GE Healthcare. Centiva/5 Critical Care Ventilator. Meet a new level of expectations

Similar documents
GE Healthcare. Aestiva/5. More than superior ventilation

V8600 Ventilator. Integrated Invasive & Noninvasive Ventilation

VENTILATION SERVO-i INSPIRATION IN EVERY BREATH

VENTILATION SERVO-s EASY AND RELIABLE PATIENT CARE

A9600 Anesthesia Workstation. Your healthcare, we care.

IEC C LASSIFICATIONS:

V8800 Ventilator System. Your healthcare, we care.

Milestones of Aeonmed Ventilators

Introducing Astral. Greater freedom. Confident care. Designed efficiency

Technical Data and Specifications

Panther 5 Acute Care Ventilator

PERFORMANCE EVALUATION #34 NAME: 7200 Ventilator Set Up DATE: INSTRUCTOR:

Patient Setup Information

D Beyond essentials DRÄGER SAVINA 300 SELECT

GE Healthcare. Avance Carestation. Upgrade promotions guide

Anesthesia Workstation

HAMILTON-C2 HAMILTON-C2. The universal ventilation solution

O-Two Self-Study Guide. e600 Transport Ventilator Ventilation Modes

Flight Medical presents the F60

Automatic Transport Ventilators. ICU Quality Ventilation on the Street.

Supporting your patients every breath

Expanding versatility. The upgraded Trilogy family of ventilators continues to meet the changing needs of your patients

Supporting you in saving lives!

The centerpiece of a comprehensive anaesthesia workstation

DATA SHEET. VENTILATION SERVO-s

An intuitive and innovative answer to your anaesthesia challenges

State-of-the-art anesthesia technology

fabian HFO: Modular, Powerful, Versatile.

Understanding and comparing modes of ventilation

Meet the changing needs of your patients. Trilogy Series, with advanced ventilator technology

Focused on essentials DRÄGER SAVINA 300

Inspiration 7i Ventilator

Ventilator Training Module

D Beyond essentials DRÄGER SAVINA 300 SELECT

Your patients, our primary focus. Siesta i Whispa anesthesia machine

Selecting the Ventilator and the Mode. Chapter 6

fabian HFO Our 4-in-1 device

Intelligent Ventilation solution from ICU to MRI

APUS Anesthesia Machines

Blease900 Ventilator PATIENT CENTERED VENTILATION

Mechanical Ventilation. Mechanical Ventilation is a Drug!!! is a drug. MV: Indications for use. MV as a Drug: Outline. MV: Indications for use

Aespire 7100 Essential performance Compact design

HAMILTON-G5. The modular high-end ventilation solution

Puritan Bennett 840 Universal Ventilator

Anesthesia Solutions. Prima SP and Prima SP2 Anesthesia Systems. The Future of Anesthesia. Partnership for Life

Narkomed MRI-2. A perfect fit for the MRI environment. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Update to RS-232 commands. Changing patient from NIV to INVASIVE Vent Type. SNDF command

How Ventilators Work. Chapter 3

Peter Kremeier, Christian Woll. 2nd. Understanding and comparing modes of ventilation. The Kronberg List of Ventilation Modes

Oxylog 3000 plus Emergency & Transport Ventilation

IMPACT. Uni-Vent. Eagle. Model 754 Portable Ventilator

INTENSIVE CARE VENTILATORS

WATO EX-65 NEW. the enhanced anaesthesia workstation

Focused on essentials DRÄGER SAVINA 300

SLE5000 Infant Ventilator with HFO

HAMILTON-C3. The compact high-end ventilator

SLE4000. Infant Ventilator with touch-screen operation. When the smallest thing matters

Fabius plus. The plus that makes all the difference. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Fabius plus. The plus that makes all the difference. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Astral in AirView: Improving patient care through connectivity. ResMed.com

New A7 Anesthesia Workstation

Advisedly design for all critical juncture. ihope RS/RV Series turbine based ventilatior

Fabius Tiro TM. Designed for your environment. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Astral in AirView: Improving patient care through connectivity. ResMed.com

fabian Therapy evolution Our 2-in-1 device

Monnal T60. Touch and Breathe.

Transport Ventilators

WILAmed INTENSA. Intensive Care Ventilator System

Dräger Savina Sub-Acute Care Ventilation

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

Airox Supportair Ventilator

MEDICAL EQUIPMENT IV MECHANICAL VENTILATORS. Prof. Yasser Mostafa Kadah

Hospital and Transport for Controlled Breathing

SERVO-s v8.0 Data sheet

S/5 Aespire. Quick Reference Guide

patient education program 4156 South 52 nd Street, Omaha, NE ChildrensOmaha.org/HomeHealthcare

D Designed for non-invasive ventilation DRÄGER CARINA

Siesta i Whispa Integrated technology

SERVO-air ventilator. Datasheet for system version 2.1

ihope Series Ventilator Nov. 2017

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products

Dameca MRI 508. State-of-the-art MRI technology

Intensa GO Alternate Care Ventilator

ekom Compressor for Medical Air Sonata with Ekom

evolution 3e Ventilators

A few seconds after turning on, the screen changes to Set Up Screen Before adjusting the pressure, calibrate the O 2 sensors

MT The secret of harmonious breathing BABYLOG 8000 PLUS

HAMILTON-C3 HAMILTON-C3. The compact high-end ventilator

Oxylog 2000 plus. Step up your performance. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Emergency Transport and Ventilation

2015 Hamilton Medical AG. All rights reserved. Printed in Switzerland.

The Crossvent 2i+ 2. Ventilator Concept (brief theory of operation and features)

Evita 2 dura. First-class ventilation in your patient s best interests. Because you care. Emergency Care OR/Anesthesia Critical Care Home Care

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

SLE5000 Neonatal Ventilator with High Frequency Oscillation

INTENDED USE CLASSIFICATION PHYSICAL CHARACTERISTICS

Safe Accurate Reliable. CWM-301 Anesthesia System

Your patients, our primary focus

PATIENT SETUP QUICK REFERENCE GUIDE

e700 Automatic Transport Ventilator User Manual e700 User Manual (15PL Rev.14 28_8_2017)

Transcription:

GE Healthcare Centiva/5 Critical Care Ventilator Meet a new level of expectations

Intergrating performance and value Marry form and function In an environment where time and space are tight, the design and flexibility of the Centiva/5 offers you greater convenience in your practice. The compact size of the Centiva/5 frees up space in your cramped critical care rooms. The comparatively small ventilator engine can be strategically placed out of the way while its detachable monitor and control panel can be mounted on the bed or wall to keep the area around the patient clear for ease of movement. But that is only the beginning with the Centiva/5.

The Centiva/5 helps you help patients by providing premium ventilation features. It makes use of Airway Resistance Compensation (ARC) to deliver and support breaths, overcoming the inherent resistance of an artificial airway. Non-Invasive Mask Ventilation (NIV) is available to help you avoid the use of an invasive artificial airway. The Centiva/5 also insures its performance with Compliance and Resistance Compensation (CRC). The CRC checks the breathing circuit and automatically compensates for the patient circuit compliance, resistance and for leaks. The Centiva/5 also measures and compensates the flow and O 2 concentration that is delivered through a special port that drives a pneumatic nebulizer in synchrony with the patient s breathing. The Centiva/5 comes standard with advanced modes of ventilation including Volume Control (VCV and AssistVCV) and Synchronized Intermittent Mandatory Ventilation (SIMV-VC) with selectable Pressure Support (PSV). Volume controlled breaths can be Pressure Limited (PLV) to maintain safe and efficient ventilation. The Centiva/5 also offers pressure controlled modes implemented as Bi-Level, a patient synchronized mode where the patient can inhale and exhale at any time during the breath cycle (Active Exhalation Valve). Also in Bi-Level mode, breaths can be Pressure Supported (PSV) during the exhalation phase giving you access to highly inverted I:E ratios (down to 9:9:1) which allows for implementation of pressure release mode strategies. Spontaneous breathing modes, such as CPAP and PSV, are also offered. The Centiva/5 is equipped with the above modes as well as adjustable ByFlow, adjustable Flow Trigger and adjustable termination criteria, continuous leak compensation and the ability to use the ventilator Non Invasively (NIV), which provides efficient ventilation to help you support a wide range of patients.

Powerful, compact and versatile Relying on years of experience with clinicians and patients worldwide, GE Healthcare knows that the shift is never over in the critical care unit. One of our solutions for the ever present, ever challenging demands of this lifesaving environment is the Centiva/5 Critical Care Ventilator. It s the first ventilator of its size to offer the highest level of performance with simple, direct operation allowing the clinicians in your unit fully utilize all the capabilities this unit offers. Compact ventilator with detachable display allowing flexible placement on a mobile cart or pendant/shelf mounted Two display sizes to choose from: 6.5 and 12 touch screen Capable of ventilating adult to pediatric patients and optionally newborns Familiar Datex-Ohmeda user interface Alternate power source-internal and external batteries Flexible cart with rails for mounting heated humidifier and patient circuit arm Optional EVAir03 medical air compressor, which can be integrated inside the mobile cart Optional cylinder kit which can be fitted in the cart which in conjunction with the external battery pack facilitates transporting critically ill patient within in your hospital Easy to clean and maintain exhalation valve ensuring short turn around times between patients Making patients the number one priority Centiva/5 is designed to help safeguard your patients Power off disregard. Power cannot be turned off while a patient is being ventilated Automatic Patient Detection (APD). Sounds a high priority alarm and automatically activates the start ventilation menu when a patient is connected while the venilator is in standby Battery backup. Internal battery provides 30 minutes of backup power

The first breath is safeguarded So is the second. So is the third, and fourth, and every breath that follows with the assistance of the Centiva/5. Our ventilator provides reliability when you need it, and even more importantly, in the way your patient needs it. The Centiva/5 safeguards spontaneously breathing patients by offering CPAP/PSV mode with fully adjustable Apnea backup ventilation. The ventilator is designed to allow you to preset the unit in standby mode and be ready during patient admission. With the Automatic Patient Detection (APD) feature, the Centiva/5 will alert you and come out of standby and begin ventilation when a patient is connected. By the same mechanism the Centiva/5 cannot be placed in Standby or be turned off while a patient remains connected to the patient circuit. The Centiva/5 offers an Automatic Suction Routine (ASR) feature. ASR helps nurses with automatic pre- and post-oxygenation and places the ventilator into standby during the suction procedure. The real value of the Centiva/5 You don t have to compromise performance to work with a ventilator that is simple to operate. On the contrary, the Centiva/5 enhances performance with easy-to-use tools that put your focus where it should be. On the patient. The familiar Datex-Ohmeda user interface is employed for straightforward operation. Soft keys and simple menu navigation help eliminate confusion and allow new staff to be trained quickly. The monitor is detachable for greater accessibility. View full color pressure and flow waveforms and displays of set and measured parameters. Alarms clearly state conditions and warnings in plain language. You can also rely on the Centiva/5 for an automatic system check to maintain the ready status of the machine. Alternatively, you can bypass the system check with ease in an emergency ventilation situation. With only three parts that come in direct contact with patient exhalation, the detachment, cleaning and sterilization process of the Centiva/5 ventilator is minimal, thus saving valuable time and money.

Looking out for them, by looking after itself To assist you and help safeguard patients, careful checks and backup systems have been installed into the Centiva/5. It monitors value defaults during the switching of modes, and is programmed with automatic ventilation and alarm default settings for adult, pediatric and newborn categories. In addition, the Power off disregard feature makes it impossible to turn off the power or switch to standby mode when a patient is being ventilated. The Centiva/5 is also equipped with an internal battery with 30 minutes of backup power in the event of a pulled plug or power outage.

Unleash the power of the Centiva/5 When you choose the Centiva/5 with the larger 12 touch screen you can enhance the operation of this ventilator with a host of additional features, which allow even more efficient and streamlined patient workflow. Monitor the patient condition and evaluate weaning readiness by performing intrinsic PEEP measurements, RSBI and a unique indicator that allows you to visually evaluate how the work of breathing is shared between the patient and the ventilator Follow the patient s condition and monitor and document ventilation by having access to over 12 days of trend data and over 1000 events: settings changes out and alarm activation/deactivations (optional capability) Choose a hybrid ventilation mode, Bi-Level VG where the clinician sets a target mandatory tidal volume and the ventilator delivers pressure controlled synchronized breaths while modulating the inspiratory pressure to target the set tidal volume as the patient s condition changes. Get the assurance and familiarity of a volume-controlled ventilation mode without compromising on all the advantages that BiLevel Pressure Ventilation, with the ability to breathe spontaneously at any time, offers you (optional capability) Ventilating in Bi-Level VG Viewing patient trends Startup screen

2005 General Electric Company All rights reserved. GE and GE Monogram are trademarks of General Electric Company. Centiva is a trademark of Datex-Ohmeda, Inc. Bi-Level VG is a trademark of TIM GmbH. Datex-Ohmeda, Inc., a General Electric company, going to market as GE Healthcare. For more than 100 years, healthcare providers worldwide have relied on GE Healthcare for medical technology, services, and productivity solutions. So no matter what challenges your healthcare system faces, you can always count on GE to help you deliver the highest quality healthcare. For details, please contact your GE representative today. GE Healthcare P.O. Box 7550 Madison, WI 53707-7550 USA www.gehealthcare.com GE Healthcare P.O. Box 900, FIN-00031 GE, Finland Tel. +358 10 394 11 Fax +358 9 146 3310 www.gehealthcare.com CC3662-C 10/05