NivuBar Plus II

Similar documents
Hydrostatic Level and Pressure Measurement

Expert Hydrostatic Level Transmitters

Hydrostatic. Continuous level measurement. Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 AL-EN

MJK Expert 700 / 800 / 900 / 7070 / 7060 MJK Expert 1400 / 3400

OPTIBAR P 1010 C Technical Datasheet

LEVEL Transmitters. ) of the liquid column above it and the atmospheric pressure (P atm

High-performance submersible pressure transmitter For level measurement Model LH-20

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

High-performance submersible pressure transmitter For level measurement Model LH-10

SITRANS P measuring instruments for pressure

L (up to 25 m) Electronic part. working temp.: Ñ IP 66 / IP67. Mounting bracket ÐÑ. Sensor type. working temp.:

ATM.1ST/Ex - High Precision Transmitter

High-performance submersible pressure transmitter For level measurement Model LH-10

9700 Transmitter Submersible hydrostatic level transmitter

High-performance submersible pressure transmitter For level measurement Model LH-20

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

Pressure Measurement Single-range transmitters for general applications

Hidrostatic Level DATASHEET

High-performance submersible pressure transmitter For level measurement Model LH-20

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

ATM.ECO/IS - Analog Transmitter with Temperature compensation

x act i Precision- Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

Pressure Measurement Single-range transmitters for general applications

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

Picture. Minimum cable bending radius 100 mm [4"] < 400 N [90 lbf] (PE / PUR cables) < 15 N [3.4 lbf] (FEP cables)

TEK-SUB 4800B. Submersible Level Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys LEVEL

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

JUMO dtrans p30 Pressure Transmitter

Parametrable / Programmable Pressure Transmitter

Programmable pressure and temperature transmitters PTM/RS485

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

C-Flow Coriolis Mass Flow Meters

BSP Pressure Sensor Balluff GmbH, BA Marco Zorcic.

ATM.ECO - Analog Pressure Transmitter

Pressure Switches Application Guideline

Programmable Submersible Level Transmitters

3.0 Pressure Transmitter Selection

Gas density monitor With integrated transmitter Model GDM-100-TI

Programmable pressure and temperature transmitters PTM/RS485

ATM.1ST. Pressure transmitters CUSTOMER BENEFITS

Submersible pressure sensor High-performance Model LH-20

Hydrostatic Level Measurement waterpilot FMX 160

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Series INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN

SITRANS. Pressure transmitter SITRANS P, Z series for gauge and absolute pressure. Introduction. Safety instructions 2.

ED 701 Hygenic Pressure Transmitter

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

A Higher Level of Performance. Data Sheet. Series Pressure and Level Transmitters. For more information, please visit >

ATM - Analog Pressure Transmitter

Pressure Transmitters 36 F-27839

ATM/Ex - Analog Pressure Transmitter

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

200A Series ELECTRONIC LEVEL TRANSMITTER

Mobrey 9700 Transmitter Submersible Hydrostatic Level Transmitters

Differential Pressure Transmiter

Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

Hydrocont B Hydrostatic filling level sensor 40mm

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Pressure Measurement Single-range transmitters for general applications

Level transmitter LT 100

Ceramic Pressure Sensor

Level transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

Type S-10, S-11 General Purpose Pressure Transmitters

ATM/Ex - Intrinsically Safe Analog Pressure Transmitter - ATEX / IECEx Certified

L3 Pressure and Level transmitter

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

T EK-SUB 4800C 19 mm Submersible Level Transmitter

Series INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN

Inductive Linear Displacement Transducers Model IW 260 Measuring strokes: 80 mm, 170 mm, 240 mm, 360 mm

Ultrasonic. 58 Overview VEGASON 60 VEGASON 61, 62, 63

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Thermal flow sensor TA Di with integrated transducer for measuring mass flow, standard flow rate and air / gas consumption

Ultrasonic level transmitter and indicator

Operating Instructions for Intrinsically Safe Pressure Transmitters Series DMG/******** for Hazardous Application in Coal Mining Industry

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

SPD310/SPD360 Air Differential

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Cable entries. Contents. Cable entries. Cable entries Introduction L.2 L.1. Standard cable glands - Plastic L.5. Standard cable glands - Brass L.

JUMO MAERA. Level probes Types , , , Installation Instructions T94Z001K000 V4.00/EN/

Mechanical Pressure Switches for overpressure, vacuum pressure and differential pressure

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Level switches Series LD Vibrating fork level switch for liquids and solids

dtrans O2 01 Two-wire Transmitter for dissolved oxygen (DO)

Pressure transmitters EMP 2

Level switches Series LD Vibrating fork level switch for liquids and solids

Vortex Flow Sensor VA Di Ex-d for flow measurement in gases; with integrated, configurable transducer UVA in Ex-d housing

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor

JUMO dtrans O2 01 Two-wire Transmitter for dissolved oxygen (DO)

Differential pressure

EX-RECESSED CEILING LIGHT FITTINGS

MB260/MB261/MB264 Submersible Level Transmitter

Transcription:

NivuBar Plus II Ceramic diaphragm Capacitive measuring cell 2-wire technology (output 4-20 ma) Integrated overload protection Extensive, almost front flush diaphragm Ex approval for zone 0 as standard NivuBar Plus II Zone 0 NivuBar Plus II with integrated 4-20 ma transmitter for hydrostatic level measurement in water and waste water. With capacitive ceramic measuring cell without oil filling. H:\NBPlusr\nb-db-en.cdr / Rev. 02-18.06.2012 This hydrostatic level probe is developed to meet the high demands of industrial and environmental protection. The stainless steel probe body is locked by a capacitive ceramic measuring cell at the bottom and is held by the selfsupporting cable on the top. The probe can be suspended e.g. on manhole walls by using a straining clamp. The non-corrosive enclosure with ingress protection IP68 (NEMA 6X) permits universal use for reliable determination of levels in containers, basins, pump stations and tanks. The extensive diaphragm has proven as very reliable, particularly in the sewage environment. The Ex-approval II 1G Ex ia IIC/IIB T4 is standard and the NivuBar Plus II therefore can be installed in all explosive surroundings. Utilising the widely used 2-wire technology, the installation costs are very low. Phone: 49 (0)7262 9191-0 Fax: 49 (0)7262 9191-999 E-mail: info@nivus.com

NivuBar Plus II and connection Measurement range Power supply Output signal Accuracy according to IEC 60770 Long-term stability Electric connection Load 1, 2, 4, 6, and 10 m water column special measurement ranges on request 12 to 36 V DC, Ex: 12 to 28 V DC 4-20 ma, 2-wire technology 0.25 % / 0.35 % FSO ± 0.1 % FSO / year free cable end 600 Ohm / 24 V 1000 Ohm / 32 V Integrated overvoltage protection -120 to 150 V DC (1 sec at 25 C) Operating temperature -10 C to 70 C Storing temperature -25 C to 70 C Material diaphragm: ceramic (Al2O 3) enclosure: stainless steel 1.4571 sealing: Viton cable: ø9 mm Polyurethane Cable length 10, 20, 30, 50, 100 m special length on request Protection IP68 Measuring principle capacitive Ex-approval II 1G Ex ia IIC/IIB T4 IBEx U05 ATEX 1193X Accessories Terminal clamp AKL 1, stainless steel 1.4571 Locking sleeve (carrier) G1.5", stainless steel, as holder for NivuBar Plus II probe Connector box KLB2 with overvoltage protection and pressure compensation; material: Plastic Junction box BPG Ex with pressure compensation Surge arrestor Type 9001/51-280-091-141 ATEX for connection to SPS in zone 1 Protective cap PUR cable blue, ø9mm Diaphragm red - blue PVC tube with PE filter for pressure reference shield/pe-earth green/yellow 3 129 Viton is a registered trademark of DuPont Dow Elastomers You can find more information in the instruction manual or on www.nivus.com 17.5 ø39.5 Connection P I red blue 2-wire: 4...20mA A Supply 12...36 V DC 12...28 V DC - Supply GND = PE H:\NBPlusr\nb-db-en.cdr / Rev. 01-18.06.2012 Phone: 49 (0) 7262 / 9191-0 Fax: 49 (0) 7262 / 9191-999 E-mail: info@nivus.com

NivuBar H II Ceramic diaphragm Capacitive measuring cell 2-wire technology (output 4-20 ma) Integrated overload protection Extensive, almost front flush diaphragm Independent measurement range setting via HART interface Ex approval for zone 0 (optional) NivuBar H II R H A R T Zone 0 NivuBar H II with integrated 4-20 ma transmitter for hydrostatic level measurement in water and waste water. With capacitive ceramic measuring cell without oil filling and independent measurement range setting via HART interface. H:\NBH\nbh-db-en.cdr / Rev. 02-03.04.2013 This probe is developed to meet the high demands of industrial and environmental protection. The stainless steel probe body is locked by a capacitive ceramic measuring cell at the bottom and is held by the self-supporting cable on the top. The probe can be suspended e.g. on manhole walls by using a straining clamp. The non-corrosive enclosure with ingress protection IP68 (NEMA 6X) permits universal use for reliable determination of levels in containers, basins, pump stations and tanks. The extensive diaphragm has proven as very reliable, particularly in the sewage environment. The probe is also available with Exapproval and therefore can be installed in all explosive surroundings. Via the HART protocol the measurement range of the probe can be set universally. This is done via a laptop with the NIVUS Configuration Software and the HART interface converter. The Measurement range is adjustable until 20 m water column. This enables a low set limit of 20 % in relation to the stated measurement range (FSO) of the probe e.g. 0 to 2 m or 4 to 6 m. Utilising the widely used 2-wire technology, the installation costs are very low. Phone: 49 (0)7262 9191-0 Fax: 49 (0)7262 9191-999 E-mail: info@nivus.com

NivuBar H II ø9 Measurement range 0 to 20 m water column lowest range: 20% of measurement value adjustable via HART special measurement ranges on request Power supply 12 to 36 V DC, Ex: 12 to 28 V DC Output signal 4-20 ma, 2-wire technology Accuracy according to IEC 60770 0.1 % FSO Long-term stability ± 0.1 % FSO / year Electric connection free cable end Load 600 Ohm / 24 V 1000 Ohm / 32 V Integrated overvoltage protection -120 to 150 V DC (1 sec at 25 C) Operating temperature -10 C to 70 C Storing temperature -25 C to 70 C Material diaphragm: ceramic (Al2O3) enclosure: stainless steel 1.4571 sealing: Viton cable: ø9 mm Polyurethane Cable length 10, 20, 30, 50, 100 m special length on request Protection IP68 Measuring principle capacitive Ex-approval (optional) FTZÚ 06 ATEX 0027X II 1GD Ex ia IIB/IIC T4 T85 C Accessories Terminal clamp AKL 1, stainless steel 1.4571 Locking sleeve (carrier) G1.5", stainless steel, as holder for NivuBar Plus II probe Connector box KLB2 with overvoltage protection and pressure compensation; material: Plastic Junction box BPG Ex with pressure compensation Surge arrestor Type 9001/51-280-091-141 ATEX for connection to PLC in zone 1 HART interface module for connection to PC via RS232 (interface converter) interface HART configuration on CD ROM software HART-Modul HAM-300, adapter module for integration into ma loop Protective cap Diaphragm 3 17.5 200 Viton is a registered trademark of DuPont Dow Elastomers ø39.5 You can find more information in the instruction manual or on www.nivus.com Connection P I red blue 2-wire: 4...20mA A Supply 12...36 V DC 12...28 V DC - Supply GND = PE H:\NBH\nbh-db-en.cdr / Rev. 02-03.04.2013 Phone: 49 (0)7262 9191-0 Fax: 49 (0)7262 9191-999 E-mail: info@nivus.com

AquaBar Stainless steel diaphragm Piezoresistive measuring cell 2-wire technology (output 4-20 ma) Integrated overload protection High accuracy High electrical operational reliability AquaBar AquaBar with integrated 4-20 ma transmitter for hydrostatic level measurement in clear to slightly polluted fluids. H:\AquaBar\ab-db-en.cdr / Rev. 02-13.02.2012 The diameter of only 27mm allows to use the AquaBar in stand pipe applications which are mainly used in ground water level measurement and deep well measuring. The proven piezoresistive measurment principle ensures high long-term stability and operational reliability. The AquaBar is highly resistant against electrical faults caused by incorrect wiring, short circuit and overvoltage. The robust probe enclosure is made of 1.4571 stainless steel with a 1.4435 stainless steel diaphragm. It is held by a self-supporting PUR cable. The probe can be suspended e.g. on manhole walls by using a straining clamp. Utilising the widely used 2-wire technology, the installation costs are very low. Special measurement ranges and customised versions are available on request. Phone: 49 (0)7262 9191-0 Fax: 49 (0)7262 9191-999 E-mail: info@nivus.com

AquaBar ø9 Measurement range 4, 6, und 10 m water column special measurement ranges on request Power supply 12 to 36 V DC Output signal 4-20 ma, 2-wire technology Accuracy according to IEC 60770 0.35 % FSO Long-term stability ± 0.1 % FSO / year Electric connection free cable end Load 600 Ohm / 24 V 1000 Ohm / 32 V Integrated overvoltage protection -120 to 150 V DC (1 sec at 25 C) Operating temperature -10 C to 70 C Storing temperature -25 C to 70 C Material diaphragm: stainless steel 1.4435 enclosure: stainless steel 1.4571 sealing: Viton cable: ø9 mm Polyurethane Cable length 10, 20, 30, 50, 100 m special length on request Protection IP68 Measuring principle piezoresistive Accessories Straining clamp AKL 1, stainless steel 1.4571 Pressure compensation for junction boxes, not submersible Junction box IP65 with pressure compensation 124.5 Viton is a registered trademark of DuPont Dow Elastomers You can find more information in the instruction manual or on www.nivus.com Protective cap ø27 Connection P I red blue 2-wire: 4...20mA A Supply 12...36V DC - Supply GND = PE H:\AquaBar\ab-db-en.cdr / Rev. 02-13.02.2012 Phone: 49 (0)7262 9191-0 Fax: 49 (0)7262 9191-999 E-mail: info@nivus.com

AquaBar BS Stainless steel diaphragm Piezoresistive measuring cell 2-wire technology (output 4-20 ma) Integrated overload protection Probe diameter only 19mm Suitable for 1" pipes AquaBar BS AquaBar BS with integrated 4-20 ma transmitter for hydrostatic level measurement in wells, open water bodies and for ground water level measurement. H:\AquaBar_BS\ab-bs-db-en.cdr / Rev. 01-21.06.2008 An outside diameter of only 19 mm enables the probe to be used even in 1" protective pipes. The probe can be used in all media which are consistent with stainless steel and PUR. The piezoresistive pressure pickup guarantees high accuracy and longterm stability. The probe operates in 2-wire technology (4-20mA). An integrated overvoltage and polarity protection ensures high electric operational reliability. On request the probes can be manufactured according to conditions specified by the customer. For probe mounting straining clamps and connection boxes with integrated pressure compensation are available. Phone: 49 (0)7262 / 9191-0 Fax: 49 (0)7262 / 9191-999 E-Mail: info@nivus.com

AquaBar BS Measurement range 4, 6, 10 and 20 m water column special measurement ranges on request Power supply 12 to 36 V DC Output signal 4-20 ma, 2-wire technology Accuracy according to IEC 60770 0.35 % FSO Long-term stability ± 0.1 % FSO / year Electric connection free cable end Load 600 Ohm / 24 V 1000 Ohm / 32 V Integrated overvoltage protection -120 to 150 V DC (1 sec at 25 C) Operating temperature -10 C to 70 C Storing temperature -25 C to 70 C Material diaphragm: stainless steel 1.4435 enclosure: stainless steel 1.4571 sealing: Viton cable: ø7.4 mm Polyurethane Cable length 10, 20, 30, 50, 100 m special length on request Protection IP68 Measuring principle piezoresistive Accessories Straining clamp AKL 1, stainless steel 1.4571 Pressure compensation for junction boxes not submersible Junction box IP65 with pressure compensation Viton is a registered trademark of DuPont Dow Elastomers ø7.4 135 (123.5 without p rotective cap ) You can find more information in the instruction manual or on www.nivus.com Protective cap ø19 Connection P I white brown 2-wire: 4...20mA A Supply 12...36V DC - Supply GND = PE H:\AquaBar_BS\ab-bs-db-en.cdr / Rev. 01-21.06.2008 Phone: 49 (0) 7262 / 9191-0 Fax: 49 (0) 7262 / 9191-999 E-mail: info@nivus.com

HydroBar G II Screw-in probe Ceramic diaphragm Capacitive measuring cell 2-wire technology (output 4-20 ma) Integrated overload protection High accuracy High electric operational reliability Ex approval for zone 0 (optional) HydroBar G II zone 0 HydroBar G II Screw-in probe with integrated 4-20 ma transmitter for hydrostatic level measurement in clear fluids, sludges and gases. The probes are particularly suitable for level investigation in tanks, containers and pipe lines. H:\HBG\hg-db-01-dt.cdr / Rev. 02-25.02.2013 Due to the large front-flush diaphragm and the G1½ connection the probe has particularly proven in the wastewater area. The unit is designed for flush installation, allowing to use it even in viscous liquids. There is no possibility of failures caused by sediments at the membrane therefore. The HydroBar G II can be used in aggressive media such as acids and caustic solutions as well. Measuring in these extreme operating conditions is possible by using a capacitive ceramic gauge head made of 96%- Al O. 2 3 The probe is also available with Exapproval II 1G Ex ia IIC/IIB T4. The HydroBar G II has a fixed measurement range and utilises proven 2-wire technology. Optionally available is a 4-character LED display integrated in the enclosure lid. Phone: 49 (0)7262 / 9191-0 Fax: 49 (0)7262 / 9191-999 E-Mail: info@nivus.com

HydroBar G II Screw-in probe Screw-in probe Measurement range / 1 mwc / 2 bar I 2 mwc / 2 bar overpressure 4 mwc / 4 bar I 6 mwc / 4 bar 10 mwc / 7 bar I 20 mwc / 10 bar 1 bar / 7 bar I 2 bar / 10 bar 4 bar / 25 bar I 6 bar / 25 bar 10 bar / 40 bar I 20 bar / 60 bar ø59.5 57.5 Special measurement ranges on request Power supply 12 to 36 V DC, Ex: 12 to 28 V DC Output signal 4-20 ma, 2-wire technology Accuracy according to IEC 60770 0.25 % / 0.35 % FSO Long-term stability ± 0.1 % FSO / year Electric connection M16 x 1.5 (for cable 4 to 11 mm) Process connection G1½ DIN ISO 228 Load 600 Ohm / 24 V 1000 Ohm / 32 V Integrated overvoltage protection -120 to 150 V DC (1 sec at 25 C) Operating temperature -25 C to 85 C (electronics) Temperature of measured substance -25 C to 125 C Storing temperature -40 C to 100 C Material field enclosure stainless steel 1.4305 Medium-contacting diaphragm: ceramic Al 2 O 3 pressure conn. stainless steel 1.4571 sealing: Viton Protection IP67 Measuring principle capacitive Ex-approval (optional) II 1G EEx ia IIC/IIB T4 IBEx U05 ATEX 1193X Mechanical strength vibration: 10 g RMS (20...2000 Hz) shock: 100 g/11 ms Accessories Surge arrestor Type 9001/51-280-091-141 ATEX for connection to PLC in zone 1 Viton is a registered trademark of DuPont Dow Elastomers (113 / 137.5*) 22 91 (115.5*) G1½ * of probe with LED display. 2-wire: 4...20mA ø26.5 28 (52.5*) M16 x 1.5 ø65 Width across flats 55 P I A 12...36 V DC 12...28 V DC Supply U B - Supply You can find more information in the instruction manual or on www.nivus.com H:\HBG\hg-db-01-dt.cdr / Rev. 02-25.02.2013 NIVUS GmbH Im Täle 2 D-75031 Eppingen Internet: www.nivus.de Tel.: 49 (0) 7262 / 9191-0 Fax: 49 (0) 7262 / 9191-999 E-mail: info@nivus.com

UniBar E Screw-in probe Stainless steel diaphragm Piezoresistive measuring cell 2-wire technology (output 4-20 ma) Integrated overload protection High accuracy High electric operational reliability Ex approval for zone 0 (optional) UniBar E Zone 0 UniBar E Screw-in probe with integrated 4-20 ma transmitter for hydrostatic level measurement in clear fluids and gases. The probes are particularly sufficient for level investigation in tanks, containers and pipe lines. H:\UniBar_E\ube-db-01-en.cdr / Rev. 04-25.06.2014 The unit comes with a G1/2 connection (DIN 3852) as standard process connection. The electric connection is made by screw terminals in stainless steel enclosure or plugs according to DIN ISO 4400. Various standard measurement ranges are available. The probes can be calibrated to the customer's individual requirements on request. UniBar E probes are designed for rough industrial use. The UniBar E has proven even in aggressive media such as acids, lye and bleach. The use under such extreme conditions is possible by using piezoresistive measurement cells made of stainless steel (1.4404). The probe is also available with Exapproval II 1G Ex ia IIC/IIB T4 and therefore can be installed in all explosive surroundings. The UniBar E has a fixed measurement range. The probe utilises 2-wire technology. Optionally available is a 4-character LED display integrated in the enclosure lid. Phone: 49 (0)7262 9191-0 Fax: 49 (0)7262 9191-999 E-mail: info@nivus.com

UniBar E Screw-in probe ø59.5 ca. 60 approx. 33 M16 x 1.5 65.5 (89*) 48.5 (**75) 14 ø26.5 G½ Width over flats of hexagonal nut SW27 * of the probe with LED display ** of the Ex type probe (93.5/113.5*) 14 46.5 (66.5*) 33 ø26.5 G½ PG9 Plug according to DIN ISO 4400 ø35 ** of the Ex type probe Connection Connection P I A 12...36 V DC 14...28 V DC Supply U B - Supply DIN 4400 PIN 1 = Supply PIN2 = Supply - PIN3 = not connected GND = PE Screw-in probe Measurement range/ 1 mwc / 1 bar I 2 mwc / 1 bar overpressure 4 mwc / 1 bar I 6 mwc / 3 bar 10 mwc / 3 bar I 20 mwc / 6 bar 1 bar / 3 bar I 2 bar / 6 bar 4 bar / 20 bar I 6 bar / 20 bar 10 bar / 20 bar I 20 bar / 90 bar Special measurement ranges on request. Power supply 12 to 36 V DC, Ex: 14 to 28 V DC Output signal 4-20 ma, 2-wire technology Accuracy according to IEC 60770 0.25 % / 0.35 % FSO Long-term stability ± 0.1 % FSO / year Electric connection field enclosure M16 x 1.5 / plug PG 9 Process connection G½ DIN 3852 open connection with 12 mm diameter Load 600 Ohm / 24 V or 1000 Ohm / 32 V Integrated overvoltage protection Operating temperature -120 to 150 V DC (1 sec at 25 C) -25 C to 85 C (electronics) Temperature of measured substance -25 C to 125 C Storing temperature -40 C to 100 C Material field enclosure stainless steel 1.4404 (inox 316L) with cable gland made of nickel-plated brass plug enclosure stainless steel 1.4404 (inox 316L) Medium-contacting diaphragm: stainless steel 1.4435 (inox 316Ti) pressure conn. stainless steel 1.4571 sealing: Viton Protection field enclosure IP 67; plug IP 65 Measuring principle piezoresistive Ex-approval (optional) II 1G Ex ia IIC T4; ATEX 2011X Mechanical strength vibration: 10 g RMS (20...2000 Hz) shock: 100 g/11 ms Accessories Surge arrestor type 9001/51-280-091-141 ATEX for connection to SPS in Zone 1 PA430 plug-on display 4-20 ma; LED; self-supplied via UniBar E plug connector PA430-Ex see above for Ex zone 1 Viton is a registered trademark of DuPont Dow Elastomers H:\UniBar_E\ube-db-01-en.cdr / Rev. 04-25.06.2014 Phone: 49 (0) 7262 / 9191-0 Fax: 49 (0) 7262 / 9191-999 E-mail: info@nivus.com You can find more information in the instruction manual or on www.nivus.com

Pressure and Level Probes Overview Submersible Probes NivuBar Plus II ø39.5 mm NivuBar H II ø39.5 mm NivuBar G II ø39.5 mm Diaphragm ceramics Meas. principle capacitive Ex approval zone 0 Medium water, wastewater Meas. range 1, 2, 4, 6, 10 m WC Fastening suspend on cable Diaphragm ceramics Meas. principle capacitive Ex approval zone 0 (optional) Medium water, wastewater Meas. range 0-20 m WC free adjustable Fastening suspend on cable Diaphragm ceramics Meas. principle capacitive Ex approval zone 0 Medium water, wastewater Meas. range 1, 2, 4 m WC Fastening 1 thread at probe bottom level monitoring in open tanks at low fill levels depth measurement in wells and open water bodies ground water level measurement sewage works, water processing level monitoring in open tanks at low fill levels depth measurement in wells and open water bodies ground water level measurement sewage works, water processing level monitoring in open tanks at low fill levels open water bodies ground water level measurement sewage works, water processing Pressure and Level Probes AquaBar ø27 mm AquaBar BS ø19 mm Screw-In Probes Diaphragm stainless steel Meas. principle piezo-resistive Medium water, wastewater Meas. range 2, 4, 6, 10 m WC Fastening suspend on cable Diaphragm stainless steel Meas. principle piezo-resistive Medium water Meas. range 4, 6, 10, 20 m WC Fastening suspend on cable environmental technology: water processing, sewage works depth measurement in wells and open water bodies ground water level measurement level monitoring in open tanks depth measurement in wells and open water bodies ground water level measurement level monitoring in open tanks H:\Druck\du-db-en.cdr / Rev. 02-28.03.2013 HydroBar G Diaphragm ceramics Meas. principle capacitive Ex approval zone 0 (optional) Medium liquids, sludge, gas Meas. range 1, 2, 4, 6, 10, 20 m WC Fastening G1½ thread UniBar E Diaphragm stainless steel Meas. principle piezo-resistive Ex approval zone 0 (optional) Medium liquids, gas Meas. range 1, 2, 4, 6, 10, 20 m WC Fastening G½ thread level measurement in closed tanks and pipes environmental technology: water processing, sewage works level measurement in closed tanks and pipes environmental technology sewage works pneumatics / hydraulics process technology and engineering Phone: 49 (0)7262 9191-0 Fax: 49 (0)7262 9191-999 E-mail: info@nivus.com