Annual Report on Liquefied Petroleum Gas (LPG) Related Accidents

Similar documents
Annual Report on Liquefied Petroleum Gas (LPG) Related Accidents

Annual Report on High Pressure Gas Related Accidents (2016 version)

GM Series Dual-Block Multi-Function Gas Control Valves

HOT SHOT OPERATING INSTRUCTIONS AND OWNER S MANUAL. Model SPC-500. (Propane Torch)

ISO INTERNATIONAL STANDARD. Small craft Liquefied petroleum gas (LPG) systems

Liquefied Petroleum Gas Market Regulations S.L

Using propane cylinders safely

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

Cylinder Exchange Training Manual

Owner's Manual and Instructions

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Truck Module Page 1 of 5 Utilities Gas Emergencies Revised

CRAFTSMAN EXAMINATION, NOVEMBER 2007 GASFITTING ANSWER SCHEDULE

INSTALLATION GUIDE Gas Rangetops

AIR BRAKE SYSTEM TROUBLESHOOTING

G AS BBQ GRILLS INSTALLATION INSTRUCTIONS

LP HOSE REGULATOR ASSEMBLY INSTRUCTION MANUAL. For use with Bayou Classic outdoor LP gas cookers/fryers ONLY! Do not use for any other application

UL Listed GM-20/25 and GM-40/45 Series Dual-block Multi-function Gas Control Valves

User Information Sheet 028

R E D I C O N T R O L S

APPROVED FOR USE IN SOUTH AFRICA STAINLESS STEEL STOVE

USER S INFORMATION MANUAL

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Prepared by a Joint Working Group of the International DME Association and the World LP Gas Association

Congratulations! Hand Held Torch. Warranty Policy PARTS

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

LIVE STEAMERS GAS FIRING CODE OF PRACTICE GAS FIRING OF AMBSC BOILERS AUSTRALIAN ASSOCIATION OF

INOGATE Technical Secretariat UK Experience European Standards Implementation Key Expert Phil Winnard Session 2 Georgia, October 2015

Safety in Petroleum Industry

200 PSI FAST-FILL AIR SOURCE KIT

FLAMMABLE GASES AND FLAMMABLE CRYOGENIC FLUIDS

Summary of the MRA LPG Codes of Practice

Class 2 Gases Learning Tool

INSTRUCTIONS FOR CONVERTING CONDENSING GAS MOBILE HOME FURNACES MODEL SERIES: CMA3*, CMC1*, VMA3*, VMC1*

Bottled Gas. Using LPG safely. for the way you want to live

RK LEL Sample Draw Aspirator Adapter Operator s Manual

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

Automatic Changeover Regulator with Over Pressure Shut Off (OPSO)

H15 Series BASO 100% Shutoff, Automatic Pilot Valve

Owner s Manual for Assembly, Operating & Maintenance of

No.IL02-OM00011-A PRODUCT NAME LOCK UP VALVE. MODEL/ Series IL201 IL211

Pressure Regulators. Operating Instructions. Instrumentation

SERVICE MANUAL SALAMANDER BROILERS RADIANT AND INFRARED 36RB 36IRB VULCAN C36RB C36IRB WOLF

VK8515M(R) MODULATING GAS CONTROL APPLICATION DESCRIPTION SPECIFICATIONS INSTRUCTION SHEET. Electrical data

LPG TANK INFORMATION An energy company that puts

Instruction Manual 742 5/1/2009. Eclipse Ratio Regulators ES Series Version 1

200 PSI HIGH-FLOW AIR SOURCE KIT

INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235)

Draft. Not yet Approved

Automatic Non-freeze Valve NF6

SAFETY STUDY OF HYDROGEN SUPPLY STATIONS FOR THE REVIEW OF HIGH PRESSURE GAS SAFETY LAW IN JAPAN

CSA Sample Draw Aspirator Adapter Operator s Manual

RK-IR Sample Draw Aspirator Adapter Operator s Manual

AS/NZS 1596:2014. The storage and handling of LP Gas AS/NZS 1596:2014. Australian/New Zealand Standard. Superseding AS/NZS 1596:2008

Your safety and the safety of others are very important.

Department of Physics Standard Operating Procedures (SOP) Approved by: Physics Safety Committee

G96 Series BASOTROL Dual Operator Valve

Confined Space Entry. My Experience so far.

User Information Sheet 015

WARNING: FOR OUTDOOR USE ONLY

CITY AND COUNTY OF DENVER CR&CF RISK UNIT Compressed Gas Safety Standard

ARCHIVED. Compliance Document for New Zealand Building Code Clause G11 Gas as an Energy Source. Prepared by the Department of Building and Housing

OWNER S MANUAL MODEL: PD1201 PORTABLE 2-BURNER GAS GRIDDLE

TYPICAL TOXIC GAS SYSTEM INSPECTION VIOLATIONS

Installation of Ballast Water Management Systems

GAS BBQ 4 burner. instructions for. model no: BBQ10

Inert Air (N2) Systems Manual

What is LPG? Released Energy in the narrowest area. Clean and sure in the practise

For use with select HPC Fire Pits ONLY- refer to product catalog or website. 100K BTU Maximum WARNING: FOR OUTDOOR USE ONLY

Liquid Gas Cylinder (LGC)

for Assembly, Operating & Maintenance of Model Big 60 II Gas Utility Stove THIS GAS UTILITY STOVE IS DESIGNED FOR OUTDOOR USE ONLY.

Health and Safety Guidance Note No 37

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

High Pressure Inlet Kits for CONCOA BlendMites and BlendMasters

INSTALLATION MANUAL TDR 8 P GAS FIRED ROTISSERIE OVEN

Vaporizer Technique. FAS Flüssiggas-Anlagen GmbH

Installation Instructions WARNING: WARNING: WARNING: LP AND HIGH ALTITUDE LP GAS CONVERSION KIT FOR UNITED STATES INSTALLATIONS

DSEAR- Storage, Use and handling of gas cylinders guidance.

N2 Blanketing Valve DST100 / DST200 TYPE INSTRUCTION MANUAL CONTENTS K.S.P.C. General Description Operation. Installation Maintenance

BRITISH STANDARD BS 341-4: Transportable gas container valves. Part 4: Pressure relief devices ICS

New Hampshire Public Utilities Commission CFR 49 Part 192 Regulations. MINIMUM Pipeline Safety Regulations

CNG/LPG Vehicles Emergency First Response Guide

Handling and Storage of Gases

Natural Gas Conversion Kit

User s Information Manual

Section 1.3: PRESSURE VESSEL COMPONENTS AND SYSTEMS AND COMPRESSED GAS CYLINDERS

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

INTEGRATED TYPE AUTOMATIC CHANGEOVER REGULATOR

HYDRAULIC INTENSIFIER Max. Pressure: See Intensifier Data Plate Weight: 16 Lbs. (7.26 kg)

ACCESSORY KIT INSTALLATION MANUAL

GM-7000 Series CE Approved Gas Control Valve

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

NGP-250/500 Nitrogen Generator Quick Start Guide

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

Gas Fired Residential Heating Boilers

A little technical and safety...

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

INSTALLATION & OPERATION MANUAL FOR Teppan-Yaki Griddles

HUPF Series DESCRIPTION APPLICATION INSTRUCTION SHEET GAS PRESSURE REGULATOR WITH INCORPORATED FILTER EN1C-0003NL05 R1205.

TESCOM 50-4X Series Safety, Installation & Start-Up Procedures

Having reviewed the Law on Constructional Organisation of Buildings promulgated by Legislative Decree No.(13) of 1977, as amended,

Transcription:

Annual Report on Liquefied Petroleum Gas (LPG) Related Accidents (2016 version) The High Pressure Gas Safety Institute of Japan (KHK)

1. Introduction This Annual Report describes accidents that occurred in 2016 related to facilities for supplies and consumptions of Liquified Petroleum Gas (hereinafter, LPG ) at home or on business, which are regulated by the Act on the Securing of Safety and the Optimization of Transaction of Liquefied Petroleum Gas (hereinafter, the LPG Act ). This report also describes analyses of the data of the accidents in 2016 by comparing with the past. 2. Definitions 2.1 Definition of accidents (1) LPG accidents [1] Leakage A case in which LPG leaked, but it did not catch fire and cause human damages of poisoning and asphyxiation. However, leakage of a very little amount of LPG from joints as little as soap bubbles formed when those of threaded parts or rubber tubes are soaked by soap water is excluded. [2] Leakage and explosion [3] Leakage and fire [4] Poisoning and asphyxiation Cases in which LPG leaked, and it resulted in an explosion or a fire caused by the explosion, as follows. A. Leakage and explosion, when the explosion resulted from leaked gas only. B. Leakage, explosion and fire, when a fire broke out following explosion caused by leaked gas. A case in which a fire resulted from leakage of LPG excluding those covered by [2] above. This is not limited to that recognized as a fire by the fire department. Here, a fire without leakage, which is caused by the overheating or the failure of LPG appliances including their accessories or by spreading of flames from a cooking oven, grill, etc., is not classified as a LPG accident. A case in which human damages of CO poisoning and asphyxiation are caused due to incomplete combustion, leakage of LPG, or leakage of exhaust gas from exhaust pipes, etc., at LPG consumption facilities. (2) Other accidents (not classified as LPG accidents) [1] Accidents caused by suicide, damage by intention, mischief, theft, or other similar causes [2] Accidents resulting from a natural disaster Example) Accidents caused by facilities damages resulting from collapse of houses due to earthquake Example) Accidents caused by facilities damages resulting from flood and landslide Even if accidents are resulted from natural disasters, however, those caused by defects in toppling prevention measures, fallen snow prevention measures (snow shelters, protective boards), or other insufficiencies in safety measures, are classified as LPG accidents. [3] Accidents involving portable cooking stoves and gas cartridges [4] Other accidents not categorized in the LPG accidents of (1) above 2.2 Classification of human damages Classified as follows according to the level of damage. Death: When a person was confirmed to have died within five days from the time of accident Seriously injured: When a person suffered an injury at the time of accident that took 30 days or more for full recovery Slightly injured: When a person suffered an injury at the time of accident that took less than 30 days for full recovery Copyright The High Pressure Gas Safety Institute of Japan 1

3. LPG accidents 3.1 Occurrences of accidents in the past It is noted a characteristic of accidents data in Japan that the number of leakage of gas, which has not caught a fire and caused no casualties due to poisoning or asphyxiation, is counted as a LPG accident. Figure 1: Accident occurrences and casualties by year Table 1: Change in the number of accidents and casualties by year Year Number of accidents Rate to the previous year Number of deaths Number of injuries Year Number of accidents Rate to the previous year Number of deaths Number of injuries 1967 1968 1969 1970 1971 1972 1973 1974 1975 1976 1977 1978 1979 1980 1981 1982 1983 1984 1985 1986 1987 1988 1989 1990 1991 167 112 170 217 217 299 368 540 497 581 638 570 793 761 714 570 559 545 496 515 401 390 306 262 194 34 33 52 28 0 38 23 47 8 17 10 11 28 4 6 20 2 3 9 4 22 3 22 14 26 33 38 69 44 33 52 59 74 40 65 56 72 63 60 50 43 51 36 35 42 29 37 36 27 13 271 146 236 283 301 398 389 679 543 523 684 640 825 758 723 650 645 529 550 477 381 336 327 233 171 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 146 112 82 88 101 68 75 79 78 87 90 120 105 105 219 239 234 185 204 227 260 210 187 178 136 25 23 27 7 15 33 10 5 2 12 3 33 13 0 109 9 2 21 10 11 15 19 11 9 42 31 7 3 12 14 6 9 5 8 2 4 7 2 1 0 4 4 4 5 1 1 3 1 2 0 162 135 83 80 109 64 82 66 73 69 64 86 88 58 78 98 79 148 83 88 85 52 76 60 52 Copyright The High Pressure Gas Safety Institute of Japan 2

Figure 1 shows the number of accidents that occurred between 1967 and 2016 and the resulting casualties. Looking at the data, the number of accidents increased gradually during the 1960s and the 1970s along with the number of households using LPG and reached a peak in 1979 with 793 accidents, causing 63 casualties. This was the year that marked the highest number of accidents and casualties. In July 1978, a part of the LPG Act was revised : measures such as dealer's obligation to general consumers, the establishment of a certified research institution system, etc. were implemented. In August 1980, a large-scale city gas explosion took place that resulted in enormous human damages marked by 15 deaths and 222 seriously and slightly injured persons. In February 1981, Ministerial Ordinance Reform was carried out : safety standards of the basement were established, installation of gas leak alarm equipment for LP gas for the basement and business facilities was obliged, and odor of LP gas concentration strengthened. Thereafter, the number of accidents continued declining linearly from the late 1980s, falling below 100 in 1994, to 82. Meanwhile, amendments to Act and Ministerial Ordinances were implemented several times. For example, in July 1985, the Ministerial Ordinance Amendment was implemented to strengthen the installation of end gas faucets (fuse gas stoppers) with excess overflow safety mechanisms and the connection method of rubber tubes for eating house. After that, initiatives for eradicating accidents, such as promoting the deployment of safety devices in conjunction with the public and private sectors, have been promoted. 3.2 Accident situations by phenomenon Table 2 shows the number of accidents by phenomenon that occurred between 2006 and 2016. Looking at that of 2016, the number of leakage-only accidents that did not start fire or explosion was more than half of total accidents. Compared to the previous year, the number of leakage-only accidents decreased by 17, leakage and explosion (fire) accidents decresed by 15. Table 2. Number of accidents by phenomenon 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 Leakage 137 113 115 84 76 116 160 113 98 98 81 Leakage and explosion(fire) 70 64 53 45 60 55 48 48 59 43 28 Leakage and fire (Excluding explosion) 6 51 60 42 60 45 44 43 27 31 18 CO poisoning and asphyxiation 6 11 6 14 8 11 8 6 3 6 9 Total 219 239 234 185 204 227 260 210 187 178 136 4. Analysis of accident situations The following kinds of LPG accidents that have occurred frequently were analyzed. (1) CO poisoning accidents As shown Figure 2, nine CO poisoning accidents occurred in 2016, showing an increased by five from the previous year. The breakdown of these accidents is shown below. [1] Poor air supply and exhaust because the windows were closed while using boiler, fryers or ovens. (three cases) [2] Poor air supply and exhaust because the ventilation fan was not operating while using the casting stove or the oven. (two cases) Copyright The High Pressure Gas Safety Institute of Japan 3

[3] Mishandling of combustion equipment. (two cases) [4] Typhoon wind and rain blown into the exhaust duct, and air supply and exhaust fault occurred due to closing doors and windows. (one case) [5] Blockage of supply and exhaust port of RF(Roof top Flue) type water heater by insulation material. (one case) (2) Buried pipes accidents Figure 2: Number of CO poisoning accidents by year and casualties The pipes that are installed between LPG cylinders and a gas meter are called supply pipes, and are installed between a gas meter and consumption devices like heaters are called distribution pipes in Japan. Pipes are installed on the ground or underground. The number of supply pipe accidents is greater than distribution pipe accidents. Figure 3 shows that 33 accidents involving buried pipes took place in 2016, a increase of five from the previous year. Causes of accidents include damages in 29 accidents (supply pipes in 23 accidents and distribution pipes in six accidents) and deterioration due to corrosion in four accidents (supply pipes in four accidents and distribution pipes in zero accidents). In many cases, damage is caused by a construction company erroneously cutting or breaking in a construction unrelated to gas facilities, causing gas leakage. In such a case, since people are involved directly and treatment such as gas stoppage is taken relatively quickly, most of them have not reached a large-scale accident. Figure 3. Number of buried pipes accidents by year and casualties Copyright The High Pressure Gas Safety Institute of Japan 4

(3) Bulk supply accidents In 2016, five accidents involving bulk supply (supply facilities only) occurred, showing a increase of one from the previous year. The breakdown of these accidents is shown below. *Bulk supply refers to supply of liquefied petroleum gas into bulk storage tanks from portable LPG generators (bulk tank trucks). See Figure 4. [1] Work mistake at replacement of safety valve. (one case) [2] Clogging failure of gas extraction valve. (one case) [3] Safety valve release pipe deterioration. (one case) [4] Production defective of liquid extraction valve neck part. (one case) [5] Aged deterioration of pressure gauge packing. (one case) Protector Figure 4. Bulk supply system Pressure Relief Device Regulator Liquid Inlet Valve Gas Outlet Valve Liquid outlet valve Level Gauge Filling Port Figure 5: Bulk Storage Tank Copyright The High Pressure Gas Safety Institute of Japan 5

5. Number of accidents that resulted in death or injured Number of the accident that described so far contains non death and non injured cases. Of course, most of the leakage only accident didn t result in death or injured. Table 3 and Figure 6 show the number of accidents that resulted in deth ore injured by phernomenon. Table 3. Number of accidents that resulted in death or injured by phenomenon Leakage Leakage and explosion (Fire) Leakage and fire (Excluding Explosion) CO poisoning and asphyxiation Total 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 Number of accidents 3 5 0 1 0 1 0 1 1 1 Number of deaths 0 0 0 0 0 0 0 0 0 0 Number of injuries 3 7 0 1 0 2 0 1 1 1 Number of accidents 44 36 25 38 32 27 24 38 22 16 Nnumber of deaths 1 1 1 1 0 0 0 0 1 0 Number of injuries 54 45 39 49 39 33 30 50 37 21 Number of accidents 12 15 17 17 11 10 15 9 8 1 Number of deaths 1 1 0 1 0 0 0 0 0 0 Number of injuries 12 20 24 17 15 13 17 21 8 1 Number of accidents 11 6 14 8 11 8 6 3 6 9 Number of deaths 2 2 3 3 1 1 3 1 1 0 Number of injuries 29 8 85 16 34 37 5 4 14 29 Number of accidents 70 62 56 64 54 46 45 51 37 27 Number of deaths 4 4 4 5 1 1 3 1 2 0 Number of injuries 98 80 148 83 88 85 52 76 60 52 Figure 6: Number of accidents by phenomenon that resulted in death or injured Copyright The High Pressure Gas Safety Institute of Japan 6

Contact for inquiries related to this document The High Pressure Gas Safety Institute of Japan (KHK) Information & International Affairs Department International Affairs Division 4-3-13 Toranomon, Minato-ku, Tokyo 105-8447 TEL: +81-3-3436-2201 FAX: +81-3-3438-4163 Web: http://www.khk.or.jp/english/index.html MAIL: oversea@khk.or.jp Copyright The High Pressure Gas Safety Institute of Japan