Owners Manual. Models 4420BF1U & 4420BF1L Floor Mounted Bi-Level Bottle Filler Tubular Fountain

Similar documents
Owners Manual Models 4430BF3, 4430BF2 & 4430BF1 Floor Mounted Tri-Level Bottle Filling Tubular Fountain

PAGE (Rev. A - 06/17)

Halsey Taylor Owners Manual

Installation/Care/Use Manual Soft Sides Fountains with FLEXI-GUARD

Halsey Taylor Owners Manual

Halsey Taylor Owners Manual

SWIRLFLO Refrigerated fountains with FLEXI-GUARD

Installation/Care/Use Manual

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

Owners Manual Bottle Filler Freeze Resistant Tubular Fountain & Pet Fountain with 98837C Dual Valve Control Assembly

Halsey Taylor Owners Manual STOP!

INSTALLATION, CARE & USE MANUAL. EMASMB & LMASMB Surface Mount Bottle Filling Stations

Installation and Use Manual

INSTALLATION INSTRUCTIONS FOR GRT75-PF-RFS PET FOUNTAIN

LK4420BFFR - FTN, 4420BFFR - FTN. Owners Manual

Installation Instructions

INSTALLATION INSTRUCTIONS 1/2 THERMOSTATIC VALVE AND TRIM

Installation Instructions

BASIN AND WALL MIXER INSTALLATION INSTRUCTIONS

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

INSTALLATION INSTRUCTIONS

TECHNICAL DATA. Trimpac 244a. September 16, 2013

Anti-flood device Model B-1

TECHNICAL DATA ANTI-FLOOD DEVICE MODEL B-1 1. DESCRIPTION

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

V48 Series 3-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

V43 Pressure Actuated Water Regulating Valve

Sterisil Ac+ Installation & Operating Manual

COMPACT TRIPLE WALL OUTLET STATION MODEL INSTALLATION AND OPERATING INSTRUCTIONS

TECHNICAL DATA. Trimpac 257a. September 16, 2013

DS06D,G Dial Set Pressure Regulating Valve

Floor Drinking Systems

AIR DISTRIBUTOR. PART NUMBER (Including, but not inclusive) AD28483-_ALB, AD28563-_ALB, AD36097-_ALB, AD36098-_ALB, AD28485-_ALB

Installation Instructions

TECHNICAL DATA. Trimpac 256a. October 31, 2013

G92 Series BASOTROL Automatic Pilot Gas Valve

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

Pressure Balance Trim

V46 Series 2-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

Installation Instructions for NP100 Series Nitrogen Control Panels

Installing ASI Umbilical Delivery Systems

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

TECHNICAL DATA. Page 1 of 8. model f /2 (dn40) & 2 (dn50)

SEQUENTIAL SHOWER VALVE INSTRUCTION MANUAL PLEASE LEAVE THIS MANUAL WITH THE END USER

DS05C,D,G Dial Set Pressure Regulating Valves

SPECIFICATIONS. Outdoor Tubular Bottle Filling Station Freeze Resistant Dual Station. MODEL LK4420BF1UFRK and MODEL LK4420BF1LFRK

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment

Instruction Manual - Diaframless TM Ejector Chlorine, Sulfur Dioxide and Ammonia

TECHNICAL INSTRUCTIONS

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

Installation and Maintenance Manual. Compact Medical Gas Outlets

PEDESTAL MOUNTED EMERGENCY EYE & EYE/FACE WASH

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

SINGER MODEL 106/206-RPS-L&H

Pressure Dump Valve Service Kit for Series 2300 Units

TECHNICAL DATA. Page 1 of 12

User Manual for the Mars Calibration Bench

Operation Manual Air Saver Unit ASV5000 Series

Model: 43T. Bermad Pressure Relief Valve

TECHNICAL DATA CAUTION

TECHNICAL DATA CAUTION

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

IAPMO GUIDE CRITERIA FOR BALL VALVES IAPMO IGC PURPOSE

V146 Series 2-Way Pressure-Actuated Water-Regulating Valves

PRO SINK -R 1 and 2. Dilution system CONTENTS

AIR/OVER HYDRAULIC JACK 20 TON

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

INSTRUCTION MANUAL. January 23, 2003, Revision 0

D05 Pressure Regulating Valves

CAPITAL CONTROLS SERIES NXT3000

Model VR6 System. Installation, Operation & Maintenance

LUDLUM MODEL 239-1F FLOOR MONITOR. Revised December 2010

Bermad Pressure Reducing. Model: 42T

TECHNICAL DATA. Trimpac 247a_Euro. September 16, 2013

LAKOS Waterworks. PWC Series Sand Separators. Installation & Operation Manual LS-829 (10/12)

Your safety and the safety of others are very important.

Speed control assembly model A-1

Instruction Manual O-Ring Ejector Chlorine & Sulfur Dioxide to 500 PPD (10 kg/h)

3.5 litr es per INSTALLATION INSTRUCTIONS. Avon 21 Self-closing taps (Push button) B0992AA Self-closing basin pillar tap

Installation, Operation, and Maintenance Manual

Budget Range Operators Handbook

Twin & Triple Control Concealed Thermostatic Shower Valve

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

Engineering Excellence. Installation Guide

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

WALL MOUNTED EMERGENCY EYE & EYE/FACE WASH HAND OPERATED

HORNE T109A/306A/307A THERMOSTATIC SHOWER VALVE FOR SURFACE MOUNTING WITH TIMED FLOW CONTROL INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Combination Air Valve Model

TECHNICAL DATA DELUGE VALVE, MODEL F-1 STRAIGHT THROUGH STYLE

INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235)

Booster Pump PB4-60 Replacement Kits

Propane Conversion Kit Instructions

INSTALLATION and OPERATION INSTRUCTIONS

TEMPERATURE STABILISED THERMOSTATIC SHOWER PANEL

Bermad Model:

FlashGARD HP Reverse Osmosis Filtration System Model Number FSTMO75 Part Number

INSTALLATION GUIDELINES

Pressure Dump Valve Service Kit for Series 3000 Units

Transcription:

Owners Manual Models 4420BF1U & 4420BF1L Floor Mounted Bi-Level Bottle Filler Tubular Fountain Models (LK)4420BF1U* Models (LK)4420BF1L* INSTALLER 4420BF Fountains are among the easiest to install Fountains on the market today. To assure you install these models easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL, AND OTHER APPLICABLE CODES. After installation, leave these instructions with the Fountain for future reference. PAGE 1 98644C (Rev. D - /)

INSTALLATION INSTRUCTIONS IMPORTANT ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON IMPORTANT! INSTALLER PLEASE NOTE. THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM. 1. This fountain is to be mounted on a smooth, flat, finished surface with adequate support structure. NOTE: Mounting structure must be capable of supporting 300 lb. load on fountain. 2. Refer to rough-in for plumbing. 3. Install shut-off valve on water supply. (Valve not furnished) 4. Locate and install fountain using 3/8" minimum fasteners. (Fasteners not furnished) 5. Prior to installing the bottle filler to the center mounting position of fountain, install the drain pipe (Item #11) by positioning the short end of drain pipe through mounting plate of bottle filler. Install filler onto fountain and secure with supplied mounting hardware. 6. Prior to installing the bottle filler to the arm mount of fountain, insert the drain pipe (Item #10) into the arm tunnel and adjust drain to lean to the left side of arm when facing button. Install bottle filler to arm being sure drain tube is above mounting plate of filler. Install filler onto fountain and secure with supplied mounting hardware. 7. Connect water supply and fountain drain. Connect drain waste "Tee" to fountain drain tubes. Connect outlet of "Tee" to drainage system. Connect Bottle Filler water line to regulator with the supplied 3/8" to 1/4" reducing fitting. Water connection and drain must comply with local codes. 8. Turn on water supply and check all connections for leaks. CAUTION: This fountain is rated for inlet water pressure of 20-105 PSI. A pressure reducing regulator should be used if the inlet water supply exceeds 105 PSI. Any damage caused by reason of connecting this product to supply line pressures lower than 20 PSI or higher than 105 PSI is not covered by warranty. 9. Water supply 3/8" O.D. unplated copper tube. Waste 1-1/2" IPS. Contractor to supply waste trap and service stop valve in accordance with local code. 10. Connecting lines to be made of unplated copper and should be thoroughly flushed to remove all foreign matter before being connected to fountain. This fountain is manufactured in such a manner that it does not in any way cause taste, odor, color, or sediment problems. 11. Connect fountain to supply line with a shut-off valve and install a 3/8" unplated copper water line between the valve and the cooler. Remove any burrs from outside of water line. Push the tubes straight into the fittings until they reach a positive stop, approximately 3/4" (See Fig. 2). DO NOT SOLDER TUBES INSERTED INTO PLASTIC FITTINGS AS DAMAGE TO THE O-RINGS MAY RESULT. 98644C (Rev. D - /) PAGE 2

O 1/ 13 2" mm (6 PL) O 10 25 " 4mm O 30 " 5mm B.C. O 14" 356mm 2 7/8" 73mm B 42 3/16" 1072mm (38mm) 1-1/2" DRAIN 40 5/16" 1025mm C 19" 483mm 30" 762mm 1/8" 587mm A 8" 203mm FINISHED FLOOR LEGEND A = 3/8" O.D. UNPLATED COPPER TUBE CONNECT - SHUT OFF VALVE BY OTHERS B = ACCESS PANEL ( 8" X 10" ) C = REMOVABLE BOTTOM COVER 3" 76mm 14 9/16" 371mm 37" 940mm 27" 686mm 57" 1448mm 4420BF1U PAGE 3 98644C (Rev. D - /)

O 1/ 13 2 m " m (6 PL) 3" 76mm O 30 " 5mm B.C. O 14" 356mm 14 9/16" 371mm B 64" 1626mm (38mm) 1-1/2" DRAIN 44" 1118mm C 19" 483mm 30" 762mm 1/8" 587mm A 8" 203mm FINISHED FLOOR LEGEND A = 3/8" O.D. UNPLATED COPPER TUBE CONNECT - SHUT OFF VALVE BY OTHERS B = ACCESS PANEL ( 8" X 10" ) C = REMOVABLE BOTTOM COVER 3" 76mm 14 9/16" 371mm 27" 686mm 37" 940mm 57" 1448mm O 10" 25 4mm 4420BF1L 98644C (Rev. D - /) PAGE 4

14 & 2 & 17 19 & 19 18 & 25 26 4 1 21 ARM ONLY 10 11 21 3 4 1 20 13 or 16 20 BASIN 9 & 22 FIG. 4 22 Vandal-Resistant Bubbler FIG. 1 6 PAGE 5 98644C (Rev. D - /)

TROUBLE SHOOTING AND MAINTENANCE ACTUATION OF QUICK CONNECT WATER FITTINGS: Fountain is provided with lead-free connectors which utilize an o-ring water seal. To remove tubing from the fitting, relieve water pressure, push in on the gray collar while pulling on the tubing. (see Fig.3) To insert tubing, push tube straight into fitting until it reaches a positive stop, approximately 3/4". 1/4" O.D. TUBE WATER INLET TO COOLER 3/8" O.D. UNPLATED COP- PER TUBE CONNECT COLD WATER SUPPLY BUILDING WATER INLET FIG. 2 NOTE: WATER FLOW DIRECTION SERVICE STOP (NOT FURNISHED) OPERATION OF QUICK CONNECT FITTINGS SIMPLY PUSH IN IN TUBE IS SECURED PUSH IN COLLET TUBE TO ATTACH IN IN POSITION TO RELEASE TUBE FIG. 3 A B C PUSHING TUBE IN BEFORE PULLING IT OUT HELPS TO RELEASE TUBE ITEMIZED PARTS LIST ITEM NO. PART NO. DESCRIPTION 1 2 3 4 5 6 7 8 9 10 11 13 14 16 17 18 19 20 21 22 25 26 28467C 28955C* 40551C 45464C 45832C* 45833C 45476C 55996C 66346C 66816C 668C 97446C 98530C 98532C 98677C 98678C 98679C 98680C 98681C 98682C 98683C 98684C 98685C 98686C P05031 45931C Basin Cover - Round Plate Tailpipe Drain Plug 1-1/2" Access Panel Bottom Cover Drain Tube In - Line Strainer Drain Tube Tube - Drain (Arm Only) Tube - Drain Kit - Bubbler (VR) Kit - Regulator W/Spring Kit - "O" Rings and Fittings Kit - Gasket Kit - 1.0 GPM Regulator (BF Only) Kit - Nozzle Kit - Aerator Kit - Bottle Filler Trim Kit - Push Button Kit - Plastic Drain Kit - 90 Plastic Drain Kit - 4400 Series Hardware Kit - Bottle Filler Waterway Aerator Outdoor Bottle Filler Drain Plug *select color option to complete part number *FINISH COLOR OPTIONS Choose color option to complete your model number, add as suffix example: 4420BFEVG Matte finish: Evergreen = EVG Gloss finish: Beige = BGE Gray = GRY Terracotta = TER Black = BLK Orange = ORN White = WHT Blue = BLU Purple = PUR Yellow = YLW Brown = BRN Red = RED FIG. 4 STREAM HEIGHT ADJUSTMENT: Stream height is factory set at 35 PSI. If supply pressure varies greatly from this, insert a small straight bladed screwdriver through the access hole in the center of the push button and turn the adjustment screw. Clockwise adjustment will raise the stream and counterclockwise adjustment will lower the stream. For best adjustment, the stream should be approximately 1 1/2" above the top of the bubbler. (See Fig. 4) 5 5 7 See Fig. 4 8 8 PRINTED IN U.S.A. Halsey Taylor halseytaylor.com Elkay elkay.com 98644C (Rev. D - /) FOR PARTS CONTACT YOUR LOCAL DISTRIBUTOR OR CALL TECHNICAL SERVICES AT 1.800.834.4816 2222 CAMDEN COURT, OAK BROOK, ILLINOIS 605 PAGE 6