RESIDENTIAL REGULATORS

Similar documents
RELIEF VALVES. V Series. Process Management TM. Type V/20-2. Type V/50. Type V/60

PRESSURE REGULATORS. Type A/140. Process Management TM

PRESSURE REGULATORS. Type B/240. Process Management TM

RELIEF VALVES. V Series. Process Management TM. Type V/20-2. Type V/50. Type V/60

SLAM-SHUT VALVES. Type BM5. Process Management TM

RELIEF VALVES. Type VS- FL. Process Management TM

T208VR Series Tank Blanketing Vacuum Regulator

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

64 Series Pressure Reducing Regulators

Type PRX/120, PRX/125, PRX-AP/120, PRX-AP/125, PRX/181, PRX/182, PRX/131 and PRX-AP/131 Pilots

1805 Series Relief Valves

SLAM-SHUT VALVES. Type BM6X. Process Management TM

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

Pressure ranges and accuracy classes for outlet pressure and safety devices

Type R622 Pressure Reducing Regulator

1805 Series Relief Valves

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

MEGR-1912 Instruction Manual

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

1305 Series Pressure Reducing Regulators

CASH VALVE TYPE KP BACK PRESSURE VALVES

RTG 25. Introduction

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

1800CPB2 Service Regulators Maximum Inlet Pressure 125 PSIG

Types 627W and 627WH Direct-Operated Pressure Reducing Liquid Regulators

CP200 Series Commercial / Industrial Pressure- Loaded Pressure Reducing Regulator

Type EZH Relief or Backpressure Regulator

Y692VB Series Vacuum Breaker

RB 4700 Commercial & Industrial Regulator

1800CPB2 Service Regulators

1800CPB2 Pilot-Loaded Service Regulators

Types S100K and S102K Pressure Regulators

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

Type OS/66 Slam-Shut Controller

Type HSR Pressure Reducing Regulator for Residential, Commercial, or Industrial Applications

Type Cronos Pressure Reducing Regulator

RB Series Regulating System

1800C and 1800C-HC Service Regulators

Type ACE97. Introduction. Installation. P.E.D. Categories. Specifications. Overpressure Protection. Installation Guide English May 2002

S300 Series. Valve Link. Features. Fisher Controls

Precision and Instrument Regulators 1/4" port size

INJECTION ODORIZING SYSTEMS : DOSAODOR TYPE

SLAM-SHUT VALVE. Type OSE CONTENTS INTRODUCTION CHARACTERISTICS. Scope of Manual. Material. Product Description. Connections

Types S108K and S109K Pressure Reducing Regulators with Integral Slam-Shut Device

Type PS/79-1 and PS/79-2

Type EZL Pressure Reducing Regulator for Low Differential Pressure Applications

Type EZL Pressure Reducing Regulator for Low Differential Pressure Applications

Type 299 Pressure Reducing Regulators

RTG 311 pressure regulators are included within the direct acting and balanced valve regulator class.

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

PRO-50 Instrument Supply Regulator

RR 16 Commercial & Industrial Regulator

MEGR-1627 Instruction Manual

Dival 500 Pressure Regulators

971 Series Pressure Reducing Regulators

627 Series Pressure Reducing Regulators

1301 Series High-Pressure Regulators

Filling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series

Models 461-S, 461-8S and S Regulators. R-1330 Rev. 7

SR100 Series Service Regulators. Technical Bulletin

Norval Pressure regulator

Type ACE95jr Tank Blanketing Valve

General. Rugged, Reliable with Value-added Features. Pipe Sizes. Temperature Limits. Spring Ranges. Buried Service. Increased Outlet Pipe Sizes

V DFX Series. Direct-Operated Tank Blanketing Regulator Manual D103808X012

Types 749B and R130 Changeover Manifolds

ALE-40. R06 Miniature Brass Body Regulator. Water and Compressed Air Service 1/8" and 1/4" PTF Port Sizes. Air line equipment.

VSX4 Series Slam-Shut Device

Model 1800 PFM Series Regulator. Technical Bulletin

Pilot-Operated Relief Valves

Model 1800 PFM Series Regulator For Constant Outlet Pressure Precise Fixed Factor Measurement From 0.5 to 30 PSIG

Dival 600. Pressure Regulators

Safety Shut-off Valve SSV

Types 95L and 95H Pressure Regulators

RR 16 Commercial & Industrial Regulator

MODEL 240 GAS PRESSURE REGULATOR

OBSOLETE DOCUMENT. VSX4 Series Slam-Shut Device. VSX4 Series. Contents. Introduction. Scope of the Manual. Product Description. !

RELIABLE PROTECTION FOR A WIDE RANGE OF RESIDENTIAL, COMMERCIAL AND INDUSTRIAL APPLICATIONS. water pressure reducing valves

SPRING-LOADED GAS PRESSURE REGULATOR

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide

TESCOM 50-4X Series Safety, Installation & Start-Up Procedures

Type OS/80X, OS/84X and OS/88X Slam-Shut Controller

Gas Pressure Regulator HON 300

Model Series 62 Constant Differential Relay

VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators

66 Series Direct-Operated Regulators and Vacuum Service Equipment

VALVES HIDROMATIC VALVE.

Fisher Lever Lock Handlever Actuators for POSI SEAL A81 Rotary Valves

Norval Pressure Regulators

1213B2 Service Regulators Maximum Inlet Pressure 125 PSIG

Type 99 Pressure Reducing Regulators

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Types ACE95 and ACE95Sr Tank Blanketing Valves

Models 106-RF / 206-RF Rate of Flow Control Valve

Types ACE95 and ACE95Sr Tank Blanketing Valves

Pressure regulators. Introduction. TR Head. 3 ways body Dival

Type 1190 Low-Pressure Gas Blanketing Regulator

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications

Regulator from 1800 B series

Slam Shut Valves SBC 782

Transcription:

RESIDENTIAL REGULATORS Type B NG Process Management TM

B NG Regulators Description! BODY RESISTANT TO HIGHER PRESSURES Various Springs Adaptable to various fluids (Natural Gas, LPG, Manufactured Gas, etc.)! ALL PARTS IN PERMANENT MOVEMENT - NO STICKING Factory Pre-set Fixed setting st 1 Stage Reduction Outlet pressure accurate even in the case of inlet pressure variations! VENT Internal Relief Safety feature in case of outlet overpressure Resetting knob! STRONGER FITTINGS New Shut off Valve Triple security - Excess flow - Low outlet pressure - Low inlet pressure (flow only) nd 2 Stage Reduction Outlet pressure accurate even in the case of Flow variations! LOW INTERMEDIATE PRESSURE Special Internal and External Protection for Underground Version Easy to use High Quality Pre-shaped Diaphragm High precision Type B NG Regulator - Main Characteristics 2 Concealed Screws Easy assembly and disassembly

B NG Regulators Description The new Type B NG residential regulator is a direct-action, spring-loaded regulator, with high performance and reinforced safety features. A shut off valve cuts off the flow in the case of excessive flow, or when the outlet pressure drops below the set point (high gas demand or broken line), or in the case of inlet pressure dropping below the set point (network pressure drops or pipe damage). The regulator can be manually reset after the safety function trips. The regulator is factory preset. The new B6 NG is interchangeable with the current angle-shaped B6 N (same key dimensions). MAIN SAFETY FEATURES PERFORMANCE FEATURES Downstream equipment protection Stronger fittings permitting easy and safe installation Body withstands higher pressures (12.5 bar for 1 st stage reduction and 5 bar for 2 nd stage reduction) giving exceptional resistance in the case of upstream overpressure All parts are in permanent movement, therefore no risk of sticking, to assure immediate response and protection of the downstream equipment 2 stages of reduction produce a constant outlet pressure, which is insensitive to changes in inlet pressure Nominal flow up to 10 m 3 /h(n) with an accuracy of AC 5 Inlet pressure range 0.5 to 5 bar, possibility of 0.1 to 6 bar under certain conditions Outlet pressures 21, 27, 37 mbar (standard), others (9 to 50 mbar) available upon request The B NG is equipped with an internal relief valve A filter protects the regulator on the inlet side 3

B NG Regulators Larger Application & Integration Range Two compact installations Flow up to 10 m 3 /h (AC 5) Higher inlet pressure acceptance New marking, easier to read in the case of cabinet installation Line-Shape Angle-Shape Features Technical Features Inlet Pressure Pu: Outlet Pressure Pd: 0.5 to 5 bar (0.1 to 6 bar on request) 9 to 50 mbar Connection Sizes Inlet: 3/4" sphero-conical or flat - Others on request Outlet: Flat joint with the following nuts: 1"1/4, 1"BS746, 1"ISO228, range for national meters, others on request 4

B NG Regulators Functional Features Temperature TS: -20 / +60 C (< -20 C under certain conditions) Flow Capacity Q: 0 to 10 m 3 /h(n) Accuracy AC: Up to 5 28 27 26 25 24 23 22 21 20 19 18 17 16 15 Pd (mbar) Pressure regulation zone Shutoff zone due to excess flow (According to customers requirements) 10 Flow (%) 100 120 150 Lock-up Pressure Class SG: Up to 20 Flow Curve indicating Shutoff Zone B6 NG Material Body Casing Inlet Connection : Zinc/Aluminum Alloy : Zinc/Aluminum Alloy : Brass Outlet pressure for a 21 mbar setting 23 22 21 20 19 18 0 1 2 3 4 5 6 7 8 9 10 m³/h(n) Natural Gas 0.3 to 5 bar 0.2 bar 0.1 bar Inlet Filter Outlet Connection : Bronze or Plastic : Brass B6 NG Flow Curves 1 st Stage Plug : Nitrile 1 st Stage Disc Orifice : Aluminum 2 nd Stage Plug : Nitrile 2 nd Stage Disc Orifice : Brass Diaphragms : Nitrile Vent Screen : Stainless Steel Vent : Plastic (option) Outlet pressure for a 21 mbar setting B10 NG 24 23 22 21 20 19 18 17 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 m³/h(n) Natural Gas 0.4 to 5 bar 0.3 bar 0.2 bar 0.1 bar B10 NG Flow Curves Flow Range at 21 mbar B NG Flow (m 3 /h(n)) B6 NG B10 NG Pu (bar) 0.1 0.2 0.3 0.4 0.5 to 6 0.1 0.2 0.3 0.4 0.5 to 6 m 3 /h(n) 3.5 6 6.6 6.6 6 10 11 11 5

Dimensions & Weight Dimensions (mm) Line-Shape Dimensions Angle-Shape Dimensions 94.9 119 64 176 103 162.9 101.3 Weight: 980 to 1000 grams depending on version Natural Gas Technologies Emerson Process Management Regulator Technologies, Inc. Francel SAS Business Park - 3 avenue Victor Hugo CS 80125 28008 Chartres Cedex, France Tel: +33 (0)2 37 33 47 00 Fax: +33 (0)2 37 31 46 56 O.M.T. Officina Meccanica Tartarini s.r.l. Via P. Fabbri, 1 I - 40013 Castel Maggiore (Bologna), Italy Tel.: +39-0514190611 Fax: +39-0514190715 E-mail: info.tartarini@emerson.com For further information visit www.emersonprocess.com/regulators The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the property of their prospective owners. Fisher is a mark owned by Fisher Controls, Inc., a business of Emerson Process Management. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. We reserve the right to modify or improve the designs or specifi cations of such products at any time without notice. Emerson Process Management does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and maintenance of any Emerson Process Management product remains solely with the purchaser. 04/2012 NCABNGEN Emerson Process Management Regulator Technologies, Inc., 2012; All Rights Reserved Process Management TM