Portable Hydrostatic Pneumatic Test Pump. Procedure Manual

Similar documents
Portable Hydrostatic Electric Test Pump. Procedure Manual. Dixon 800 High Street Chestertown, MD Fax: dixonvalve.

Operating Instructions Models and Hydrostatic Test Pumps

HPIC D Hydrostatic Test Pump PRODUCT INFORMATION AND OPERATING INSTRUCTIONS

Operating Instructions Models and Hydrostatic Test Pumps

Operating Instructions Models and Hydrostatic Test Pumps

Operating Instructions Models 36200, , 46200, Hydrostatic Test Pumps

Operating Instructions Models and Hydrostatic Test Pumps

PARTS: AIRPREP AFTERCOOLERS AND AIR DRYERS

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

Operating Instructions Model and Hydrostatic Test Pump

INTRODUCTION... 3 II II II II II II II II II II II II II I 4-5 ASSEMBLY... 6,7,8 II II II II II II II... 9

Model Air Caddy Orig TABLE OF CONTENTS

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

Instruction Manual Updated 7/26/2011 Ver. 2.2

HPB25 Hydraulic Paving Breaker

INSTRUCTION MANUAL & PARTS

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

Binks SG-2 Plus TM Rotary 2 QT. PRESSURE CUP

Speed control assembly model A-1

accidents which arise due to non-observance of these instructions and the safety information herein.

VOLUMATIC WATER REGULATOR

UltRo Dual Flow Reverse Osmosis Water System

Pressure Dump Valve Service Kit for Series 2300 Units

MANUAL BE SERIES Test Benches

Pressure Dump Valve Service Kit for Series 3000 Units

Operating Instructions Model and Hydrostatic Test Pump

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL

INSERT FITTINGS INSERT FITTINGS

Jacuzzi. J-CQ420 Cartridge Filter Installation and Operating Instructions

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

LV LOADER DIRECTIONAL CONTROL VALVES INSTALLATION & USER GUIDE

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50 Systems Outfitted with ABM-725 Monitor C O M P A N Y

GETZ EQUIPMENT INNOVATORS RECOVERY SYSTEM CLEAN AGENT FE-36 / HALOTRON 1 PART NO. 4G59751 OPERATIONS MANUAL

Summary of Accumulators These operating instructions apply to the accumulators listed in the table shown below.

Installation and commissioning instructions 255 series and 256 series

MEGR-1627 Instruction Manual

STREAMLINE SHOP SERIES MODEL OPERATION & PARTS MANUAL

Freedom8 ShoeBox Compressor Manual

INSTRUCTION MANUAL MST AFTERCOOLER SYSTEM MODEL

8-GALLON AIR-OPERATED OIL CHANGER

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

CM MBC & CM MBC PARTS LIST

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

INSTRUCTION MANUAL FOR UNDERWATER OPERATION

Type ACE97. Introduction. Installation. P.E.D. Categories. Specifications. Overpressure Protection. Installation Guide English May 2002

Air Operated Hydraulic Pumping Systems to 50,000 psi

Operating Procedure TITON SUBSEA BOLT TENSIONER

Interface Devices, Inc. Hydraulic Mini Mule

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

PRESSURE TEST PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model No: PTP100. Part No: GC01/09

FI-25V OWNER S MANUAL

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

2.0 INSTALLATION & SERVICE

INTENDED USE TECHNICAL SPECIFICATIONS

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

Product Information News

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

35 TON HYDRAULIC PUNCH WARNING

VERTICAL BLADDER TANK

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Copyright MAY, 2008 By Grizzly Industrial, Inc. Warning: No portion of this manual may be reproduced in any shape or form without the written

SERVICE MANUAL MODEL BA100BMST 100 SCFM PORTABLE AIR PANEL

PRODUCT OPERATING MANUAL

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

MUELLER GAS. No-Blo Operations Using D-5. Drilling Machine. Reliable Connections. General Information 2

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

LARGE DRY CHEMICAL, TWIN-AGENT, AFFF, HALON 1211, AND AQUASONIC (NITROGEN-OPERATED SYSTEMS) Pressure Regulator Test Manual

ULTRA HIGH PRESSURE PAINT GRATE CLEANER FCT-JS OPERATION AND MAINTENANCE MANUAL

APPS-160 Gen 2 User Manual

Installation, Operation and Maintenance Manual for Back Pressure Regulator

TWO POST RAM PACKAGE 5 GALLON READ THIS MANUAL CAREFULLY BEFORE INSTALLING, OPERATING OR SERVICING THIS EQUIPMENT.

Advanced Fluid Handling Cart Owner s Manual

Installation, Operation & Maintenance Manual for Flo-Max Coupler Bracket Model FM150

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

CARTRIDGE FILTERS. Models: CF50, CF75, CF100, CF150,

2.5 & 5.0 GALLON PRESSURE TANKS

OPERATION MANUAL NTF-15

EKASAND 93 x 178 mm (3 2 /3 x 7 in.) Orbital Sander

Tech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800) MODEL D INFLATABLE JACKS

OPERATION MANUAL NTF-60 Plus

GREIG FILTERS, INC. OPERATION MANUAL

TECHNICAL DATA. Page 1 of 12

Hose Reel Enclosure Retrofit Kit

ROUGHNECK II Pumpless Drain

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

Operation Manual Piston Sensed Gas Pressure Regulators

OPERATING AND MAINTENANCE MANUAL

ALF400 to 900, ALT-5/-9

SERVICE MANUAL MODEL BA020AMST BREATHING AIR PANEL

RegO Adapters, Connector, & Fittings

Air Mask Low/High Pressure

Model PSI Compressor with 3-Gallon Air Tank 12VDC

1 DRIVE INDUSTRIAL IMPACT WRENCH

Build Your Own Flamethrower Step-by-step Manual

Carbon Fiber Tank with EZ Fill system Fill pressure 4,500 psi (310 bar) Output: up to 4,500 psi (310 bar)

Standard Specifications

High Pressure Equipment Taper Seal Valves, Fittings and Tubing

Transcription:

Portable Hydrostatic Pneumatic Test Pump Procedure Manual Dixon Valve & Coupling Company 800 High Street Chestertown, MD 21620 800-355-1991 Fax: 800-283-4966

Specifications Dixon Portable Pneumatic Hydrostatic Test Pump (PTP) Haskel model 4B-14-D3 Air over hydraulic pump pump made of aluminum with hard coated aluminum plunger 1500 PSI output pressure at 100 PSI inlet air pressure 5.5 GPM fill rate (at 60 PSI inlet water pressure) Air Chief ¼" Industrial Series plug quick connect air connection quick connect garden hose coupler for water supply line ½" x 15' intermediate hose with brass Straight-Thru quick couplers both ends ½" brass Straight-Thru plug on pressure outlet 0 2000 PSI center mount liquid filled pressure gauge Test caps, test plugs and pressure relief valves are available; consult your current Dixon Price List (DPL) for part numbers and pricing. Recommendations Use a Coalescing Filter. Oil or air tool lubricant will damage the seals of the pump very quickly. The coalescing filter, installed in front of the supplied modular air filter / regulator, will prevent oils from entering the air dome of the pump. Coalescing filters are available from Dixon Valve & Coupling Company. Consult your current Dixon Price List (DPL) for part numbers and pricing. Use a 5 to 10 micron Water Filter. Particulate matter, present in all water supplies, will damage the check valves and hydraulic seals very quickly. These filters (cartridge type) can be purchased from W.W. Grainger or from other plumbing supply centers. 2 Dixon Valve & Coupling 800.355.1991 Pneumatic Test Pump

Safety Precautions When used indoors, the pressure relief valve on the pump must be connected to a drain or water collection tank. This pump is designed to test of rubber hose. Dixon does not recommend the use of this pump for any other application. Adequate steps should be taken to protect property and personnel in the event of a failure during a test. These steps should include, but are not limited to the following: 1. Only trained personnel should conduct hydrostatic testing. 2. Use of safety glasses or shields for personnel conducting test and witnessing test. 3. All personnel should be perpendicular to the test sample and at least 15 feet away. 4. Place test sample in a protective enclosure. 5. Restrain both ends of the test sample to prevent hose from whipping in case of a failure. 6. If testing is done outside of a protective enclosure, restrict the movement of the couplings by the use of sandbags or other means. 7. Use only water as a test fluid. All incidental connections, intermediate hose and piping should be rated at 2000 PSI minimum. Before removing or adjusting any part of the pumping system or test sample, the following precautions should be exercised: 1. Shut off pump air supply. 2. Shut off pump water supply. 3. Release pressure inside the test sample. Pneumatic Test Pump Dixon Valve & Coupling 800.355.1991 3

Procedure for Hydrostatic Testing using Pneumatic Test Pump (PTP) It is important to know the parameters of the test being conducted. Follow the hose manufacturer, recommendations of Rubber Manufacturers Association (R.M.A.), OSHA, or other regulatory bodies guidelines for specific test parameters. The test should be carefully monitored and all results recorded. Dixon recommends the following sequence for a successful test: 1. Determine the test pressure of the assembly to be tested. 2. Make sure that the test caps or test plugs and all connections are tight on the test sample. 3. Connect the air supply line, the water supply line and the intermediate hose to the test pump. 4. Connect one end of the test sample to the intermediate hose. The connection between test sample and intermediate hose should be tight. 5. Connect the bleed-off valve to the other end of the test sample. 6. Open the bleed-off valve on the test sample. 7. Close the pressure relief valve (see 1 on drawing) on the pump. 8. Open the water inlet valve (see 2 on drawing) on the pump. 9. Fill test sample with water. Vent all air from test sample by keeping the bleedoff valve elevated until a solid stream of water (no bubbles) is coming out of the bleed-off valve. Warning! Do not turn off water supply once test sample has been filled with water 10. Turn air regulator knob (see 3 on drawing) counterclockwise to fully closed position. 11. Turn on the air supply valve (see 4 on drawing). 12. Turn the air regulator knob (see 3 on drawing) clockwise until desired test pressure is shown on the liquid filled pressure gauge (see 5 on drawing). 13. Hold test pressure until test duration requirement is met. 4 Dixon Valve & Coupling 800.355.1991 Pneumatic Test Pump

Procedure for Hydrostatic Testing using Pneumatic Test Pump (PTP) (continued) 14. Turn off air supply valve (see 4 on drawing). 15. Turn the air regulator knob (see 3 on drawing) counterclockwise until it is in the fully closed (off) position. 16. Close water inlet valve (see 2 on drawing). 17. Open pressure relief valve (see 1 on drawing) slowly to release pressure inside test sample. 18. Disconnect test sample from intermediate hose. 19. Drain water from test sample. Caution! When relieving the pressure and draining the test sample, many gallons of water may be released on the floor or ground. Use all precautions necessary to ensure that no one slips or falls as a result of this water being on the floor or ground. Pneumatic Test Pump Dixon Valve & Coupling 800.355.1991 5

6 Dixon Valve & Coupling 800.355.1991 Pneumatic Test Pump

Hydrostatic Test Report Engineer Report No. SUBJECT: PRESSURE PSIG TIME MIN "A" END COMMENTS "B" END REMARKS: TEST CONDUCTED BY: DATE: TEST APPROVED BY: VICE PRESIDENT ENGINEERING Pneumatic Test Pump Dixon Valve & Coupling 800.355.1991 7

Holedall Type Permanently Attached Coupling Test Engineer Report No. SUBJECT: HOSE: Working Pressure: Test Pressure: Burst Pressure: A END B END Hose OD (free) Hose OD (over stem) Stem Ferrule Die Mulcoram Pusher Force (PSI) Reduce Length Hose Wall (free) Hose OD Reduced Stem - Mean OD Hose Wall Reduced Reduction REMARKS: COUPLED BY: DATE: APPROVED BY: VICE PRESIDENT ENGINEERING 8 Dixon Valve & Coupling 800.355.1991 Pneumatic Test Pump

Industrial Band Type / Clamp Type Coupling Test Engineer Report No. SUBJECT: HOSE: Working Pressure: Test Pressure: Burst Pressure: A END B END Hose OD (free) Hose OD (over stem) STEM Shank Diameter Serrations Diameter Over Collar Diameter of Groove Insertion Lubricant CLAMP Bolts Torques REMARKS: COUPLED BY: DATE: APPROVED BY: VICE PRESIDENT ENGINEERING Pneumatic Test Pump Dixon Valve & Coupling 800.355.1991 9

Parts List Item Part # Description Material Qty 1 BCN50 ½" hex nipple brass 2 2 B-8-4FPCR ½" cross brass 1 3 STMP4B ½" Air Chief straight plug brass 1 4 SE4F4M ½" street ell brass 1 5 IBV50 ½" ball valve carbon steel 1 6 BCN75 ¾" hex nipple brass 1 7 BBV75 ¾" ball valve brass 1 10 HB2F4M ¼" x ½" hex bushing brass 1 11 GLSC445 0-2000 PSI ¼" center mount L.F. gauge 1 12 CB6-04M filter regulator 1 12 GC230 gauge 1 13 GPA-95-098 valve 1 14 DCP2103 ¼" x 3/8" Air Chief plug brass 1 15 HB3F4M 3/8" x ½" hex bushing brass 1 16 SE9050SS ½" street ell brass 1 17 4B-14 Haskel pump 1 17 ES50-MC muffler 1 18 GPA-95-037 modular pipe insert adapter 1 19 GPA-95-292 modular sleeve 2 20 MTB mounting boards 1 21 55HAC24 blue carriage rack 1 22 STFC4 female coupler brass 2 23 GH6638 Gates Matchmate Plus hose 1 26 FW25 ¼" flat washers 16 26 LW25 ¼" lock washers 8 26 MB2550 ¼" - 20 x ½" bolts 4 26 MB4150 ¼" - 20 x 1½" square head male 4 26 MN4 ¼" machine nut 8 27 LOGO Dixon sticker 1 28 166-0830 ½" X 3" long pipe nipple brass 1 29 SE6F6M ¾" street ell brass 1 30 BMA976 FGHT x ¾" MPT brass 1 31 500QCF garden hose female quick coupler brass 1 31 500QCM garden hose male quick coupler plug brass 1 32 TTA50 ½" X 260" thread tape 1 33 PTPMANU PTP pump manual 1 10 Dixon Valve & Coupling 800.355.1991 Pneumatic Test Pump