Intensa GO Alternate Care Ventilator

Similar documents
VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

WILAmed INTENSA. Intensive Care Ventilator System

IEC C LASSIFICATIONS:

Panther 5 Acute Care Ventilator

Airox Supportair Ventilator

Technical Data and Specifications

VENTIlogic LS VENTIlogic plus

Introducing Astral. Greater freedom. Confident care. Designed efficiency

Expanding versatility. The upgraded Trilogy family of ventilators continues to meet the changing needs of your patients

Meet the changing needs of your patients. Trilogy Series, with advanced ventilator technology

VENTILATION SERVO-s EASY AND RELIABLE PATIENT CARE

SLE5000 Infant Ventilator with HFO

EVE. The mobile Ventilation Concept from Emergency to Intensive Care. easy - light - smart. Ventilation

NEONATAL/INFANT VENTILATOR

SLE4000. Infant Ventilator with touch-screen operation. When the smallest thing matters

Automatic Transport Ventilator

PERFORMANCE EVALUATION #34 NAME: 7200 Ventilator Set Up DATE: INSTRUCTOR:

Oxylog 3000 plus Emergency & Transport Ventilation

DATA SHEET. VENTILATION SERVO-s

Milestones of Aeonmed Ventilators

V8600 Ventilator. Integrated Invasive & Noninvasive Ventilation

INTENDED USE CLASSIFICATION PHYSICAL CHARACTERISTICS

V8800 Ventilator System. Your healthcare, we care.

INTENSIVE CARE VENTILATORS

MEDUMAT Standard a MEDUMAT Standard. The Ventilation Standard for Professionals

Dräger Savina Sub-Acute Care Ventilation

Flight Medical presents the F60

Hospital and Transport for Controlled Breathing

Patient Setup Information

GE Healthcare. Centiva/5 Critical Care Ventilator. Meet a new level of expectations

State-of-the-art anesthesia technology

Supporting your patients every breath

Dameca MRI 508. State-of-the-art MRI technology

A9600 Anesthesia Workstation. Your healthcare, we care.

Oxylog 2000 plus. Step up your performance. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Stephanie. Pediatrics. The ventilation system for neonatology

Your patients, our primary focus. Siesta i Whispa anesthesia machine

CPAP Devices - Masks - Accessories for respiratory assistance in CPAP

The Crossvent 2i+ 2. Ventilator Concept (brief theory of operation and features)

Inspiration 7i Ventilator

Automatic Transport Ventilators. ICU Quality Ventilation on the Street.

Using Common Ventilator Graphics to Provide Optimal Ventilation

Blease900 Ventilator PATIENT CENTERED VENTILATION

SERVO-s v8.0 Data sheet

The centerpiece of a comprehensive anaesthesia workstation

Operation and Maintenance of the MCV100 and MCV100-B Portable Ventilator

SLE5000 Neonatal Ventilator with High Frequency Oscillation

Oxylog VE300 Emergency & Transport Ventilation

Ventilator Training Module

Siesta i Whispa Integrated technology

Fabius plus. The plus that makes all the difference. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Fabius plus. The plus that makes all the difference. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Evita 2 dura. High-end ventilation in your patient s best interests. Because you care

Emergency Transport and Ventilation

Servo UNIVERSAL ADVANCED VENTILATION PLATFORM ALL PATIENT CATEGORIES

fabian Therapy evolution Our 2-in-1 device

AUTOVENT 4000 VENTILATOR

evolution 3e Ventilators

HAMILTON-C2 HAMILTON-C2. The universal ventilation solution

Basics of Mechanical Ventilation. Dr Shrikanth Srinivasan MD,DNB,FNB,EDIC Consultant, Critical Care Medicine Medanta, The Medicity

6 th Accredited Advanced Mechanical Ventilation Course for Anesthesiologists. Course Test Results for the accreditation of the acquired knowledge

Operation and Maintenance of the EPV200 Portable Ventilator

Narkomed MRI-2. A perfect fit for the MRI environment. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Dräger Savina 300 Classic ICU Ventilation and Respiratory Monitoring

MT The secret of harmonious breathing BABYLOG 8000 PLUS

AUGUST ANESTHESIA MACHINES MEDICAL PRODUCTS ANESTHESIA MACHINES. Quality System Standard applied: ISO 9001, ISO 13485

fabian HFO Our 4-in-1 device

Anesthesia Workstation

Health Professional Info

Update to RS-232 commands. Changing patient from NIV to INVASIVE Vent Type. SNDF command

Department of Paediatrics

Mechanical Ventilation. Mechanical Ventilation is a Drug!!! is a drug. MV: Indications for use. MV as a Drug: Outline. MV: Indications for use

fabian HFO: Modular, Powerful, Versatile.

EvitaXL. Excellence throughout the ventilation process. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Technical Specifications

APUS Anesthesia Machines

C O R P O R AT E B R O C H U R E

Entry to the premium class!

2015 Hamilton Medical AG. All rights reserved. Printed in Switzerland.

Transport ventilation without compromise DRÄGER OXYLOG 3000 PLUS

Your patients, our primary focus

Dräger Savina 300 Select ICU Ventilation and Respiratory Monitoring

Astral in AirView: Improving patient care through connectivity. ResMed.com

Better to have one OXYLOG 3000

HAMILTON-C1 neo. Technical specifications

Mechanical Ventilation. Flow-Triggering. Flow-Triggering. Advanced Concepts. Advanced Concepts in Mechanical Ventilation

HAMILTON-MR1. Technical specifications HAMILTON-MR1

Oxylog Better to have one. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Fabius Tiro TM. Designed for your environment. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Organis TestChest. Flight Simulator for Intensive Care Clinicians


SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products

Device overview. 6 Breathing circuit connection. Note: When the remote control foot pedal is connected, the manual switch is disabled.

MEDICAL EQUIPMENT IV MECHANICAL VENTILATORS. Prof. Yasser Mostafa Kadah

MEDUMAT Transport. High-End Ventilation in Any Situation

SLE4000. Infant Ventilator with touch-screen operation. When the smallest thing matters

Oxylog 2000 plus Emergency & Transport Ventilation

patient education program 4156 South 52 nd Street, Omaha, NE ChildrensOmaha.org/HomeHealthcare

Multi-Gas Analyzer. Multi-Gas Analyzer bcgroupintl.com. Features - MGA MGA-3050 Multi-Gas Analyzer

Transcription:

EN Intensa GO Alternate Care Ventilator 0197

Intensa GO Versatility and simplicity The all new WILAmed Ventilator INTENSA Go offers great versatility and simplicity. It is designed to ventilate (invasive or non-invasive) adult and pediatric patients, starting at 50 ml tidal volume and at least 5 kg body weight. Thanks to its lightweight and durable design, powerful hotswappable batteries (2 x 4,5 hours) ensure comfortable portability. Its unique ventilation functions are making it the perfect choice in the critical- and home care environment, either stationary or mobile. Innovative features such as LIAM (Lung Insufflation Assist Maneuver), three storable ventilation programs, volume compensation, AirTrap Control, Trigger lockout and the expiratory ramp gives you quick and reliable support with ideal therapy settings. More innovative features Smart mobility concept Compatible with multiple Breathing Circuits Configurations Optional double limb patient circuit with including active valve for volume-controlled ventilation modes (avcv, VCV) Innovative features such as integrated cough support LIAM, mobilizes airway secretions, making it easier for patients to cough Three storable ventilation programs Mouthpiece ventilation and volume compensation Particularly suited for COPD patients: the features exhalation monitoring AirTrap Control, Trigger lockout and expiratory ramp Simple and direct monitoring of oxygen saturation and pulse with the optional SpO 2 module Shock tested according IEC 60068-2-27 Vibration tested according IEC 60068-2-64 Just GO with one of the best ventilators in its class Possibility to store three individually set ventilation programs for patients who need varying degrees of ventilation support. With the simple press of a key, the doctor, nurse or patient can select the individual programs to satisfy the patient s needs. LIAM (Lung Insufflation Assist Maneuver): the integrated cough support is easy to use and requires no change of interfaces. The patient himself or a nurse can safely activate the LIAM function. Volume compensation: Function to guarantee a pre-set target volume. The speed can be set in three levels. 2

100% mobility and versatility in invasive and non-invasive ventilation Two options for mouthpiece ventilation INTENSA Go is equipped with two options for mouthpiece ventilation, called MPVp in pressure-controlled and MPVv in volume-controlled mode. Both modes are available with all breathing circuit systems. Mouthpiece ventilation provides the patient maximum freedom and independence during therapy. Three storable ventilation settings allow ideal combination of daytime mouthpiece ventilation with night-time ventilation means. The mobility concept ensures safety and reliability in the delivery of required ventilation. Mobility wherever it s needed Mobile use for intra-hospital transfers: With 9 hours of battery power (internal rechargeable battery and optional replaceable battery* have a capacity of 4.5 hours each), the devices can easily adapt to any change of location on the go. Dedicated features for the treatment of COPD patients AirTrap Control: Exhalation pressure relief to prevent dynamic hyperinflation. Thanks to AirTrap Control, VENTIlogic LS and VENTIlogic plus automatically regulate pressure to a frequency and expiration time Ideal for the patient. The titration process is thereby significantly simplified. Trigger lockout: effective protection from false triggering and trigger artefacts at higher trigger sensitivity. The fast way to perfectly synchronized ventilation. Expiratory pressure ramp: temporary pneumatic splint in airways at the start of expiration to counteract expiratory collapse of airways. The expiratory flow remains larger on average, the volume can be exhaled more easily and respiratory position can be lowered. Mobile use at home: INTENSA Go provides your patients with maximum mobility. There when you need it Leakage is reliably compensated for in volume and pressure controlled modes. The highperformance blower ensures continuous patient care in mobile use and difficult ventilation situations, even with imprecise fit of patient interface. Intensa GO3

Intensa GO Parameters and Ranges Parameters/Ranges Passive Valve modes: Active Valve modes: Steps/Ventilation Modes CPAP, S, ST, MPVp, MPVv PSV, PCV, apcv, SIMV, MPVp, MPVv, VCV, avcv Special therapeutic functions AirTrap Conrol, Trigger lockout, Expiratory pressure ramp, Three ventilation programs, LIAM, Volume compensation, Mouthpiece ventilation Tidal volume I:E ratio Inspiration Time Increment Accuracy 50 3000 ml 15% to 67% of breathing period 1% +1% Trigger level Adjustable in 8 steps for inspiration and 14 steps for exhalation (from 5% to 95% of maximum flow), can be switched off for exhalation in ST mode Pressure increase speed Can be set in six (6) different levels Pressure decreased speed Leakage system: Valve system: IPAP pressure range: PEEP / EPAP pressure range: CPAP pressure range Respiratory Rate Maximum flow with oxygen: Can be set in six (6) different levels One permanently set level 6 to 40 hpa (Passive Valve) 4 to 40 hpa (Active Valve) 4 to 20 hpa (Passive Valve) 0 to 20 hpa (Active Valve) 4 to 20 hpa (Passive Valve) 5 to 45 bpm 15 lpm at 1000 hpa 4

Intensa GO Technical Specifications Product Specifications Product class as per directive 93/42/EEC Dimensions (W X H D) II b 240 x 153 x 340 mm Weight: Without replacable battery: Including replacable battery: Approx. 5.9 kg Approx. 6.5 kg Temperature range Operation Storage +5 C to +35 C -40 C to +70 C Air pressure range 600 11 hpa (below 700 hpa leakage is to be kept low since the device my not be able to compensate for high ventilation pressures!) Electrical connections Power consumption at Operation Standby Maximum power consumption 110 x 230 V AC, 50 60 Hz Tolerance -20%, +10% 230 V 110 V 0,35 A 0,80 A 0,05 A 0,13 A 120 W Switching capacity Remote alarm connection 60 V DC/2A; 42 V AC/2A Battery capacity* Internal rechargeable battery Replaceable/rechargeable battery 4.5 hours 4.5 hours * The capacitry depends on the ventilator settings and the battery s age and state of charge Time required to charge battery via the Ventilator Approx. 6 hours per battery 5

Intensa GO Order Information Part Number Item Qty. 100.304 Intensa Go Basic Unit with Adult Double-Limb Breathing Circuit 1 100.348 Vent Cart 1 100.363 SpO 2 Module 1 100.349 Replaceable battery 1 100.364 Connection cable for nurse call, 10 m 1 100.365 Connection cable for nurse call, 30 m 1 100.366 Water resistant transport bag 1 Accessories 100.900 AIRcon Respiratory Gas Humidifier, 230 V 1 271.142 BTS3254A, Adult Single-Limb Breathing Circuit, heated 10 271.183 BTS2150A, Pediatric Single Limb Breathing Circuit, heated 10 271.184 BTS3239A, Adult Double-Limb Breathing Circuit, heated 10 271.510 BTS2153A, Pediatric Double-Limb Breathing Circuit, heated 10 270.584 BTS3117, Adult Single-Limb Breathing Circuit 10 270.598 BTS256, Pediatric Single-Limb Breathing Circuit 10 271.562 BTS3395, Adult Double Limb Breathing Circuit 10 270.603 BTS265, Pediatric Double Limb Breathing Circuit 10 500.200 Bacteria Filter 10 6

Intensa GO Order Information Part Number Item Qty. Patient Interfaces Critical Care Disposable 250.238 Intensa FFM, NV + AAV (L1), Size S 5 250.237 Intensa FFM, NV + AAV (L1), Size M 5 250.236 Intensa FFM, NV + AAV (L1), Size L 5 250.235 Intensa FFM, NV, Size S 5 250.234 Intensa FFM, NV, Size M 5 250.233 Intensa FFM, NV, Size L 5 250.232 Intensa FFM, Vented (L2), Size S 5 250.231 Intensa FFM, Vented (L2), Size M 5 250.230 Intensa FFM, Vented (L2), Size L 5 7

WILAmed GmbH Medizinische Geräte und Zubehör Gewerbepark Barthelmesaurach Aurachhöhe 5 7 91126 Kammerstein (Germany) Phone: +49 9178 996999-0 Fax: +49 9178 996778 info@wilamed.com www.wilamed.com Version 1.2 Stand: 01/10/2016 REF 890.407.0 All rights reserved. Subject to change.