PX1 PX1 PERFORMANCE M E T A L WIL T-12

Similar documents
PX400 P L A S T I C PX400 PERFORMANCE WIL T-02

PX800 M E T A L PX800 PERFORMANCE WIL T-08

PX4 P L A S T I C PX4 PERFORMANCE WIL T-02

P400/PX400. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance WIL E-07 REPLACES WIL E-06

EOM PX1500. Engineering Operation & Maintenance. Advanced Series Metal Pump. WIL E-10 Replaces WIL E-09

P400/PX400. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance WIL E-12 REPLACES WIL E-11

P800/PX800. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance WIL E-12 REPLACES WIL E-11

PX1500. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance. WIL E-02 Replaces WIL E-01

P4/PX4. Original Series METAL Pumps. Simplify your process. Engineering Operation & Maintenance. WIL E-07 Replaces WIL E-06

P800/PX800. Advanced Series PLASTIC Pumps. Advance your process. Engineering Operation & Maintenance WIL E-04 TO REPLACE WIL E-03

P8/PX8. Original Series PLASTIC Pumps. Simplify your process. Engineering Operation & Maintenance WIL E-04 TO REPLACE WIL E-03

EOM P800/PX800. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance WIL E-04 REPLACES WIL E-03

EOM PX4. Engineering Operation & Maintenance. Saniflo Hygienic Series Metal Pumps. WIL E-04 TO REPLACE WIL E-03

P800/PX800. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance WIL E-05 REPLACES WIL E-04

EOM PX8. Sanifl o Hygienic Series METAL Pumps. Refine your process. Engineering Operation & Maintenance WIL E-01

EOM PX15. Engineering Operation & Maintenance. Saniflo Hygienic Series Metal Pumps. WIL E-04 TO REPLACE WIL E-03

EOM PX2. Engineering Operation & Maintenance. Saniflo Hygienic Series. WIL E-05 TO REPLACE WIL E-04

EOM. PX2 Saniflo Hygienic Series Metal Pumps. Engineering Operation & Maintenance. WIL E-06 REPLACES WIL E-05

P1/PX1. Original Series METAL Pumps. Simplify your process. Engineering Operation & Maintenance LISTED 79 WIL E-15 REPLACES WIL E-14

EOM. PX420 / PX430 Advanced FIT Metal Pumps. Engineering Operation & Maintenance. REPLACES WIL E-01

PX4. Original Series PLASTIC Pumps. Simplify your process. Engineering Operation & Maintenance WIL E-02 TO REPLACE WIL E-01

FAST & FLEXIBLE EXPERTISE 100% ORDER FULFILLMENT LOW COST PROVIDER

EOM. P1/PX1 Original Series Metal Pump. Engineering Operation & Maintenance. WIL E-16 REPLACES WIL E-15

P400/PX400. Advanced Series PLASTIC Pumps. Advance your process. Engineering Operation & Maintenance WIL E-02 TO REPLACE WIL E-01

A050-1/2 INCH AIR OPERATED double DIAPHRAGM PUMP

S a n i f l o S E R I E S R e f i n e y o u r p r o c e s s

PX810. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance WIL E-01

PX1510. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance WIL E-01

OPERATION MANUAL. ALUMINUM Models 316 S.S. Models AIR-OPERATED DOUBLE DIAPHRAGM PUMPS

Air Amplifiers & SYSTEMS

Pressure on Demand. Air Pressure Amplifiers

OPERATION MANUAL AIR-OPERATED DOUBLE DIAPHRAGM PUMPS 1.5 POLYPROPYLENE PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF40 CLAMPED. A JDA Global Company

brands you trust. DEPA DH Next Generation Air Operated Double Diaphragm Pumps

When the pressure is on, turn to our high-pressure pumps

McFarland TriTan, LLC.

hydro-pac, inc. Low-Pressure Gas Compressors 1500 to 6000 PSI

CHAPTER 3 : AIR COMPRESSOR

PRODUCT DATA SHEET. Description

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

Model 10. Low-Medium Pressure Reducing Regulator

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

2 I All-Flo Pump Co.

2 I All-Flo Pump Co.

1200 Series Pressure Regulators

Air Eliminators and Combination Air Eliminators Strainers

CASH VALVE TYPE KP BACK PRESSURE VALVES

Liquid Level Controllers

PENBERTHY SERIES LM, ELL, FL, GL, GH, U, L AND 2NC FOR PUMPING GASES

Oil & gas. Safe Reliable. Pumps. Pumps. CSA Accessories. Toll Free: Int'l:

Sullair Air Systems. *Assessment of the market for compressed air efficiency services. Technical report, U.S. Department of Energy, June 2001

SERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL.

Full Range Pressure Compensating Variable Flow Control

Self-priming makes priming unnecessary Exhausts the air inside the suction pipe to suck up liquid. Air operated type.

Air Nozzles and Jets. Air Nozzles and Jets. Engineered Air Nozzles and Jets reduce noise levels and air costs.

RCD - Ultra-Rugged Differential Pressure Flowmeter

AHD/AHS SERIES. Air-Operated Double-Diaphragm Pumps. Where Innovation Flows. almatec.de

Grundfos GT TANK Keep it safe

Moyno ERT Power Sections. Operational Guidelines

TECHNICAL DATA. Page 1 of 12

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

Clinker Cooling- Making the most out of your energy

since 1928 ALBIN PUMP AD AIR OPERATED FLOATING DIAPHRAGM PUMPS INSTRUCTION MANUAL AD Instruction Manual-2011EE-GB.indd 1 25/07/11 09:45

TECHNICAL DATA Q= C. Table 1 - Specifications

PRO-50 Instrument Supply Regulator

FILTER BYPASS CONTROL

SEMI FIXED/PORTABLE LINE PROPORTIONERS SLP NPR270

KMT Waterjet Systems Inc.

Simple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18

OptiFlo Air operated double diaphragm pumps

PRESSURE TANKS HANDLING & INSTALLATION INSTRUCTIONS INSTALLATION MANUAL CONTROL VALVES

OPERATOR S MANUAL

Process Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order

Operating Instructions Models 36200, , 46200, Hydrostatic Test Pumps

PDF // GRUNDFOS SUBMERSIBLE PUMP SPECIFICATIONS DOWNLOAD

Noth American 7347 High Pressure Gas Regulators

Diaphragm Vacuum Pumps and Compressors with Group C & D Explosion-Proof Motors Types: UN026, UN726, UN035, UN860

ALE-40. R06 Miniature Brass Body Regulator. Water and Compressed Air Service 1/8" and 1/4" PTF Port Sizes. Air line equipment.

Type 1190 Low-Pressure Gas Blanketing Regulator

Multiple Pressure Booster Systems With Variable Speed Controller Type BL

Practical Guide. By Steven T. Taylor, P.E., Member ASHRAE

KM/31000 (Stainless steel end plates) Air bellows, single acting

Installation Operation Maintenance

Model PRS-07i. Stainless Steel Low Pressure, In-Line Pressure Regulator (Reducing Valve)

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

TECHNICAL DATA. Trimpac 244a. September 16, 2013

Features. General application. Technical data

POP Safety Valve. POP Safety Valve INTRODUCTION DEFINITIONS

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

Geotech 1.66 Reclaimer

Displacement 12, , Maximum flow rate (at 1450 rpm) bar.

Engineered Air Nozzles reduce noise levels and air costs.

VERTICAL BLADDER TANK

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"

250 (9.84) 170 (6.69) 225 (8.85) 75 (2.95) 300 (11.81)

Dean Pump Self-Priming Chemical Process Pumps

pumping gases JET PUMP TECHNICAL DATA

TYPE 3710 CARTRIDGE SPLIT SEAL Technical Specification

VACUUM REGULATORS CONTENTS

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

Transcription:

PX1 M E T A L PX1 PERFORMANCE WIL-10300-T-12

Pro-Flo X TM Operating Principal The Pro-Flo X air distribution system with the revolutionary Efficiency Management System (EMS) offers flexibility never before seen in the world of AODD pumps. The patent-pending EMS is simple and easy to use. With the turn of an integrated control dial, the operator can select the optimal balance of flow and efficiency that best meets the application needs. Pro-Flo X provides higher performance, lower operational costs and flexibility that exceeds previous industry standards. AIR CONSUMPTION $$$ Turning the dial changes the relationship between air inlet and exhaust porting. Each dial setting represents an entirely different flow curve Pro-Flo X pumps are shipped from the factory on setting 4, which is the highest flow rate setting possible Moving the dial from setting 4 causes a decrease in flow and an even greater decrease in air consumption. When the air consumption decreases more than the flow rate, efficiency is improved and operating costs are reduced. WILDEN PUMP & ENGINEERING, LLC 2 PX1 Performance

HOW TO USE THIS EMS CURVE Example 1 SETTING 4 PERFORMANCE CURVE EMS CURVE Figure 1 Figure 2 flow multiplier Example data point = 8.2 GPM Example data point = air multiplier 0.58 0.48 This is an example showing how to determine flow rate and air consumption for your Pro-Flo X pump using the Efficiency Management System (EMS) curve and the performance curve. For this example we will be using 4.1 bar (60 psig) inlet air pressure and 2.8 bar (40 psig) discharge pressure and EMS setting 2. Step 1: Identifying performance at setting 4. Locate the curve that represents the flow rate of the pump with 4.1 bar (60 psig) air inlet pressure. Mark the point where this curve crosses the horizontal line representing 2.8 bar (40 psig) discharge pressure. (Figure 1). After locating your performance point on the flow curve, draw a vertical line downward until reaching the bottom scale on the chart. Identify the flow rate (in this case, 8.2 gpm). Observe location of performance point relative to air consumption curves and approximate air consumption value (in this case, 9.8 scfm). Step 2: Determining flow and air X Factors. Locate your discharge pressure (40 psig) on the vertical axis of the EMS curve (Figure 2). Follow along the 2.8 bar (40 psig) horizontal line until intersecting both flow and air curves for your desired EMS setting (in this case, setting 2). Mark the points where the EMS curves intersect the horizontal discharge pressure line. After locating your EMS points on the EMS curve, draw vertical lines downward until reaching the bottom scale on the chart. This identifies the flow X Factor (in this case, 0.58) and air X Factor (in this case, 0.48). Step 3: Calculating performance for specific EMS setting. Multiply the flow rate (8.2 gpm) obtained in Step 1 by the flow X Factor multiplier (0.58) in Step 2 to determine the flow rate at EMS setting 2. Multiply the air consumption (9.8 scfm) obtained in Step 1 by the air X Factor multiplier (0.48) in Step 2 to determine the air consumption at EMS setting 2 (Figure 3). Figure 3 8.2 gpm (flow rate for Setting 4).58 4.8 gpm (Flow rate for setting 2) 9.8 scfm.48 4.7 scfm (Flow X Factor setting 2) (air consumption for setting 4) (Air X Factor setting 2) (air consumption for setting 2) The flow rate and air consumption at Setting 2 are found to be 18.2 lpm (4.8 gpm) and 7.9 Nm 3 /h (4.7 scfm) respectively. PX1 Performance 3 WILDEN PUMP & ENGINEERING, LLC

HOW TO USE THIS EMS CURVE Example 2.1 SETTING 4 PERFORMANCE CURVE EMS CURVE EMS Flow Settings 1 & 2 Figure 4 Example data point = 10.2 gpm 0.49 flow multiplier Figure 5 This is an example showing how to determine the inlet air pressure and the EMS setting for your Pro-Flo X pump to optimize the pump for a specific application. For this example we will be using an application requirement of 18.9 lpm (5 gpm) flow rate against 2.8 bar (40 psig) discharge pressure. This example will illustrate how to calculate the air consumption that could be expected at this operational point. DETERMINE EMS SETTING Step 1: Establish inlet air pressure. Higher air pressures will typically allow the pump to run more efficiently, however, available plant air pressure can vary greatly. If an operating pressure of 6.9 bar (100 psig) is chosen when plant air frequently dips to 6.2 bar (90 psig) pump performance will vary. Choose an operating pressure that is within your compressed air systems capabilities. For this example we will choose 4.1 bar (60 psig). Step 2: Determine performance point at setting 4. For this example an inlet air pressure of 4.1 bar (60 psig) inlet air pressure has been chosen. Locate the curve that represents the performance of the pump with 4.1 bar (60 psig) inlet air pressure. Mark the point where this curve crosses the horizontal line representing 2.8 bar (40 psig) discharge pressure. After locating this point on the flow curve, draw a vertical line downward until reaching the bottom scale on the chart and identify the flow rate. In our example it is 38.6 lpm (10.2 gpm). This is the setting 4 flow rate. Observe the location of the performance point relative to air consumption curves and approximate air consumption value. In our example setting 4 air consumption is 24 Nm 3 /h (14 scfm). See figure 4. Step 3: Determine flow X Factor. Divide the required flow rate 18.9 lpm (5 gpm) by the setting 4 flow rate 38.6 lpm (10.2 gpm) to determine the flow X Factor for the application. 5 gpm / 10.2 gpm = 0.49 (flow X Factor) Step 4: Determine EMS setting from the flow X Factor. Plot the point representing the flow X Factor (0.49) and the application discharge pressure 2.8 bar (40 psig) on the EMS curve. This is done by following the horizontal 2.8 bar (40 psig) psig discharge pressure line until it crosses the vertical 0.49 X Factor line. Typically, this point lies between two flow EMS setting curves (in this case, the point lies between the flow curves for EMS setting 1 and 2). Observe the location of the point relative to the two curves it lies between and approximate the EMS setting (figure 5). For more precise results you can mathematically interpolate between the two curves to determine the optimal EMS setting. For this example the EMS setting is 1.8. WILDEN PUMP & ENGINEERING, LLC 4 PX1 Performance

HOW TO USE THIS EMS CURVE Example 2.2 SETTING 4 PERFORMANCE CURVE EMS CURVE EMS Air Settings 1 & 2 Figure 6 Example data point = 10.2 gpm Example data point = 0.40 air multiplier Figure 7 Determine air consumption at a specific EMS setting. Step 1: Determine air X Factor. In order to determine the air X Factor, identify the two air EMS setting curves closest to the EMS setting established in example 2.1 (in this case, the point lies between the air curves for EMS setting 1 and 2). The point representing your EMS setting (1.8) must be approximated and plotted on the EMS curve along the horizontal line representing your discharge pressure (in this case, 40 psig). This air point is different than the flow point plotted in example 2.1. After estimating (or interpolating) this point on the curve, draw a vertical line downward until reaching the bottom scale on the chart and identify the air X Factor (figure 7). Step 2: Determine air consumption. Multiply your setting 4 air consumption (14 scfm) value by the air X Factor obtained above (0.40) to determine your actual air consumption. 14 scfm x 0.40 = 5.6 SCFM In summary, for an application requiring 18.9 lpm (5 gpm) against 2.8 bar (40 psig) discharge pressure, the pump inlet air pressure should be set to 4.1 bar (60 psig) and the EMS dial should be set to 1.8. The pump would then consume 9.5 Nm 3 /h (5.6 scfm) of compressed air. For this example the air X Factor is 0.40 PX1 Performance 5 WILDEN PUMP & ENGINEERING, LLC

PERFORMANCE PX1 METAL RUBBER-FITTED SETTING 4 PERFORMANCE CURVE EMS CURVE TECHNICAL DATA Height...........................224 mm (8.8 ) Width............................208 mm (8.2 ) Depth............................221 mm (8.7 ) Ship Weight............. Aluminum 6 kg (13 lbs.)................ 316 Stainless Steel 9 kg (20 lbs.) Air Inlet.......................... 13 mm (1/2 ) Inlet............................. 13 mm (1/2 ) Outlet............................ 13 mm (1/2 ) Suction Lift.....................5.9 m Dry (19.3 ).............................. 8.0 m Wet (26.1 ) Disp. Per Stroke............... 0.09 l (0.023 gal.) 1 Max. Flow Rate..............62.5 lpm (16.5 gpm) Max. Size Solids................. 1.6 mm (1/16 ) 1 Displacement per stroke was calculated at 4.8 bar (70 psig) air inlet pressure against a 2 bar (30 psig)head pressure. The Efficiency Management System (EMS) can be used to optimize the performance of your Wilden pump for specific applications. The pump is delivered with the EMS adjusted to setting 4, which allows maximum flow. The EMS curve allows the pump user to determine flow and air consumption at each EMS setting. For any EMS setting and discharge pressure, the X factor is used as a multiplier with the original values from the setting 4 performance curve to calculate the actual flow and air consumption values for that specific EMS setting. Note: you can interpolate between the setting curves for operation at intermediate EMS settings. EXAMPLE A PX1 metal, Rubber-fitted pump operating at EMS setting 4, achieved a flow rate of 56.8 lpm (15.0 gpm) using 35.7 Nm 3 /h (21.0 scfm) of air when run at 5.5 bar (80 psig) air inlet pressure and 1.4 bar (20 psig) discharge pressure (See dot on flow chart). The end user did not require that much flow and wanted to reduce air consumption at his facility. He determined that EMS setting 2 would meet his needs. At 1.4 bar (20 psig) discharge pressure and EMS setting 2, the flow X factor is.66 and the air X factor is.48. Multiplying the original setting 4 values by the X factors provides the setting 2 flow rate of 37.5 lpm (9.9 gpm) and an air consumption of 17.2 Nm 3 /h (10.1 scfm). The flow rate was reduced by 34% while the air consumption was reduced by 52%, thus providing increased efficiency. For a detailed example for how to set your EMS, see beginning of performance curve section. Caution: Do not exceed 8.6 bar (125 psig) air supply pressure. WILDEN PUMP & ENGINEERING, LLC 6 PX1 Performance

PERFORMANCE PX1 METAL TPE-FITTED SETTING 4 PERFORMANCE CURVE EMS CURVE TECHNICAL DATA Height...........................224 mm (8.8 ) Width............................208 mm (8.2 ) Depth............................221 mm (8.7 ) Ship Weight............. Aluminum 6 kg (13 lbs.)................ 316 Stainless Steel 9 kg (20 lbs.) Air Inlet.......................... 13 mm (1/2 ) Inlet............................. 13 mm (1/2 ) Outlet............................ 13 mm (1/2 ) Suction Lift.....................5.7 m Dry (18.7 ).............................. 9.3 m Wet (30.6 ) Disp. Per Stroke............... 0.11 l (0.029 gal.) 1 Max. Flow Rate..............62.8 lpm (16.6 gpm) Max. Size Solids................. 1.6 mm (1/16 ) 1 Displacement per stroke was calculated at 4.8 bar (70 psig) air inlet pressure against a 2 bar (30 psig)head pressure. The Efficiency Management System (EMS) can be used to optimize the performance of your Wilden pump for specific applications. The pump is delivered with the EMS adjusted to setting 4, which allows maximum flow. The EMS curve allows the pump user to determine flow and air consumption at each EMS setting. For any EMS setting and discharge pressure, the X factor is used as a multiplier with the original values from the setting 4 performance curve to calculate the actual flow and air consumption values for that specific EMS setting. Note: you can interpolate between the setting curves for operation at intermediate EMS settings. EXAMPLE A PX1 metal, TPE-fitted pump operating at EMS setting 4, achieved a flow rate of 56.0 lpm (14.8 gpm) using 29.7 Nm3/h (17.5 scfm) of air when run at 4.8 bar (70 psig) air inlet pressure and 0.7 bar (10 psig) discharge pressure (See dot on flow chart). The end user did not require that much flow and wanted to reduce air consumption at his facility. He determined that EMS setting 1 would meet his needs. At 0.7 bar (10 psig) discharge pressure and EMS setting 1, the flow X factor is.32 and the air X factor is.14. Multiplying the original setting 4 values by the X factors provides the setting 1 flow rate of 17.8 lpm (4.7 gpm) and an air consumption of 4.2 Nm 3 /h (2.5 scfm). The flow rate was reduced by 68% while the air consumption was reduced by 86%, thus providing increased efficiency. For a detailed example for how to set your EMS, see beginning of performance curve section. Caution: Do not exceed 8.6 bar (125 psig) air supply pressure. PX1 Performance 7 WILDEN PUMP & ENGINEERING, LLC

PERFORMANCE PX1 METAL PTFE-FITTED SETTING 4 PERFORMANCE CURVE EMS CURVE TECHNICAL DATA Height...........................224 mm (8.8 ) Width............................208 mm (8.2 ) Depth............................221 mm (8.7 ) Ship Weight............. Aluminum 6 kg (13 lbs.)................ 316 Stainless Steel 9 kg (20 lbs.) Air Inlet.......................... 13 mm (1/2 ) Inlet............................. 13 mm (1/2 ) Outlet............................ 13 mm (1/2 ) Suction Lift.....................4.7 m Dry (15.3 ).............................. 8.0 m Wet (26.1 ) Disp. Per Stroke............... 0.09 l (0.024 gal.) 1 Max. Flow Rate..............60.9 lpm (16.1 gpm) Max. Size Solids................. 1.6 mm (1/16 ) 1 Displacement per stroke was calculated at 4.8 bar (70 psig) air inlet pressure against a 2 bar (30 psig)head pressure. The Efficiency Management System (EMS) can be used to optimize the performance of your Wilden pump for specific applications. The pump is delivered with the EMS adjusted to setting 4, which allows maximum flow. The EMS curve allows the pump user to determine flow and air consumption at each EMS setting. For any EMS setting and discharge pressure, the X factor is used as a multiplier with the original values from the setting 4 performance curve to calculate the actual flow and air consumption values for that specific EMS setting. Note: you can interpolate between the setting curves for operation at intermediate EMS settings. EXAMPLE A PX1 metal, PTFE-fitted pump operating at EMS setting 4, achieved a flow rate of 18.9 lpm (5 gpm) using 8.83 Nm3/h (5.2 SCFM) of air when run at 3.2 bar (47 psig) air inlet pressure and 2.8 bar (40 psig) discharge pressure (See dot on flow chart). The end user did not require that much flow and wanted to reduce air consumption at his facility. He determined that EMS setting 3 would meet his needs. At 2.8 bar (40 psig) discharge pressure and EMS setting 3, the flow X factor is.86 and the air X factor is.76. Multiplying the original setting 4 values by the X factors provides the setting 3 flow rate of 16.3 lpm (4.3 gpm) and an air consumption of 6.8 Nm 3 /h (4.0 scfm). The flow rate was reduced by 14% while the air consumption was reduced by 24%, thus providing increased efficiency. For a detailed example for how to set your EMS, see beginning of performance curve section. Caution: Do not exceed 8.6 bar (125 psig) air supply pressure. WILDEN PUMP & ENGINEERING, LLC 8 PX1 Performance

NOTES PX1 Performance 9 WILDEN PUMP & ENGINEERING, LLC

22069 Van Buren St. Grand Terrace, CA 92313-5651 Tel 909-422-1730 Fax 909-783-3440 www.wildenx.com Take control of your process today with