Net$ync II. Net$ync II. System Controllers

Similar documents
Ingersoll Rand. X-Series System Automation

QGV Series. Quincy QGV Series. Rotary Screw Air Compressors hp

Let s examine the evolution and application of some of the more popular types. Cascading Pressure Type

Screw Compressors 11-22kW

WF STEUERUNGSTECHNIK GMBH. INFORMATION and TECNICAL DESCRIPTION

Which compressed air system design is right for you?

CONTROL SOLUTIONS DESIGNED TO FIT RIGHT IN. Energy Control Technologies

Oil-injected rotary screw compressors GA (VSD + )

RS D RSF D with direct drive

COMPRESSED AIR TEXTILES ENERGY EFFICIENCY

Introduction. 1. Large oil-free screw compressor, Emeraude ALE series

Sullair Air Systems. *Assessment of the market for compressed air efficiency services. Technical report, U.S. Department of Energy, June 2001

HumiSys HF High Flow RH Generator

Nirvana Variable-Speed Drive, Contact-Cooled Rotary Screw Air Compressors

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

RS 2-75 D 109 D RSF 87 D 127 D with direct drive

EasyTouch. Because automation makes it all so simple. Pool and Spa Control Systems. by Pentair Water Pool and Spa

SCIENCE LAB UTILITY CONTROLS

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

COMPRESSOR PACK SUCTION CONTROLLER TYPE: LP41x

SINGLE VALVE WITH LOW-FLOW BYPASS

Touch Screen Guide. OG-1500 and OG Part # T011

4-7 kw/ hp. Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward

EASYTOUCH. Because automation makes it all so simple. pentairpool.com

Potter Nitrogen Generators

AUTOMATIC HOSE TEST UNIT, TYPE SPU

THE IMPACT ON ENERGY CONSUMPTION CAUSED BY PRESSURE DROP IN A COMPRESSED AIR SYSTEM

Fundamentals of Compressed Air Systems. Pre-Workshop Assignment

PRC CO ² -LASER PRESENTATION

Model EXAxt AV550G. Averaging Oxygen Analyzer

BUBBLER CONTROL SYSTEM

Optimization of Air compressor Motor speed for Reducing Power Consumption

Exceptional Experience

Reliability: Piping Distribution & Storage Matter. Instructor: Kurt Thielemann Principal

The Future of Hydraulic Control in Water-Systems

Industrial Compressor Controls Standard Custom

SENSAPHONE APPLICATION NOTE. Functions: C Programming, Pump Control, Data Logging

EasyTouch. Pool and Spa Control Systems By Pentair Water Pool and Spa. Because automation makes it all so simple

TANKTRONIC. STANDARD CONFIGURATION Single Tank. ADVANCED CONFIGURATION Multiple Tanks. Twin Tank (common valve) Twin Tank (separate valves) Vent box

A TECHNICAL REFERENCE

High Pressure Compressed Air and Gas Solutions

Steam Turbine Performance Measurement. Pressure Measurement

Optimizing Compressed Air Storage for Energy Efficiency

SRL SEries. Oil Free Scroll Air Compressors hp kw

AirSep PSA Nitrogen Systems

Multiple Pressure Booster Systems With Variable Speed Controller Type BL

/ /

How to Select High Pressure and Gas Bypass

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

BUBBLER CONTROL SYSTEM

PEAPOD. Pneumatically Energized Auto-throttled Pump Operated for a Developmental Upperstage. Test Readiness Review

Application of CHE100 in Frequency Conversion Alteration of Air Compressor System

DOMESTIC HOT WATER TEMPERATURE CONTROL with SAFEGUARD

CASE STUDY. Compressed Air Control System. Industry. Application. Background. Challenge. Results. Automotive Assembly

UNIVERSAL MASK TEST SYSTEM

Pressure on Demand. Air Pressure Amplifiers

Series 7250 Ruska High-Speed Digital Pressure Controller. GE Sensing. Features

NGN Series nitrogen generator

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

SPECIALTY GASES LASAL. laser cutting and welding technologies. Photo courtesy of Alabama Laser.

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

Advanced Pump Control for Irrigation Applications

11 Air ends 12 Motor 13 Belt driven. 1. ELECTRONIC REGULATION The ES4000 is a control system, designed for medium and high power compressors.

1 STARTUP Overview Buttons Basics of Control Resetting Faults and Alarms OPERATION...

V-Major, V-Compact. Reciprocating Compressors. Intelligent Air Technology

Visualize Nitrogen Gas Consumption

Wireless Groundwater & Surface Water Data Transmission Maximize data quality Reduce operating costs Near real-time insight

Pressure Independent Control Valves

UNIQUE ADVANTAGES OF PIPENET

GAS FILLING MACHINES PROCESS MONITORING PRESSURE BALANCE

Online data sheet FLOWSIC30 GAS FLOW METERS

Understanding Centrifugal Compressor Capacity Controls:

Data Sheet T 8389 EN. Series 3730 and 3731 Types , , , and. EXPERTplus Valve Diagnostic

Nitrogen Advantage. Better Tire Pressure Retention. Improved Fuel Economy. Extended Tread Life. Elimination of Oxidation. Reduction in Tire Failures

Wellhead Safety Valve Control System (Wellhead Control Panel)

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Distributed Control Systems

Connect with Confidence NO POWER NO PROBLEM

Press Release. Friction Stir Welding: Grenzebach extends its portfolio


RH800 & 2000 BASIC OPERATIONS

The Criticality of Cooling

Your local gas generation partner. Precision series Modular gas generation solution for GC.

FACT SHEET 1. Compressed Air System Selection and Efficient Production. How to save energy, reduce costs and help the environment

Project Title: Pneumatic Exercise Machine

Pneumatic high-pressure controller Model CPC7000

Universal Valve Company Inc

Integrating Aeration Blowers with Most-Open-Valve

Universal Valve Company Inc

EasyTouch. Because automation makes it all so simple. Pool and Spa Control Systems. By Pentair Water Pool and Spa

CONTROL PANEL OPERATING MANUAL. AIR COOLED SCREW CHILLER GLOBAL DESIGN Software version ASDU01C and later D-EOMCP EN

X-Flow Mass Flow Controller 授权代理 : 北京品超思瑞科技学院公司

PART 5 - OPTIONS CONTENTS 5.1 SYSTEM EXPANSION 5-3

INSTRUCTION MANUAL STATION CONTROLLER SC100 MOTOR PROTECTION ELECTRONICS, INC.

Modelling Today for the Future. Advanced Modelling Control Techniques

7250 Sys. Ruska Multi-Range Pressure Calibration System. GE Sensing & Inspection Technologies. Features. Applications

SULLAIR SX Filtration Series ,000 scfm

LT GasAnalyzer. LT GasAnalyzer Page 1 of 6

Transcription:

Net$ync II Net$ync II System Controllers

Net$ync II Conductor System System Optimization The Quincy Net$ync II Conductor system selects the most efficient combination of compressors based on demand. Consistent, steady pressure will optimize production and minimize power costs. Save 20% to 60% in Energy Costs Synchronizing compressed air output with demand ensures the system will never operate more compressors or use more electricity than is required. Net$ync II Conductor-12 Universally Deployable The Net$ync II Conductor system can be used with almost any combination of compressors regardless of make or local control type. It provides a main control Conductor to direct the machine-specific interface modules. The interface modules are individually dedicated to operate stop/start, fixed speed, variable capacity and VSD compressors. The more complex the system, the greater the energy savings potential. Selectable Pressure Bands, Machine Priorities and Modes Advanced algorithms allow the operator to customize operating protocols for optimum performance and efficiency. Reduced System Maintenance Running only those compressors required to satisfy demand will minimize the total running hours of all compressors and reduce the load on downstream dryers and filters. Reduced running time and lighter loads also translate into reduced maintenance. Power$ync I/O Gateway Optional Remote Monitoring Software and Expanded I/O Monitor your entire system performance from your desktop. Adding inputs, such as filter pressure drop or dewpoint allows you to keep a close watch on your process. Q485 Gateway

Adjustable Pressure Band This feature allows the operator to program scheduled changes to pressure operating targets to optimize energy savings. For example, an operator may select one target pressure for Monday through Friday and a lower pressure target for Saturday and Sunday operation, thus reducing energy costs. Selectable Machine Priorities Net$ync II allows users to select the priority of multiple machine operation in order to optimize energy savings, reduce maintenance and ensure consistent system pressure. For example, priorities can be established so that newer equipment operates first and older, backup machines turn on with last priority. Net$ync II Conductor 12, 24 and VAC also include the advanced energy algorithm to automatically select the most efficient combination of compressors to satisfy the system demand. Mode Selection To further customize a multiple compressor system, the Quincy Net$ync II Conductor system provides four operating modes: Energy Control Mode - Uses the advanced energy control algorithm to automatically select the most efficient combination of machines. If there is a VSD compressor in the network, it will typically be the lead machine. EHR - Equalizes running time on all compressors in the network. This helps synchronize maintenance cycles and prevents overworking older machines. FIFO - (First in, First out) This is the mode used for Stop/ Start controls and reciprocating compressors. (Conductor -4 models only). FILO - (First in, Last out) For fixed and variable capacity rotary compressors. Simple timer rotation machine selection. Conductor VAC Conductor 24 Conductor 12 Conductor 4 From systems small to large, the Quincy Net$ync II family provides an energy efficient solution. Operating your compressed air system at pressures above your minimum desired level results in wasted energy costs. Quincy s Net$ync II ensures your system operates at your optimal pressure; ensuring production consistency without excessive energy costs.

Net$ync II Conductor System Compressor Management Multiple compressor networks have always been difficult to control due to such variables as fluctuating demand, pressure switch repeatability, air treatment requirements, overall system design and piping layout. Typically, multiple compressor systems use a cascade method to maintain required pressure. In order for the trim machines to load on falling pressure, the cascade method requires the system to operate at higher pressures all of the time. A three-unit system might require a 20 psi pressure band to maintain system pressure. Unnecessarily high system pressure equals wasted energy in a compressor cascade system. Quincy s Net$ync II Conductor system manages compressor operation in a very tight pressure band, eliminating energy wasting effects of artificial load caused by unnecessary elevated pressure. A typical Net$ync II Conductor system with three 100 HP compressors networked could save more than $10,000 annually versus a cascade system. For every two psi that the system operates above the minimum required pressure, 1% of compressor energy is wasted. With the Net$ync II Conductor system, this waste is minimized. Before Net$ync II Conductor System Operating Pressure Compressor A Compressor B Compressor C 115 110 105 Unload 100 Unload 95 Unload Load 90 Load 85 Load 80 Minimum Plant Pressure * Based on a three compressor cascade system at a 10 psi pressure range *Based on 8,750 hrs/yr at $0.10/kwh electrical costs After Net$ync II Conductor System Operating Pressure Compressor A Compressor B Compressor C 115 110 105 100 Tight Pressure control through Intelligent System Management 95 90 Unload Unload Unload 85 Load Load Load 80 Minimum Plant Pressure * Based on a three compressor cascade system at a 10 psi pressure range *Based on 8,750 hrs/yr at $0.10/kwh electrical costs

Net$ync II Family of System Controllers Conductor - 4: Central management and control of networks consisting of two, three and four compressors. Compatible with fixed-speed compressors only. Includes FIFO control algorithm. Conductor - 12: Central management and control of networks consisting of two to twelve compressors, including multiple VSD installations. Includes energy optimizer algorithm. Conductor - 24: Central management and control of networks consisting of two to twenty-four compressors, including multiple VSD installations and installations with multiple compressor rooms. Includes energy optimizer algorithm. All Net$ync II conductors and gateways feature back-lit user interfaces which are both informative and intuitive. Conductor - Vac: Central management and control of vacuum pump networks consisting of two to twelve vacuum pumps. Includes energy optimizer algorithm. All Net$ync II Conductor models ensure a narrow pressure band using enhanced software. The pre-programmed software application can be customized and/or expanded, on site, using the passwordprotected operator interface. System Flow Schematic Typical Three Compressor Network QGV-75 quincycompressor.com VSD Gateway VSD Compressor QSI-500i quincycompressor.com Pressure Transducer Dewpoint Power$ync Gateway Power$ync Compressor QGD-30 quincycompressor.com Wet Receiver CPN Filter Delta P Air Dryer Dryer Status (on/off) Dry Receiver Q485 Gateway Fixed Speed Compressor I/O Gateway Net$ync II

Ancillary Equipment Monitoring & Control I/O Gateway Customize a system by monitoring downstream equipment Automatic operating of ancillary equipment e.g. water pumps 8 Digital inputs 4 Analog inputs 16 Virtual Relay outputs (6 physical) Net$ync II Sensors System Pressure Δ P across filters, dryers and receivers System Temperature System Dewpoint System Flow Compressor Current Quincy System Monitoring (QSM) is independent of remote servers or other IT infrastructure hardware, allowing users to create their own dedicated data tunnel, freely and easily accessing information from wherever they will be in the world. QSM provides unrivaled access to system information through its intuitive HTML and Java screens. QSM provides such a thorough and detailed system analysis, it s like having a permanent audit! * Modular and expandable, Net$ync II can answer tomorrow s needs today. Choose Your Net$ync II Conductor Function Conductor-4 Conductor-12 Conductor-24 Conductor-VAC Max. Number of Compressors 4 12 24 12* Max. Number of Programmable Profiles 3 4 6 4 Single, Tight Pressure Band Control x x x x Real Time Clock Scheduling x x x x Programmable System Pre-fill x x x x Energy Optimizer Algorithm x x x Multiple VSD Control x x Ancillary Equipment Starting x Multi-zone Control x Multi-pressure Balance x Back-up Pressure Transducer Capable x Visualization of I/O Gateways 2 2 12 2 *Vacuum Pumps

Quality Comes in All Shapes and Sizes But Just One Color. Quincy Has The Compressed Air Solution for Your Application. Since 1920, Quincy s trademark blue compressors have been hard at work building our company s reputation for quality and performance in the world s most demanding applications and harshest environments. Our Promise to You. As a customer, you can always count on Quincy for a low cost of ownership through stable air pressure, easy maintenance and longer equipment life. And we back it all with one of the strongest warranties in the industry. No shortcuts and no substitutions that s the quality of Quincy. We re Still Making History. Today, you ll find that same leadership in Quincy s next-generation compressed air solutions that feature everything from smart controls to green technologies. We know that your company is counting on our reputation, that s why every Quincy product is designed, constructed and proven to deliver exceptional customer value before it is worthy of wearing the Quincy name.

Performance You Demand. Reliability You Trust. TM 701 N. Dobson Avenue Bay Minette, AL 36507 Phone 251.937.5900 Fax 251.937.0872 Email: info@quincycompressor.com QuincyCompressor.com 2016 Quincy Compressor. All rights reserved. Printed in U.S.A. (Net$ync (QR25-010 11-001 01/17) 06/16)