Pneumatic pressure switch 20DD

Similar documents
Model range*1) Switching pressure difference

Mechanical Pressure Switches for overpressure, vacuum pressure and differential pressure

Mechanical Pressure Switches for overpressure, vacuum pressure and differential pressure

SPCH/ Blowing block

Mechanical Pressure Switches for overpressure, vacuum pressure and differential pressure

Pressure switch Type BCP

Pressure Switches Application Guideline

Pressure switch and Thermostat CAS

4/2 way Pneumatic Solenoid Valve

Pressure Transmitters 36 F-27839

[Instruments for vacuum measurement, checking and adjustment] 3

SITRANS P measuring instruments for pressure

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

V83 series Redundant valve manifold systems - Modular with bypass 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

Mechanical Pressure Switches for overpressure, vacuum pressure and differential pressure

Compact pressure switches for gas and air

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

DSL, DSH: Specially designed pressure limiter

Mechanical Pressure Switches for overpressure, vacuum pressure and differential pressure

MECAIR CSN RAINTIGHT ENCLOSURE CLEAN AIR SOLUTIONS PRODUCT LEAFLET

compact ejector, Series ECM with Adjustable release pulse with silencer With filter vacuum switch: electronic 2 x PNP

SPD310/SPD360 Air Differential

KM/ Stainless steel air bellows Single acting Ø 220 to 400 mm

Pressure Switch for gas and air GGAO-A4

Measurement of Low GAS & Liquid Flows

Series P48. Pressure Controls for Steam, Air or (hot) Water. Product Bulletin. Generous wiring space provided. Splash-proof enclosure (IP54)

Electronic relative and differential pressure switch type 616

2/2-Way Solenoid Control Valve

DSB, DSF: Pressure monitors and pressure switches

R84G - Excelon Plus Modular System Pressure regulators

Quick Release Couplings 233 Series

Pressure transmitters EMP 2

Non-Return Valves T55 Series

4 qwer 2/2 3/2 4/2. Intrinsically Safe. Air and Inert Gas Intrinsically Safe Valves Brass, or Stainless Steel Bodies 1/4" to 1" NPT SERIES.

FEPA PNEUMATICALLY AND SOLENOID ACTUATED VALVES, ONE UNIT MOUNTED TYPE VPG

Types and approvals. Page 1/6. Data Sheet

Pressure switch and Thermostat Type KPS

2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version

C-Flow Coriolis Mass Flow Meters

Pressure controls for hydro carbons, zone II applications, Type KPE

Mechanical Pressure Switches for overpressure, vacuum pressure and differential pressure

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Pressure switch KP-E. Data sheet

Pressure Switch for gas and air

Pressure control, differental pressure control and thermostat Type RT

Pressure Switch for gas and air

DSB, DSF: Pressure monitors and pressure switches

The Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure

Inverse Proportional Pressure-Relief Cart., Size 2 4

Pressure switch for gas and air

Mechanical pressure switches

SCH. Mechanical Pressure Switches. for overpressure, vacuum pressure and differential pressure

Pressure switch and Thermostat KPS

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Product Catalogue MINICOMB. Switches for Pressure and Vacuum

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application:

Pressure controls, differential pressure controls type RT

Introduction. Description. Series P48 Pressure Controls for Steam, Air or (hot) Water. Feature and Benefits

Gas density monitor With integrated transmitter Model GDM-100-TI

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

Inverse Prop. Pressure-Relief Cart., Size 2 4

Note: the lock-out circuit must be in accordance with Section 8.7 of DIN/VDE Twin thermostats ATH.-SW-2020 ATH.-SW-2070 ATH.

Mass Flow Controller (MFC) for Gases

Inductive Linear Displacement Transducers Model IW 260 Measuring strokes: 80 mm, 170 mm, 240 mm, 360 mm

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

B74G - EXCELON Modular System General purpose filter/regulator

Solenoid valves VZWF, force pilot operated

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

Instruction Manual Differential Pressure Transmitter

OPTIBAR P 1010 C Technical Datasheet

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

Data sheet. Pressure switches and thermostats Type KPS 10/2003 DKACT.PD.P10.E B0782

Pressure switch, Differential pressure switch and Thermostat RT-E

Inverse Proportional Pressure-Relief Cart., Size 2 4

Relative and differential pressure transmitter type 692

Pressure switches and thermostats, type KPS

Mass Flow Meter (MFM) for gases

Valvex Valves for Mining Applications

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

250 (9.84) 170 (6.69) 225 (8.85) 75 (2.95) 300 (11.81)

Instruction Manual Differential Pressure Transmitter

Differenz-Drucktransmitter Differential pressure transmitter Transmetteur de pression différentielle bar

Mass Flow Meter (MFM) for Gases

VPPC02, VPPC08 3-way proportional pressure control valve, electronic closed loop control

KM/31000 (Stainless steel end plates) Air bellows, single acting

GA24 Technical Datasheet

Expansion Thermometers Stainless Steel Series, Model 70

COMPONENT SPECIFICATION M80-7XX SERIES CONNECTORS - THREE ROW

Relative pressure switch type 521

SOLENOID VALVES AND PNEUMATIC VALVES

Inverse Proportional Pressure-Relief Cartridge, Size 10

QPL... Pressure Switches. Siemens Building Technologies HVAC Products

Nugget 120 V14 Series

Gas Pressure Switch for DMV safety shutoff valves

Pneumatic valve islands

ISO Sub-bases. Port sizes G 1 /4 - G1 and 1 /4NPT - 1 /2NPT. Sub-bases tovdma specification, for ISO sizes #1, #2, #3 and #4

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

MANUAL KPS Pressure Control Valve

2/2-way proportional valve

Transcription:

Sensor system: stainless steel 0,2 to 6 bar Microswitch with gold plated contacts (suitable for intrinsically safe operation) High accuracy (max. scattering < 1,5%) Excellent sealing properties (better than < 10-7 mbar l s-1) For mounting differential pressures with high accuracy and sensitivity Technical data Medium: Neutral, aggressive, non-inflammable gases and liquids Repeatability: ±1% full scale (depending on pressure regulation) Switching element: Microswitch with gold plated contacts Electrical connection: M20 x 1,5 Degree of protection: IP65 Temperature: Fluid Ambient At switching element -20*... +100 C -10*... +80 C +80 C max. *Pease contact our technical servie for use below +2 C. Mounting position: Optional Allowable vibrations: Max. 4 g (sinusoidal) Materials: Housing: aluminium diecast Pressure sensor: brass or stainless steel Sealing: stainless steel bellows p Ordering example See page 2 2 3 1 Switching function: Microswitch SPDT Terminals 1 3: Contacts close on rising pressure Terminals 1 2: Contacts open on rising pressure N/UK 5.11.025.01

General informations (switching pressure difference fixed one pressure sensor *1) Type Differential pressure range *2) pvu min... pvo max. (VDI 3283) Switching pressure difference lower upper range range Operating pressure range *3) Max. allowable pressure *4) Switching cycles per minute (min -1 ) Pressure sensor material Housing Bellows Other materials Connection 1819205 0,2... 1,6 0, 0,17-1... 16 20 10 Brass Stainless steel Solder G1/4 1,20 1 1819405 0,3... 4 0,2 0,25-1... 16 20 10 2.0401 1.4401 1819505 0,5... 6 0,6 0,7-1... 25 30 10 *1) Tested in accordance with DIN 89011, 5.2., within the frequency range 25... 100 Hz; within the frequency range 2... 25 Hz tested with amplitude 1.6 mm. *2) The differential pressure is the pressure difference between both pressure sensing elements under operating conditions. *3) The working pressure range indicates the required minimum pressure as well as the load on the pressure sensor under operating conditions. *4) Even short pressure peaks must not exceed this value during actual operation (max. value = max. testing pressure) Internal thread Total weight (kg) Dimensional drawing No. Ordering example Differential pressure switch with fixed switching pressure difference, differential pressure 0,2... 1,6 bar, operating pressure -1... 16 bar, port size female Type: 1819205 Warning These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under Technical Data. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult NORGREN. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products. N/UK 5.11.025.02 Our policy is one of continued research and development. We therefore reserve the right to amend, 6/06

Accessories Bracket reducing nipple Surge damper Pressure port adaptors See page 5 See page 5 See page 5 0574772 (steel) 0553258 (stainless steel G1/4A... G1/4) 0553831 (G1/2... 1/2 NPT) 0553908 (stainless steel) 0574773 (brass/steel) G1/4A... G1/4) 0550083 (G1/4A... G1/2A) 0551894 (stainless steel G1/2... G1/2A) 0574764 (G1/4A... G3/8) 0574765 (G1/4A... 1/4 NPT) Switching capacity commutator with gold plated contacts Load level Current type Load type Max. permitted constant current I (A) with Us (V) 24 60 5 250 Normal (f. ex. AC ohmic 15 15 15 15 contactor, solenoids) AC inductive, cos ϕ Ÿ 0,7 4 2,5 1,5 0,9 Minor (f. ex. electronic AC inductive spark quenching with RS contact 6 4 2,5 1,5 switching circuit) DC ohmic 2 0,9 0,45 0,2 DC inductive, L/R = 10 ms 1 0,3 0,09 0,02 DC inductive, spark quenching with diode 1,5 0,7 0,35 0,15 Reference number: 30/min Reference temperature: +30 C (with a reference temperature of + 70 C, Imax corresponds to 50% of the tabulated values only) Imax = 1.5 x Imax table Contact-life appr. 1 x 10 6 switching cycles at max. current (at 50% of max. current, contact life is appr. 3 times as long) Mechanical life appr. 5 x 10 6 switching cycles For non-aggressive atmosphere, which in particular does not contain any sulphur, the following limits are valid: Microswitch with silver contacts (standard): Umin ca. 8... V, lmin ca. 10 ma Maximum values acc. to table above. Microswitch with gold-plated contacts: Umin and Imin: No lower limit Sensible upper limit: Umax ca. 48 V, lmax ca. 20 ma; (for higher values silver spring contacts are completely sufficient). Proposal for spark extinction with direct voltage 1. Diode D parallel to the inductive load. Observe correct polarity with connection (positive pol at cathode). Dimensioning specificatons for erasing diode: Nominal voltage of the diode UD 1,4 Us. Nominal current of the diode IN ILast Select fast switching diodes (blocking recovery time trr 200 ms) 2. RC element parallel to the load (or parallel to the switching contact). Suitable for direct voltage and alternating voltage. Dimensioning principles: R in Ÿ 0,2 x RLoad in W C in µf Ÿ RLoad in A + (AC) Creepage and air paths correspond to insulation group B according to VDE Reg. 0110 (except contact clearence of microswitch). U S p R Last D R - (AC) I Last C N/UK 5.11.025.03

Basic dimensions 115,5 19 5,8 104 81 C 70 5 1 19 44 1 M4 x 10 deep ➀ 72,5 32 26 ø 45,5 ø 53 Electrical connector M20 x 1,5 acc. to DIN 46320 ca. 27 M 20 x 1,5 6 ø 5-8 N/UK 5.11.025.04 Our policy is one of continued research and development. We therefore reserve the right to amend, 6/06

Mounting (2 brackets and 4 screws) Steel Type: 0574772 Stainless Steel1.4301 (AISI 304) Type: 0553908 141 9 104 Surge damper Stainless steel 1.4301 (AISI 304) Type: 0553258 Brass/steel Type: 0574773 Stainless steel 1.4301 (AISI 304) Type: 0551894 46 27 45 ø 21,5 34 ø 6 5 20 Pressure port adaptors G1/2... 1/2 NPT Stainless steel 1.4305 (AISI 303/304 S) Type: 0553831 G1/4... G1/2 Stainless steel 1.4305 (AISI 303/304 S) Type: 0550083 G1/4 to G3/8 Steel Type: 0574764 G1/4 to 1/4 NPT Brass Type: 0574765 G1/4 27 1/2 NPT,5 14 3 5,8 118,5 G 3/8 ø21,5 13 36 1/4 NPT ø 20 6,5 30 N/UK 5.11.025.05