TSS21 Sealed Thermostatic Steam Tracer Trap

Similar documents
MST21 Stainless Steel Balanced Pressure Thermostatic Steam Trap

DF1 and DF2 Diffusers

BT6HC Hygienic Sanitary Balanced Pressure Steam Trap for High Capacity and CIP/SIP Applications

DCV10 Stainless Steel Disc Check Valve for use with Condensate Pumps

TA10A and TA10P Steam Tracing Temperature Control Valves Installation and Maintenance Instructions

Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators

AVM7 Stainless Steel Thermostatic Air Vent

TP1 and TP2 Temporary Cone Shaped Strainers

PV4 and PV6 Piston Valves

DCV1, DCV3 and DCV3LT Disc Check Valves Installation and Maintenance Instructions

Dri-Line Mk3 Monnier Compressed Air Drain Trap

AVC32 Carbon Steel Air Vent for Steam Systems

Fig 12, Fig 14HP, Fig 16, Fig 16HP and Fig 16L Strainers

Fig 1, Fig 12, Fig 13, Fig 14HP, Fig 16, Fig 16HP and Fig 16L Strainers

Dri-Line Mk2 Spirax-Monnier Compressed Air Drain Trap

IFTGS14 Ball Float Steam Trap ½" and ¾" with Integral Spiratec Sensor

KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions

DCV6 Disc Check Valve

CVS10 Sanitary Check Valves

BTM7, BTS7 and BTS7.1 Stainless Steel Thermostatic Clean Steam Traps

MSC-P and MSC-N Manifolds for Steam Distribution and Condensate Collection

KBV21i and KBV40i Air Actuated Boiler Blowdown Valves

UIB30 and UIB30H Sealed Inverted Bucket Steam Traps for use with Pipeline Connectors

AE14 Automatic Air Vents for Liquid Systems Installation and Maintenance Instructions

FTGS14 Ball Float Steam Trap DN15 (½") to DN25 (1")

HM and HM34 Inverted Bucket Steam Traps Installation and Maintenance Instructions

CP10 Sensor Installation and Maintenance Instructions

FV Flash Vessel Installation and Maintenance Instructions

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Dial Adjustment)

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators Installation and Maintenance Instructions

CA44, CA44S, CA46 and CA46S Air and Gas Traps

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Knob Adjustment)

PC10HP Pipeline Connector (ASME 600)

Fig 3, 7, 33, 34, 34HP, 36, 36HP, 37, 3616 and Fig 3716 Flanged Strainers

AE30 Automatic Air Eliminators / Air and Gas Vents for Liquid Systems

BPT13 Balanced Pressure Thermostatic Steam Traps

S and SF Inverted Bucket Steam Traps

MF2M Monnier Miniature Compressed Air Filter

Airodyn, BRair and BRoil Compressed Air Drain Traps

IX1 Spirax-Monnier International Compressed Air Filter Installation and Maintenance Instructions

BT6-B Sanitary Balanced Pressure Thermostatic Steam Trap

CS10-1 Stainless Steel Clean Steam Separator

TDC46M, TDS46M and UTDS46M Thermodynamic Steam Traps with Maintainable Seat Installation and Maintenance Instructions

AVS32 Stainless Steel Air Vent for Steam Systems Installation and Maintenance Instructions

Fig 7, 33, 33.1, 34, 34HP, 36, 36HP, 37, 3616 and Fig 3716 Flanged Strainers Installation and Maintenance Instructions

MFP14-PPU (Vented) Automatic Packaged Pump Units

TD62LM and TD62M Thermodynamic Steam Traps with Replaceable Seats

UBP32 Sealed Balanced Pressure Thermostatic Steam Trap for use with PC_ Pipeline Connectors Installation and Maintenance Instructions

SRV66 Sanitary Pressure Reducing Valve

Manual Actuated Boiler Blowdown Valves

M10HTi ISO Tobacco Ball Valve Screwed, SW, BW and Flanged versions

ML3M Monnier Miniature Compressed Air Lubricator

CA10S, CA14 and CA14S Air and Gas Traps

Spirax Compact FREME Flash Recovery Energy Management Equipment

FT16 Ball Float Steam Trap Installation and Maintenance Instructions

M33F ISO, M33S ISO and M33V ISO Ball Valves Installation and Maintenance Instructions

APT14, APT14HC and APT14SHC Spares 2

BDV1 and BDV2 Blowdown / Depressurisation Valves

AE50S Automatic Air and Gas Vent for Liquid Systems Installation and Maintenance Instructions

FT53, IFT53, FT54, IFT54, FT57 and IFT57 Ball Float Steam Traps - DIN

TD62LM and TD62M Thermodynamic Steam Traps with Replaceable Seats Installation and Maintenance Instructions

BCV31 DN40 - Blowdown Control Valve

SA Control Valve types: BM, BMF, BX, SB, NS, KA, KB, KC (Normally open) BMRA, BMFRA, BXRA, SBRA, NSRA, KX, KY (Normally closed)

TW Temperature Control Valve

USM21 Sealed Bimetallic Steam Trap for use with Pipeline Connectors Installation and Maintenance Instructions

SCA Series Inverted Bucket Steam Traps

M70i ISO and M80i ISO Stainless Steel Ball Valves for Sanitary Systems Installation and Maintenance Instructions

Thermocirc Installation and Maintenance Instructions

SRV2S Pressure Reducing Valve

Spirax SafeBloc TM DBB3 Double Block and Bleed Bellows Sealed Stop Valve. 1. Safety information. 2. General product information. 3.

CA16 and CA16S-14 Air and Gas trap Installation and Maintenance Instructions

BCV31 DN20 - Blowdown Control Valve

BRV71 and BRV73 Pressure Reducing Valves

A3S Bellows Sealed Stop Valve Installation and Maintenance Instructions

MPC1M, MPC2M and MPC2AM Monnier High Efficiency Compressed Air Filter / Regulators

QuickHeat TM Packaged Heat Exchanger Solutions

Vane Flow Switches Colima FLU Series

Type 130 and HL10 'Safeguard High Limit Control' Installation and Maintenance Instructions

TD10, TD52M and TD259 Thermodynamic Steam Traps Installation and Maintenance Instructions

BTD52L Thermodynamic Steam Trap Installation and Maintenance Instructions

FTC62 and FTS62 Ball Float Steam Traps Installation and Maintenance Instructions

FT43, FT44, FT46 and FT47 Ball Float Steam Traps Installation and Maintenance Instructions

IP2M, IP2AM and IP2DM Monnier International Compressed Air Filter/ Regulators

M111 Spiraflo Transducer

TD45 Thermodynamic Steam Trap Installation and Maintenance Instructions

1. General safety information. 2. General product information. 3. Installation. 4. Commissioning. 5. Operation. 6. Maintenance. 7.

PC3000, PC3001 and PC4000, PC4001 Pipeline Connectors

Fig 1, Fig 12, Fig 13, Fig 14, Fig 16 and Fig 16L Strainers Installation and Maintenance Instructions

BSA6T and BSA64T Stainless Steel Bellows Sealed Stop Valves Installation and Maintenance Instructions

LP31 Level Probe. 1. Safety information. 2. General product information. 3. Installation. 4. Wiring. 5. Maintenance

BCVi43 Blowdown Control Valve

STERI-TROL Clean Service 'S' Series Two-port Control Valves DN15 (½") to DN100 (4")

BDV60 Blowdown Vessel Installation and Maintenance Instructions

SRV461S and SRV463S Stainless Steel Direct Acting Pressure Reducing Valves

M45 ISO Ball Valve DN25 to 150 Installation and Maintenance Instructions

Colima TOR Magnetic Level Switches

595-K/L and 596-K/L Series Self Operated Valves Installation and Maintenance Instructions

LP10-4 Level Probe. 1. Safety information. 2. General product information. 3. Installation. 4. Wiring. 5. Maintenance IM-P402-92

CA46S Austenitic Stainless Steel Air and Gas Trap DN40 and DN50

Transcription:

1255050/4 IM-P125-10 ST Issue 4 TSS21 Sealed Thermostatic Steam Tracer Trap Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning 5. Operation 6. Maintenance 7. Spare parts IM-P125-10 Printed in the ST UK Issue 4 Copyright 2007 1

2 IM-P125-10 ST Issue 4

1. Safety information Safe operation of this product can only be guaranteed if it is properly installed, commissioned, used and maintained by qualified personnel (see Section 1.11) in compliance with the operating instructions. General installation and safety instructions for pipeline and plant construction, as well as the proper use of tools and safety equipment must also be complied with. 1.1 Intended use Referring to the Installation and Maintenance Instructions, name-plate and Technical Information Sheet, check that the product is suitable for the intended use / application. The product listed below complies with the requirements of the European Pressure Equipment Directive 97/23/EC and carries the mark when so required. The product falls within the following Pressure Equipment Directive categories: Group 2 Group 2 Product Gases Liquids TSS21 SEP SEP i) The product has been specifically designed for use on steam, air or water/ condensate which is in Group 2 of the above mentioned Pressure Equipment Directive. The products use on other fluids may be possible but, if this is contemplated, Spirax Sarco should be contacted to confirm the suitability of the product for the application being considered. ii) Check material suitability, pressure and temperature and their maximum and minimum values. If the maximum operating limits of the product are lower than those of the system in which it is being fitted, or if malfunction of the product could result in a dangerous overpressure or overtemperature occurrence, ensure a safety device is included in the system to prevent such over-limit situations. iii) Determine the correct installation situation and direction of fluid flow. iv) Spirax Sarco products are not intended to withstand external stresses that may be induced by any system to which they are fitted. It is the responsibility of the installer to consider these stresses and take adequate precautions to minimise them. v) Remove protection covers from all connections and protective film from all name-plates, where appropriate, before installation on steam or other high temperature applications. 1.2 Access Ensure safe access and if necessary a safe working platform (suitably guarded) before attempting to work on the product. Arrange suitable lifting gear if required. 1.3 Lighting Ensure adequate lighting, particularly where detailed or intricate work is required. IM-P125-10 ST Issue 4 3

1.4 Hazardous liquids or gases in the pipeline Consider what is in the pipeline or what may have been in the pipeline at some previous time. Consider: flammable materials, substances hazardous to health, extremes of temperature. 1.5 Hazardous environment around the product Consider: explosion risk areas, lack of oxygen (e.g. tanks, pits), dangerous gases, extremes of temperature, hot surfaces, fire hazard (e.g. during welding), excessive noise, moving machinery. 1.6 The system Consider the effect on the complete system of the work proposed. Will any proposed action (e.g. closing isolation valves, electrical isolation) put any other part of the system or any personnel at risk? Dangers might include isolation of vents or protective devices or the rendering ineffective of controls or alarms. Ensure isolation valves are turned on and off in a gradual way to avoid system shocks. 1.7 Pressure systems Ensure that any pressure is isolated and safely vented to atmospheric pressure. Consider double isolation (double block and bleed) and the locking or labelling of closed valves. Do not assume that the system has depressurised even when the pressure gauge indicates zero. 1.8 Temperature Allow time for temperature to normalise after isolation to avoid danger of burns. 1.9 Tools and consumables Before starting work ensure that you have suitable tools and/or consumables available. Use only genuine Spirax Sarco replacement parts. 1.10 Protective clothing Consider whether you and/or others in the vicinity require any protective clothing to protect against the hazards of, for example, chemicals, high/low temperature, radiation, noise, falling objects, and dangers to eyes and face. 1.11 Permits to work All work must be carried out or be supervised by a suitably competent person. Installation and operating personnel should be trained in the correct use of the product according to the Installation and Maintenance Instructions. Where a formal 'permit to work' system is in force it must be complied with. Where there is no such system, it is recommended that a responsible person should know what work is going on and, where necessary, arrange to have an assistant whose primary responsibility is safety. Post 'warning notices' if necessary. 4 IM-P125-10 ST Issue 4

1.12 Handling Manual handling of large and/or heavy products may present a risk of injury. Lifting, pushing, pulling, carrying or supporting a load by bodily force can cause injury particularly to the back. You are advised to assess the risks taking into account the task, the individual, the load and the working environment and use the appropriate handling method depending on the circumstances of the work being done. 1.13 Residual hazards In normal use the external surface of the product may be very hot. If used at the maximum permitted operating conditions the surface temperature of some products may reach temperatures in excess of 300 C (572 F). Many products are not self-draining. Take due care when dismantling or removing the product from an installation (refer to 'Maintenance instructions'). 1.14 Freezing Provision must be made to protect products which are not self-draining against frost damage in environments where they may be exposed to temperatures below freezing point. 1.15 Disposal The product is recyclable. No ecological hazard is anticipated with the disposal of this product providing due care is taken. 1.16 Returning products Customers and stockists are reminded that under EC Health, Safety and Environment Law, when returning products to Spirax Sarco they must provide information on any hazards and the precautions to be taken due to contamination residues or mechanical damage which may present a health, safety or environmental risk. This information must be provided in writing including Health and Safety data sheets relating to any substances identified as hazardous or potentially hazardous. IM-P125-10 ST Issue 4 5

2. General product information 2.1 General description The TSS21 all stainless steel steam tracer trap is a completely sealed unit and therefore has no gasketed joints. It is operated thermostatically using a balanced pressure capsule and is specifically suitable for non critical tracing applications. It is however a dual purpose trap in that it can be fitted in the reverse mode where it will operate as a fixed temperature discharge steam trap. The trap fitted in the reverse mode will limit the downstream temperature to approximately 90 C (194 F) when discharging to atmosphere. In the unlikely event of the trap operating into a pressurized return main the capsule will be affected by the downstream temperature and it s operation under such conditions may be erratic and unpredictable. Standards This product fully complies with the requirements of the European Pressure Equipment Directive 97 / 23 / EC. Certification This product is available with a manufacturers' Typical Test Report. Note: All certification / inspection requirements must be stated at time of order placement. Note: For further product data see the following Technical Information sheet, TI-P125-02. 2.2 Sizes and pipe connections ½" screwed BSP or NPT and socket weld ends to BS 3799 class 3000. Steam tracer trap Fixed discharge temperature steam trap Fig. 1 Shows the direction of flow through a TSS21 when used for the stated application 6 IM-P125-10 ST Issue 4

2.3 Pressure / temperature limits Temperature C Steam saturation curve Pressure bar g As a fixed discharge temperature trap Pressure psi g As a steam tracer trap Temperature F The product must not be used in this region. Body design conditions PMA Maximum allowable pressure PN25 25 bar g @ 200 C (362.5 psi g @ 392 F) TMA Maximum allowable temperature 400 C (752 F) Minimum allowable temperature -254 C (-425 F) Maximum operating pressure for 21 bar g (305 psi g) saturated steam service * PMO Maximum operating pressure when used 7 bar g (102 psi g) as a fixed discharge temperature trap Maximum operating temperature 242 C (468 F) TMO Maximum operating temperature when used 170 C (338 F) as a fixed discharge temperature trap Minimum operating temperature 0 C (32 F) Designed for a maximum cold hydraulic test pressure of: 38 bar g (551 psi g) IM-P125-10 ST Issue 4 7

3. Installation Note: Before actioning any installation observe the 'Safety information' in Section 1. Referring to the Installation and Maintenance Instruction, name-plate and Technical Information Sheet, check that the product is suitable for the intended installation: 3.1 Check materials, pressure and temperature and their maximum values. If the maximum operating limit of the product is lower than that of the system in which it is being fitted, ensure that a safety device is included in the system to prevent overpressurisation. 3.2 Determine the correct installation situation and the direction of fluid flow. 3.3 Remove protective covers from all connections and protective film from all name-plates, where appropriate, before installation on steam or other high temperature applications. 3.4 The trap is intended for installation in a vertical line with flow vertically downwards. For tracing applications observe the direction of the red arrow on the trap body. For fixed discharge temperature applications observe the direction of the black arrow on the trap body. This will ensure that the trap is self-draining. Steam tracer trap Fig. 2 Fixed discharge temperature steam trap 3.5 When the trap is installed in its fixed discharge temperature mode it must discharge to atmosphere. The trap has not been designed to operate when discharging into a pressurised return main - under such conditions its operation will be erratic and unpredictable. 3.6 Note on welding: When welding the socket weld version into the line, the electric arc process should be used. If both ends are being welded e.g. on tracing applications, then it is important to complete one weld and let it cool before starting the second weld in order to prevent the risk of damage to the internal capsule. Note: If the trap is to discharge to atmosphere ensure it is to a safe place, the discharging fluid may be at a temperature of 100 C (212 F). 8 IM-P125-10 ST Issue 4

4. Commissioning After installation or maintenance ensure that the system is fully functioning. Carry out tests on any alarms or protective devices. 5. Operation 5.1 As a tracer trap The operating element is a capsule containing a small quantity of a special liquid with a boiling point below that of water. In the cold conditions that exist at start-up, the capsule is relaxed. The valve is off its seat and is wide open, allowing unrestricted removal of air. This is a feature of all balanced pressure traps and explains why they are well suited to air venting. As condensate passes through the balanced pressure steam trap, heat is transferred to the liquid in the capsule. The fill liquid boils before steam reaches the trap. The vapour pressure within the capsule causes it to expand and the trap shuts. Heat loss from the trap then cools the water surrounding the capsule, the fill condenses and the capsule contracts, opening the valve and releasing condensate until the steam temperature rises again at which point the cycle is repeated. Steam tracer trap Fig. 3 Fixed discharge temperature steam trap 5.2 As a fixed temperature discharge trap When fitted in the reverse mode, the label will read 'Fixed temperature discharge PMO 7 bar (101 psi ) TMO 170 C (338 F). This 'TMO' refers to the maximum downstream temperature which the capsule can withstand. Of course, the maximum upstream conditions can be 7 bar (101 psi) at the appropriate saturation temperature of 170 C (338 F). The capsule is now on the downstream side of the seat orifice and is protected from upstream temperature. It will then operate at a temperature of approximately 90 C (194 F) discharging sub-cooled condensate. It will open at this temperature irrespective of steam pressure. In this mode it can be used for instrument and non-critical steam tracing lines, where some use is made of the sensible heat in the condensate. IM-P125-10 ST Issue 4 9

6. Maintenance The TSS21 is a sealed stainless steel, thermostatic balanced pressure steam tracer trap. It is non adjustable and requires no maintenance. 7. Spare parts The TSS21 is a sealed, non maintainable, steam tracer trap. Therefore, no spare parts are available. 7.1 How to order a new product Example: 1 off ½" Spirax Sarco TSS21 sealed thermostatic steam tracer trap having screwed NPT connections. 10 IM-P125-10 ST Issue 4

IM-P125-10 ST Issue 4 11

12 IM-P125-10 ST Issue 4