One of the guarantees of quality: External Quality Control. Finlay MacKenzie

Similar documents
TG GUIDELINES CONCERNING CALIBRATION INTERVALS AND RECALIBRATION

Maximum precision for quantifiable success.

General Accreditation Guidance. User checks and maintenance of laboratory balances

Service Calibration are you doing it properly?

Gas mixtures. Individual solutions specifically for your application

Certification of AMS acc. EN 15267, Part 3 - Overview and First Experience -

Keeping It Simple. Gas Mixtures for Stack Emissions Monitoring.

Skills Key Words. Task. Key words. Write a definition for each of the key words listed below. Hypothesis. Variable. Prediction. Method.

Quality Assurance Charting for QC Data

WP Eliminating Oxygen from the Purge Gas and the use of Monitoring Equipment

Review of ISO10723 Performance Test Frequency. By Anwar Sutan

Now it is. easy to switch. CHS TM Steroid Profiling kit and software. Brochure not for distribution in the USA and Canada

Stability and traceability of calibration gases for EN 14181

Installation Procedure Esco Miri Multi-Room Incubator

PROTOCOL FOR COMPRESSED AIR PROFICIENCY TESTING (CAPT) PROGRAM SAMPLE ANALYSIS

So you want to be a RCM

Fishery Improvement Projects

Quality Control and Quality Assurance at the Mill. Philip Randall Tanzania 5 th April 2011

Specific Accreditation Criteria Calibration ISO IEC Annex. Mass and related quantities

SFHGEN77 - SQA Code HD48 04 Perform first line calibration on clinical equipment to ensure it is fit for use

PERFORMANCE TEST INSTRUCTIONS FOR BIOHIT PROLINE PIPETTORS

Understanding safety life cycles

A SIMPLE TITRATION METHOD FOR DETERMINING THE SPECIFIC GRAVITY ON ONE DROP OF URINE

Visual Inspection of Medicinal Products for Parenteral Use

EN ISO/IEC Technical Requirements

Proficiency Testing Corrective Action Checklist: PT PROVIDER: PT EVENT: TEST:

Controls and Control Charting

Competitive Performance of Elite Olympic-Distance Triathletes: Reliability and Smallest Worthwhile Enhancement

CASE STUDY ON RISK ASSESSMENTS FOR CROSS CONTAMINATION. Stephanie Wilkins, PE EMA Workshop June 2017

Calibration Requirements for Direct Reading Confined Space Gas Detectors

Service ISO17025 explained

Improve Process Reliability

UKAS calibration laboratory 8809 Temperature, pressure and electrical signals calibration guide

Supersedes: The copy of this document located on Measurement Canada s website is considered to be the controlled copy.

Quality Control of Pulmonary Diagnostic Systems

Appendix. Part 1: References Part 2: Automatic Analysers 114

Helicopter Safety Recommendation Summary for Small Operators

Light Lab. Reliable Measurements through Regular Calibration. DAkkS

Tissue-Tek Prisma Plus & Tissue-Tek Glas TM g2

Some information on Statistical Process Control (SPC) c charts that may be useful for clinical teams

INFORMATION NOTE No 353: MICROBIOLOGICAL TESTING

DRAFT FOR DISCUSSION Water Forum Terms of reference: September 2016

METHOD 3A - DETERMINATION OF OXYGEN AND CARBON DIOXIDE CONCENTRATIONS IN EMISSIONS FROM STATIONARY SOURCES (INSTRUMENTAL ANALYZER PROCEDURE)

Technical Report. 5th Round Robin Test for Multi-Capillary Ventilation Calibration Standards (2016/2017)

Field verification of on-line HC dew point measurements

extraction of EG and DEG from the matrix. However, the addition of all diluent at once resulted in poor recoveries.

FISH 415 LIMNOLOGY UI Moscow

imágenes en el Hospital Clinic

Risk Management Series Article 8: Risk Control

Fishery Improvement Projects

Road safety training for professional drivers: worldwide practices

Conservation Limits and Management Targets

Section 1: Multiple Choice

VIROLOGY QUALITY ASSURANCE PROGRAM STATISTICAL CENTER

Gas flow calibrations performed at the National Metrology Institute of South Africa (NMISA)

Ti-Pure TITANIUM DIOXIDE DETERMINATION OF SLURRY RHEOLOGY METHOD: T WP

SPE MS Well Collision Avoidance Management and Principles

Air Pressure Test to EN13829:2000

Chapter Pipette service & maintenance. Pipette specifications according to ISO Repair in the lab or return for service?

OXFORD CALIBRATION WEIGHTS CLASS E1, E2, F1

Improved Reliability in Natural Gas Energy Measurement with the Revised ISO Standard. Gerard Nieuwenkamp - VSL

Workshop Information IAEA Workshop

Balancing and Settlement Code. Code of Practice Four

TECHNICAL BULLETIN. TriControls. Control Materials for Liquid QC and Calibration Verification

CADF Business Report 2012

SOP 407: PROTOCOL DEVIATIONS AND UNANTICIPATED PROBLEMS

Level 2 Award in Working in High Risk Confined Spaces

Gas Network Craftsperson

OIL & GAS. MTS DP Committee. Workshop in Singapore Session 4 Day 2. Unwanted Thrust

The Infrastructure Impact Tool

CALIBRATION SYSTEM REQUIREMENTS. ESCC Basic Specification No

PUBLISHED PROJECT REPORT PPR850. Optimisation of water flow depth for SCRIM. S Brittain, P Sanders and H Viner

The Gold Standard in Calibration Mixtures

IV. Basic Procedures for Human Research Protections

GIBRALTAR MARITIME ADMINISTRATION (Ministry of Maritime Affairs)

UniBloc technology and over 80 years of experience in precision weighing. Registered

Safety assessments for Aerodromes (Chapter 3 of the PANS-Aerodromes, 1 st ed)

NAME: A graph contains five major parts: a. Title b. The independent variable c. The dependent variable d. The scales for each variable e.

How and why Eurotrol s CueSee Hypoxic works

SITE NAME: ISF DOCUMENT VERSION CHECKLIST Complete yes or no to confirm the presence or absence of each document specified.

Parallel Session 1A Sterile Manufacture. Denise Coakley. GMP Conference 12 th November 2014

DETERMINATION OF SAFETY REQUIREMENTS FOR SAFETY- RELATED PROTECTION AND CONTROL SYSTEMS - IEC 61508

Homeostasis and Negative Feedback Concepts and Breathing Experiments 1

Level 3 Award in Emergency Rescue and Recovery Of Casualties from Confined Spaces

Gerald D. Anderson. Education Technical Specialist

LIFT MAINTENANCE POLICY

Investigating the effects of interchanging components used to perform ripple assessments on calibrated vector network analysers

Baptist Health Institutional Review Board. Study Closure Report (Expedited Review) IRB #: Study Title:

BOC Healthcare training

CONTINUING REVIEW 3/7/2016

PRINCIPLES FOR THE SELECTION AND MANAGEMENT OF EUROPEAN ATHLETICS ONE-DAY OUTDOOR MEETINGS

I N N O V A T I O N C O N T I N U E S... International Patent Filed in 45 Leading Countries

2017 RELIABILITY STUDY STYLE INSIGHTS

Gas Mixture Two Components. Gas Mixtures Two Components

STD-3-V1M4_1.7.1_AND_ /15/2015 page 1 of 6. TNI Standard. EL-V1M4 Sections and September 2015

Beamex. Calibration White Paper. Weighing scale calibration - How to calibrate weighing instruments

Best Practice RBI Technology Process by SVT-PP SIMTECH

VIROLOGY QUALITY ASSURANCE PROGRAM STATISTICAL CENTER

GAS TRANSPORTER S REQUIREMENTS FOR GAS MEASUREMENT SYSTEMS CONNECTED TO THE NATIONAL GRID GAS NETWORK

Continuous Gas Analysis In situ laser gas analyzers TÜV and MCERTS add-on for LDS 6 operating instructions Compact Operating Instructions

Transcription:

One of the guarantees of quality: External Quality Control Finlay MacKenzie

One of the guarantees of quality: External Quality Control Mexico EMA 2017 Finlay MacKenzie Director, Birmingham Quality UK NEQAS Birmingham 2

The Narrative of EQA I am going to talk about: Definitions and nomenclature What is the EQA process? Regulatory systems and structure of the NHS in the UK What does EQA look like in practice? Performance surveillance of Laboratories and postmarket surveillance of kits/methods/products Numbers, numbers and interpretation Reference methods and commutability Scoring systems and Scheme design a rejection of the blind adherence to too many statistics on too few data points

The Narrative of EQA I am going to talk about: Definitions and nomenclature What is the EQA process? Regulatory systems and structure of the NHS in the UK What does EQA look like in practice? Performance surveillance of Laboratories and postmarket surveillance of kits/methods/products Numbers, numbers and interpretation Reference methods and commutability Scoring systems and Scheme design

Definitions of EQA External Quality Control Some call it External Quality Assurance I prefer External Quality Assessment It is retrospective, and though part of a bigger system, it in itself cannot assure, neither can it control. It can assess, it can influence and it can point the way forward, it can drive improvement but it can t assure that everything will always be right all of the time. Total Quality Assurance is IQC + EQA + Training + Education + Accreditation + Audit etc etc

The Narrative of EQA I am going to talk about: Definitions and nomenclature What is the EQA process? Regulatory systems and structure of the NHS in the UK What does EQA look like in practice? Performance surveillance of Laboratories and postmarket surveillance of kits/methods/products Numbers, numbers and interpretation Reference methods and commutability Scoring systems and Scheme design

The EQA Process External Quality Assessment Scheme PROVIDER 1. Clinical material dispatched to the USER laboratory External Quality Assessment Scheme USER 2. Clinical Material received by the USER laboratory 5. RESULTS from all participating USER laboratories analyzed and a report indicating the performance of an individual laboratory's performance in relation the performance of all participating laboratories 3. Clinical material examined by the USER laboratory and the results recorded 4. Examination results returned to the External Quality Assessment scheme PROVIDER 6. Report indicating the performance of an individual USER laboratory's performance in relation to the performance of all participating laboratories 7. USER laboratory reviews its performance in relation the to the performance of all participating laboratories and takes action to remedy any problems

The Narrative of EQA I am going to talk about: Definitions and nomenclature What is the EQA process? Regulatory systems and structure of the NHS in the UK What does EQA look like in practice? Performance surveillance of Laboratories and postmarket surveillance of kits/methods/products Numbers, numbers and interpretation Reference methods and commutability Scoring systems and Scheme design

The UK is either the best in the world or is struggling for funding (fake news?) It is true that treatment is free at the point of contact 9

The NHS complicated structure across England Now having SSTs of 1 to 2 million people where Labs and hospitals and local government don t always cover same geographical locale! 10

The Regulatory Environment

Pathology Quality Assurance Review Jan 2014

ISO 15189:2012

The Narrative of EQA I am going to talk about: Definitions and nomenclature What is the EQA process? Regulatory systems and structure of the NHS in the UK What does EQA look like in practice? Performance surveillance of Laboratories and postmarket surveillance of kits/methods/products Numbers, numbers and interpretation Reference methods and commutability Scoring systems and Scheme design

ROLE OF EXTERNAL QUALITY ASSESSMENT EQA provides assessment of: the overall performance (state of the art) the influence of analytical procedures (method, reagent, instrument, calibration) individual laboratory performance the specimens distributed EQA PROVIDES AN EDUCATIONAL STIMULUS TO IMPROVEMENT EFFECTIVE EQA To be effective, EQA must be accepted and seen as useful, requiring: Organising centre Participant Prepare specimens Examine specimens Analyse results Report results Prepare report Evaluate performance full, regular participation specimens treated as routine confidence in scheme design remedial action taken

Scheme Design For EQA success, participants must have confidence in the scientific validity as well as the reliability of its operation, or they will not take action on information from the scheme sufficient recent data, achieved through: frequent distributions at least 4 per year monthly ideal multi-specimen distributions rapid feedback of performance information before the next distribution few days ideal faster using our web service! an appropriate basis for assessment stable, homogeneous specimens behave like clinical specimens reliable and valid target values effective communication of performance data a rolling time window scoring system structured, informative and intelligible reports

Purpose of scoring: comparison of performance over: Requirements of scoring: robust Time independent of other participants' performance SCORING Place Individual lab yes yes All participants yes yes a 'z score' (SDD, SDI) based on observed SD is not satisfactory in my opinion despite it being widely used across the world yes yes Participation (return rate) Non-analytical errors ('blunders')? Accuracy (total error) single survey yes No yes yes Accuracy running Imprecision NO! must assess from IQC... Bias running Consistency of bias - running

'THE ABC OF EQA' ~ Basic Scheme Statistics and Nomenclature There are: Specimen level statistics Rolling time window level statistics The role of EQA within the overall QA setting Laboratory-specific Method-specific Overall [all laboratories, all methods] A set of three complementary scores: A is for Accuracy (total error) B is for Bias C is for Consistency of bias Percentage bias: bias = (result - target) / target * 100 % transformed bias: = bias * 'degree of difficulty factor' [normalised] Our scores are unashamedly robust, trend [data] scores. This is their strength If you want to know if your run, batch or day's work is fit to be released then you must operate a good, robust IQC programme as part of your total QA policy EQA data is by its very nature retrospective. It is not intended to allow you to pass or fail each assay run. It does, however, give an incredible amount of valuable information that is impossible to glean from IQC data alone

The basics of EQA EQA gives information on relative bias If the specimens are commutable and reference methods are available, EQA can give information on absolute bias The frequency of testing, the scheme design and concentration levels addressed are crucial in assessing whether the data from EQA is relevant and truly meaningful

The Basics of the ABC Scoring system Each of these 3 scores is calculated over a rolling time window Each 'running score' comprises data (results) from many specimens they are therefore always being updated with fresh current data, and at the same time historical data drops out of the 'time window : 6 7 8 9 1 2 3 4 5 6 7 8 9 The time window we have employed has been set at 6 distributions (equivalent to 6 months) for 'standard schemes (3 specimens monthly) In order to obtain sufficient data from less frequently assessed assays, a period of 12 months may be required [Though the details are dependent on individual schemes, the principle holds true for any UK NEQAS Birmingham scheme]

EQA as audit - a quality improvement cycle Observe current practice EQA reinforces best practice Implement change Set standards Compare practice with standard EQA demonstrates need for education / new guidelines

Educational EQA and Knowledge Gain Custom & practice specificity sensitivity Clinical opinion Clinical Domain Research literature Clinical validity Knowledg e Gain State-of-the-Art (before survey) EQA Domain Good Scheme Design State-of-the- Art (after survey) Politics Instrument constraints Technical Domain Commercial Competition interests Marketing Financial issues IQC Laboratory resources Practical constraints Service quality Analytical validity Measureme nt Domain precision accuracy Reference methods Reference materials Standarisation sensitivity specificity

Government funding DH / NHS NICE policy, national standards Professions training, best practice, audit Clinicians Scientists Patients CPA / UKAS standards Laboratories comparability safety MHRA EQA Industry trueness, traceability JCTLM, NMIs

Right result Right test Right time Right specimen Right patient Right reference data Right cost QUALITY IN LABORATORY MEDICINE "FIT FOR PURPOSE" Elements of a Quality System Quality assurance all measures taken to (try to) assure quality Internal quality control analytical precision (reproducibility) External quality assessment (EQA) Audit analytical trueness (lack of bias) local appraisal of adherence to (local) guidelines & standards Accreditation external appraisal of adherence to objective professional standards

Do I have a Quality System and do I audit it? Do I have a Quality Manager? Do I have quality specifications for each investigation? Do I have appropriate IQC? Are IQC data reviewed regularly and acted upon in real time? Do I have appropriate internal audit with documented preventative and corrective action? Are adverse incidents appropriately identified, recorded & acted upon? Are all staff appropriately trained? Do I have a complaints log? Do I assess and review customer satisfaction? Triangle 1 - quality specification and customer satisfaction QMS Analysis Customers

Am I using the right method? Do I understand its characteristics and limitations? Are my IQC materials appropriate? Are my calibrators and reagents in date? Do I know who to speak to at the company? Do I have the latest method information? Does the company respond adequately to enquiries? Is my IQC OK in respect of clinical applications and requirements? Is my method correctly classified in the EQA scheme? Does my EQAS performance reflect that of the method group? Triangle 2 - method selection, evaluation and IQC/EQA EQAS Laboratories Manufacturers

Triangle 3 - EQA performance surveillance Oversight Bodies JWG NQAAP SC/SAG EQAS Laboratories Do I understand the role of Steering Committees and Specialist Advisory Groups? Do I understand the role of the NQAAPs and JWG? Is my EQA provider accredited to ISO17043 Are my EQA participation details correct? Is my method classification correct? Do I understand scheme design? Do I get the most out of participation? Am I a poor performer? Do I respond quickly to poor performance correspondence?

Triangle 4 - Accreditation Accrediting Body UKAS EQAS Is my organisation accredited to the appropriate Standard? ISO 15189 for labs ISO 17043 for EQA schemes Laboratories

The Narrative of EQA I am going to talk about: Definitions and nomenclature What is the EQA process? Regulatory systems and structure of the NHS in the UK What does EQA look like in practice? Performance surveillance of Laboratories and postmarket surveillance of kits/methods/products Numbers, numbers and interpretation Reference methods and commutability Scoring systems and Scheme design

30

31

33

34

36

Gender differences Interference in Creatinine assays ~ not some obscure medication or drug, but simple, plain old Glucose This is mentioned in the OFU, but does everyone read these? Are diabetics being over treated for kidney problems that aren t there?

The Narrative of EQA I am going to talk about: Definitions and nomenclature What is the EQA process? Regulatory systems and structure of the NHS in the UK What does EQA look like in practice? Performance surveillance of Laboratories and postmarket surveillance of kits/methods/products Numbers, numbers and interpretation Reference methods and commutability Scoring systems and Scheme design

Folate ~ change in assay from major manufacturer 40

Folate ~ change in assay from major manufacturer 41

Folate ~ change in assay from major manufacturer Finlay MacKenzie s world famous Rainbow Trout Plot! The data is plotted by method across the xaxis. The concentration is on the y-axis. Every result is plotted. The symbol shape is different for numeric and nonnumeric data points. The colour of each symbol represents the interpretation that the participating Laboratory itself has categorised their own result. 42

Folate ~ change in assay from major manufacturer 43

Folate ~ Reference Intervals ~ [with B12 as an other example] 44

[1] [2] Gentamicin The top two plots [1] and [2] are both from the same manufacturer. One has a bias of +4% whilst the other has a bias of +16%. Which one of its two methods does the manufacturer believe to be correct? 45

The Narrative of EQA I am going to talk about: Definitions and nomenclature What is the EQA process? Regulatory systems and structure of the NHS in the UK What does EQA look like in practice? Performance surveillance of Laboratories and post-market surveillance of kits/methods/products Numbers, numbers and interpretation Reference methods and commutability Scoring systems and Scheme design

Clinical Chemistry Candidate Reference Method Procedure for the Quantification of Total Serum Cortisol with LC- MS/MS. Hawley JM, Owen LJ, MacKenzie F, Mussell C, Cowen S, Keevil BG. Clin Chem. 2016 Jan;62(1):262-269.

Progesterone Harmony 48

Gender differences Cortisol The nature of the beast is that since we want to use exciting endogenous levels in the Scheme, the male donations we get in through the door get used for Cortisol (and now General chemistry) so the effect that has always been there was largely overlooked/ignored although my predecessor and some participants were aware of the potential problem 49

Cortisol Lets look at a couple of pools over time Look at the 3 domains that Roche exhibits for Pool C498 on a Youden Plot. The 520/520 group used Gen I for both Distributions. The 390/390 group used Gen II for both Distributions The 520/390 group changed from Gen I to Gen II between Distributions.

Pool Stability each graph is one pool with multiple methods 51

Pool Stability each graph is one method with multiple pools 52

December 2010 53

What-if Mass Spec Candidate Reference Method Target August 2015 54

Mass Spec Field Method Target replaces ALTM July 2017 55

Roche Gen I and Gen II Feb 2016 56

Roche Gen I and Gen II July 2017 57

Summing Up EQA gives information on relative bias If the specimens are commutable and reference methods are available, EQA can give information on absolute bias EQA can give trend data over many years EQA can underpin specificity, sensitivity and standardisation of assay systems EQA can ensure Guidelines are evidence-based and achievable EQA must be independent and scientifically and clinically driven

It s not just about the Quality of the test x x x Other Person Wrong Sample Right Assay Wrong Result Too Late Wrong Place Wrong Outcome A UK NEQAS Pre & Post Analytical Quality Monitoring Service Copyright: UK NEQAS 60

The Narrative of EQA I am going to talk about: Definitions and nomenclature What is the EQA process? Regulatory systems and structure of the NHS in the UK What does EQA look like in practice? Performance surveillance of Laboratories and postmarket surveillance of kits/methods/products Numbers, numbers and interpretation Reference methods and commutability Scoring systems and Scheme design

Performance surveillance ACB June 2010 62

Performance Surveillance Performance surveillance is a professional responsibility In the UK: laboratory Director and staff Scheme Organiser National Quality Assurance Advisory Panel Joint Working Group on Quality Assurance [Medical Director of Trust/hospital] 'Failure' prompts investigation and education, NOT an automatic penalty

"But it's the Instrument's Fault" Increasing reliance on IVDs not a valid excuse for poor performance! In Europe: BS EN 14136:2004 Use of external quality assessment schemes in the assessment of the the performance of in vitro diagnostic examination procedures In the UK: JWG guidelines for EQA scheme organisers in the management of problems with EQA performance of IVDs Scheme Organisers do contact suppliers more likely to be effective?in parallel with contact to users

Manufacturer divergences The bad news individual manufacturers' methods do diverge method principles may also diverge some problems may be specimen-related some manufacturers deny there is a problem denial may last a long time The good news manufacturers do respond (eventually) (proactive) constructive dialogue with UK NEQAS responsiveness increases with experience