All Sixth Sense cells for toxic gas detection are based on electrochemical principles and can be classified as amperometric fuel cells.

Similar documents
Nemoto Sensor Engineering Company Ltd

Nemoto Sensor Engineering Company Ltd

OP08 - Electrochemical 3-Electrode Un-biased Toxic Sensors CONTENTS. Introduction 2. Operating Principles 2. Recommended Circuitry 4.

SPECIFICATION. date of manufacture. Intermittent: -20 o C to +50 o C. Pressure Range:

SPECIFICATION. date of manufacture. Intermittent: -20 o C to +50 o C. Pressure Range:

O3 3E 1 F Gas Sensor Module

Phosgene Sensor. Sensoric COCl2 3E 1

Ozone. Sensoric O3 3E 1

MODEL GT820 OXYGEN SENSOR

Electrochemical Sensor

ME3-HCL Electrochemical sensor

Electrochemical Carbon Monoxide Gas Sensor (Model:ME3-CO) Manual. Version 1.2 Valid from May 1 st 2014

Electrochemical Sensor

Technical Data Sheet MF010-O-LC

Application Note AN-107

OxiQuant S. Operating Instructions

Columbus Instruments

Dissolved Oxygen Guide

an ISO9001 company TECHNICAL INFORMATION FOR TGS5141 Technical Information for Carbon Monoxide Sensors

White Paper. Chemical Sensor vs NDIR - Overview: NDIR Technology:

Alphasense 4-20 ma transmitters offer convenience and easy maintenance for toxic sensors:

Operation and Maintenance Manual

an ISO9001 company TECHNICAL INFORMATION FOR SK-25F Technical Information for Figaro Oxygen Sensor SK-25F

Application Note Operating Principle and Construction of Zirconium Dioxide Oxygen Sensors

All P-Types, Trace Oxygen Sensors

O 2 SENSORS Zirconium Dioxide (ZrO 2 ) Oxygen Sensor Operating Principle Guide

Series 6517 Katharometers. The ideal equipment for Process Monitoring and Control. Robust no moving parts. Designed for continuous industrial use

Operating Instructions

Operating Characteristics and Handling Manual for the NAP-55A / NAP-50A Explosive/Flammable Gas Sensor NEMOTO

Calibration Requirements for Direct Reading Confined Space Gas Detectors

Transmitter CS 21 Operation Manual

Applications Note: Use of "pentane equivalent" calibration gas mixtures

Precision level sensing with low-pressure module MS

an ISO9001 company TECHNICAL INFORMATION FOR TGS5042 Technical Information for Carbon Monoxide Sensors

Sensoric 4-20 ma Transmitter Board Operation Manual

Dissolved Oxygen and measurement possibilities. Berno Lüpkes, 15 th March 2017

Operation manual Oxygen sensor

VHP Vaporized Hydrogen Peroxide monitoring GAS DETCTION SYSTENS. Dräger. Technology for Life

Specifications of Oxygen Sensor Module V-8344A

GENERAL INFORMATION FOR TGS SENSORS. Technical Information on Usage of TGS Sensors for Toxic and Explosive Gas Leak Detectors

User Manual. PolyGard AT-1130 V3. Electrochemical Nitrogen Dioxide Transmitter. July, 2011

MEMS VOC Gas Sensor. (Model No.:GM-503A) Manual. Version: 1.0. Valid from: Zhengzhou Winsen Electronics Technology Co.

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

CCS240 and CCS241. Technical Information. Sensors for chlorine dioxide Amperometric, membrane-covered sensors for installation in the CCA250 assembly

User Manual. µ-gard MD Electrochemical Carbon Monoxide Transmitter Serial No. MD April, 2011

Manual. MEMS Combustible Gas Sensor. Zhengzhou Winsen Electronics Technology Co., Ltd. (Model No.:GM-402B) Version: 1.0. Valid from:

c) Loss of product or replacement when units are being serviced All of these are factors that need to be considered by the user.

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

This test shall be carried out on all vehicles equipped with open type traction batteries.

The New PHD 4 Portable Helium Detector

AMS 6916 Board mount pressure sensor with ratiometric analog output

LK-SX CO 2 +VOC. Application. Security Advice Caution. Notes on Disposal

PERME- OX2/230 Oxygen Transmission Rate test system

STEAM STERILIZABLE POLAROGRAPHIC OXYGEN ELECTRODE

User Manual. PolyGard DT V4. Electrochemical Carbon Monoxide Transmitter Serial No. DT December, 2008

Oxygen Flue Gas Analyzer BA 2000

MIL-STD-883G METHOD

A Journal of Practical and Useful Vacuum Technology. By Phil Danielson

Miniature Pressure Sensors

LFE OEM TCD - Thermal Conductivity Detector

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

GasSense NDIR User Manual

MEASURING WATER CONTENT IN COMPRESSED BREATHING AIR IN COMPLIANCE WITH EN 12021:2014 ULTRA-PRECISE AND ULTRA-RELIABLE WITH POLYMER TECHNOLOGY

LK-SX VOC. Application. Security Advice Caution. Notes on Disposal. Combined sensor mixed gas. Data sheet

CC Operation Manual Oak Valley Drive, Suite 20, Ann Arbor, Michigan USA fax

PreSens. Manual OxoPlate. OxoPlate OP96C. PreSens Precision Sensing

ASDX Series Silicon Pressure Sensors

Pressure Measurement. Introduction. Engr325 Instrumentation. Dr Curtis Nelson 3/12/18

IRceL Operating Instructions

Air Check Lite Toxic Gas Monitor

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD)

Model Description

OXY 3690 MP. Measuring transducer for air oxygen

2.07 Amperometric Sensors

MANUAL KPS Pressure Control Valve

Overview. Front Panel: Keypad and Display

M iniature Amplified Pressure Sensors

Pressure Sensor Bridge Configurations

Automatic Permeability Testing: The Challenges and Solutions Author: Alyce Hartvigsen, PBI-Dansensor A/S, Ringsted, Denmark

AUK Environmental Sensor. Determining the refractive index of the air. AUK Environmental Sensor

Introduction The Smart Q Oxygen Adaptor enables an Oxygen electrode to be connected to an EasySense unit.

Analysis of RPC Performance with Different Gas Mixture

ZIRCONIA OXYGEN DETECTOR SERVICE MANUAL

Oxygen measurement in diving technology

Transmitter CS 21 Operation Manual

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

Oxymax W COS41. Technical Information. Potentiostatic amperometric two-electrode sensor Long-term stable sensor for water and wastewater applications

AMS 2710 PCB pressure sensor module with V output

MEC OEM. User Manual. Commercial in Confidence

Oxygen & Binary Gas Measurement and Analysis

HIGH ACCURACY MULTI-GAS MONITORING USING AUTOMATED SELF- CALIBRATION

Oxygen Measurement in Natural Gas

WHITEPAPER. The flowplus 16 Pressure Sensor. Physical Principles and Function

AMS 6915 Board mount pressure sensor with digital output (I²C)

210 Series Transmitter with External Electrochemical Sensor

COM280. Technical Information. Oxygen measurement Battery-driven pocket meter for dissolved oxygen measurement

JOLLY2. Installation user s manual. 6 different operating modes selectable. version 3.3. DATA TO BE FILLED OUT BY THE INSTALLER (Page 1)

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

Transcription:

1.1 Two or Three Electrodes? All Sixth Sense cells for toxic gas detection are based on electrochemical principles and can be classified as amperometric fuel cells. The simplest form of electrochemical cell is a two-electrode design and consists of a semi-permeable diffusion membrane, a reservoir of acid electrolyte, a sensing electrode and a counter electrode (see figure 1). The electrodes are generally a PTFE substrate coated with a catalytic mixture, usually platinum, which significantly accelerates the gas reaction. In most cases, gas diffusing into the cell reacts at the surface of the sensing electrode producing, as a by-product, a number of ions (H+) and electrons (e-). The ions travel through the acid electrolyte to the counter electrode whilst the negatively charged electrons travel to the counter electrode via the external circuit. Combining the electrons and ions at the counter electrode completes the reaction without any of the cells components being consumed. The amount of electrons produced by the reaction is directly proportional to the amount of gas present and measuring the current flowing through the external circuit is a basic gas monitor. Figure 1 Two - Electrode Sensor Filter Working electrode Wick (contains electrolyte) V Counter electrode Working: 2CO + 2H 2 0 2CO 2 + 4H + + 4e - Counter: 4H + + 4e - + 2O 2 2H 2 0 This approach harnesses the benefits of electrochemical principles - a linear, stable, repeatable output over long periods, at a reasonable cost. This has proven extremely popular in the domestic/residential carbon monoxide alarm and the commercial fire detection markets. Through automation of the manufacturing process, Sixth Sense manufacture in excess of 1 million units per year and our sensors can be supplied in volume and at a competitive price. With only two electrodes, the drive circuitry is simple and low cost, lending itself to high volume manufacture for the consumer market.

However, the two-electrode approach may not meet the requirements of all gas monitoring markets. For an electrochemical sensor to work at optimum efficiency, the potential of the electrodes needs to change in order to optimise the catalytically assisted oxidation and reduction reactions. This can be demonstrated by connecting a two-electrode device across a load resistor and applying gas. The measured potential of the sensing and counter electrodes will change in opposite directions. However, in operation it is necessary to use an operational amplifier in the circuit. In use, this will attempt to keep both electrode potentials the same and therefore the sensor cannot operate at maximum efficiency. In very high levels of gas, the potential of both electrodes will become slightly negative. This optimises the reaction at the counter electrode but limits the activity of the sensing electrode, which ultimately results in a non-linear signal. The point at which the sensor becomes non-linear is defined on the data sheets as the "maximum overload". All electronic components have an operating tolerance and therefore do not work perfectly all of the time. As such, whilst an OpAmp is designed to maintain a zero potential difference between its inputs, in extreme situations there can be a minor difference. Since the two electrode potentials of a sensor try to move in opposite directions during operation, it is possible for the sensor to polarise very slightly (+/- 3-4mV). This can occur after long periods in high gas concentrations and when the gas is removed the sensor will be slightly unstable until such time as the sensor has de-polarised. Depending on the degree of polarisation, this recovery period can be a number of hours. The combined result is that the two-electrode sensors are normally restricted to use where low levels of gas are being monitored and/or where the finished product is alarm only and operates in a "latched mode". For other applications, mainly in the industrial sector, a three-electrode sensor is recommended. In this case a third (reference) electrode is added. This is held in an environment in which it will not see gas and therefore plays no part in the reduction/oxidation reactions in the sensor. As such the reference electrode will maintain constant potential. In operation, the measurement is taken between the sensing and the reference electrodes, allowing the potential of the counter electrode to change as necessary without affecting that of the working electrode. Therefore, the performance of a three-electrode sensor is more efficient and generally they will have a higher output than that of a two-electrode device and can be used to monitor a wider range of gas concentrations.

1.2 Operating Circuits for Two-Electrode Sensors For most applications using two-electrode sensors, neither the absolute resolution nor the response time is overly critical. It is therefore possible to use lower cost components in the drive circuitry. The basic circuit is a current to voltage converter with a permanent load resistor across the two sensor electrodes to prevent polarisation during an un-powered period. An example of this is shown in figure 2. For gases that are oxidised at the working electrode the output from the circuit will be positive and for gases that are reduced, the output will be negative. Figure 2 Two - Electrode Circuit C2 R3 Recommended values: R1 = 10k Working R2 Vcc - + IC1 TH R2 = 120k R3 = 100k TH = Thermometrics DKF503 C1 = 100nF C2 = 22uF IC1 = TLC27L2 Cell R1 C1 Vout Counter 0V This circuit uses a low-cost OpAmp with an input offset voltage of 10mV and therefore a high value for R1 is required to ensure an acceptable zero offset from the OpAmp output. Whilst this does not affect the response time of the circuit, it will exhibit a longer stabilisation period. For applications where this is not acceptable or where a higher resolution is required, such as fire detection, a number of changes can be made to improve the overall performance. Firstly it is possible to use a different OpAmp with a lower input offset voltage such as an OP90 with a typical offset voltage of 150uV. The value of R1 can then be lowered significantly and the final value can be set depending on the precise requirements for the maximum zero offset that can be accommodated. In practise R1 could be removed altogether and replaced with a J-FET (eg. J177). This allows optimum performance but ensures that the electrodes are shorted when the circuit is un-powered. To further improve the stabilisation of the circuit, it is possible to include a 10-20 Ohm resistor between R1 and the negative input of the OpAmp. This slightly increases the response time, but the affect is negligible and the circuit output will be more stable.

1.3 Operating Circuits for Three-Electrode Sensors Most applications using three-electrode sensors require higher resolution, faster response time and rapid stabilisation. For these reasons we recommend a dual-opamp circuit that combines performance and flexibility. A suitable circuit is shown in figure 3. For a specific type of sensor, the circuit can be optimised for use with a full range of gas types. One example of this is the MICRO range and an optimised variation of the standard circuit is shown in figure 4. Figure 3 Standard Three - Electrode Circuit +ve + IC1 - C2 C W R C1 -ve RB RF RL +ve - IC2 + V out -ve OV V OUT = Gas Conc x Cell Output x R F - If R F is 100k, cell output is 50nA/ppm and gas concentration is 100ppm then V OUT = 100 x (50x10-9 ) x (100x10 3 ) = 0.5V Output is positive for oxidising sensors (CO & H 2S) and negative for reducing sensors (CL 2 ). If it is necessary for all outputs to be positive, please contact Sixth Sense for advice R L is the cell load resistor (typically 5-50Ω). A small value of R L will increase noise, but give a faster speed of response; and vice versa. Sensor data sheets provide recommended values for each sensor Amplifiers are precision low input offset types, eg. OP90 or similar C 1 and C 2 help to reduce sensor signal noise and EMC susceptibility. Typical values are C 1 4.7nF and C 2 47pF

R B stops the sensor polarising when the circuit is powered off (typically 1-10k). This can be replaced with a J-FET (eg. J177). Some sensors require temperature compensation circuitry (eg. CO). A simple compensation network can be incorporated into this circuit by replacing R F. Some sensors, eg. CO 2, require a small bias voltage across their electrodes. For information on this type of circuit, please contact Sixth Sense Figure 4 Micro Circuit Vcc 470Ω 100 F 0V Direction of current flow in gas V LK1 10K NTC Output - CO, HS W R C CL C R W 100Ω LK2 LK1 J177 - + 33K 100K Output + LT1077 or any good low input offset op-amp, eg. OP9O 100Ω LK2 2K 0V LK1 used for positive output sensors (CO & H 2S) LK2 used for negative output sensors (CL 2)

1.4 Environmental Conditions Most electrochemical sensors exhibit a small change in output due to changes in environmental conditions. In most applications, these are unnoticeable and can be ignored, but where greater measurement resolution is required, simple compensation can be incorporated into the drive circuit. Typical effects are: Pressure - most Sixth Sense products are partial-pressure sensors and therefore the diffusion rate of the target gas will change in line with ambient pressure. Therefore there can be a perceived change in sensor output. This is typically less than +1% signal per 100mBar change Temperature - all electrochemical sensors rely on catalytic reactions and as such the output of the sensors are affected by changes in temperature, accelerating or impeding the reaction. Fortunately this effect is extremely repeatable and can be compensated easily using either a standard thermistor in the drive circuit or by using look-up tables pre-programmed into a suitable E 2 PROM. All product data sheets contain details about the degree of temperature compensation required and further details can be obtained from Sixth Sense. Some sensors, eg. CO, also display a small change in the baseline signal and details are given on the relevant data sheets. Humidity - most electrochemical sensors contain a small amount of acid based electrolyte which, by its nature, is hygroscopic. Therefore, water vapour will be either absorbed or released from/to the surrounding atmosphere depending on the relative humidity. Sixth Sense products have been optimised to work unaffected for long periods in the range 15-90% RH. Long periods in excess of 90% R.H or below 15% R.H. can affect the performance of electrochemical sensors. If this is a possibility, please contact Sixth Sense for further information. At all times it is imperative that non-condensing conditions are maintained to prevent water droplets forming on the sensor itself. Oxygen - most electrochemical sensors require small amounts of oxygen at the counter electrode in order to complete the catalytic reaction. They should not, therefore, be used in applications where no oxygen will be present in the surrounding atmosphere. For short periods, ie. less than 10 minutes, they can operate without oxygen since there will be sufficient absorbed in the electrolyte. This allows calibration with dry gases.

1.5 Effect of Interfering Gases Due to the highly active nature of the catalysts that are used in electrochemical sensors, they can oxidise or reduce gases other than the target gas. In these cases, the sensor exhibits a cross-sensitivity which can, on occasion, be used to extend the measurement capability of the sensor. For example, chlorine sensors exhibit a significant cross-sensitivity to chlorine dioxide (ClO 2 ), Bromine (Br 2 ) and Ozone (O 3 ) and can therefore be used as a suitable sensor for detecting these gases when none of the others are present. Where at all possible and appropriate, the effect of interfering gases is reduced by careful catalyst selection, the use of on-board filters or by applying a bias voltage between the working and reference electrodes. Details of all cross-sensitivities are included on individual data sheets. 1.6 Stabilisation All three-electrode sensors from Sixth Sense are delivered fitted with a shorting link across the electrodes. This ensures that they arrive ready to use and do not require further stabilisation when they are fitted into a product. This link must not be removed until just prior to use and the drive circuitry must ensure that the working and reference electrodes are shorted during un-powered periods. Failure to do this will mean that the sensor may require a period of some hours to stabilise. Since most customers purchase the two-electrode sensors in very large volumes, they are not normally fitted with shorting links. Instead, they should be shorted and left to stabilise at least two hours prior to use. Please contact Sixth Sense should you wish sensors to be delivered with shorting links pre-fitted. Some sensors require a small bias voltage, eg. CO 2, and to ensure that they are ready to use on delivery, they are fitted with a small PCB that maintains the correct bias voltage across the electrodes. This should be removed prior to use and returned to Sixth Sense for credit against further purchases. 1.7 Physical Protection Whilst the sensors are manufactured to withstand normal environmental conditions, they should be protected from dirt, dust and water ingress. This can be achieved cost-effectively by installing a semi-permeable membrane barrier between the sensor and the external atmosphere (eg, PTFE or Gore-Tex ). If this is not used, it is possible that the sensor may become blocked, preventing gas from diffusing in.

1.8 Intrinsic Safety Information is given on individual data sheets, stating the maximum current during normal operation, the maximum open circuit voltage and the maximum short circuit current, all of which must be considered when designing products that must be intrinsically safe. Theoretically it is possible for an electrochemical sensor to produce up to 1.25V during an open circuit, but since most of the reactions are irreversible the full potential is never reached. In summary all electrochemical sensors from Sixth Sense meet the following: At no time, regardless of the fault status, will the Sixth Sense range of sensors produce a voltage greater than 1.3V and a current greater than 1.0A 1.9 Calibration All gas detection products should be tested and calibrated using the target gas prior to use. Once in use, Sixth Sense products are designed for extended use without re-calibration but they should be verified, and calibrated, if necessary, at least every six months. Some applications are regulated by legislation that dictates the minimum calibration intervals and these should be observed at all times. Where calibration is not possible, a suitable cell supervision circuit should be used, details of which are given in Application Note 3. Since most electrochemical sensors are linear, then only a single-point calibration is required. The concentration of gas used should represent the actual concentrations to be experienced in the field, typically the upper alarm limit of the gas detector. Where it is not possible to prescribe this, a concentration towards the upper limit of the sensor range should be used. To avoid pressurising the sensor and so affecting it s performance, flow rates in excess of 1litre/minute should be avoided. It is, however, important to ensure that the sensor is exposed to sufficient gas to obtain a stable reading. Table 1 gives examples of suitable calibration concentrations and minimum flow rates required for effective calibration. The data shown is based on a minimum exposure time of five minutes. For gases not shown, please contact Sixth Sense for assistance. Table 1 Gas Concentration (ppm) Minimum Flow Rate (ml/min) Carbon Monoxide 200 150 Hydrogen Sulphide 20 250 Chlorine 10 1000

1.10 Testing All toxic gas sensors from Sixth Sense are individually tested with their target gas prior to delivery. Using a unique computerised testing system, over a dozen parameters are recorded during the test cycle and recorded against the corresponding serial and batch numbers. For further details about the test procedure or to arrange for test results to be sent with your sensors, please contact Sixth Sense. 1.11 Identification & Packaging All toxic gas sensors from Sixth Sense are individually labelled and identified by part number, gas type, serial number and the batch/date code. If required, further information can be added upon request, such as sensor output or your company name. For specific labelling requirements, please contact Sixth Sense for advice. Our gas sensors are packaged in hermetically sealed containers to protect them from the stresses of transportation and environmental conditions. We recommend that they are stored in their original packaging to maximise their operating life. For shipments over 100 units, sensors are packed in trays of 100 and up to 10 trays will be sealed in a metallised plastic outer bag which is subsequently sealed in a ruggedised cardboard box for shipment. Both the outer bag and box will be marked as detailed above. For more specific details on packaging or to arrange an alternative method, please contact Sixth Sense.