ChlorTainer is the safest, most reliable technology available for processing and preventing a chlorine gas release.

Similar documents
CO 2. (R744) Service Station Presentation. Contents. Goals Basic functions Specification Recovery R477 Vacuum Charge Safety Other features Prototype

Valve Closure Systems for 1-Ton Containers or 150-Pound Cylinders

Mitigation Starts With Design! Continues with Safe Operation, Mechanical Integrity and Training!

Maintenance and Troubleshooting of Pneumatic Conveying Systems for Sand in a Foundry

CAPITAL CONTROLS SERIES NXT3000

Section 1.3: PRESSURE VESSEL COMPONENTS AND SYSTEMS AND COMPRESSED GAS CYLINDERS

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200

Trifecta Systems. Cryogenic Equipment for High Performance Gas Supply. Trifecta Product Catalog

Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability.

Vaporizer Piping Liquid Chlorine Manifolds

BULLETIN 901 SAFE RELIABLE ECONOMICAL REGAL GAS CHLORINATORS SULPHONATORS AMMONIATORS

TYPICAL TOXIC GAS SYSTEM INSPECTION VIOLATIONS

Trifecta High-Pressure Systems

Chlorinator MODEL MK-I

Contents. Foreword. Acknowledgements. General Introduction

V10K GAS FEED SYSTEM WALLACE & TIERNAN PRODUCTS

This written Compressed Gas Plan is kept at the corporate office and in the written Safety & Health Program.

Custom-Engineered Solutions for the Nuclear Power Industry from SOR

Section 1. Registration Information

Usage Policies Notebook for Trion RIE / ICP Dry Etch

Usage Policies Notebook for NanoFurnace Furnace (EasyTube 3000 System)

5.0 INSPECTING, FILLING AND LABELING SMALL CYLINDERS

Instruction Manual VCG-6

Farm Chlor Chlorinator Instruction Manual

GCE CENTRAL GAS SYSTEMS THE DRINKS DISPENSE INDUSTRY EQUIPMENT FOR GAS SUPPLIER SYSTEMS

P6 PRODUCTION CONFINED SPACE LOG

FUNDAMENTALS OF PRESSURE RELIEF VALVES IN NATURAL GAS INSTALLATION - OPERATION - MAINTENANCE. Gary S. Beckett

GW DRY PIPE VALVE INSTALLATION & OPERATION 100mm (4 ) 150mm (6 )

MEDICAL EQUIPMENT CATALOG

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N

Operating Instructions Model and Hydrostatic Test Pump

13. Evaporative Emission Control System

Equipment Operating Procedure Glove Box

Vacuum Insulated vertical cryogenic CO 2 & N 2 O Tanks

OPERATION MANUAL NTF-15

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

OPERATION MANUAL NTF-60 Plus

The Original 24/7 PMO Valve and 24/7 PMO Tank Valve. The only way to non-stop production. GEA Mechanical Equipment / GEA Tuchenhagen

6.6 Relief Devices. Introduction

SERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL.

University of MN, Minnesota Nano Center Standard Operating Procedure

Installation, Operation and Maintenance Instructions for Mild Steel Buffer Vessel

Safe Handling. of Chlor Alkali Products

PURPOSE OF THE POLICY

Highest Quality. Gas Chlorination Systems

CO 2 and O 2 scrubbers

Relief Systems. 11/6/ Fall

Installation and Maintenance Manual. ECO Filtration Unit with 6-way-Top-Mount-Valve. Art. Nr

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

LPG TANK INFORMATION An energy company that puts

Atmospheric Hazards. Hazardous Atmosphere 3/29/2017. Oxygen deficiency and enrichment Flammable gases and vapors Toxic contaminants

Introduction to Emergency Response & Contingency Planning

Drum / cylinder handling

Gas Cabinets and Valve Manifold Boxes: Applying CGA G13- Rev 2015 to Gas Delivery Equipment

COMPRESSOR MANUAL. (888)

Department of Physics Standard Operating Procedures (SOP) Approved by: Physics Safety Committee

Compressed Gas ER Fundamentals

Required Indoor Draft Hood. Optional Outdoor Vent Cap

I. Subject: Medical Gas Systems Utility Failure Interim Procedure III. Purpose:

LOCKOUT SYSTEM AND POLICIES

Instruction Manual - Diaframless TM Ejector Chlorine, Sulfur Dioxide and Ammonia

FLAMMABLE GASES AND FLAMMABLE CRYOGENIC FLUIDS

ZUERCHER TANK REGULATORS PRINCIPLES OF TANK VENTILATION

955108_2. AirForce Operator s Guide

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

R E D I C O N T R O L S

APPS-160 Gen 2 User Manual

Neil Kane Managing Director EMT UK

ACV-10 Automatic Control Valve

Valve Closure Systems for Plug-Type Angle Valves or Ball-Type Angle Valves

Engineered Valves Group. Revision 2. FABRI-VALVE High Performance Knife Gate Valve.

PART 1 GENERAL..2 Components of the gas chlorination system include, but are not limited to the following:

By Zane Satterfield, P. E. NESC Engineering Scientist Photos by Julie Black NESC Web Developer

NIV EAU MATIC ST User Manual Made in Canada

Operating Instructions Models and Hydrostatic Test Pumps

GUIDELINES FOR CONDUCTING HYDROGENATION REACTIONS

ACME Connectors and Fittings Extended Type Hose Couplings for Vapor and Liquid Service A7571 and A7575 Series

STANDARDS FOR WATER WORKS

Calorimeter Selection Criteria

Inert Air (N2) Systems Manual

Safety, Operating and Maintenance Manual. TRAIN Rat DS9-TRAIN

Developments on Flow Rate And High Pressure Stability of Peroxide Dosing Pumps For The Chemical Industry

Module No. # 01 Lecture No. # 6.2 HAZOP (continued)

GETZ EQUIPMENT INNOVATORS RECOVERY SYSTEM CLEAN AGENT FE-36 / HALOTRON 1 PART NO. 4G59751 OPERATIONS MANUAL

Chemical Injection Technologies Installation/Service Bulletin

Series 7250 Ruska High-Speed Digital Pressure Controller. GE Sensing. Features

FE Petro vs. New Red Jacket Competitive Comparison

Taking care of the world s water. Wallace & Tiernan Products V10k Gas Feed System

SUBSTATION MAINTENANCE ELECTRICAL OPERATING PROCEDURE

Horizontal Bladder Tanks

Oxygen Generating Systems Ozone Medical Welding Glassblowing Aquaculture Pulp & Paper Wastewater

VACCUPERM Vacuum chlorine gas dosing systems

200 PSI COMPRESSORS - MODEL NUMBERS

Vertical Bladder Tanks

Simplicity in VRU by using a Beam Gas Compressor

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

OPERATING INSTRUCTIONS AND PARTS LIST AUTOMATIC FILLING MACHINE DE-401-GB-AUTO

AFDXXX(X)AC Series Operators Manual Please read this manual thoroughly before attempting to operate your water maker.

Per Section I of the ASME

Transcription:

ChlorTainer is the safest, most reliable technology available for processing and preventing a chlorine gas release.

Safest Technology Available ChlorTainer will reduce the area affected by 97%, providing the safest technology to operators and the surrounding community.

What is ChlorTainer? ChlorTainer is a high-pressure secondary containment vessel into which a 1-Ton or 150-lb chlorine gas cylinder is processed. It can also be used with sulfur dioxide and anhydrous ammonia. All vessels are built to ASME code and can easily withstand the maximum pressure produced by a failed cylinder. If the cylinder should leak, chlorine gas is contained within the vessel and processed at a normal rate. All of the chlorine gas is used, and no hazardous waste is generated.

In the event of a leak inside ChlorTainer, what do you do? ABSOLUTELY NOTHING. Continue to process at a normal rate until all of the chlorine is used Because the system is under vacuum, there is no waste

Vacuum Pressure Gauge The pressure gauge and switch is used to detect a chlorine leak from a chlorine gas cylinder while it is sealed within ChlorTainer. Signal is sent to SCADA and Operator notified of release Chlorine processes at normal rate until scale shows cylinder is empty Vacuum regulator transfers to secondary Bossett for leaked gas to process at normal rate The contained chlorine gas cylinder is allowed to operate until emptied before the containment system vessel door can be reopened

Minimal Maintenance Replace the O-ring on the door once a year Repack fail-safe ball valve once every five years Annual cost is $200 and takes about half an hour of time

In a worst case release scenario, ChlorTainer will reduce the area affected by 97% ChlorTainer is considered passive it does not require any electronic or mechanical devices to contain a release Built to ASME code Can easily withstand the maximum pressure produced by a failed cylinder Includes scale loader and SCADA options Long life expectancy with minimal maintenance Made in the USA Dependable & Reliable The simpler things are, the less likely they are to fail.

Loader Customization to Meet Your Needs

Ease of Installation ChlorTainer simply bolts down to the ground Can be installed indoors or outdoors, as long as it is sheltered from direct sunlight and rain

Single 150 Container Vessel Built to accommodate one 150-pound chlorine cylinder, the single ChlorTainer vessel comes with a 2-bolt chaindrive door that opens and closes in less than a minute

Twin 150 Container Vessel The Twin Container Vessel is built to accommodate two 150-pound chlorine cylinders. In twin cylinder mode, both cylinders are processed simultaneously.

Dual 150 Container Vessel Accommodates two 150-pound chlorine cylinders. Gas from only one cylinder is processed at a time. When the first cylinder is empty, the feed is automatically switched to the second cylinder. In the event of an external release, the chlorine sensor will detect the leak and send a signal to the fail-safe valve, which will then cycle close.

Benefits of ChlorTainer ChlorTainer is the only system that reduces the worst-case offsite release of toxic gas by 97% Eliminates the need for scrubber systems, fans, pumps, tanks, or mechanical systems Eliminates the need for an OSHA Emergency Response Team Provides safe, dependable, and trouble-free operation Can be installed indoors or outdoors as long as it is sheltered from direct sunlight and rain ChlorTainer is intended to be used as a process system Works to provide safety containment not only for chlorine gas, but also sulfur dioxide and anhydrous ammonia System is defined as passive for the purpose of the RMP ChlorTainer can be connected to several safety devices such as SCADA, chlorine detection, or seismic detection ChlorTainer enhances site security and provides fail-safe protection for plant operators Locking doors prevent unauthorized access to the chlorine cylinders

Contact Us Today to Get Started! (800) 543-6603 www.chlortainer.com sales@chlortainer.com