Digi Connect ME 9210 Linux: serial port 2 for JTAG modules

Similar documents
Digi Connect ME 9210 Linux: 2 nd serial over FIM

Setting Up the Ingenico isc250 Pinpad via USB

Setting up the Ingenico isc250 Pinpad via USB in Windows 8

IBU3 Manual Addendum 1

Using the Lego NXT with Labview.

BASnet LightiView Install Guide

Drag Racing Scoreboards

215 Liquid Handler Up-Grade Manual

Instrument pucks. Copyright MBARI Michael Risi SIAM design review November 17, 2003

ELIMINATOR COMPETITION DRAG RACE Program Manual Firm Ver 4.11

Product Overview. Product Description CHAPTER

T i m i n g S y s t e m s. RACEAMERICA, Inc. P.O. Box 3469 Santa Clara, CA (408)

1. Hardware...2. Hardware Connection... Connection Diagram... DIP Switch Setting... & 0 PIN Button Layout...

What to Expect at Your First FTC Tournament. Eric Grajales Mike Nicolai September 17, 2011

UG4: OPEN HAB. Elelabs ZigBee RPi Shield firmware version, referenced in this guide: OpenHab2 software version, referenced in this guide: v2.3.

SCIENTIFIC DATA SYSTEMS, INC. Depth Tension Line Speed Panel. DTLS Manual

Race Screen: Figure 2: Race Screen. Figure 3: Race Screen with Top Bulb Lock

MASK INTEGRITY TEST ACCESSORY (MITA) MODEL 8120

XC2 Client/Server Installation & Configuration

1. Hardware Hardware Connection... 2 Connection Diagram... 3 DIP Switch Settings & 10 PIN Button Layout... 4

Drag racing system HL190 User Manual and installation guide

Oxygen Meter User Manual

Edgecore ASFvOLT16 VOLTHA Adapter and Driver. Kim Kempf, Sr. Systems Architect CORD Build 2017, San Jose November 8, 2017 MT08.3.

Instruction Manual. Smartinterface serial

Wickets Administrator

WELCOME TO THE REVOLUTION

1001ICT Introduction To Programming Lecture Notes

Configuring Bidirectional Forwarding Detection for BGP

VOLAR PRODUCTION TRUCK SCOREBOARD CONTROLLER DATA INTEGRATION

Stand-Alone Bubble Detection System

Track and Field Interface

Air Bubbler Depth Gauge DG2200 Installation and Reference Manual

FireHawk M7 Interface Module Software Instructions OPERATION AND INSTRUCTIONS

SENSUS PRO MANAGER (for SENSUS or SENSUS PRO devices) User s Guide -- Windows. Version 2.0 Published October 17, ReefNet Inc.

1. Hardware Bookkeeping & Adjustment...7. Access Flow Chart... 7 System Adjustment... 8 Chance Adjustment... 9 Touch Screen Calibration...

Instruction Manual. BZ7002 Calibration Software BE

OPERATION MANUAL DIVE CALIPER NOT SCALE / IF IN DOUBT ASK* *ALL UNITS IN MM/DEGREES UNLESS SPECIF. Dive Caliper General DC-051

DIVE MEET SCORING INSTRUCTIONS. Day before meet

SHIMADZU LC-10/20 PUMP

Please note. Right now, the ongoing version of emax (3.9C) is not already completely compatible with the newest firmware version of Shimano!

Domino DUEMMEGI. Domino. Communication Interface DFTS User s Manual. Release September 2007

Reconfigurable Computing Lab 01: Traffic Light Controller

D-Opto Dissolved Oxygen Sensor Operation Manual for the D-Opto 4-20mA

Education and Research

EZ Boom 2010 System for the EZ Guide 500 Lightbar Triangle Ag Services Users Guide

KEM Scientific, Inc. Instruments for Science from Scientists

SECTION 2 SMART PAYOUT MANUAL SET FIELD SERVICE MANUAL

The examples below are a starting point, and some fine tuning may be required.

1. Hardware Bookkeeping & Adjustment Access Flow Chart... 6 System Adjustment... 7 Chance Adjustment... 8 Touch Screen Calibration...

STAND alone & p.c. VERSION

PC Configuration software for Discovery MkVI v 1.03 User guide

TR Electronic Pressure Regulator. User s Manual

Perfect Golf Quick Start Guide

HyperSecureLink V6.0x User Guide

CONSUMER MODEL INSTALLATION GUIDE

RaceAmerica Corporation 105 Bonaventura Drive San Jose, CA (408)

D-Opto Dissolved Oxygen Sensor Operation Manual

APPLICATION NOTES. WIND MEASURING SYSTEMS using XDi-N indicators. Document no.: B

Operating Manual. SUPREMA Calibration. Software for Fire and Gas Warning Units. Order No.: /01. MSAsafety.com

Upgrading Bio-Plex Manager 4.1, 5.0, or 6.0 Software to Bio-Plex Manager 6.1 Software

Document Number: 239/34000/76 Revision: (-) 2009-Apr-13

REMOTE CLIENT MANAGER HELP VERSION 1.0.2

HART Communications Board

Technical Bulletin, Communicating with Gas Chromatographs

AGW SYSTEMS. Blue Clock W38X

AN-140. Protege WX SALLIS Integration Application Note

PRODUCT MANUAL. Diver-Mobile for Android

CONSOLE-320 ENGLISH. 230A: CONSOLE-320 with cable data output Item 230B: CONSOLE-320 with cable + wireless radio data output

Gas Analyzer for TC Sensors (CO2, H2, N2) Series 62101, 64101, Operating Manual

Airflow Options for Cisco MDS 9396S SAN Switch

RM-80 respiration monitor

Previous Release Notes

Sontek RiverSurveyor Test Plan Prepared by David S. Mueller, OSW February 20, 2004

Version 3.1.0: New Features/Improvements: Improved Bluetooth connection on Windows 10

BGA244 Binary Gas Analyzer

User s Guide. Pressure Controller for liquid delivery systems

INSTALLATION INSTRUCTIONS AND REFERENCE HANDBOOK

Getting to know your Sureshotgps micro V3

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

FOOD INTAKE MONITOR. Hardware and Software User s Manual DOC-047 Rev 3.0. Copyright 2009 All Rights Reserved

DST Host User Manual

Steltronic StelPad User Guide

Diver-Office. Getting Started Guide. 2007, Schlumberger Water Services

Rescue Rover. Robotics Unit Lesson 1. Overview

μsmartdigi Presented at Ham-Com 2008 Plano Texas June 2008 by Rich Painter, AB VO Painter Engineering, Inc.

This document contains recommendations that may help teams be more successful in preparing for and participating in the FTC World Championship Event.

OMNISPORT 2000 SWIMMING QUICK REFERENCE

unconventional-airsoft.com

This addendum describes the back pressure control implementation if FuelCell Version 4.1a and later.

Connect with Confidence NO POWER NO PROBLEM

Grove - Gas Sensor (O2)

APPLICATION NOTE. OJ-DV Modbus protocol. OJ Drives A DRIVES PROGRAMME DEDICATED TO VENTILATION SOLUTIONS E 03/18 (PDJ) 2018 OJ Electronics A/S

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

SomnoSuite Low Flow Anesthesia System for Mice and Rats. Owner s Manual

Volume A Question No : 1 You can monitor your Steelhead appliance disk performance using which reports? (Select 2)

Helium Level Measurement Unit

TESLAGON. ShotHelper Manual. How to install and use the Program. Version /30/2014

Quick Start Guide. A. Hardware installation B. Software installation C. Start the software for the first time D. Do your first measurement

MULTITUBE BUBBLE TUBE BY ROMPA (U)

Figure SM1: Front panel of the multipatcher software graphic user interface (GUI) at the beginning of multipatcher operation.

Transcription:

Digi Connect ME 9210 Linux: serial port 2 for JTAG modules

Document History Date Version Change Description 08/05/2009 Initial entry/outline Table of Contents Document History... 2 Table of Contents... 2 1 Problem Description... 3 2 Requirements... 3 3 Software Setup... 3 4 Hardware Setup... 7 5 Testing... 7 Copyright 2009 Digi International Page 2/8

1 Problem Description The Digi Connect ME 9210 module with JTAG has only one serial line (port A of the NS9210 processer) connected. If you want to activate the second serial line on the development board P2 Serial Port 2, follow the instructions below. Click here for source files. Note: a kernel compiled for the modules with JTAG connectors, using second serial line on board, might not startup on modules without JTAG connector. 2 Requirements To try the example in this document you need: Digi Connect ME 9210 module with Linux (DC-ME-Y402-LX). Digi Embedded Linux (DEL) 5.0 or above development environment. For DEL 5.0 you need to have installed the latest patches via the package manager. With DEL 5.1 it should work out of the box. The Digi Connect ME development board. You can get everything together in a Digi Connect ME 9210 Linux JumpStart Kit: DC-ME-9210-LX 3 Software Setup Install Digi Embedded Linux (DEL) 5.0 or higher, apply latest patches with the Package Manager. Create a new Digi EL Kernel/Rootfs/U-Boot Project for Platform Digi Connect ME 9210, but select only Kernel as project components: Copyright 2009 Digi International Page 3/8

Configure the project (right click on the project an select configure) Copyright 2009 Digi International Page 4/8

Select Linux Kernel Configuration, Type->NS9xxx Implementations->Digi Connect ME 9210 on Devboard->Serial Port C (CONFIG_CME9210JS_SERIAL_PORTC): Select Digi Connect ME 9210 on Devboard in the Linux Kernel Configuration System Type. Enable Serial port A with RX/TX only (CONFIG_CME9210JS_SERIAL_PORTA_RXTX): Copyright 2009 Digi International Page 5/8

Select Device Drivers, Character devices, Serial drivers, Digi NS921x serial port support, Console on Digi NS921x serial (CONFIG_SERIAL_NS921X_CONSOLE): Build and install the project Copyright 2009 Digi International Page 6/8

4 Hardware Setup Digi Customizing Platform Code In Digi Embedded Linux Turn off the development board. Connect the power cable. Plug Connect ME 9210 module to the development board. Connect Ethernet cable to Connect ME 9210 to your development PC (for updating firmware). Connect a serial null modem cable (pins 2 and 3 crossed) to your host computer (e.g. COMA is the CONSOLE). Plug the cable into Serial Port A of the Digi development board. Connect a serial null modem cable (pins 2 and 3 crossed) to your host computer (e.g. COMB is the serial Port 2). Plug the cable into Serial Port B of the Digi development board. Set the devboard SW3 dip switches to any hardware handshake you have enabled in the kernel config 5 Testing Run the new build kernel on the Digi Connect ME 9210 module (e.g. update the image in flash build in section 3). Start a terminal program with 38400 8N1 on your development host on COM1 (console) and COM2 (serial port 2). Boot Linux on the Digi Connect ME 9210 module. On the serial console (COM1), configure the serial interface: # stty -F /dev/ttyns2 38400 Send some test string from the ConnectME 9210 serial port A (console) to the development host (COM2 serial port B): # echo Hello World >/dev/ttyns2 Check if the test string is received by your terminal program on COM2. Send some test string from the development host via the serial port 2 to the Digi Connect ME 9210. First start a program on the Connect ME 9210 which is able to receive the chars, e.g.: # cat /dev/ttyns2 Enter some string on the COM2 serial port 2 terminal program of your development host (press Enter, if everything is configured in line mode which is the default) and check if it is received on the Connect ME 9210 console. Copyright 2009 Digi International Page 7/8

Copyright 2009 Digi International Page 8/8