Instructions for using TSI Model mm or 8025-CEN Fit Test Adapter Kit

Similar documents
Respirator Fit Testing DEPARTMENT OF LABOR Information on the Requirements Types of Respirators & Filters

Vortex Tube Respirator

Standards of Practice Respiratory Protection: Appendix C

Respiratory Protection. Program

PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION

Half Facepiece Respirator Assembly 5000 Series, Dual Cartridge, Organic Vapor/P95, Disposable

Section1. Knowledge of RPE Sets out the minimum knowledge requirements in respect of respiratory protective equipment. [Mandatory] 1.

UltraFilter. respirator. with Ultravue or Ultra Elite Facepiece. instructions for use and care

Respirator Fit Testing and Respirator Fit Testers. Operation and Service Manual

Checklist for care of Respirators

Respiratory Protection Training

Half Facepiece Respirator Assembly 5000 Series, Dual Cartridge, Disposable

Encore PE 50-lb Feed Hopper

PENETRATION OF N95 FILTERING- FACEPIECE RESPIRATORS BY CHARGED AND CHARGE- NEUTRALIZED NANOPARTICLES

OHD Quantifit Training

MASK INTEGRITY TEST ACCESSORY (MITA) MODEL 8120

10 DRIP NOZZLE WATERING DRIP KIT Model / Model 46095

Respiratory Protection

Fit Testing. C50 APR New Equipment Training Module March 2010 Rev01

NHR-X-X Encore Feed Hoppers

Fiber Optic Lighted Bubbler Spillway Pot (DLP-45) Installation Manual

Chapter 9 Accessories for the Kirby Morgan BandMasks

Air-Mate High Efficiency Powered Air Purifying Respirator (PAPR) Staff Training Module

Gas Lines. Technical Manual. Sumitomo (SHI) Cryogenics of America, Inc Vultee Street Allentown, PA U.S.A.

Respiratory Protection in Agriculture

University of Dayton Respiratory Protection Program 29 CFR

Respiratory Protective Equipment Program Appendix A - Definitions and Key Terms

Respiratory Protection for Producers

E3628 THE RESPIRATORY PROTECTION PROGRAM: EMPLOYEE TRAINING. Leader s Guide ERI Safety Videos EMPLOYEE TRAINING

FACILITIES MANAGEMENT OFFICE OF ENVIRONMENTAL HEALTH AND SAFETY Respiratory Protection Policy 03/20/15 Last Revision

Technical Bulletin. Parts and Service News. LPG Lock-Off valve replacement procedures for 4.2 Liter Ford V6

RESFT 101 Intro to Quantitative Fit Testing

Procedure 85 Attaching The Humidifier To The Oxygen Flow Meter Or Regulator. Procedure 86 Administering Oxygen Through A Nasal Cannula

Respiratory Protection Program 29CFR

3M Occupational Health and Environmental Safety Division. Options

HOW TO USE A RESPIRATOR

University of Alabama Office of Environmental Health and Safety. Respirator Protection Training

Installation, Operation and Maintenance Manual for Back Pressure Regulator

DREW UNIVERSITY RESPIRATORY PROTECTION PROGRAM DRAFT 06/11

A. Evaluation of the written program

CO2 Tank Conversion Kit P.N , P.N , and P.N

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

BioPak 240 Revolution

4400 TwinHybrid Gas Seal

Respiratory Protective Equipment

Booster Pump PB4-60 Replacement Kits

"RESPIRATORY PROTECTION AND SAFETY"

Chapter 9 Accessories

BREATHE SAFELY: The Proper Use of Respiratory Protection

Phalanx Alpha Phalanx Beta and Ultra Elite

M7XT Parts List PARTS LIST. TAL 1504 (L) Rev. 2 MSA 2015 Prnt. Spec (I) Mat Doc

How to Make a Respirator Program and Calculating the Cost

Selecting Respirators and Associated Equipment Monthly webinars from AFS- PROPOSED SCHEDULE

Product Information News

One Mask. Countless Possibilities. [ Introducing the new Advantage 4000 Facepiece ]

SERVICE MANUAL MODEL BA100BMST 100 SCFM PORTABLE AIR PANEL

RESPIRATORY 6 PROTECTION

The Following information is based on material prepared by the American Lung Association

Installation Procedure for your Disco Double Kit, by Airgun Lab, LLC.

SR500 PAPR Copyright 2015 by The S.E.A. Group 1

Respiratory Protection

URN (UNIVERSAL RODENT NOSE CONE) (17mm diameter) Figure 1

3M Half and Full Facepiece Respirators. Unsurpassed comfort. Maximum versatility. 3Innovation

RESPIRATORS & FIT TESTING

PANACEA P200 STAINLESS STEEL USER MANUAL

Sanitizer Parts. Sanitizer Parts. Replacement Parts for Sanitizers

Filter cartridge protection class A2 Organic vapours, with boiling point above 65 C, to 50X OEL or 1000 ppm, whichever is the lower.

Intro: by firechim on October 3, 2013

Head Cover BE-12 Series

INSTALLATION INSTRUCTIONS 1/2 THERMOSTATIC VALVE AND TRIM

Combination Breathing Apparatus

Installation and Operating Manual

TWO POST RAM PACKAGE 5 GALLON READ THIS MANUAL CAREFULLY BEFORE INSTALLING, OPERATING OR SERVICING THIS EQUIPMENT.

Operation and Maintenance Manual for GENTEC Model 881VR Continuous/Intermittent Digital Suction Regulators

photo coming soon Product Family Respiratory Replacement Parts Corporate - English Page 1 of 23 Product Numbers & Ordering Information

1. CONDITIONS FOR USE 2. SAFETY

photo coming soon Product Family Respiratory Replacement Parts Canada (English) Page 1 of 17 Product Numbers & Ordering Information

Don t Forget About Fit What You Need to Know About Respirator Fit-testing

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER FILTER DRYER

Techcon Systems TS1258 Pressure Pot

SOTR Special Operations Tactical Respirator

MMR Air Mask With. with Quick-Connect Hose

PremAire INSTRUCTIONS FOR DUAL-SUPPLY MODE OF OPERATION

INTENDED USE TECHNICAL SPECIFICATIONS

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

PAPR Flow Tester. instructions. part no WARNING

Cabinet. 1.0 POLICY It is the policy of Calvin College to comply with the MIOSHA Respiratory Protection Standard Part 451.

Tribomatic II Powder Pump

Cryogen Dispenser. Directions for Use.

Respiratory Protection Program

HOSPITAL: Date: Date: Date: Date:

PANACEA P125 USER MANUAL

Respiratory Protection

RESPIRATOR PERFORMANCE TERMINOLOGY

Agilent 1290 Infinity Pump Head Maintenance

Basic layout 2016 IRRIGATION-MART. Check (Non- Leak) Valve. Friction Fit. Sprinkler. Figure 1 - Hanging Sprinkler & Check Valve Assembly

European Technical Standard Order (ETSO)

PPE Refresher Using your SCBA

Operation Manual. Carbon Filtration Industrial Drive, Orlinda, TN fax

Respiratory Protection

Transcription:

Instructions for using TSI Model 8025-40mm or 8025-CEN Fit Test Adapter Kit Kit Contents: Qty. Description 1 Adapter Assembly 50-ft 3/16-in OD 1/8-in ID PVC Tubing* 200 Suction Cups* 200 Clips* 1 Scissor 1 Measuring Scale 1 High Efficiency Filter with 40-mm Thread 1 Storage Case 1 Instructions (this document) *Reorder TSI Refill Kit part no. 800553 for additional Clips (200), Suction Cups (200) and Tubing (50-ft). PORTACOUNT Plus Model 8020 The TSI Model 8025-CEN and 8025-40mm Fit Test Adapter is a device that allows a PORTACOUNT Plus Respirator Fit Tester to quantitatively fit test virtually any tight-fitting respirator facepiece that has a standard 40- millimeter threaded inlet. 1. Expose the 40-mm threaded inlet on the facepiece. For negative-pressure masks, simply remove the filter canister. For positivepressure masks such as SCBA and PAPR, remove the air supply hose and/or maskmounted regulator to expose the 40-mm threaded inlet. If there is no 40-mm threaded inlet, this adapter will not work for that mask. Note: Positive-pressure masks must be fit tested in negative-pressure mode as if they were a negative-pressure mask. This is in accordance with all fit testing regulations throughout the world including OSHA, ANSI, CSA, HSE, etc. Copyright 2013 Page 1 of 6 e-mail: answers@tsi.com

2. Attach a length of flexible tubing to the fitting on the front of the adapter. The appropriate length is different for each type of mask. Use enough tubing to reach the breathing zone without stretching or pinching the tubing. For a full face masks, try using about 10 inches of tubing the first time. Excess tubing will be trimmed off the end inside the mask in a later step. Measure and cut the correct length of tubing for subsequent fit tests. 3. Thread the flexible tubing through the inhalation valve and into the breathing zone inside of the mask. Do not remove the mask s inhalation valve. The valve is necessary because it is also a gasket. Threading the tube through some full-face masks may be difficult because the air flow path is complex. It will become much easier with practice. Failure to use a tube running into the inside the mask will result in fit factors that are artificially high. Copyright 2013 Page 2 of 6 e-mail: answers@tsi.com

4. Screw the adapter onto the mask by spinning the outer ring. Do not allow the adapter body to rotate and twist the flexible tubing. If the mask is equipped with a nose cup, thread the tube through a nose cup inhalation valve and into the inside of the nose cup. It is very important for the end of the tube to be located to allow air to be sampled from the breathing zone of the mask near the nose and mouth. 5. Trim any excess from the end of the tubing that is inside the mask (or nose cup) so that there is no unnecessary slack. Copyright 2013 Page 3 of 6 e-mail: answers@tsi.com

6. Attach a clip and a suction cup to the end of the tube that is inside the mask (or nose cup). The neck of the clip is hollow so that air may pass through it. The purpose of the clip and suction cup is to anchor the end of the tube so that it cannot be inadvertently blocked due to contact with the skin, lips, or nose. The suction cup, clip and tube will be contaminated by the breath of the person being fit tested. These parts should be discarded and replaced with new (clean) parts for each person. The kit includes 200 clips, 200 suction cups and sufficient tubing for about 200 fit tests. Reorder TSI Refill Kit part no. 800553 for additional Clips (200), Suction Cups (200) and Tubing (50-ft). 7. Attach the suction cup to a smooth surface inside the mask near the nose and mouth. Make sure the tubing inlet cannot be accidentally blocked. The suction cup may stick better if the mating surfaces are wetted or wiped with an alcohol swab first. Copyright 2013 Page 4 of 6 e-mail: answers@tsi.com

8. Screw a filter canister onto the back of the fit test adapter. Make certain that the filter is a high-efficiency type filter (HEPA, P100, P3, etc.) with a 40-mm thread. This kit includes a 40-mm P100 filter. Any brand of high-efficiency HEPA, P100 or P3 filter canister can be used as long as it has a standard 40-mm thread. Combination cartridges are not recommended because they sometimes shed carbon particles that will be interpreted as face seal leakage by the PORTACOUNT fit tester. 9. Attach the clear PORTACOUNT mask sample tube to the fitting on the side of the fit test adapter. You are now ready to proceed with the fit test. Copyright 2013 Page 5 of 6 e-mail: answers@tsi.com

PRECAUTIONS Make certain that a tube is used inside the mask. This ensures that air is sampled from the breathing zone near the nose and mouth. If there is no tube used to draw air from the breathing zone, only clean filtered air will be sampled and all fit tests will result in extremely high (over 100,000) fit factor values. These fit factors will not be correct. Make certain that the flexible tube inside the mask is not blocked, twisted or pinched. A blocked tube will result in high fit factors that are not correct. Make certain that the filter canister is a high efficiency type filter (HEPA, P100, P3, etc.). Using the wrong type of filter will result in very low fit factors because ambient air particles can pass through it. Combination HEPA/Gas filters are not recommended because they sometimes shed carbon particles. This will result in low fit factors because the shed particles will be interpreted as face seal leakage by the PORTACOUNT fit tester. The flexible tubing used inside the mask should be 1/8 inch (3 mm) inside diameter 3/16 inch (4.5 mm) outside diameter PVC tubing. Do not use Teflon or silicone tubing because particles do not pass through them properly due to static charge issues. To test the fit test adapter, create a large leak by placing an object like a pencil in between the test subject s face and the mask. The resulting fit factor should be very low. Copyright 2013 Page 6 of 6 e-mail: answers@tsi.com