera 20 Repeat procedure 6, 8-11 for different flow rates as shown in Appendix 2 40 Nd:YAG laser operational procedures 41 Starting the laser 1 Close the shutter of the laser head 2 Connect the laser power cord with appropriate single phase power source Place the power switch on the AC entry module to ON position 3 Turn the power supply key switch clockwise to the ON position 4 Rotate the Flashlamp Voltage knob counter clockwise to the minimum at START position 5 Press START/STDBY mode button on the control panel until the power supply INTERLOCK LED is off and the control panel LASER EMISSION LED is on 6 After the LASER EMISSION LED is illuminated, there is an eight seconds delay before laser firing can occur 7 Use the trigger selection switch to select the desired operation mode 8 Open the shutter to begin operation 9 Press the Fire button on the control panel to initiate laser firing Pressing the Fire button in 1 Shot mode will fire one shot Pressing the Fire button in Variable or Fixed mode will fire the laser at the set repetition rate 10 Rotate the Flashlamp Voltage knob clockwise until the desired relative energy is achieved 42 Alignment for PIV 1 Remove the smaller optics head cover to provide access to the beam combining optics and second harmonic generator Install the interlock defeat mechanism

2 Put both lasers into standby mode with the flashlamp voltage just above threshold for generating second harmonic light 3 Observe the overlap of the two beams at the point where PIV measurement will be made Adjust the polarizer assembly mount to optimize the overlap of the two beams Note that the top adjustment screw on the mirrors controls vertical beam motion 4 Observe the overlap of the two beams from the measurement area to the laser The alignment is finished if the beams overlap the entire distance 5 Fire laser #1 and observe the position of the visible beam on the folding mirror immediately after the second harmonic generator 6 Fire laser #2 and note the position of the beam on the mirror, relative to the beam from laser #1 Adjust the fold mirror #1 to overlap the two visible beams immediately after the second harmonic generator 7 Observe the overlap of the two beams at a point 1-2 meters away from the laser head 8 Adjust the polarizer assembly mount to optimize the overlap of the two beams 9 Repeat steps 5-8 to get the optimal overlap between the beams from laser #1 and laser #2 The overlap can be observed between the beams from laser #1 and laser #2 The overlap can be observed along the beam line from the laser head exit for several meters 10 Turn off both lasers and reinstall the secondary head cover Check the alignment with both lasers operating at a desired energy Polarizer assembly Laser #1 Optical Attenuator (optional) Laser #2 Figure 2: Gemini PIV Beam overlap adjustment 43 Turning off the laser The laser can be turned off automatically by interrupting the interlock The standard way to turn off the laser is as follow: 1 Rotate the energy knob to the minimum 2 Press the OFF button 3 Turn the power supply key switch to the OFF position

4 Turn off the AC power line switch 5 Close the laser head shutter 50 Safety procedures 51 Laminar burner 1 Wear face mask 2 Ensure that the tubing is free from defects such as cracks 3 Ensure there are no flammable materials near the burner 4 The burner is securely placed underneath the exhaust hood 5 Implement the procedures from 1 to 34 of section 332 6 Stand at an arm length distance to light the burner with a lighter 52 Gas cylinder 1 Only use specific equipment with the compressed cylinder, ie two stage regulators Contact gas supplier if in doubt 2 Keep away from ignition sources (including static charges) 3 Refer to supplier s handling instructions 4 Keep the gas cylinder below 50 o C in a well ventilated place 5 After finishing the experiment, close the cylinder valve Vent the gas in the regulator and purge the system with excessive air 6 Make sure all cylinder tanks are strapped to a holding panel with chains 53 Acetone 1 Use HPLC high grade acetone 2 Keep the bottle in a secured, dry cabinet 3 Ensure that the bottle is tightly closed 4 Keep away from ignition sources (including static charge) 5 Wear face mask when handling acetone 6 Place the acetone bottle in a cool dry place away in store before running the experiment 7 Dispose excessive acetone in a labeled bottle 8 Contact Chief Technician Mike Underwood if there is any doubt 9 Refer to supplier s handling instructions 54 Particle seeder 1 The particle seeder has an emergency 3-bar valve 2 Ensure that face mask and hand gloves are worn at all time 3 Make sure that exhaust is turned on at all time

55 HFR500 Fast FID 1 Always ensure that the pump is located in the base of the cabinet before sliding out the control unit on the shelf 2 The sample heads and sample probes become very hot under normal conditions and must be cooled down before handling 3 Never attempt to fuel the analyzer with pure hydrogen 4 If the pump is an oil-filled vacuum pump, make sure the pump is filled with oil to the correct level 5 When fitting the control unit, make sure another person is present to steady the cabinet and help position the control unit 6 Make sure the switches are correctly set before connecting these units to main power 7 In connecting the heated sample probe to the remote sampling head, it is important that the probe is pushed fully into the calibration adaptor to avoid unnecessary voids remaining in the sample flow path which will cause slow response time 8 Care should be taken when fitting or removing the sample probe as mishandling of the sample probe can fracture the inner capillary 9 Always refer to HFR500 Fast FID Hydrocarbon Measurement System User manual of Cambustion Limited 2004 56 Laser equipment Please refer to the laser risk assessment form and local rules 60 Related documents 1 New Wave research Inc Operator s manual for Tempest and Gemini PIV Nd:YAG Lasers, October 2000 2 Dantec Flowmap PIV manual 3 Local rules for Project Room of Hopkinson Lab 4 Laser risk assessment form 5 Risk Assessment form 6 Control of Substances Hazardous to Health (COSHH) forms 7 HFR500 Fast FID Hydrocarbon Measurement System User manual of Cambustion Limited 2004 8 HFR500 Fast FID Simplified Operating Instructions of Cambustion Limited 2004

70 Appendix 71 Appendix 1 Plan view of Project Room 1 3 20 13 2 9 1 3 19 8 4 11 5 7 17 10 12 16 18 6 14 15 1 Front entrance 11 Exhaust fan 2 Emergency exit 12 Burner set up 3 Emergency button 13 Table 4 Partitions 14 CCD camera 5 Storage cabinet 15 Beam dump 6 Air compressor 16 Water tank 7 Exhaust fan 17 Thermoregulator 8 Rotameter panel 18 Table 9 N 2 gas cylinder 19 Methane gas cylinder 10 Nd:YAG laser 20 Gas cylinder holding panel

Appendix 2 1 Methane and air flow rate φ V air CH 4 V V air CH 4 V V air CH 4 V V air V CH 4 060 15 095 18 113 20 126 22 139 070 15 110 18 132 20 147 22 162 080 15 126 18 151 20 168 22 185 090 15 142 18 170 20 189 22 208 100 15 158 18 189 20 210 22 231 110 15 173 18 208 20 231 22 254 120 15 189 18 227 20 252 22 277 130 15 205 18 246 20 273 22 300 140 15 221 18 265 20 294 22 324 150 15 236 18 284 20 315 22 347 160 15 252 18 303 20 336 22 370 170 15 268 18 321 20 357 22 393 180 15 284 18 340 20 378 22 416 φ V air CH 4 V V air CH 4 V V air V CH 4 060 25 158 28 176 30 189 070 25 184 28 206 30 221 080 25 210 28 235 30 252 090 25 236 28 265 30 284 100 25 263 28 294 30 315 110 25 289 28 324 30 347 120 25 315 28 353 30 378 130 25 341 28 382 30 410 140 25 368 28 412 30 441 150 25 394 28 441 30 473 160 25 420 28 471 30 504 170 25 446 28 500 30 536 180 25 473 28 529 30 567 2 As for Nitrogen co-flow, the testing range will be from 29 35 l/min and will be varied accordingly based on observation

Appendix 3 Water out Water in Ceramic plate Figure 2: Cooling system and ceramic plate