ECS Protector Nitrogen Generator PGEN-30 (PGEN-30E)

Similar documents
ECS Protector Nitrogen Inerting Vent (PAV-WN)

NGP-250/500 Nitrogen Generator Quick Start Guide

South-Tek Systems - Nitrogen Generation Corrosion Inhibiting System. Designed for: Dry or Preaction Fire Protection Systems (FPS)

Type 3 - PSA Nitrogen Generation System

Potter Nitrogen Generators

Type 1 - Nitrogen Generation System. Designed for: Dry or Pre-Action Fire Protection Systems (FPS) with a total capacity up to 750 gallons

CORROSION AT THE AIR-WATER INTERFACE REMOVE THE GAS

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

Technical Information

TECHNICAL DATA OBSOLETE

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

Installation, Operation, and Maintenance Manual Parker Balston Model N2-04 Nitrogen Generator

Nitrogen Advantage. Better Tire Pressure Retention. Improved Fuel Economy. Extended Tread Life. Elimination of Oxidation. Reduction in Tire Failures

TECHNICAL DATA. Trimpac 244a. September 16, 2013

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL

Workhorse-15 Oxygen Generator

OPERATION MANUAL NTF-15

TECHNICAL INFORMATION

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH PNEUMATIC RELEASE

Inert Air (N2) Systems Manual

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

N2 BLAST Datasheet Preaction single interlock electric c/w N 2 Blast Nitrogen generating system Remote controlled unit

Workhorse 8 Oxygen System Model No 5665, 5673, 5679

Data Sheet Issue A

LPS Product Guide. LPS Series Nitrogen Generators. N2-GEN LPS TM - Layup Protection System Copyrighted All Rights Reserved

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

OPERATION MANUAL NTF-60 Plus

TECHNICAL DATA. Trimpac 257a. September 16, 2013

TECHNICAL INFORMATION

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

TECHNICAL DATA. Trimpac 256a. October 31, 2013

Features. Model DDX-LP Dry Pipe Valve System 4 (100mm), 6 (150mm) & 165mm Sizes

Model DDX-LP Dry Pipe Valve System 8 (200mm) Features. Differential latching clapper-type, lighweight, dependable construction.

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

NGP-300D. Installation, Operation, & Service Manual

TECHNICAL DATA. Q = C v P S

RK-IR Sample Draw Aspirator Adapter Operator s Manual

SERVICE MANUAL MODEL BA100BMST 100 SCFM PORTABLE AIR PANEL

INS-1500/2000 (EU) Nitrogen Generators Installation, Operation, and Instruction Manual

SERVICE MANUAL MODEL BA200AA-S1 BREATHING AIR PANEL

CSA Sample Draw Aspirator Adapter Operator s Manual

Operation Manual - PN A MENSOR MODEL 73 SHOP AIR BOOSTER

BUBBLER CONTROL SYSTEM

NGP-1000D-M1/M2/M3. Installation, Operation, & Service Manual

SERVICE MANUAL MODEL BA200AMST-S1 BREATHING AIR PANEL

TECHNICAL DATA. Q= Cv S

DESIGN DATA. Dry 105a. September 5, 2008

TECHNICAL DATA CAUTION

TECHNICAL DATA. System water supply pressure enters the priming chamber of the deluge valve (A.1) through the 1/4 (8 mm) priming line, which

Model PSI Compressor with 3-Gallon Air Tank 12VDC

SERVICE MANUAL MODEL BA020AMST BREATHING AIR PANEL

Related Products: Auto Drain Valve. Model/Specifications. Model

/ /

TECHNICAL DATA. Trimpac 247a_Euro. September 16, 2013

Data Sheet Issue A

NTF-230 OPERATION MANUAL

ACV-10 Automatic Control Valve

Speed control assembly model A-1

200 PSI COMPRESSORS - MODEL NUMBERS

INS-100/250 (EU) Nitrogen Generator Installation, Operation, and Instruction Manual

Instructions for Installation, Operation, Care and Maintenance

Model PDT Dewpoint Transmitter

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

Nitrogen Generators. PMNG Commercial Series. Section 50 Bulletin A -20

TECHNICAL DATA ACCELERATOR MODEL E-1

Installation, Operation, and Maintenance Manual

IMPORTANT SAFETY INSTRUCTIONS

Nitrogen Tyre Inflator Owner s Manual

RAM 4021-DPX Operation Manual

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

VERTICAL BLADDER TANK

100C Air Compressor Kit

N2-BLAST NITROGEN GENERATOR FPS-1750, FPS-3000 & FPS-6000 O&M MANUAL. Revision 6 Date 05/24/16

TECHNICAL DATA. Page 1 of 12

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

RK LEL Sample Draw Aspirator Adapter Operator s Manual

Balston Nitrogen Generation Systems


INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER FILTER DRYER

OPERATION & MAINTENANCE MANUAL NG6/1 YOUR RELIABLE PARNTER IN LABORATORY GAS HANDLING

BUBBLER CONTROL SYSTEM

Operating Instructions

444C DUAL PERFORMANCE VALUE PACK

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

4-7 kw/ hp. Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward

Manual Solvent Purification System. Innovative Technology, Inc.

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

HORIZONTAL BLADDER TANK

Columbus Instruments

TotalPac X Single interlock Preaction system Electric release

Installation, Operation, and Maintenance Manual

Transcription:

ECS Protector PGEN-30 (PGEN-30E) Specifications For use under U.S. Patents 8,720,591, 9,144,700 and 9,186,533 Dimensions (cabinet): 24.5 (W) x 52.5 (H) x 8.5 (D) (622mm(W) x 1,334mm(H) x 216mm(D)) Dimensions (incl. bypass): 32.5 (W) x 52.5 (H) x 8.5 (D) (826mm(W) x 1,334mm(H) x 216mm(D)) Weight: Temperature Range: Power Supply: Power Consumption: Gas Connections: Drain Connection: 152 Lbs (69 Kg) 40 F - 105 F (5 C - 40 C) 120v/1 phase/60hz - Dedicated Circuit (230v/1 phase/50hz - Dedicated Circuit) 2 Amps Air Inlet - ½ NPT Female Nitrogen Outlet - ½ NPT Female ¼ NPT Female UL 508A Listed Industrial Control Panel Ordering Information Stock Number: Replacement Filters: Gas Membrane: PGEN-30 (PGEN-30E) PGEN-FKS - Annual Maintenance PGEN-MS - 20 Year Expected Service Life) General Description The ECS Protector is designed for use in maintaining supervisory gas and facilitating the Dry Pipe Nitrogen Inerting (DPNI) process for controlling oxygen corrosion in dry and pre-action fire sprinkler systems. The ECS Protector is an on-site nitrogen generation system that is designed to be installed inline between the compressed air supply and the sprinkler system riser in dry or preaction pipe sprinkler systems. The nitrogen generator utilizes membrane gas separation technology that exhausts oxygen as a waste gas to produce 98%+ nitrogen on demand with no nitrogen storage necessary for dry or preaction systems. The ECS Protector cabinet has an external bypass valve to allow for nitrogen generator maintenance or fast fill needs, and is designed to meet the NFPA 13 30-minute fill requirement for dry pipe or preaction fire protection systems. ECS Protector PGEN-30 (PGEN-30E) 1

The ECS Protector facilitates the patented fill and purge breathing process in the fire sprinkler system when paired with a venting device installed on the sprinkler riser such as the ECS The ECS unit that includes the following components: Steel enclosure cabinet with membrane type nitrogen generator (no nitrogen gas storage) and manual bypass Power supply - 120 VAC/1 phase/60hz (230 VAC/1 phase/50hz) Single point nitrogen/air discharge ½ NPT Hour Run Meter Cycle Counter The ECS includes the following function Indications: Bypass Alarm - Nitrogen generator is in the By-Pass mode (Flashing Indicator) Leak Monitoring - Nitrogen generator running excessively (Audible Signal) The ECS includes the following monitoring outputs: System Power (Digital Output) Bypass Mode Alarm (Digital Output) Protector Manual Vent (PAV-D) or the ECS Protector Dry SMART Vent (PSV-D/DE) for dry and preaction systems. Nitrogen Generation Mode (Digital Output) Nitrogen Supply Line Pressure (Analog Output) Leak Monitoring (Digital Output) The ECS is designed to be used in conjunction with the following components as part of the complete ECS Dry Pipe Nitrogen Inerting (DPNI) system: Air maintenance device with on board adjustable regulator (recommend Victaulic Series 757, Tyco Model AMD-1 or Reliable Model A-2) Riser-mounted ECS Protector Manual Vent (PAV-D) or ECS Protector Dry SMART Vent (PSV-D) The ECS can be used with the following optional equipment: ECS Protector SMART Gas Analyzer (SGA-1) - one per nitrogen generator is recommended ECS In-Line Corrosion Detector (ILD-X) - monitoring at least one system is recommended Operating Performance Model Number Capacity based on NFPA-13 30-minute fill requirement of largest single system Nitrogen Quality Min. Supply Air SCFM (L/min) Total System Capacity Gallons (Liters) N 2 Purity at Discharge: 98% or greater (Maximum of 2.0% oxygen) N 2 Pressure at Discharge: Min of 15 psig (1 bar) Max of feed air pressure minus 15 psig (1 bar) N 2 Water Dew Point: Typically less than -70ºF (- 57ºC) Note: When connecting an ECS Protector to an existing dry pipe/preaction fire sprinkler system, the existing fire sprinkler system(s) must be limited to a maximum leak rate of less than 3 psig within a 24 hour period, per system. ECS Protector PGEN-30 (PGEN-30E) 2 Single System Capacity @ 40 psig (2.4 bar) Gallons (Liters) Single System Capacity @ 20 psig (1.4 bar) Gallons (Liters) PGEN-30/(30E) 14.3 (405) 6,500 (24,605) 1,150 (4,353) 2,300 (8,706)

Installation Instructions Installation of the ECS Protector requires five (5) steps: 1. Mount the cabinet in the appropriate installation location 2. Bring the dedicated power supply to the cabinet 3. Plumb the nitrogen/air supply line to the water based fire sprinkler risers being served 4. Plumb the condensate drain line to floor drain or building exterior 5. Connect Nitrogen generator output signals to BMS or fire alarm system, where applicable Step 1: STEP 2: Mounting the nitrogen generator cabinet The ECS Protector is designed to be mounted directly to the floor and/or the wall at the installation location. Several factors should be considered in choosing the proper mounting location for the nitrogen generator: Access to required power supply (dedicated circuit) Access to sprinkler risers being supplied from nitrogen generator Access to drain for the condensate discharge line Note: The cabinet includes pre-punched holes in the feet for floor mounting and holes in the back panel for wall mounting using standard anchors. Power Supply The ECS Protector requires a dedicated power supply to prevent interruption from other equipment. The incoming power supply line ties into the top of the terminal blocks inside the nitrogen generator cabinet (see diagram). The landing points are labeled L1, N, and G. 120v/1 Phase 60 Hz Connections (230/1 Phase 50 Hz Connections) L1 N G Step 3: Plumb the Nitrogen/Air Supply Line The nitrogen/air discharge plumbing from the ECS Protector is to be connected directly to the sprinkler system valve trim using ½ to 1 black steel, galvanized steel, or copper lines. The size of the nitrogen/air supply line shall be based on both the length of pipe between the nitrogen generator and fire sprinkler systems and the total volume of fire sprinkler systems being supplied. The nitrogen generator requires an in-line Air Maintenance Device (AMD) that is equipped with an on board field adjustable pressure regulator for each zone being served. The preferred AMD is the Victaulic Series 757. ECS Protector PGEN-30 (PGEN-30E) 3

Note: Step 4: Step 5: When both dry pipe and preaction fire sprinkler systems are connected to one nitrogen generator, additional equipment may be required if the fire sprinkler systems operate at different supervisory gas pressures. Plumb the Condensate Drain Line The ECS Protector will occasionally discharge a small amount of condensate water from the coalescing filters inside the cabinet. It is recommended that the ¼ drain connection be plumbed to a floor drain or building exterior. When plumbing to a drain is not feasible an evaporative collection chamber can be used. System Signals and Monitoring, where used The nitrogen generator cabinet has two (2) system signals and five (5) outputs that can be monitored by the facility s BMS or fire alarm system. The nitrogen generator is operating in the bypass mode which is activated when the bypass valve is in the fast fill position to fast fill the fire sprinkler system and the air supplied directly from the air compressor has reached a pressure of 20 psig (1.4 bar). (Flashing amber light) The nitrogen generator is equipped with a leak monitor audible signal which is activated when the nitrogen generator runs excessively. (Audible signal) The nitrogen generator cabinet includes system monitoring signals which can be monitored through a building monitoring system, if desired: Loss of Power (Form C contacts) Bypass Mode Alarm (Form C contacts) Nitrogen Generation Mode (Form C contacts) Nitrogen System Supply Line Pressure (Analog Signal) Leak Monitoring (Form C contacts) By-Pass Alarm Monitoring Output Nitrogen Generation Monitoring Output Power Monitoring Output Leak Monitoring Output ECS Protector PGEN-30 (PGEN-30E) 4

Typical ECS Protector Dry/Preaction System Schematic Nitrogen/Air Supply Line ECS Protector Dry Pipe Venting Device Nitrogen Generator Air Compressor Dry/Preaction Sprinkler Risers Maintenance of the ECS Protector The nitrogen cabinet contains three (3) separate cartridge filters. It is recommended that each filter be replaced as part of an annual preventative maintenance program. In some environments it may be necessary to replace filters more frequently. The filter kit for the PGEN-30 (PGEN-30E) is part number PGEN-FKS. When maintained properly the nitrogen separation membrane will provide up to 20 years of service life. Filter Replacement Procedure Preliminary Steps (taking the nitrogen generator out of service) 1. Turn the power supply to the unit off 2. Close the inlet and outlet ball valves on the bypass loop 3. Depressurize the nitrogen generator internal inlet piping by slowly unscrewing the petcock valve on the bottom of the leftmost filter housing Coalescing Filter Cartridge Replacement Procedure The filters with condensate drain tube extending from the bottom of the filter housing are coalescing filters. To replace the filter cartridges follow Steps 1 through 6 on the following page. Clear Drain ECS Protector PGEN-30 (PGEN-30E) 5

Step 1: Step 2: Step 3: Grasp the ¼ clear drain tube on the bottom of the filter housing with the right hand. With the left hand, push upward on the grey retaining ring on the filter housing outlet fitting. This will allow for the ¼ clear drain tube to be removed from the fitting. Once the ¼ clear drain tube has been disconnected, the filter housing bowl may be unscrewed from the top portion of the filter housing which is connected to the internal system piping. Once the filter housing bowl has been unscrewed, the filter cartridge inside is removed by first unscrewing the black retaining disc at the base of the cartridge and then pulling down on the cartridge. Discard the old filter cartridge and replace it with the appropriately marked filter cartridge from the filter replacement kit by pushing up so that it fits snugly onto the receiving cylinder in the upper part of the filter housing. Screw the black retaining disc back onto the central metal threaded rod. Important: HAND TIGHTEN ONLY! Top of Filter Housing Filter Cartridge Black Disc Step 4: Step 5: Step 6: Replace the filter housing bowl by screwing it onto the filter housing top. Important: HAND TIGHTEN ONLY! Reconnect the ¼ clear drain tube into the fitting on the filter housing bowl. Make sure that it fully seats in the fitting and is retained snugly. Repeat Step 1 through Step 5 for each additional filter. ECS Protector PGEN-30 (PGEN-30E) 6

Activated Carbon Filter Replacement Procedure The filter without condensate drain tube extending from the bottom of the filter housing is an activated carbon filter. To replace the filter cartridge follow the steps below: Step 7: Step 8: Step 9: Step 10: Step 11: Remove the filter housing bowl by unscrewing it from the top portion of the filter housing which is connected to the internal system piping. Once the filter housing bowl has been removed, the filter cartridge inside is removed by first unscrewing the black retaining disc at the base of the cartridge and then pulling down on the cartridge. Discard the old filter cartridge and replace it with the appropriately marked filter cartridge from the maintenance kit by pushing up so that it fits snugly onto the receiving stepped cylinder in the upper part of the filter housing. Screw the black retaining disc back onto the central metal threaded rod. Important: HAND TIGHTEN ONLY! Replace the filter housing bowl by screwing it onto the filter housing top. Important: HAND TIGHTEN ONLY! Tighten the petcock valve to the closed position. The ECS Protector can now be placed back into service. Return the ECS Protector to Service 1. Turn the power supply to the unit on. 2. Open the inlet and outlet ball valves, and close the bypass valve on the bypass loop. 3. Check inside the nitrogen generator cabinet for leaks using a soap water solution. Tighten fittings where needed. ECS Protector Optional Monitoring Equipment ECS Protector Handheld Gas Analyzer (PHGA-1): portable handheld gas analyzer includes one-button calibration and enables user to measure nitrogen concentration at nitrogen generator cabinet or gas sampling ports on ECS venting devices ECS Protector SMART Gas Analyzer (SGA-1/1E): permanently installed near an ECS Protector Manual/ SMART Vent to continuously report nitrogen gas concentration to a building information or management system; includes digital display and provides 0-5V DC or 4-20mA output signals ECS In-Line Corrosion Detector (ILD-X): installed in-line within the fire sprinkler system piping at locations most susceptible to corrosion; provides either a local push-button test/indicator or control panel monitoring ECS Protector PGEN-30 (PGEN-30E) 7

Wall Mount Total System Capacity Skid Mount Stand Alone w/separate Air Compressor PGEN-3 PGEN-5 PGEN-10 PGEN-20 PGEN-30 PGEN-40 PGEN-50 PGEN-60 675 gal 950 gal 2,000 gal 3,200 gal 6,500 gal 11,000 gal 18,500 gal 22,500 gal Single System Capacity @ 40 psi (1) 215 gal 265 gal 560 gal 950 gal 1,150 gal 1,440 gal 2,025 gal 2,900 gal Single System Capacity @ 20 psi (1) 540 gal 590 gal 1,120 gal 1,800 gal 2,300 gal 2,880 gal 4,050 gal 5,800 gal Air Compressor Integral Integral Integral Integral Separate Separate Separate Separate Size (H x W x D) 36x24x9 36x24x9 38x29x11 57x32x40 Weight 115 lbs 125 lbs 175 lbs 420 lbs 152 lbs(2) 264 lbs(2) 300 lbs(2) 300 lbs(2) (1) (2) (3) Single system capacity based on 30 min. fill requirement of largest single sprinkler system; a secondary air compressor with normally closed isolation valve can be used to meet fill requirement for larger individual systems Size and weight of nitrogen generator only, does not include separate air compressor All nitrogen generators include 1 year manufacturer s warranty per ECS terms and conditions Engineered Corrosion Solutions 11336 Lackland Road St. Louis, MO 63146 Phone 1-314-432-1377 www.ecscorrosion.com 8