Ambient Weather GL150-TH Nautical Thermometer Hygrometer (ComfortMeter) User Manual

Similar documents
Ambient Weather GL152-TT Marine Time and Tide Clock User Manual

Ambient Weather GL150-B Nautical Barometer User Manual

Ambient Weather TIDECLOCK-25 6" Nautical Brass Quartz Time and Tide Clock with Bayonet User Manual

Fischer 1588GU-22 Brass Tide Clock and Ship's Bell with Wood Plaque User Manual

Fischer 1605GU /8" Solid Brass Nautical Quartz Tide and Time Clock User Manual

Fischer Instruments 103PMTD 6" Navigator Series Tide Clock User Manual

Ambient Weather WS-03 Thermo-Hygrometer

Ambient Weather TransformaFence User Manual

CONTENTS A. BEFORE USING B. SETTING THE TIME AND CALENDAR C. FUNCTIONS OF SOLAR POWERED WATCH

NOVALYNX CORPORATION MODEL WEATHER STATION INSTRUCTION MANUAL

Advanced Test Equipment Rentals ATEC (2832)

Digital Melting Point Apparatus

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

Product Specifications Specialty Junction Boxes

CONTENTS 1. Features 7. Solar-Powered Watch Handling Precautions 2. Before Using 3. Names of Components

HOME BLOOD PRESSURE KIT INSTRUCTIONS TRILINGUAL INSTRUCTION GUIDE MODEL UA-100

CSA Sample Draw Aspirator Adapter Operator s Manual

S A X O N A U T O M AT I C

Notes Before Use...2 Notes on charging your watch...2. Your Watch...4 Name of Components...6 About the crown...7

Sample Concentrator SBH CONC/1 Instructions for use

Model 106 DPI "Micro-switch" Installation and Operating Instructions

ATEX ATEX

GAS STRUT SAFETY INFORMATION

NOTES TABLE OF CONTENTS

BEFORE USING B. SETTING THE TIME AND CALENDAR C. FUNCTIONS OF SOLAR POWERED WATCH

User s Manual. USB Golf Simulator. Contents

Beeman Precision Airguns R-Series Air Rifle Owner s Manual

Owner s Manual High Density Sports Storage Partial End Closure Accessory 32-inch Partial End Closure 48-inch Partial End Closure

ROPV R40 E Series User Manual

WIKA INSTRUMENT CORPORATION

Psyclone TM. Protimeter Thermo-Hygrometer. GE Sensing. Operating Manual. INS7800, Rev. A (September 2007)

Owner s Manual Humiport 10/20

1. Features CONTENTS. English

INSTRUCTIONS warranty watch care

GE Measurement & Control

Operation Manual. O2 Quickstick. Oxygen Analyzer 08.17

WARNING NOTES TABLE OF CONTENTS

Operation Manual. O2 Quickstick. Oxygen Analyzer

FLANGED TWO-PIECE BALL VALVES

GasLab SAN-102 Micro Oxygen Monitor User Manual

Inflatable Stand Up Paddle Board Manual

CastCreations PRODUCT DESCRIPTION. Redwood Stump Fire Pit Item #: C1002. CastCreations Ph: Aurora, Utah

Please make sure to check the following before use.

AND OPERATION INSTRUCTIONS

DB 61 Dolphin TMV3 Integrated Thermostatic Mixing Valve

PURA. Pure Gas Dewpoint Transmitter. Users Guide

TD-106-5D TD-106-5D-A Wind Direction Sensor User s Manual

Eaton Filtration, LLC

Modular skylight warranty

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100

Installation, Operation & Maintenance Manual

FLANGED TWO-PIECE BALL VALVES

HYGRODYNAMICS NARROW RANGE HYGROSENSOR CONTENTS

NOVALYNX CORPORATION MODEL RAIN GAUGE CALIBRATOR INSTRUCTION MANUAL

Instrument Operating Manual

Monster Windy City Leopard

! Warning, refer to accompanying documents.

Part I - Installation

USER MANUAL

with O 2 Controller Instruction Manual

RADROVER REAR RACK INSTALLATION MANUAL

Regulator for 2 MPa ARX 20. How to Order. Bracket. Pressure gauge. Port size 1/8 1/4. Panel nut

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Dial Adjustment)

Operating Manual Body fat balance

Simrad GD10P Extended On-site Maintenance

Bourdon tube pressure gauges for chemical applications EN 837-1

High Precision Gauge Pressure Indicators

Veriforce TG CCT 609OP. Training Guide

Safety instructions and operating manual

U S E R M A N U A L AIR FLOWMETER. MODELS: 1MFA2001 (shown) 1MFA9001 CAUTION. ISO Certified

Bourdon tube pressure gauges with glycerine filling, for chemical applications EN 837-1

Installation & User Guide. English Version 1.0

Installation and Maintenance Instruction Manual

RK-IR Sample Draw Aspirator Adapter Operator s Manual

InstallatIon and owner s InstrUCtIons

Operating Manual. Models AQT-02 & AQT-COO2 Manual No. MON004 (Rev 2 April 2000)

92831 TEL: (714) FAX:

ENGLISH FRANÇAIS ESPAÑOL DEUTSCH ITALIANO PORTUGUÊS

Request to Customers All repairs performed on this watch, excluding repairs involving the band, are to be performed at the CITIZEN.

ACRYLIC FLOW METERS 0-30, 0-70 & LPM

RK LEL Sample Draw Aspirator Adapter Operator s Manual

1. Features CONTENTS. 3English

EASIDEW TRANSMITTER with Current Source Output

Crown Operation Models Equipped with a Crown Cover

1. Features. 3English

M3-LED. Operator s Manual. Operator s Manual MADE IN THE USA USA

Instruction Manual / Glide. Richie Vas / Maxum Team MMA Bantamweight Champion & Big Wave Surfer

Thank you for your purchase of this Citizen watch. Before using the watch, read this instruction manual carefully to ensure correct use.

Congratulations on your purchase of a JC Series Performer trike! The Performer JC Series is designed for everything from touring to commuting and

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

RAM 4021 Operation Manual

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

600 / 600FC OWNER'S MANUAL

In Vivo Scientific, LLC INSTRUCTION MANUAL

Pressure measurement. Pressure gauges

PM105 PRESSURE METER USER S MANUAL

GALISO SOAP OPTION FOR PCT-ADW-D

S&S. Installation Instructions: S&S Stealth Air Cleaner Kit for Harley-Davidison Models With Stock Cable Operated Delphi EFI

Transcription:

Ambient Weather GL150-TH Nautical Thermometer Hygrometer (ComfortMeter) User Manual Table of Contents 1. Introduction... 2 2. Care and Cleaning... 2 3. Installation... 2 4. ComfortMeter... 4 4.1 How the hygrometer works... 4 4.2 Hygrometer Accuracy... 4 4.3 Dial Thermometer... 4 5. Water Resistant and Corrosion Proof Specifications... 5 6. Warranty Information... 5 7. Liability Disclaimer... 5 Version 1.0 Copyright 2011, Ambient LLC. All Rights Reserved. Page 1

1. Introduction Thank you for your purchase of the Ambient Weather GL150-TH ComfortMeter. The following is a guide for preparation, care and operation of your marine weather instrument. Note: Some of the images are generic and may not match your exact model. 2. Care and Cleaning Avoid use of harsh household cleaners and coarse paper towels, which can scratch the bezel or lens. Fingerprints and dirt may be removed the lenses and bezels with a soft cloth lightly dampened with a mixture of water and mild dishwashing liquid. Be sure to dry the lens and bezel with a soft cloth after cleaning. 3. Installation 1. Turn the blackplate counter clockwise (Figure 1) and remove the back to expose the backplate, as shown in Figure 2. Figure 1 Figure 2 2. Fix the backplate to a wall or plaque (optional) with the four mounting screws (included) as shown in Figure 2. 3. Connect the instrument to the backplate and insert the lug on the backplate to align with the gap on the instrument panel. The instrument will be aligned about 30 degrees counterclockwise, as shown in Figure 3. Version 1.0 Copyright 2011, Ambient LLC. All Rights Reserved. Page 2

Figure 3 4. Turn the instrument panel clockwise until it no longer rotates, as shown in Figure 4. The instrument panel will now be vertically aligned, as shown in Figure 5. Figure 4 Figure 5 Version 1.0 Copyright 2011, Ambient LLC. All Rights Reserved. Page 3

4. ComfortMeter Figure 6 The calibration and positioning of the hands are designed to indicate perfect comfort conditions in room atmosphere: when both hands cross in a limited area of the dial, or the COMFORT zone. 4.1 How the hygrometer works The hygrometer measures the indoor relative humidity. The sensor measures the air moisture by a sensitive mechanical coil spring that is bonded with a moisture absorbent material. Hygrometers register the percentage of water vapor present in the air, compared to the maximum amount that can be present at a given temperature. The coils in hygrometers respond slowly and while humidity levels change abruptly, it can take an hour or more for the meter to reach an accurate reading. Remember that the hygrometer is reading indoor humidity, and is vastly different than outdoor humidity, as reported by the National Weather Service. It is not uncommon to have low humidity reading during cold weather when indoor air is heater. Air conditioning also removes moisture from the air. The optimum levels are 45% to 50% during heating and cooling seasons. Low humidity can cause health problems and can be hard on wood furnishings. High humidity can cause mold or mildew to grow. 4.2 Hygrometer Accuracy Humidity measurement is among the more difficult problems in basic meteorology. Accuracy is difficult to achieve and are subject to drift, so need regular recalibration. A further difficulty is that most hygrometers sense relative humidity rather than the absolute amount of water present, but relative humidity is a function of both temperature and absolute moisture content, so small temperature variations within the air in a test chamber will translate into relative humidity variations. 4.3 Dial Thermometer The dial thermometer uses a bimetallic strip wrapped into a coil. One end of the coil is fixed to the housing of the device and the other drives an indicating needle. The principle behind a bimetallic strip thermometer relies on the fact that different metals expand at different rates as they warm up. By Version 1.0 Copyright 2011, Ambient LLC. All Rights Reserved. Page 4

bonding two different metals together, the coil bends, causing the needle to move. Bimetallic thermometers are not as accurate as bulb (mercury or red spirit) thermometers. The dial thermometer should require no calibration. 5. Water Resistant and Corrosion Proof Specifications This unit is water resistant with seals on the front and back of the unit and includes a 5 year warranty against corrosion. The manufacturing process includes double plating: Physical Vapor Deposition (PVD) Zirconium plating over Chromium plating. Zirconium is a metal which has a high hardness and melting point. It is corrosion resistant, and will never tarnish, discolor or scratch. The surface of Zirconium Coating has the color of brass, with a mirror, hand polished finish. The aluminous dial is suitable for various weather harsh conditions. High quality stainless steel mounting screws with PVD Zirconium plating are included. All fasteners are made of stainless steel, suitable for salt water environments. 6. Warranty Information Ambient, LLC provides a 5-year limited warranty on this product against manufacturing defects in materials and workmanship. This limited warranty begins on the original date of purchase, is valid only on products purchased and only to the original purchaser of this product. To receive warranty service, the purchaser must contact Ambient, LLC for problem determination and service procedures. Warranty service can only be performed by a Ambient, LLC. The original dated bill of sale must be presented upon request as proof of purchase to Ambient, LLC. Your Ambient, LLC warranty covers all defects in material and workmanship with the following specified exceptions: (1) damage caused by accident, unreasonable use or neglect (lack of reasonable and necessary maintenance); (2) damage resulting from failure to follow instructions contained in your owner s manual; (3) damage resulting from the performance of repairs or alterations by someone other than an authorized Ambient, LLC authorized service center; (4) units used for other than home use (5) applications and uses that this product was not intended, such as outdoor use. This warranty covers only actual defects within the product itself, and does not cover the cost of installation or removal from a fixed installation, normal set-up or adjustments, claims based on misrepresentation by the seller or performance variations resulting from installation-related circumstances. 7. Liability Disclaimer Reading the User manual is highly recommended. The manufacturer and supplier cannot accept any responsibility for any incorrect readings and any consequences that occur should an inaccurate reading take place. The specifications of this product may change without prior notice. This product is not a toy. Keep out of the reach of children. Version 1.0 Copyright 2011, Ambient LLC. All Rights Reserved. Page 5

No part of this manual may be reproduced without written authorization of the manufacturer. Ambient, LLC WILL NOT ASSUME LIABILITY FOR INCIDENTAL, CONSEQUENTIAL, PUNITIVE, OR OTHER SIMILAR DAMAGES ASSOCIATED WITH THE OPERATION OR MALFUNCTION OF THIS PRODUCT. Version 1.0 Copyright 2011, Ambient LLC. All Rights Reserved. Page 6