BLOCK II HYDROGENATION (COMPRESSORS) OUTSIDE LOGSHEETS C-200A TIME: NORM COND PSV SET DIVIDER BLOCK (DB) RESERVOIR LEVEL

Similar documents
Operating Instructions

ATL R/V Atlantis AUXILIARY PLANT OPERATION APPENDIX OPERATING PROCEDURES

Water Mist Systems Inspection, Testing, and Maintenance of Water Mist Systems

COURSE MAPPING RATINGS FORMING PART OF ENGINEERING WATCH

AcornVac Vacuum Plumbing Systems - Trouble Shooting Guide

STREAMLINE SHOP SERIES MODEL 30040V OPERATION & PARTS MANUAL

Operating Instructions Models 36200, , 46200, Hydrostatic Test Pumps

HYDROGEN UNIT CHAPTER-4 UTILITY SYSTEM DESCRIPTIION

CO 2. (R744) Service Station Presentation. Contents. Goals Basic functions Specification Recovery R477 Vacuum Charge Safety Other features Prototype

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

Swimming Pool Plans and Specification Report

GAS COMPRESSION SYSTEM

Successful Implementation of Dry Gas Seal in High Pressure Recycle gas Compressor at Hydrocracker & Effect of Gas composition on DGS Performance

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

Proper Pump Installation Practices

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION

Improve Reliability of Turbomachinery Lubrication and Sealing Systems

Steam System Best Practices 14 Best Practices for Guide Lines for Boiler Plant Log Books

Operating Instructions Models and Hydrostatic Test Pumps

Operating Instructions Models and Hydrostatic Test Pumps

Steam Locomotive Operating Procedures SVLS Locomotive 1973 Steam Up

KJ4000 Operating Instructions & Parts Manual NSN

Inert Air (N2) Systems Manual

Product Sheet Spraymist Unit

Gas Absorption Draft Standard Operating Procedure

Bulletin TCR-104 & 109 Filling and adding to the Glycol pressure system

LAKOS Waterworks. PWC Series Sand Separators. Installation & Operation Manual LS-829 (10/12)

Owner's Manual Sealweld SuperSeal II Pump

SpectraPure PUMPED RO SYSTEMS (PSP) User s Manual for PSP-1500 Systems

LGSS Liquefied Gas & VSS Vapor (Gas) LGSS VSS LGSS. Features and Benefits

Hill PHOENIX Second Nature Medium Temperature Secondary Refrigeration Start-Up Guide

Air Operated Hydraulic Pumping Systems to 50,000 psi

BIMA cryogenics (Dick Plambeck, 18jan2007)

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

STREAMLINE SHOP SERIES MODEL OPERATION & PARTS MANUAL

OWNER S TECHNICAL MANUAL

REFRIGERATION SYSTEM COMPONENTS

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

Dry Gas Seal Rack CH-3185 Schmitten Tel Mail:

ECS Protector Nitrogen Generator PGEN-30 (PGEN-30E)

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL

IMPORTANT SAFETY INSTRUCTIONS

1 Exam Prep NSF/ANSI Tabs and Highlights

2 I All-Flo Pump Co.

Part IV: Troubleshooting

1 Exam Prep NFPA 99 Health Care Facilities Questions and Answers (Plumbing Contractor)

Office Use Only Fee Paid

CENTRAL PLANT HEATING/CHILLED WATER OPERATOR Ref. Code: C-WO-4

TECHNICAL DATA. Q = C v P S

hydro-pac, inc. Low-Pressure Gas Compressors 1500 to 6000 PSI

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

SF SERIES CNG COMPRESSOR MODEL HF-4MH. 4 Nm3/Hour Displacement OPERATION MANUAL

200 PSI COMPRESSORS - MODEL NUMBERS

Annual Inspection and Calibration Checklist VAF Oilcon MK-6(M) MEPC.108(49) Page 1 of 5

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

Technical Service Bulletin March 2015 TSB142.01

Lab Assessments Workshop

NORMAL OPERATING PROCEDURES Operating Parameter Information

INSTALLATION AND OPERATION MANUAL CHEMICAL BYPASS FEEDER General Instructions Regarding All Models

WORCESTER COUNTY HEALTH DEPARTMENT PRE-OPENING GUIDE SEMI PUBLIC POOLS 1. POOL WALLS AND BOTTOM SMOOTH, LIGHT COLORED AND EASILY CLEANABLE. (.

Code AWC20HP Air Compressor

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

Equipment Operating Procedure Glove Box

FOAM TANK (1/2) DATA SHEET

Operating Instructions Model and Hydrostatic Test Pump

1 HP / 1.6 GALLON AIR COMPRESSOR OPERATING MANUAL

WAKE COUNTY POOL PERMIT PRE-SEASON AUDIT 2014

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N

Manual. Bypass Feeder. Installation Maintenance Repair Manual. Chemical Addition and Filtering

Installation Manual. Model # SF-3W 9/16/03 REV 1. Arch Chemicals, Inc Lower River Road. P.O. Box 800 Charleston, TN PULSAR

Operating Instructions Models and Hydrostatic Test Pumps

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

DRAFT. Operating Procedures for the NPDGamma Liquid Hydrogen Target in TA-53, Building MPF-35

100C Air Compressor Kit

In addition to this SOP, the policies and procedures of each operating company will be strictly observed by Rockwater personnel.

Copyright, 2005 GPM Hydraulic Consulting, Inc.

Introduction. Part one: Identify the Hydraulic Trainer Components

Mechanical Seal Piping Plans

Installation, Operation, and Maintenance Manual

OPERATION MANUAL NTF-15

WORCESTER COUNTY HEALTH DEPARTMENT PRE-OPENING GUIDE RECREATIONAL POOLS 2. DECK AND COPING MUST BE IN GOOD REPAIR AND PROPERLY DRAINED. (.

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

Simplified Start-Up Checklist For Fully-Pressurized Seasonal Systems

Standard Operating and Maintenance Instructions for Pumping System Model PS-150

CLEARWATER SERIES REVERSE OSMOSIS DESALINATOR INSTALLATION & OPERATION MANUAL

OPERATION MANUAL NTF-60 Plus

Installation and Instructions 2. Product Features 3-6. Key Pad Functions 7. Distributor Information Programming Guide 8. Master Programming Guide 9-14

2 I All-Flo Pump Co.

High Performance Oilless Commercial Refrigerant Recovery Unit. User Manual

STAINLESS STEEL GRAND SERIES

Models: C62/63/64-A/D

R E D I C O N T R O L S

Instructions for SILEX 1C Mixed bed cartridge filter

MANUAL BE SERIES Test Benches

FE Petro vs. New Red Jacket Competitive Comparison

High Performance Oilless Commercial Refrigerant Recovery Unit. User Manual Rev. 4 November 2010

Hydrogen Cooling System

Transcription:

BLOCK II HYDROGENATION (COMORS) DATE: C-200A DIVIDER BLOCK (DB) RESERVOIR TIME: NORM SET DB RESERVOIR TEMP (Range 80-105ºF) DB PROFLOW DISPLAY (ALARM OR NORMAL?) DB NEOMAG INDICATORS (CYCLING?) DB PIN INDICATORS (ANY POPPED OUT?) DB POPR VALVE (RED BAND SHOWING?) CRANKCASE URE (FILTER) URE (BEARINGS) 1 ST STAGE CYLINDER WATER 1 ST STAGE SUCTION URE 0.23 0.69 1 ST STAGE DISCHARGE TEMP. 2 ND STAGE CYLINDER WATER 2 ND STAGE SUCTION URE 2.6 3.4 2 ND STAGE DISCHARGE TEMP. 2 ND STAGE SUCTION TEMP. DISCHARGE SUCTION = 125 A1 KO DRUM 3 RD STAGE CYLINDER WATER 3 RD STAGE SUCTION URE 8.8 11.0 3 RD STAGE DISCHARGE TEMP. 3 RD STAGE SUCTION TEMP. DISCHARGE SUCTION = 11.5 A2 KO DRUM 4 TH STAGE CYLINDER WATER 4 TH STAGE SUCTION URE 27 34.5 4 TH STAGE DISCHARGE TEMP. 4 TH STAGE SUCTION TEMP. DISCHARGE SUCTION = 120 3 KO DRUM 5 TH STAGE CYLINDER WATER 5 TH STAGE SUCTION URE 76 88.0 5 TH STAGE DISCHARGE TEMP. 5 TH STAGE SUCTION TEMP. DISCHARGE SUCTION = 95 A4 KO DRUM DAY OPERATOR: DAY SUPERVISOR: NIGHT OPERATOR: NIGHT SUPERVISOR: PAGE 1 OF 15

BLOCK II HYDROGENATION (COMORS) C-200A (CONTINUED) TIME: NORM SET 6 TH STAGE PACKING WATER 6 TH STAGE SUCTION URE 163 193 6 TH STAGE DISCHARGE TEMP. 6 TH STAGE SUCTION TEMP. DISCHARGE SUCTION = 80 A5 KO DRUM CLOSED COOLING WATER TEMP. COOLING WATER URE D-16 DRAIN in D-205 PAGE 2 OF 15

BLOCK II HYDROGENATION (COMORS) C-209 DIVIDER BLOCK (DB) RESERVOIR TIME: NORM SET DB RESERVOIR TEMP (Range 80-105ºF) DB PROFLOW DISPLAY (ALARM OR NORMAL?) DB NEOMAG INDICATORS (CYCLING?) DB PIN INDICATORS (ANY POPPED OUT?) DB POPR VALVE (RED BAND SHOWING?) CRANKCASE URE (FILTER) URE (BEARINGS) 1 ST STAGE CYLINDER WATER 1 ST STAGE CYLINDER WATER 1 ST STAGE SUCTION TEMP. (TE209-1) D-209 SEPERATOR 2 ND STAGE SUCTION URE 2 ND STAGE CYLINDER WATER 2 ND STAGE CYLINDER WATER 2 ND STAGE SUCTION TEMP. (TE209-14) S-209-1 SEPERATOR 3 RD STAGE CYLINDER WATER 3 RD STAGE SUCTION URE 3 RD SUCTION TEMP. TE-209-19 S-209-2 3 RD STAGE DISCHARGE URE PAGE 3 OF 15

BLOCK II HYDROGENATION (COMORS) C-201A DIVIDER BLOCK (DB) RESERVOIR TIME: NORM SET DB RESERVOIR TEMP (Range 80-105ºF) DB PROFLOW DISPLAY (ALARM OR NORMAL?) DB NEOMAG INDICATORS (CYCLING?) DB PIN INDICATORS (ANY POPPED OUT?) DB POPR VALVE (RED BAND SHOWING?) CRANKCASE 1 ST STAGE CYLINDER WATER OUTLET TEMP. 2 ND STAGE CYLINDER WATER OUTLET TEMP. 3 RD STAGE CYLINDER WATER OUTLET TEMP. 4 TH STAGE CYLINDER WATER OUTLET TEMP. D-203B S-201B-1 S-201B-2 S-201B-3 D-204B DISCHRGE SEP. 1 ST STAGE DISCHARGE TEMP. 1 ST STAGE SUCTION TEMP. DISCHARGE SUCTION = 65 2 ND STAGE DISCHARGE TEMP. 2 ND STAGE SUCTION TEMP. DISCHARGE SUCTION = 65 3 RD STAGE DISCHARGE TEMP. 3 RD STAGE SUCTION TEMP. DISCHARGE SUCTION = 45 4 TH STAGE DISCHARGE TEMP. 4 TH STAGE SUCTION TEMP. DISCHARGE SUCTION = 35 OUTBOARD BEARING TEMP. PAGE 4 OF 15

BLOCK II HYDROGENATION (COMORS) C-201A (CONTINUED) TIME: NORM 1 ST STAGE SUCTION URE 22 27 1 ST STAGE DISCHARGE URE 2 ND STAGE SUCTION URE 48 55 2 ND STAGE DISCHARGE URE 3 RD STAGE SUCTION URE 104 121 3 RD STAGE DISCHARGE URE 4 TH STAGE SUCTION URE 178 207 4 TH STAGE DISCHARGE URE. SET PAGE 5 OF 15

BLOCK II HYDROGENATION (COMORS) C-201B TIME: DIVIDER BLOCK (DB) RESERVOIR DB RESERVOIR TEMP (Range 80-105ºF) DB PROFLOW DISPLAY (ALARM OR NORMAL?) DB NEOMAG INDICATORS (CYCLING?) DB PIN INDICATORS (ANY POPPED OUT?) NORM SET DB POPR VALVE (RED BAND SHOWING?) CRANKCASE 1 ST STAGE CYLINDER WATER OUTLET TEMP. 2 ND STAGE CYLINDER WATER OUTLET TEMP. 3 RD STAGE CYLINDER WATER OUTLET TEMP. 4 TH STAGE CYLINDER WATER OUTLET TEMP. D-203B S-201B-1 S-201B-2 S-201B-3 D-204B DISCHRGE SEP. 1 ST STAGE DISCHARGE TEMP. 1 ST STAGE SUCTION TEMP. DISCHARGE SUCTION = 78 2 ND STAGE DISCHARGE TEMP. 2 ND STAGE SUCTION TEMP. DISCHARGE SUCTION = 72 3 RD STAGE DISCHARGE TEMP. 3 RD STAGE SUCTION TEMP. DISCHARGE SUCTION = 45 4 TH STAGE DISCHARGE TEMP. 4 TH STAGE SUCTION TEMP. DISCHARGE SUCTION = 21 OUTBOARD BEARING TEMP. PAGE 6 OF 15

BLOCK II HYDROGENATION (COMORS) C201B (CONTINUED) TIME: NORM 1 ST STAGE SUCTION URE 20 27 1 ST STAGE DISCHARGE URE 2 ND STAGE SUCTION URE 50 59 2 ND STAGE DISCHARGE URE 3 RD STAGE SUCTION URE 112 132 3 RD STAGE DISCHARGE URE 4 TH STAGE SUCTION URE 205 227 4 TH STAGE DISCHARGE URE SET PAGE 7 OF 15

BLOCK II HYDROGENATION (COMORS) C-206 RUNNING A OR B D-206 AT200 OVER-URE (CHECK GAUGE, SHOULD READ 0 PSI)* C-206 RESEVOIR C-206 CRANKCASE F, ¾, ½, ¼ C-206 DISCHARGE TEMP. C-206 DISCHARGE URE C-206 SUCTION URE DISCHARGE URE SUCTION URE PACKING LEAKS, KNOCKING Y / N DIVIDER BLOCK (DB) RESERVOIR DB RESERVOIR TEMP (Range 80-105ºF) DB PROFLOW DISPLAY (ALARM OR NORMAL?) DB NEOMAG INDICATORS (CYCLING?) DB PIN INDICATORS (ANY POPPED OUT?) DB POPR VALVE (RED BAND SHOWING?) TIME: *CONTACT INSTRUMENT ANALYZER GROUP (7720) IF GAUGE INDICATES OTHER THAN 0 PSI. CHECK OFF EACH SHIFT WHEN COMPLETED DAYS NIGHTS BLOWDOWN F-206 / D-207 PURGE CRANKCASE C-206 AMP DRAW NORMAL: 40 TO 60, MAX 67 AMPS SUBSTATION #2 CHECK TIME: MP-1 AMP METER PANEL IS IN #4 SWITCHGEAR ROOM - N/E CORNER OF EAST ROOM 0700 0700 HEATER AMP METER EQUIPMENT STATUS HEATER AMPS* (RUNNING / DOWN) C-200A (MP-1 AMP METER PANEL) C-209 (MP-1 AMP METER PANEL) C-206A (MP-1 AMP METER PANEL) C-206B (MP-1 AMP METER PANEL) C-201A (MP-1 AMP METER PANEL) C-201B (METER ON SWITCHGEAR) P-205A (MP-1 AMP METER PANEL) P-205B (METER ON SWITCHGEAR) P-207 (MP-1 AMP METER PANEL) * WHEN EQUIPMENT IS RUNNING, HEATER AMP SHOULD BE ZERO. WHEN EQUIPMENT IS DOWN, HEATER AMP SHOULD BE AT LEAST 3 10 AMPS. ANY DISCREPANCIES, NOTIFY SUPERVISOR. PAGE 8 OF 15

BLOCK II HYDROGENATION (COMORS) D-202 IS THE TOP LAYER (SOLID WHITE) IN D-202 OUTSIDE THE DRAIN MARKERS? Y / N Y / N CHECK TO SEE THAT / AIR INTERFACE IS VISABLE IN SIGHT GLASS. CHECK WATER SEAL LOOP FOR RESTRICTION IF NOT VISABLE. OK? Y / N OK? Y / N D-202 TOP LAYER DRAINED TO DRUM? Y / N Y / N D-202 CHECK: IF TOP OF SOLID WHITE LAYER IS ABOVE THE TOP MARKER OR THE BOTTOM OF THIS LAYER IS BELOW THE BOTTOM MARKER, DRAIN INTO AN EMPTY 55 GALLON WASTE DRUM. IF THE TOP STARTING IS BELOW THE OVERFILL LINE, ALL OF THE ABOVE THE DRAIN VALVE WILL FIT INTO AN EMPTY 55 GALLON DRUM. DUE TO A LARGE RAG LAYER BETWEEN THE AND WATER LAYERS, GOOD JUDGMENT WILL HAVE TO BE USED TO DETERMINE WHEN TO DRAIN FROM D-202. ONCE PER SHIFT (MUST CLIMB UP) DAYS NIGHTS E-261 PI Red Indicator (Tattletale) Inlet (near exchanger) Outlet (off south side platform) ONCE PER SHIFT E-206 E-210 E-220 E-240 E-241 E-250 E-260 E-270 (MUST CLIMB UP) A B A B A B A B A B C D A B C D DAYS NIGHTS P-240A/B P-211 P-221 P-251 P-261 P-271 TIME SEAL P-240A/B GOING DIF TO: (CIRCLE ONE) D-200 D-300 DAYS TIME TIME 240 0 060 0 120 0 180 0 DIF IS THE N2 CRANKCASE PURGE LINED UP TO BYD FEED PUMP? (Y/N) (SHOULD BE YES UNLESS TAGGED OUT) DIF DIF DIF P204A P204B P205A P205B P207 * All feed pump lubricators will need to be checked every 6 hours until further notice. Adjust oiler as needed to achieve approximately 30 drops per minute. GYROL S GEAR BOX DISCH CRANK CASE P-204A P-204B *P-205A* DISCH Reser voir Oil Level ProFlo Device Alarm? Oil Tem p GYROL GEAR BOX CRANK CASE DISCH *ER CHECK 30 30 30 GYROL GEAR BOX CRANK CASE DISCH P-205B *P-207* E-231B E-232 F-260 F-270 *ER CHECK 30 30 30 S DISCH HEAD TANK 295 299 258 268 232 *ER LUBE FILTERS CHECK A B 30 30 30 30 30 Inlet Outlet Inlet Outlet 253 *55 GAL DRUM TIME (%) (BAR) (BAR) (BAR) (BAR) (BAR) (BAR) (%) Turn on the oil skimmer if the catalyst sump is dirty. * Change the oil drum if full. 26007 (BAR) STEAM BAR STEAM BAR IN BAR OUT BAR IN BAR *ER CHECK 30 30 30 OUT BAR P212A P212B P212C P212D P212E P212F (%) (%) (%) (%) (%) (%) PAGE 9 OF 15

ERS CHECK: IF ER DRIP GLASS IS FULL, LOOSEN VENT CAP TO DROP, THEN RETIGHTEN CAP. IF DROPS ARE NOT DRIPPING OR THE WON T PULL DOWN WITH CAP LOOSENED, THEN THE LUBRICATOR ISN T PUMPING, TELL YOUR SUPERVISOR. IF THE COMOR ISN T RUNNING, TURN OFF THE LUBRICATOR. REMARKS: PAGE 10 OF 15

BLOCK II GBL I OUTSIDE LOGSHEET ONE FULL ROUND OF READINGS MUST BE TAKEN ONCE PER SHIFT. IF BUSY AT TIME OF FIRST ROUND, TAKE THE FULL ROUND LATER AND NOTE TIME TAKEN. SHADED AREAS HAVE TO BE TAKEN ONLY ON SPECIAL REQUEST. VERIFY URE ON T7 TRANSFORMER IS READING 1.5 3 psi TRANSFORMER HAS CRACK IN SEAL AND MUST BE MONITORED UNITL REPAIRS NEED TO BE COMPLETED. IF URE FALLS BELOW 1.5 psi NOTIFY SUPERVISOR AND OE IMMEDIATELY. URE GAUGE MEDIA PANEL MEDIA TEMP PANEL STACK TEMP PANEL FLAME INTENSITY PANEL D. P. CONTROL INLET TEMP. GAUGE T7 Transformer 1.5 3 psi See note above TIME PSI C C PSI c psi TIME D-055 HOT VENT D-055 URE SKIMMER SKIMMER DRUM FT. (FT.) BAR ON / OFF TIME P-055AX COOLING WATER INLET URE P-055AX COOLING WATER OUTLET URE P-055B COOLING WATER INLET URE P-055B COOLING WATER OUTLET URE P-055AX BEARING INDICATOR P-055BX BEARING INDICATOR P-055 DISCH. P-055 RUNNING (BAR) (BAR) (BAR) (BAR) (OK / RED) (OK / RED) (BAR) (A/B/AX/BX) TIME *P-056* *P-055A* *P-055B* Leaking Leaking Leaking Y/N Y/N Y/N *NOTE: If a leak is found on a regulated pump/agitator or non- regulated pumps/equipment, the leak MUST be reported to the supervisor and a leak notification entered before the end of the shift. PAGE 11 OF 15

BLOCK II GBL I OUTSIDE LOGSHEET P-521 P-512 P-501 P-522 P-510 D-526 VP-526 SUCT. TIME (BAR) (BAR) (BAR) (BAR) (BAR) (FT.) IN. HG. VAC SUMP FI-578 N 2 PURGE TO H 2 VENT STACK TIME (PSI) MAINTAIN 7 SCFM FI-579 N 2 PURGE TO H 2 VENT STACK MAINTAIN 7 SCFM D-501 SEAL LOOP (FT.) TIME E-505 SIGHT GLASS E-522 FAN E-504 FAN GBL PRODUCT TEMP MULTI- COOLER FAN C-551 Ring H2O C-551 Seal Flush OPEN ON /OK ( C) ON /OK 6-10 GPM 0.5 GPM TIME P-821 BEARING MONITOR P-822 BEARING MONITOR P-801 BEARING MONITOR P-812 BEARING MONITOR P-810 BEARING MONITOR D-807 FILTER DP SUMP CHECK C-800 Snubber Record Quantity C-800 Oil Added R-800. SIGHT GLASS TIME (FT) (PSI) (IN H 2 O) Quantity Drained? Quantity (EMPTY) Gal. Gal. Gal. Gal. E-507 SIGHT GLASS MULTI- COOLER FAN E-803 SIGHT GLASS E-800 SIGHT GLASS D-804 SIGHT GLASS E-804 FAN TIME (OPEN) (ON / OK) (OPEN) (OPEN) (OPEN) (ON / OK) *NOTE: If a leak is found on a regulated pump/agitator or non- regulated pumps/equipment, the leak MUST be reported to the supervisor and a leak notification entered before the end of the shift. PAGE 12 OF 15

BLOCK II NMP OUTSIDE LOGSHEET E-632 FAN. FI610 T620 BTMS TO E612 FI611 T620BTMS TO T612 T-620 350# STEAM E-602 CHEST TIME (ON /OK) (GPM) (GPM) (FT) (BAR) (BAR) * Note: Radio Control Room for current target flows on FI610 & FI611 TIME P-634 (BAR) P-632 VP-633 SUCT. P-631 P-612 P-635 P-635 BEARING MONITOR P-622 P-601 TIME (BAR) IN HG VAC. (BAR) (BAR) (BAR) (BAR) OK P-601A/B/C SUCT. P-601A/B/C DISCH. P-602 P-602A/B/C SUCT. P-602A/B/C DISCH. TIME (BAR) (BAR) OK (BAR) (BAR) *NOTE: If a leak is found on a regulated pump/agitator or non- regulated pumps/equipment, the leak MUST be reported to the supervisor and a leak notification entered before the end of the shift. PAGE 13 OF 15

BLOCK II GBL I / GBL II / NMP OSBL OUTSIDE LOGSHEET P-698 URE D-698 TEMPERATURE P-590 URE P-692 URE P-690 URE P-899 URE TIME (BAR) ( C) (BAR) (BAR) (BAR) (BAR) P-890A URE P-890B URE P-599 URE P-591 A/B URE P-699 URE TIME (BAR) (BAR) (BAR) (BAR) (BAR) D-695 URE D-695 RUPTURE DISC. FI94101 N 2 ROTOMETER TO FLARE TOP OF D-695 TIME (BAR) URE MAINTAIN 7 SCFM D-695 TEMPERATURE ( C) P-500 URE (BAR) P-696 TIME URE BEARING INDICATOR NMP ULTRA SKID DRAIN VALVE NMP ULTRA PIPING LEAKS P-696 SUMP EMPTY P-361A/B URE MMA IN COOLING TOWER WATER (OPEN) (YES / NO) (YES / NO) (BAR) (PPM) NMP ULTRA SKID DRAIN VALVE SHOULD NORMALLY BE OPEN. CONTACT YOUR SHIFT SUPERVISOR IF THE VALVE IS CLOSED OR IF THERE ARE ANY LEAKS ON PIPING. *NOTE: If a leak is found on a regulated pump/agitator or non- regulated pumps/equipment, the leak MUST be reported to the supervisor and a leak notification entered before the end of the shift. PAGE 14 OF 15

BLOCK II COOLING TOWER ph RETURN LINE LAB VERIFY NO DEFICIENCIES IN ITION OF COOLING TOWER HANDRAILS & PLATFORM UCTIVITY, LAB (1500 MAX) CHLORINE, PPM (0.3 0.7) HYPOCHLORIDE PUMP STROKES CALCIUM, PPM (250 350 PPM) IRON, PPM ORTHO PO 4 (4 7 PPM) FILTERED PUMP SETTING 20K / CTP-42 TIMER SETTING 20K 20K / CTP-42 DRAW DOWN, INSIDE DAY TANK SUPPLY URE A SUPPLY URE B SUPPLY URE C SUPPLY / RETURN TEMPERATURE ( C) EXPLOSION METER CHECK OK DELUGE SYSTEM ARMED COOLWELL (%) COOLING TOWER PUMP SCREENS FAN CHECK: MOTOR TEMPERATURE OK MINIMAL VIBRATION GEAR BOX OK PUMP CHECK: GENERAL ITION NO SEAL LEAKS HYPOCHLORITE (07:00 only) * NOTE: IF TANK IS < 30%, CALL ELINDA TAILLON AT EXT. 7931 TO INITIATE AN ORDER. TIME: 07:00 19:00 *NOTE: If a leak is found on a regulated pump/agitator or non- regulated pumps/equipment, the leak MUST be reported to the supervisor and a leak notification entered before the end of the shift. PAGE 15 OF 15

BLOCK II TANK FARM DIKE VALVES OUTSIDE LOGSHEET DAY SHIFT DIKE VALVE BY D-691 #4 CLOSED ( ) DIKE VALVE BY D-698 #5 CLOSED ( ) DIKE VALVE BY D-055 #6 CLOSED ( ) OPEN @ TIME OPEN @ TIME OPEN @ TIME TOC PPM* TOC PPM* TOC PPM* OPERATOR: OPERATOR: OPERATOR: DIKE VALVE NORTHWEST OF BETZ TANKS #15 CLOSED ( ) OPEN @ TIME TOC PPM* OPERATOR: NIGHT SHIFT DIKE VALVE BY D-691 #4 CLOSED ( ) DIKE VALVE BY D-698 #5 CLOSED ( ) DIKE VALVE BY D-055 #6 CLOSED ( ) OPEN @ TIME OPEN @ TIME OPEN @ TIME TOC PPM* TOC PPM* TOC PPM* OPERATOR: OPERATOR: OPERATOR: DIKE VALVE NORTHWEST OF BETZ TANKS #15 CLOSED ( ) OPEN @ TIME TOC PPM* OPERATOR: REPORT TO SUPERVISION IF TOC s ARE MORE THAN 100 PPM FOR PERMISSION TO OPEN DIKE VALVE COMMENTS: *NOTE: If a leak is found on a regulated pump/agitator or non- regulated pumps/equipment, the leak MUST be reported to the supervisor and a leak notification entered before the end of the shift. PAGE 16 OF 15