A complete family of Pediatric Perfusion Systems

Similar documents
INSPIRE Min.I. Redefining minimally invasive approach to perfusion. Expand your choices with INSPIRE Min.I.

INSPIRE TM C The integrated closed system oxygenator for gentle perfusion

INSPIRE Oxygenator Family

Patients come in a range of sizes. Now your oxygenator does, too.

CAPIOX FX Advance. Oxygenator with Integrated Arterial Filter and Hardshell Reservoir

QUADROX-i Neonatal & Pediatric Maximum safety for the smallest patients.

INSPIRE TM8 PH.I.S.I.O.

INSPIRE TM Inspired choice

CAPIOX SX Family of Oxygenators

Prescriptive Oxygenation

CAPIOX SX Family of Oxygenators

CAPIOX SX Family of Oxygenators

OxygenatOrs QUaDrOx-i adult QUaDrOx-i small adult

Adult All Integrated Mini Bypass System

1.060 Set-Up and Priming of the Bypass Circuit. Perfusion Technology Department. Perfusionists

INSPIRE 6 PH.I.S.I.O.

Heart/Lung Perfusion Packs INSTRUCTIONS FOR USE

Optimized Perfusion Management and Patient Outcome

ila ACTIVVE SYSTEM PLATFORM

Clinical Engineering. Equipment (Heart-lung machines)

Considerations in Circuit Miniaturization

Emboli Production in Hardshell Venous Reservoirs at Low Reservoir Levels Devin Eilers, BS, Willie Glaze, BS, & David Holt, MA, CCT Clinical Perfusion

Blood Parameter Monitoring System 550

InFlow Modular perfusion bioreactor

CDI Blood Parameter Monitoring System 500 A New Tool for the Clinical Perfusionist

Min.I. Mini Maxi Me. The proven safe and reliable, world-leading perfusion system, now optimized for minimally invasive and pediatric surgery

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings

Citation for published version (APA): Somer, F. M. J. J. D. (2003). Strategies for optimisation of paediatric cardiopulmonary bypass s.n.

Making Life Easier Easypump II

Indications for Use: Caution: Note:

The next generation of Blood and Fluid Warming

CRRT with Prismaflex LEADS TO More Flexibility, Ease of Use and Safety

Quiz for Module 2: Aquarius Training (Rev. 1) Lesson 1: Introduction to Aquarius

CDI System 500. Blood Parameter Monitoring System. Continuous blood parameter monitoring for improved blood gas management

Chest Drainage Systems for Cardiac & Thoracic Surgery. Including portable suction with Digital Air Leak Monitoring

S5 TM. Min.I. Mini Maxi Me. The proven safe and reliable, world-leading perfusion system, now optimized for minimally invasive and pediatric surgery

(12) United States Patent (10) Patent No.: US 6,524,267 B1

Errors in Flow and Pressure Related to the Arterial Filter Purge Line

Contacts. Quick Start Guide

Point-of-Care Testing: A Cardiovascular Perfusionist s Perspective

The next generation of Blood and Fluid Warming

New Generation System M, leading the World in the Non-Invasive Measurement of Critical Real-Time Parameters.

Equipment and monitoring for cardiopulmonary bypass

ENT 318/3 Artificial Organ. Artificial Lung. Lecturer Ahmad Nasrul bin Norali

Solutions for transcutaneous monitoring

Endo-Flush Order # ZUTR30004 OPERATION MANUAL. Zutron Medical, LLC W 98 th St #40-27 Lenexa, KS Phone Fax

Effects of Purge-Flow Rate on Microbubble Capture in Radial Arterial-Line Filters

Alfred ECMO Circuit Priming and Storage Guide

Corporate Overview and Product Summary

Blood Pressure Monitoring: Arterial Line

Concentrate Distribution System (Stand Mounted) A-CDS-70-X & A-CDS-TANK-X-ST Industrial Drive, Orlinda, TN 37141

Water Weir Flow Controller. Introduction. Safety Precautions. Mounting the Hardware

MyoSure Setup Simplified

User Manual. Model 3930 Vacuum Assisted Venous Drainage Controller w/ WAGD Suction Flowmeter

Filtration FILTRATION PRODUCT TIPS

The NAMIC Dream Kit. Single Operator Control. Reduce Contrast Waste. Less Force to Inject. Compensator * Manifold. How the Compensator Manifold Works:

Development of a New Hollow Fiber Silicone Membrane Oxygenator for ECMO: The Recent Progress

Kieron C. Potger, CCP, BSc, Dip Perf, MClinN; Darryl McMillan, CCP, Dip Perf; Mark Ambrose, CCP, BNurs, Dip Perf

HAEMOFILTRATION GUIDELINES

GA-300 Gas Analyzer. Technical Note. Overview. Front Panel. iworx Systems, Inc. GA-300

User Manual. Model 3930 Vacuum Assisted Venous Drainage Controller w/ WAGD Suction Flowmeter

Boehringer Model Vacuum Assisted Venous Drainage. Frequently Asked Questions

HIGH FREQUENCY JET VENTILATION (HFJV): EQUIPMENT PREPRATION

Bloodlines, Tubing Systems, Accessories

NEXUS TKO. Specialty Neonatal/Pediatric. Safety Infusion Sets. Blood Reflux Protection 24/7! Anti-Reflux Technology Provides

BIOSTAT CultiBag RM Culturing Convenience

Regulators/valves Compressed air regulators Without filter

Specifications...Easy CLIA Classification: Sample Type: Blood gas analyzer operation has never been simpler Sample Size: Measured Parameters PCO2

User s Guide. Vacuum Controller for liquid delivery systems

Limitations Using the Vacuum-Assist Venous Drainage Technique During Cardiopulmonary Bypass Procedures

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

Unity Sleeveless Elevated Vacuum System

EASYPUMP II THE FLEXIBLE SOLUTION FOR SHORT AND LONG TERM INFUSION THERAPIES

INTERNATIONAL MARKETING. 61, avenue Tony Garnier Lyon France Tel.: 33 (0) Fax: 33 (0)

Limb Perfusion Device

1st Response Disposable Manual Resuscitators. Safe Convenient Trusted

3-Way Decoking Valve Option - Installation and Operation Instructions Accessory G Background

UNITS /2017-E ENDOFLATOR 50. The New High-Performance Insufflator with Integrated Heating Element from KARL STORZ

Diacan and Diacan S. The safe and gentle vascular access for dialysis

(Delivery System) Pocket Guide. Series 3 software

Evaluation of Blood Cardioplegia Administration Systems

Blease900 Ventilator PATIENT CENTERED VENTILATION

User s Guide. CO2 Controller for miniature incubators

Recommendations for Standards. Monitoring. Cardiopulmonary Bypass

fabian Therapy evolution Our 2-in-1 device

PERFUSION SYSTEMS MECC SMART SMART SUCTION SYSTEM

Keep the balance in sight

PANACEA P200 STAINLESS STEEL USER MANUAL

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator

BPS-2, Rev TABLE OF CONTENTS

V-Green Protect-A-Line A range of drug-compatible extension lines designed to enhance patient safety during IV therapy.

Customer Responsibilities

Haemodialysis. Bloodlines, Tubing Systems, Accessories Product Range. Product name / Headline Subline

GE Healthcare. Aestiva/5. More than superior ventilation

An In-Vitro Study Comparing the GME Handling of Two Contemporary Oxygenators

Oxygenator Safety Evaluation: A Focus on Connection Grip Strength and Arterial Temperature Measurement Accuracy

Simplicity and Safety Prevention Efficiency and Biocompatibility

Improve Reliability of Turbomachinery Lubrication and Sealing Systems

MANITOBA RENAL PROGRAM

Innovative cap to reduce the noise raised by bubbling activity drainage working (vent close)

Transcription:

LEADING THE FIELD OF PEDIATRIC PERFUSION FOR OVER 25 YEARS A complete family of Pediatric Perfusion Systems

Perfusion systems designed for the broadest range of pediatric patients Small, sensitive neonatal and pediatric patients deserve dedicated perfusion systems. The Dideco KIDS line of pediatric oxygenators and arterial filters are the latest from a long history of pediatric perfusion advancements from Sorin Group. Designed to minimize hemodilution and reduce foreign surface area exposure, Dideco KIDS provides optimal clinical flexibility and perfusion support to a broad range of neonatal and pediatric patients. Low Priming Volume For true neonates, the D100 oxygenator and D130 arterial filter provides the smallest priming volume of any pediatric perfusion system in clinical use, just 47 mls. For larger pediatric patients, the D101 oxygenator and D131 arterial filter offer the ideal balance between high performance and low priming volume: only 115 mls for patients up to 2.5 LPM blood flow. Low Surface Area At 0.22 m 2, the D100 membrane is sized for neonatal patients without unneeded surface area. The D101 s 0.61 m 2 membrane is sized for a wide range pediatric patients. Advanced Reservoir The D100 and D101 reservoirs include features that optimize performance but make set-up easy for adult fingers. Luer lock connectors on D100, to allow small tubing to be connected easily and quickly Integrated pressure relief valve for safer use with vacuum assisted drainage Low minimum operating level only 10 ml for D100 and 30 ml for D101 Unique hybrid cardiotomy filter (both screen and depth fiter) to reduce hold up volume and foreign surface contact Intuitive, Fast and Easy Set-Up The brackets hold each oxygenator securely with simple latches that are easy to use and maintain. The luer lock connectors on the D100 cardiotomy lid allow connection without trying to manipulate small diameter tubing onto barb ports. The gas inlet is located on the top of each oxygenator, and the reservoir can be rotated as needed to optimize visibility. Hansen fittings on the side of the oxygenators make water connections easy. The D130 and D131 arterial filters utilize purge lines on both sides of the filter to make priming fast and easy. In the event of massive air in the arterial line, priming is made easier by purging both sides of the filter screen. High Biocompatibility To deliver the best possible care for your neonatal and pediatric patients, Sorin Group has developed highly biocompatible products that feature phosphorylcholine (PC) coating. PC treatment provides a stable coating, which is demonstrated to be effective in improving platelet preservation and reducing platelet foreign surface adhesion. 1 1 DeSomer, et al. Phosphorylcholine coating of extracorporeal circuits provides natural protection against blood activation by the material surface. European Journal of Cardiothoracic Surgery 18 (2000) 602-606.

D101 Infant Oxygenator D131 Infant Arterial Filter Designed for the WIDEST RANGE of pediatric patients D100 Neonatal Oxygenator D130 Neonatal Arterial Filter The WORLD S SMALLEST perfusion devices, specially designed for the smallest of patients

Performance Data D100 D101 Performance data: D100 and D101 In vitro tests with bovine blood at AAMI standards conditions Hgb: 12 ± 0,2 g/dl B.E.: 0 ± 5 mmol/l Blood Temp.: 37 ± 1 C O 2 Venous Sat.: 65 ± 5 % Venous pco 2 : 45 ± 5 mmhg Water flow rate at water side = 10 lpm

Minimized Surface Area The D100 and D101 utilize a circumferential flow path to increase the efficiency of the membrane surface area in the oxygenator. As a result, surface area exposure is minimized, keeping O 2 and CO 2 transfer rates balanced. By not having excess surface area, more precise CO 2 control is possible at lower rates. Dideco KIDS D130 and D131: the World s Smallest Arterial Filters The D130 and D131 arterial filters provide purge lines on both sides to make priming fast and easy. Optimal Reservoir for the Smallest Patients Matching the reservoir design to the patient size is an important step toward minimizing circuit volume. Our sequential cardiotomy filter automatically minimizes the filter surface area in contact with the blood while adjusting to the incoming flow volume. The optimal reservoir shape and venous filter allow operation at extremely low levels: 10 mls for D100 30 mls for D101 S5 Mast Mounted Pumps and Dideco KIDS Oxygenators and Arterial Filters Work Together We have optimized both the pump and circuit design to further reduce prime volume.

Product Specifications D100 Oxygenator STATIC PRIMING VOLUME (ml)... 31 MEMBRANE SURFACE AREA (m 2 )... 0.22 MAX BLOOD FLOW (maxflow, ml/min)... 700 Reference Flow AAMI (ml/min)... 1000* DP @ maxflow (mmhg)... 175 HEAT EXCHANGER SURFACE AREA (m 2 )... 0.03 HEAT EXCHANGER EFFICIENCY @ maxflow (%)... 65 HARDSHELL RESERVOIR Capacity (ml)... 500 Minimum Operating Level (ml)... 10 Cardiotomy Filter Pore Size (mm)... 33 Venous Filter Pore Size (mm)... 51 Pressure Relief Valve... +5/-80 mmhg OXYGENATOR MODULE CONNECTIONS Venous Inlet... 3/16 1/4 Arterial Outlet... 3/16 HARD-SHELL RESERVOIR CONNECTIONS Venous Return... 3/16 1/4 Outlet... 3/16 1/4 Filtered Ports: Product Specifications D101 Oxygenator STATIC PRIMING VOLUME (ml)... 87 MEMBRANE SURFACE AREA (m 2 )... 0.61 MAX BLOOD FLOW (maxflow, ml/min)... 2500 Reference Flow AAMI (ml/min)... 3500* DP @ maxflow (mmhg)... 155 HEAT EXCHANGER SURFACE AREA (m 2 )... 0.06 HEAT EXCHANGER EFFICIENCY @ maxflow (%)... 61 HARDSHELL RESERVOIR Suction Inlets... 7 x LL Vertical Inlet... 3/16 Unfiltered Port... LL *AAMI reference flow is the flow in which oxygen delivery equals 40 ml/min/l of blood flow under AAMI standard conditions (35% Hct, 37C, Hgb=12 mg/dl, FiO2=100%). Capacity (ml)... 1500 Minimum Operating Level (ml)... 30 Cardiotomy Filter Pore Size (mm)... 33 Venous Filter Pore Size (mm)... 51 Pressure Relief Valve... +5/-80 mmhg OXYGENATOR MODULE CONNECTIONS Venous Inlet... 1/4 Arterial Outlet... 1/4 HARD-SHELL RESERVOIR CONNECTIONS Venous Return... 3/8 1/4 Outlet... 1/4 Filtered Ports: Suction Inlets... 3 x 1/4 + 2 x 3/16 Vertical Inlet... 1/4 Additional Inlets... 4 x LL Unfiltered Port... LL PRODUCT SPECIFICATIONS D130 ARTERIAL FILTER STATIC PRIMING VOLUME (ml, weighed)... 16 MAX BLOOD FLOW (ml/min)... 700 PORE SIZE (μm)... 40 CONNECTIONS Inlet Connector... 3/16 Outlet Connector... 3/16 Purging Lines... 2 x LL Ordering Information Description Code D100 Dideco KIDS Neonatal Oxygenator with Hardshell Reservoir, Phisio coated 050531 D130 Dideco KIDS Neonatal Arterial Filter, Phisio coated 050538 D633 Oxygenator Bracket 05083 D634 Arterial Filter Bracket 050539 Product Specifications D131 ARTERIAL FILTER STATIC PRIMING VOLUME (ml, weighed)... 28 MAX BLOOD FLOW (ml/min)... 2500 PORE SIZE (μm)... 40 CONNECTIONS Inlet Connector... 1/4 Outlet Connector... 1/4 Purging Lines... 2xLL Ordering Information Description Code D101 Dideco KIDS Infant Oxygenator with Hardshell Reservoir, Phisio coated 050540 D131 Dideco KIDS Infant Arterial Filter, Phisio coated 050542 Trust Sorin Group to deliver the innovations that continue to advance pediatric perfusion. *AAMI reference flow is the flow in which oxygen delivery equals 40 ml/min/l of blood flow under AAMI standard conditions (35% Hct, 37C, Hgb=12 mg/dl, FiO2=100%). 2008 Sorin Group Caution: Federal law (USA) restricts this device to sale by or on the order of a physician. Sorin Group USA, Inc. 14401 W. 65th Way, Arvada, CO 80004 800.221.7943 303.467.6584 fax www.soringroup-usa.com Part number 306300154 Rev C (05/08) Printed in U.S.A.