Electrical Safety, Subpart K

Similar documents
Electrical Safety PPT-SM-ELECTSFTY V.A.0.0

2. What is the definition of an electrocution hazard? a. Electrocution results when a person is exposed to a lethal amount of electrical energy

Safe Schools: A Health and Safety Check

11/2/2017. Course Objectives. Overview

Ground Fault Circuit Interrupter(GFCI) Policy

ELECTRICAL (COMPREHENSIVE) SAFETY PROGRAM REGULATORY STANDARD: OSHA - 29 CFR CFR , ,

Electrical. Version 1.0

Ground Fault Protection for Electrical Tools

This training session covers electrical safety for unqualified persons. Unqualified persons are machine operators, operators of powered industrial

Electrical. OSHA Office of Training and Education 1

Definitions found in several locations:

APPENDIX A. Appendix A: Fall Hazards Lesson Test Instructor Copy (answers bold/italic), Student copy to distribute follows

Ground Fault Protection on Construction Sites

Electrical Safety. Unqualified Worker

OSHA 30 Syllabus. Laborers Training School. Time: 40 hours. Maximum Class Size: 30. Prerequisites: None

SOLAR CONSTRUCTION SAFETY REVIEW QUESTIONS

Section 8 Safety Model Stage 3 Controlling Hazards: Safe Work Practices

Electrical Safety Work Practices

Electrical Safety. Introduction

Construction Focus Four: Electrocution Hazards

ELECTRICAL SAFETY. Unsafe work practices near electricity can kill you! You are responsible for protecting yourself from electrical shock.

Original Date of Issue: 04/09

Weekly Safety Meetings

HIGH-IMPACT SAFETY TRAINING FOR QUALIFIED ELECTRICAL WORKERS

PERMANENT POOLS. Location

OSHA Federal Standards October 1, 2016 September 30, 2017

Management Plan for Electrical Safety ISD #535

POOL AND HOT TUB/SPA REGULATIONS A BUILDING PERMIT IS REQUIRED BEFORE THE INSTALLATION OF A POOL.

Electrical Safety Program February 2, 2016

Management Plan for Confined Spaces

2012 NFPA 70E: Electrical Safety In The Workplace

Portable Oil Lube Air Compressors

Bulletin Swimming pool, hot tub and spa installations Rules , , , , , and

Electric and Natural Gas Safety Trainer s Guide

SUBJECT: SAFE WORK PRACTICES CHECKLIST FOR LOW VOLTAGE ELECTRICIANS REVISION September 15, Area Checklist Items 2600SEG131 Check ( or NA)

SILENTAIRE TECHNOLOGY

Electrical Safety Program

Department of Electrical Engineering & Computer Science. Electrical Safety. for Staff and Students in EECS Instructional Laboratories

Project Name: Om Vihar- Affordable Group-Housing Project Promoter: Om Bhakt Real Estate LLP RISK ASSESSMENT

SHOP SAFETY INSPECTIONS

City of Crystal Lake Community Development Department

Welding With Arc Welding Equipment

OSHA Subpart I Tools - Hand & Power

Leader s Guide ERI Safety Videos

AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP General User and Maintenance Instructions

Section 2 Safety, Tools and Equipment, Shop Practices Unit 4 General Safety Practices. Unit Objectives. Pressure Vessels and Piping (1 of 2)

The purpose of this training is to give field technicians awareness training and guidelines on potential hazards they may encounter in the field.

TESTING SKILLS SAFETY

CITY AND COUNTY OF DENVER CR&CF RISK UNIT Electrical Safety Standard

Lockout/Tagout - Energy Control Program

Electrical Safety Program

PALM BEACH STATE COLLEGE PERSONAL PROTECTIVE EQUIPMENT (PPE) JOB HAZARD ASSESSMENT

UNIVERSITY OF TOLEDO

GENERAL ELECTRICAL SAFETY

Leader s Guide ERI Safety Videos

Risk Management Resources

Portable Electric Tools

SECTION 51 NFPA 70E POLICY. Health & Safety Policy and Procedures Manual

Heavy-Duty Hot Knife

City of DuBois PERMIT APPLICATION P. O. Box 408, 16 West Scribner Ave - DuBois, PA Phone: Fax:

This written Compressed Gas Plan is kept at the corporate office and in the written Safety & Health Program.

Electrical Safety Program

City of Lockport Above Ground Pool Regulations

1. What is the top priority when working on Canadian Pacific (CP) property? 2. When working on CP property what must all Contractors comply with?

CONSTRUCTION SAFETY PROGRAM FOR. Golder Acoustics Inc.

Elements of a Lockout/Tagout Program OSHA

Lockout / Tag out Program

List all key terms and acronyms used in the procedure, and their definitions.

Welcome to this training session about arc flash. In this session, we ll talk about the hazards and risks of working around exposed, energized

PC 1010 Electric Air Compressor

INSTRUCTIONS FOR MODEL SG6500 GAS HEATERS

Electrical Safety Management for Research Work Environments

Doc No: ELECTRIC Midland Engineering Co., Inc. Initial Issue Date 12/14/15 Safety Management System

CALL BEFORE YOU DIG POLICY AND PROCEDURE

PALM BEACH STATE COLLEGE PERSONAL PROTECTIVE EQUIPMENT (PPE) JOB HAZARD ASSESSMENT

Owner s Manual & Safety Instructions

ELECTRICAL SAFETY PROCEDURE

OSHAcademy Course 715 Study Guide. Electrical Safety Basics

EFCOG Best Practice # 206

Aerial Lift Safety Program

2008. AURORA PICTURES

2523-LDG-E. Leader s Guide

Electrical Safety Program

SILENTAIRE TECHNOLOGY

: Electric Power Generation, Transmission, and Distribution. Region IV - OSHA

Title: NFPA 70E Effective Date: 12/8/2014 Control Number: THG_0053 Revision Number: 1 Date: 10/26/2015 Annual Review Completed: 5/13/2015 NFPA 70E

SWIMMING POOL PERMITS ARE ABOUT HEALTH AND SAFETY

Pool Permit Application

What Every Town Manager Needs to Know About Workplace Safety

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

HOW TO PREPARE FOR THE LEVEL A CRANESAFE CERTIFICATION ASSESSMENT

Tower Climber Orientation.

Pannier Corporation Health and Safety Handbook Marking System Group Aerial Lifts Original Date: Section: Revision date: Page: 12/5/ of 11

Course 115. Electrical Safety for Employees: Basic

ERI Safety Videos Videos for Safety Meetings POWER SAW SAFETY. Leader s Guide 2001, SAFETY SOURCE PRODUCTIONS

MISSOURI UNIVERSITY OF SCIENCE & TECHNOLOGY Procedure: 3.6

CONTROL OF HAZARDOUS ENERGY (LOCKOUT/TAGOUT) PROGRAM

MAINTENANCE MECHANIC RCF

#11581 SAFELY ON YOUR FEET

ES18 Security Theory/Regulations Answer Schedule

Transcription:

SHARP Instructor Training Guide Training Overview: Electrical Safety, Subpart K This guide is designed to assist the instructor with the presentation of the Electrical Safety training materials. Each numbered statement represents a statement of fact or concept that should serve as a takeoff point for elaboration. Instructors should draw upon personal real-world experience for analogies and anecdotal embellishment. The trainees study guide is brief and they should be given a few minutes to read and review it. More information about each statement of fact or concept can be gleaned through its corresponding part or section of Subpart K. Some of those specific sections are referenced below. 1. Ground Fault Circuit Interrupters (GFCIs) must be in place to protect workers from shock on all construction work sites. They are fast acting circuit breaker devices that detect small imbalances in the circuit caused by current leakage to ground, and in as little as one-fortieth of a second, cuts off the power in the circuit. 29CFR1926.404(b)(1)(ii) Note: The alternative to GFCIs is an Assured Equipment Grounding Program. It is worth mentioning that almost all new construction sites that provide power to the contractor, provide power that is GFCI protected. Also, portable generators rated 5kW or less are exempt from GFCI requirements if properly wired. 2. GFCIs do not take the place of grounding. Hand tools and extension cords must always have a grounding lug on their male plugs. Only double-insulated tools that are clearly marked as such do not have to have grounding lugs. 29CFR1926.404(f)(7)(iv)(C)(6) 3. Electricity is always seeking a path to ground. If you touch conductors that are not insulated, you become part of the circuit and the electricity may go through you to get to ground. Note: It must be emphasized that the very best conductor of electricity is water, and that wet or even damp conditions make the possibility of shock greater. Large amounts of current have been known to arc several feet or more through damp air to a ground source. 4. The longer you are part of an electrical circuit, the more damage is done to your body. The closer the point of entry or exit of electrical current to your heart or brain, the more damage will be done. The overall amount of damage to the body from electrical shock depends on the amount of current, the duration of the shock, and the points of entry and exit of current into and from the body. Note: The total amount of physical damage that can be wrought by electrical shock is dependent on how great the amount of current, how long the shocking connection is, and where the current enters and leaves the body. Many shocks can do both internal damage to the heart and organs and also leave extreme burns that run deep into the tissues. 5. Power tools and extension cords must always be inspected prior to their use. Tools or cords found to be defective must be taken out of service and brought in for repair immediately. 29CFR1926.404(b)(1)(iii)(C) Note: Unless immediately removed from the jobsite, tools or cords found to be defective should be rendered totally un-useable by cutting off the male plug. Defective tools and cords that are only placed back in the toolbox will not get serviced as quickly as they might if they are kept on the seat of the truck where the foreman or his designee can remit the defective item to the proper company service entity. 6. Most states and municipalities have statutes that require that crane booms and other aerial equipment maintain a minimum of 10 feet from overhead lines. Note: When using ladders around electrical lines, try to have wooden or fiberglas ladders available. If aluminum ladders are all that are available, use extra caution in placing and securing the ladder.

7. A popular myth on construction sites is that extension cords have to have molded ends to comply with OSHA standards. NOT TRUE. Any end that has a form of strain relief and is Underwriter s Laboratories (UL) approved is acceptable. Note: Extension cords on construction sites have to be three conductor type and designed for hard or extra-hard usage. That would include from Table 400-4 of the ANSI/NFPA, Article 400, types S, ST, SO, and STO. These types would be 12/3 gauge, minimum. 8. Cords that have the outer jacket cut or scraped can be taped and used. The defect that renders a cord unserviceable is when any of the conductors insulation is cut or broken. 29CFR1926.405(g)(2)(iii) Note: No. 12 or larger cords can be repaired or spliced but only if done so in a way that the conductors retain their insulation. It requires an intricate repair method that is probably out of the technical realm of any but trained electricians. 9. Tool cords or extension cords that are hot or warm to the touch indicate that too much current for the size of the cord is being used by the tool or tools. Note: Cords that are warm may also be a sign of a tool that is malfunctioning. Sometimes, warm or hot cords can be remedied by taking some tools off the circuit to decrease the load. 10. Remember that electrical short circuits can not only shock and burn people, but can start fires. Note: Electrical fires are Class C fires. They can be fought with a common A-B-C fire extinguisher, but an effort should be made first to cut off the source of power that caused the fire in the first place. If the source is not shut off, the fire can re-ignite easily. Answers to Quiz: 1. B 2. C 3. C 4. D 5. A 6. C 7. C 8. B 9. B 10. B

SHARP Safety Training Guide Training Overview: Electrical Safety, Subpart K This guide is designed to assist in the promotion and training of Electrical safety. Each numbered statement represents a statement of fact or concept that should serve to provide you with information you can use to protect yourself against electrical shock or burns. 1. Ground Fault Circuit Interrupters (GFCIs) must be in place to protect workers from shock on all construction work sites. They are fast acting circuit breaker devices that detect small imbalances in the circuit caused by current leakage to ground, and in as little as one-fortieth of a second, cuts off the power in the circuit. 2. GFCI s do not take the place of grounding. Hand tools and extension cords must always have a grounding lug on their male plugs. Only double-insulated tools that are clearly marked as such do not have to have grounding lugs. 3. Electricity is always seeking a path to ground. If you touch conductors that are not insulated, you become part of the circuit and the electricity may go through you to get to ground. 4. The longer you are part of an electrical circuit; the more damage is done to your body. The closer the point of entry or exit of electrical current to your heart or brain, the more damage will be done. The overall amount of damage to the body from electrical shock depends on the amount of current, the duration of the shock and the points of entry and exit of current into and from the body. 5. Power tools and extension cords must always be inspected prior to their use. Tools or cords found to be defective must be taken out of service and brought in for repair immediately. 6. Most states and municipalities have statutes that require that crane booms and other aerial equipment maintain a minimum of 10 feet from overhead lines. 7. A popular myth on construction sites is that extension cords have to have molded ends to comply with OSHA standards. NOT TRUE. Any end that has a form of strain relief and is Underwriter s Laboratories (UL) approved is acceptable. 8. Cords that have the outer jacket cut or scraped can be taped and used. The defect that renders a cord unserviceable is when any of the conductors insulation is cut or broken. 9. Tool cords or extension cords that are hot or warm to the touch indicate that too much current for the size of the cord is being used by the tool or tools. 10. Remember that electrical short circuits can not only shock and burn people, but can start fires.

SHARP Electrical Safety Quiz Name: Date: (Circle the letter that best answers the question) 1. GFCI stands for: A. Ground For Construction Industry B. Ground Fault Circuit Interrupter C. Ground Fault Cancel Initiative. D. None of the above 2. What type of tools are not required to have a ground lug on their male plug? A. Power Tools B. Industrial Duty Tools C. Double-Insulated Tools D. Do-It-Yourselfer grade tools 3. Electricity always seeks: A. A path to humans B. A path to insulators C. A path to ground D. A path to motors 4. The severity of an electrical shock depends on: A. The amount of current B. The duration of the shock C. The path of current through the body D. All the above 5. Power tools and extension cords should never be used if: A. They are inspected and found to be defective B. They have been carried by their cord C. Been left out in the rain D. All the above 6. How far, at a minimum, should ladders and cranes be set up from overhead lines? A. 30 Feet B. 20 Feet C. 10 Feet D. 5 Feet 7. The feature of a tool or extension cord that keeps the cord from twisting off inside is called: A. The safety valve B. The safety connector C. The strain-relief boot D. A and C 8. Cords can be repaired if: A. The person doing the repair is a competent person. B. The insulation on the conductors is intact C. The plugs are both in good shape D. Defective cords cannot be repaired. 9. If the cord gets warm or hot on the tool you are using, it means the tool is being overused. A. True B. False 10. One thing you would not expect as a result of an electrical shock would be: A. Internal trauma B. Massive bleeding C. Severe Burn Trauma D. The ignition of a fire

SHARP Discussion Leader: Attendance Sheet Electrical Safety Training Location: Date: Discussion Topics / Handouts Reviewed: Electrical SafetyTraining Guide -Printed Name- -Signed Name- 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15.