Pressure switch with bourdon tube

Similar documents
Bourdon tube pressure gauge for diaphragm seals

Pressure transmitter PASCAL Ci4

Bourdon tube pressure gauge, stainless steel For extremely low ambient temperatures down to -70 C Model PG23LT, with case filling

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

SITRANS P measuring instruments for pressure

Expansion Thermometers Stainless Steel Series, Model 70

BDT20 Safety process pressure gauge 100 & 160mm

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

Differential pressure gauge For the process industry Model , all-metal media chamber

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

Bourdon tube pressure gauges with glycerine filling, for chemical applications EN 837-1

Pressure Switches Application Guideline

Product Catalogue. P-SERIES Pressure Gauges

Mounting and Operating Instructions EB 9520 EN. Differential Pressure and Flow Meter Media 05

Pressure Measurement Single-range transmitters for general applications

Instruction Manual Contact Pressure Vacuum Gauge

ED 701 Hygenic Pressure Transmitter

Mechanical Pressure Measurement

Diaphragm monitoring system with threaded connection For the chemical and petrochemical industries Model DMS34

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Gas density monitor With integrated transmitter Model GDM-100-TI

Premium Series: Pressure, Differential Pressure and Level Transmitters. PASCAL Ci4. Chemical industry Mechanical engineering Process industry

Pressure Measurement Single-range transmitters for general applications

OPTIBAR P 1010 C Technical Datasheet

Technical Data. Dimensions

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

Bourdon tube pressure gauges for chemical applications EN 837-1

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm

Technical Data. Dimensions

Siemens AG psi (6 bar) 145 psi (10 bar) 464 psi (32 bar) 1450 psi (100 bar) 3626 psi (250 bar) 8700 psi (600 bar) psi (800 bar)

Technical Data. Dimensions

Technical Data. General specifications. Rated operating distance s n 5 mm

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

GA24 Technical Datasheet

x act i Precision- Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor

ATM/Ex - Analog Pressure Transmitter

Mounting and Operating Instructions EB 9520 EN. Differential Pressure and Flow Meter Media 05

Pressure gauges EN All stainless steel construction PBX100, PBX150 (1.18) Functional and constructive characteristics

DK46 - DK800 Supplementary instructions

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide

Technical Datasheet. D Series SMART Pressure Transmitter Model: DPC D-Series. Key Features. Series Overview. Product applications

SITRANS. Pressure transmitter SITRANS P, Z series for gauge and absolute pressure. Introduction. Safety instructions 2.

ATM.1ST/Ex - High Precision Transmitter

Technical Data. General specifications. Rated operating distance s n 2 mm

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

Mounting and Operating Instructions EB 9519 EN. Differential Pressure and Flow Meter Media 5. Zero adjuster

Pressure gauges EN Safety pressure gauges solid-front PBXSF100, PBXSF150 (1.20) Functional and constructive characteristics

ATM.ECO/IS - Analog Transmitter with Temperature compensation

Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800

High-performance submersible pressure transmitter For level measurement Model LH-20

Technical Data. Dimensions

Technical Data. Dimensions

ATM/Ex - Intrinsically Safe Analog Pressure Transmitter - ATEX / IECEx Certified

Technical Data. General specifications Switching element function Rated operating distance s n 1.5 mm

High-performance submersible pressure transmitter For level measurement Model LH-20

Technical Data. Dimensions

Differential pressure

Type 4708 Supply Pressure Regulator

Instruction Manual Contact Pressure Gauge

Hydrostatic. Continuous level measurement. Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 AL-EN

Notes on equipment protection per EN/IEC and NEMA For Bourdon tube or diaphragm pressure gauges

PKP Prozessmesstechnik GmbH. Borsigstrasse 24. D Wiesbaden-Nordenstadt. Tel: / Fax: / Operating Instructions

Notes on equipment protection to DIN EN and NEMA

MEASURING INSTRUMENTS - STRUMENTI PER MISURARE

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Technical Data. Dimensions

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 10 mm

High-performance submersible pressure transmitter For level measurement Model LH-20

PRESSURE & TEMPERATURE GAUGES PRESSURE TEMPERATURE. Catalogue H20200a

Gas Pressure Regulator HON 502

Supplementary Installation and Operating Instructions. Variable Area Flow Meters SGK-1 Ex SGK-2 Ex SGK-3 Ex. Category: II 2G Ex IIC II 3G Ex IIC

Instruction Manual Differential Pressure Transmitter

sitrans p Operating Instructions (de/en) Edition 03/2004

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

C-Flow Coriolis Mass Flow Meters

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

4/2 way Pneumatic Solenoid Valve

New! SOLFRUNT 659 Stainless Steel Pressure Gauges. Process Gauges A18

Installation and Maintenance Instruction Manual

Aluminium, white with black lettering. Bar. Option with unit bar/pa, bar/psi, kpa, MPa, psi

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

ATM - Analog Pressure Transmitter

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

TYPE APPROVAL CERTIFICATE

Compact pressure switches for gas and air

Hydraulic Accumulators with Back-Up Nitrogen Bottles

Inductive slot sensor

Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L

9700 Transmitter Submersible hydrostatic level transmitter

Technical Data. Dimensions

SOLFRUNT Model /2" (63mm) and 4" (100mm) Stainless Steel Gauges

Transcription:

Pressure switch with bourdon tube for plants requiring special supervision,type series BN4 Features Pressure switch with bourdon tube for plants requiring special supervision, Nominal ranges -1...0 bar to -1...24 bar, 0...1 to 0...400 bar High quality case with bajonet ring NS 100/160 per EN 837-1 S1, alternative safety design per EN 837-1 S3 Ex-proof design Case and measuring element of stainless steel Accuracy class as per DIN 16085 Inductive contact EAC declaration (upon request) Options Application area General process technology Chemical and petrochemical industry Machinery construction Shipping Approvals/Certificates - Classification per SIL2 - Certificate of measuring equipment for Russian Federation - Material certificate per EN 10204 - Calibration certificate per EN 10204 Case with liquid filling Oxygen free of oil and grease Connection to Zone 0 Application Pressure switches with bourdon tubes are pieces of equipment with safety functions as set down in the Pressure Equipment Directive (PED). They are suitable for protecting the pressure device should the pressure rise above, or drop below, the approved boundary limits. They come under the remit of PED 1G Category IV and have been subjected to an EC type-examination. The requirements of Approval Certificate Pressure 100 from the German Technical Inspection Authority (VdTÜV) are met. These pressure measuring devices may only be operated with the electrical evaluation units set out below, and within the area of application of this certificate and the VdTÜV component identification number. The pressure switch is composed of the pressure measuring device and electrical evaluation unit. Because of its robust design, it is suitable for use in tough environments. Technical data Constructional design / case Design: High quality case with bayonet ring per EN 837-1 S1, material: stainless steel mat.-no.-nr. 1.4301 (304) ; with blow-out device, material: PUR, ventilation valve, material: PUR Alternative: Safety design with blow-out back and solid baffle wall per DIN EN 837-1 S3, Material: Stainless steel 1.4301 (304), pressure compensation diaphragm: silicone Nominal size: NS 100 or NS 160

Degree of protection per EN 60529: Case filling: Atmosph. pressure compensation: Without filling: IP 65 With filling S1 case: IP 65 With filling S3 case: IP 66 Labofin Standard case, filled, 10 bar: with ventilation valve < 10 bar filling plug, material: PUR Safety case, filled: with pressure compensation diaphragm, material: silicone Material wetted parts Measuring element: Nominal range Bourdon tube and pressure connection material stainless steel mat.-no. 1.4571 (316Ti) See order details, other ranges upon request Overload protection Standard: 1.3 times Case seal: Material gasket: NBR Accuracy Window: Contact lock: Measuring element: Movement: Scale: Non splintering laminated glass Stainless steel with NBR gasket, sealable Bourdon tube < 60 bar: c-type 60 bar: spiral Stainless steel segment Pure aluminium, white with black inscription Accuracy class: NS 100 Nominalrange (bar) no. of contacts 1 2 1 cl. 1 cl. 1.6 1,6 cl. 1 cl. 1 NS 160 Nominalrange (bar) no. of contacts 1 2 Pointer: Pure aluminium, black, with micro adjustment for zero point correction 1 cl. 1 cl. 1.6 1,6 cl. 1 cl. 1.6 Mounting: Electronical connection: Via process connection. Optional with flange for surface mounting or for flush mounting with DIN mounting flange. Connection plug with cable gland M20 x 1.5 and removable test cover, material: Macrolon Temperature influence: 2,5 cl. 1 cl. 1 Plus effect of switch function on indication per DIN 16085. Max. ± 0,4% / 10K of measuring span per EN 837-1 Electrical evaluation unit: The following evaluation units conform to the requirements of the Association of Technical Inspection Agencies (VdTÜV) Fact Sheet No. 100. Pepperl+Fuchs, switching amplifier: Typ KHA6-SH-Ex1, PTB 00 ATEX 2043 Typ KFD2-SH-Ex1, PTB 00 ATEX 2042 The use of alternative evaluation units is within the responsibility of the operator. The data sheets of the electrical evaluation units are to be observed. Temperature ranges without filling with filling Ambient: -20 70 C -20 70 C (40 C) 1 Media: -20 70 C -20 70 C (40 C) 1 Storage: -40 70 C -20 70 C 1 For safety case S3 design and classification per SIL2 For measuring devices with inductive contact type SJ2-S1N (NS 100, double contact) - if not one of the above mentioned switching amplifiers from Pepperl+Fuchs is used: For safe operation refer to TA_044! Weight: NS 100 without filling: approx. 0.9 kg NS 160 without filling: NS 100 with filling: NS 160 with filling: approx. 1.8 kg approx. 1.5 kg approx. 3.6 kg Process connection Design: Per EN 837-1. G1/2 B, 1/2" NPT or M20 x 1.5, bottom or back eccentric connection. Optional with throttle screw for system damping, further process connections upon request

Approvals/Certificates Ex-protection: Inductive contact device: Contact device suitable for intrinsically safe circuits. II 2G Ex ia IIC T4/T5/T6 Gb Reg.-no.: PTB 00 ATEX 2049X Ex-protection (ATEX) for mechanical devices: II 2G c Tx II 2D c Tx Further details see operating instruction BA_037 and Ex Safety Instructions XA_005 and XA_014. SIL 2: Functional safety: per EN 61508, classification per SIL 2, TÜV-Reg.-Nr. 44 799 13190203. Switch functions Inductive contact: (SN) Type N4 Safety initiator max. 2 contacts, contactless Control unit required, see product group M7 Further information see operating instruction BTA_037. Induktive contact inverse: (S1N) Type N5 Safety initiator, inverse switching max. 2 contacts, contactless Control unit required, see product group M7 Further information see operating instruction BA_037 and Technical Information TA_039. EC-Type Examination: EC-Type Examination per Directive 97/23/EG, certificate no. 07 202 1321 Z 0001/14/D/01, piece of equipment with safety function cat. IV VdTÜV-component identification number: - TÜV.SDW.14-234 - TÜV.SDWF.14-234 - TÜV.SDWFS.14-234 EAC declaration (upon request) Certificate of measuring equipment for Russian Federation Dimensions dimension standard design (mm) case d1 h1 a c e f h d2 d3 d4 a1 NS 100 100 111 19 37 30 89 83 116 132 4.8 30 NS 160 160 112 19 37 60 119 113 178 196 5.8 30 dimensions safety case (mm) case d1 h1 a c e f h d2 d3 d4 a1 NS 100 100 123 37 - - 89 83 116 132 4.8 - NS 160 160 133 37 - - 119 113 178 196 5.8 - Contact settings: The contacts can be adjusted over the entire indicating range. The black scale section may only be used for pressure-limiting applications. Adjustment is carried out by pressing in, and rotating the internal adjusting finger, using the accompanying adjusting key at the adjustment lock. Signal evaluation: The fitted inductive proximity switches are suitable for connection to switch units with normalized input, according to DIN 19234.

Order details Pressure switch with bourdon tube for plants requiring special supervision Type series BN4... Order details BN4 BN4200 BN4210 BN4220 BN4230 BN4300 BN4310 BN4320 BN4330 standard case IP 65 NS 100 NS 160 without liquid filling with liquid filling without liquid filling with liquid filling BN4250 safety case IP 65, NS 100 without liquid filling BN4600 per EN 873-1 S3 NS 160 without liquid filling BN4540 safety case IP 66, NS 100 with liquid filling BN4640 per EN 873-1 S3 NS 160 with liquid filling A2 B2 process connection G1/2 B 1/2" NPT C2 M20 x 1,5 086-1...0 1 087-1...0.6 1 088-1...1.5 089-1...3 090-1...5 091-1...9 092-1...15 093-1...24 053 0...1 054 0...1.6 055 0...2.5 nominal range [bar] 056 0...4 057 0...6 058 0...10 059 0...16 060 0...25 061 0...40 062 0...60 063 0...100 064 0...160 065 0...250 066 0...400 N4. 00 N4.. 0 N5. 00 N5.. 0 switch contact type of contact number single contact safety-initiator (SN) double contact inductive contact single contact safety-initiator-inverse (S1N) 2 double contact... switch function - per contact, replace point with number 2 increasing preassure breaks contact switch 5 decreasing preassure breaks contact LABOM Mess- und Regeltechnik GmbH Im Gewerbepark 13 27798 Hude Germany Phone: +49 (0) 4408 804-0 Fax: +49 (0) 4408 804-100 e-mail: info@labom.com www.labom.com

Additional features (to be indecated if required) V2 rear flange fur surface mounting 3 mounting V3 front flange for flush mounting W2603 functional safety per EN 61508, classification per SIL2 W2673 certificate of measuring equipment for Russian Federation W4001 free of oil and grease for oxygen application Z1 connection to zone 0 with zone 0 adapter (coupler element KF6) Order code (example): BN4200 A2056 N4200 -.. 1 not with case filling 2 with NS 100, double contact: for safety operation refer to TA_044! 3 standard case, only LABOM Mess- und Regeltechnik GmbH Im Gewerbepark 13 27798 Hude Germany Phone: +49 (0) 4408 804-0 Fax: +49 (0) 4408 804-100 e-mail: info@labom.com www.labom.com