Name of product: Gripper for vertical façade FTV panels Types: PVF (60, 80, 100, 120, 133, 150, 172, 200 and 240 mm) INSTRUCTIONS FOR USE

Similar documents
Name of product: Gripper of FTV panels for horizontal façades Types: PHF (60, 80, 100, 120, 133, 150, 172,200, 240) INSTRUCTIONS FOR USE

Instructions for Use Wire Rope Hoist SAT 08 / SAT 16 / SAT 32

Overspeed governors (113 OG Моment 250 MR, 114 OG Moment 250 A3, 115 OG Moment 250 MRL, 119 OG Moment 250 MRL/1)

Triple Tine Mechanical Grapple

Z5160 Load adapter Mounting instructions (1.2 EN)

Hand winch MANIBOX GR

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures

PF30 Inspection & Maintenance Manual

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

MANUAL SEALLESS STEEL STRAPPING TOOL MODEL A

BRAKE WINCH RUP 503-[T/BT] EQUIPMENT FOR LIFTING LOADS. AT 053-[T/BT] xx

600 / 600FC OWNER'S MANUAL

3 Post Pressure Fit System Owner s Manual

RESCUE LIFTING DEVICE RUP 503-[...] AT 053-[...] xx

Floor Mount Socket. T: +44 (0) F: +44 (0)

Installation, Operating and Maintenance Instructions. V914 Cast Iron Flanged Swing Check Valve V914

Operators & Maintenance Manual OPERATOR S MANUAL USAGE AND MAINTENANCE F100M F100M. Powered Fixed Hoist Ideal for raised swimming pools and hot tubs

602 STRINGING MACHINE OWNER'S MANUAL

OPERATING and MAINTENANCE INSTRUCTIONS MAXIS 3K Puller (M3K-M)

Horizontal Bladder Tanks

RULES FOR SAFE FIRING:

Model MTB-ASME Vertical Bladder Tanks

UE- 90- X X X X X X O P E R AT I N G M A N UA L 0 TO 90 HYDRAULIC UPENDER

Model MTB-ASME Horizontal Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks

Rescue Slider - RS02. User & Installation Manual

Table of Contents Documentation for PIT TROLLEY A4

Manual winch MANISTOR 100 and 200

INSTRUCTION MANUAL Pressure Relief Device LPT

LIFTING RIG Multi-Product Installation Rig

Peak Pressure Indicator MSI-3

S-60-TO : 1 ton tower system INSTRUCTION MANUAL

Operation Manual. Hand tool for AMP DUOPLUG Customer Manual PN: en (Translation of the original German version)

310 SERIES TILT-TO-LOAD ROTATOR. The Specialist In Drum Handling Equipment

Hand pump type CH. Product documentation. 300 bar 8.3 cm 3 /stroke. Operating pressure p max : Displacement volume V max stroke :

Operating Instructions - Rescue Equipment. RAM Support LRS-T EN Edition (translation of the original operating instructions)

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Vertical Bladder Tanks

60 farm jack. Distributed exclusively by Harbor Freight Tools Mission Oaks Blvd., Camarillo, CA 93011

Operating Instructions

2000 lb manual winch

Vertical and Horizontal Bladder Tanks

Ground Release Shackle

Lifting Beam. Introduction. Important Notes. Key Benefits. User Guide

PRODUCT CARD WALL MOUNTED SIDE FOLDED BASKETBALL CONSTRUCTION PROJECTION: FROM 1,2 TO 2,45 M

OPERATION AND INSTRUCTION MANUAL Flat Roof Anchor Model: FRA250L-10X-CTS

e.do Gripper Safety requirements, technical features and assembly and integration instructions

LOAD CHARTS RT890E METRIC DIN / ISO / 75%

A N C H O R T A B S N O R T H W E S T ANCHOR TAB VF. Patented. User Instructions

PENCOFLEX COUPLING ASSEMBLY AND MAINTENANCE

LIFTING PIN VDI3366. Item code: B Use and maintenance manual complete of EC conformity declaration. San Maurizio C.

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

Pressure Fit System - Two Post Version Owner s Manual

OPERATING and MAINTENANCE INSTRUCTIONS MAXIS 6K Puller (M6K-M)

Assembly, Installation and operating. instructions for. Söll-Xenon anchorage device

Operation Manual. Nano-MQS Hand Tool 0,13-0,35 mm². en (Translation of the original German version) 1/17

Dual Release Walkers 6291 Series. 1 General. 1.1 Symbols WARNING

PRODUCT CARD WALL MOUNTED FIXED BASKETBALL CONSTRUCTION PROJECTION: FROM 1,00 TO 2,25 M

MODEL SWH10 1,000 LB CAPACITY SWIVEL HOIST

M S I C R A N E S C A L E

889P & 889P/B Backboard

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

ROLLGLISS TOP/R350. Safety and rescue system. Operating and Maintenance Instructions

Installation. Use. Maintenance INSTRUCTIONS. Care

BC Shackle. Made in the China. Alloy Steel Anchor Shackle. Instructions for handling and use - Please read in full before using this device

Instruction Manual BA90 Precision Barometer

20 Ton SD Shop Press Operating Instructions

LOAD-BEARING SHEETS SAFETY ANCHOR SA

trigger trigger guard

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

User Instruction Manual

3-PIECE BALL VALVE, 3600 PSI/ PN 248, WITH ISO DIRECT MOUNTING PAD 306M SERIES/ PED Category II

Cutting device S-16. Operating Instructions Habasit AG Postfach, CH-4153 Reinach-Basel Phone Fax


Pressure maintenance valve SDV-P / SDV-P-E

Install Manual October 2011

P+P Retractable Type Fall Arrester PK6S

Target disk flowmeter Series DP. Instructions manual DP65 DP500. R-MI-DP Rev.: 4 English version

30T A/Manual Hydraulic Shop Press

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

STAGE, STADIUM & X-TREME SHOT.

INTERNATIONAL RS:ONE CLASS RULES

OPERATOR'S & PARTS MANUAL

FLOW CONDITIONER «EMIS-VEKTA 1200» EMIS-VEKTA 1200.UM.PS v User manual Passport. «EMIS», CJSC Russia, Chelyabinsk

OPERATION AND INSTRUCTION MANUAL Swivel Anchor Model: SWY100N

INTERNATIONAL NACRA F20 CARBON CLASS RULES

BVM CORPORATION TYPE AAX TONG 55,000 FT/LBS. TORQUE Part number: Serial Number:

Installation instructions for the Yepp Maxi Easyfit

OPERATOR S MANUAL SPREADER. CSS, VNQ [For Combine Harvester AW82V] Original instructions

USE AND MAINTENANCE LIGHT TOWER

OPERATING INSTRUCTIONS (Translation) Rope winch Type KWE 250 KWV 300 KWE 650 KWV 650 KWE 1000 KWV 1250

Instruction Manual. Alfa Laval SB Pressure Exhaust Valve ESE02965-EN Original manual

INTERNATIONAL TECHNO 293 CLASS RULES

PHIGIT CLASS RULES 2006 V1.2

Operating manual Mobile Man Anchor IM-200 Reference No. IM 200

STEEL TRENCH SHIELDS DW MODELS

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

BGA158 Series CE Approved Class A Shutoff Gas Valve

Hydraulic Punch Drivers

Transcription:

Name of product: Gripper for vertical façade FTV panels Types: PVF (60, 80, 100, 120, 133, 150, 172, 200 and 240 mm) INSTRUCTIONS FOR USE

CONTENTS INTRODUCTION - GENERAL INFORMATION 3 Purpose of instructions 3 Gripper producer 3 Identification of gripper 4 FTV panels - gripper markings for vertical façades 5 DESCRIPTION OF GRIPPER 6 Components of the gripper 6 SAFETY PROTOCOL 7 Safety symbols and warnings 7 Safety mechanisms 7 TRANSPORT AND STORING 7 USE 7 User obligations 7 Loading of the gripper 8 Mounting of gripper 9 Gripper affixation for vertical assembly of panels 10 Panel lifting 11 Unfastening the grippers 12 MAINTENANCE 12 Useful life of a gripper 12 Control page 12 RECORD OF GRIPPER USE 13 DECLARATION OF CONFORMITY 14 2

INTRODUCTION - GENERAL INFORMATION Purpose of instructions These instructions are written by the manufacturer and should always accompany the gripper working device. The information herein given is intended for professionally qualified persons. These instructions for gripper usage clearly define the purpose of the gripper and contain all the information necessary to ensure their safe and proper use. For ease of reading these instructions are divided into several sections; to quickly find an appropriate section use of the index is recommended. Individual notes or warnings are written in bold print and marked by symbols! Their meanings are described below: The instructions should be strictly followed. Disregarding these instructions might result in injuries or even death. warning Warning about a dangerous situation that might arise during the useful life of the product and might represent a potential danger for personnel, property or financial loss... Important information Useful advice related to use of the gripper device. Gripper producer: TRIMO d.o.o., Prijateljeva cesta 12, 8210 Trebnje, Slovenia. 3

Identification of gripper The basic data about your gripper device is marked on the identification plate fixed on the gripper casing. The following data is stated on it: - Producer, -Type of device, -Load-bearing capacity (max. loading permitted), -Serial number, -Year of production. For panels thickness up to 240 mm: type: PVF Allowed load: 710 kg Serial number: Year and month: 20 / Interpretation of data stated on the gripper identification plate: - Type PVF: PVF - vertical façade gripper; gripper width is stated on the line. - Panel thickness types are: 60, 80, 100, 120, 133, 150, 172, 200 and 240 millimetres. - The maximum allowed load for the heaviest panels that can be lifted by a gripper is stated. - Serial number: the gripper identification sequential number is stated, e.g.: 001, 002, 003, etc. - Year and month of production 20 / : The year of production is stated first and the month of production is stated second; example: gripper produced in August in the year 2002, is marked as: 2002/08. 4

FTV panels - gripper markings for vertical façades Table 1: Markings of gripper indicating panel thickness FTV panel (mm) Marking (type) of gripper Gripper weight (kg) 1 60 PVF - 60 7,7 2 80 PVF - 80 8,1 3 100 PVF - 100 8,5 4 120 PVF - 120 9,6 5 133 PVF - 133 10,0 6 150 PVF - 150 10,3 7 172 PVF - 172 11,5 8 200 PVF - 200 12,6 9 240 PVF - 240 14,1 5

DESCRIPTION OF GRIPPER The gripper is exclusively used as an auxiliary tool for vertical assembly of Trimoterm FTV panels. The use of the gripper for all other purposes is strictly prohibited. All load-bearing elements are made of the material S355. Each panel, depending upon its nominal thickness, has its own grippers, which differ only by their width. The gripping system is the same for all thicknesses. For handling and safe transport of units the most difficult is the FTV panel 240. All calculations and tests are carried out for each of the grippers for these types of panels. A gripper can be used for lifting panels with a sheet metal thickness 0.5/0.5 mm to 0.8/0.8 mm, and wool density up to 120 kg/m 3. Components of the gripper for panels of thickness 60, 80, 100, 120, 133, 150, 172, 200 and 240 mm Figure 1: Components of the gripper Pos. 1 - Frame of the gripper Pos. 2 - Fastener Pos. 3 - Guard Pos. 4 - Fastener for the gripper Pos. 5 - Sealing tape (IDENT 5012487) or coating of rubber 6

SAFETY PROTOCOL Safety symbols and warnings Various symbols, whose meanings are explained in the introduction, are used for warning of dangerous situations and advising on correct gripper use. It is vitally important to follow these instructions and advice to ensure safe work with the grippers. Safety mechanisms Human factor The gripper is a mechanical device without any rotating parts. The use of the latch prevents accidental usage. Grippers produced for a particular purpose should only be used for the assembly (see panel type and type of gripper in table No. 1). Lifting should not begin until the device is correctly placed on the panel. System of panel gripping Panel gripping is provided mechanically by the fastener for the gripper. TRANSPORT AND STORING Grippers should be transported individually and manually, one in each hand. Special attention should be paid during carrying since the device should not be dropped or should not damage the feet and/or other parts of the body. When carrying and transporting three or more grippers these are transported in a case or any other packaging. Grippers should not get physically damaged during transport. When storing them, grippers should be protected against weather conditions and mechanical damage. USE warning Before use the gripper should be visually checked. If any mechanical defects are visible, the device should be eliminated from the working process. Any repair or replacement of damaged parts of the device is strictly prohibited. User obligations - The gripper can be used only for the purpose for which the gripper has been produced. - The use of the gripper is allowed only in compliance with the instructions of the producer. - Users of grippers should keep records about their use (records are in the appendix to these instructions). - Personnel are not allowed to stand under the panel when it is being transferred by the PVF grippers. 7

Loading of the gripper One gripper PHF can take a maximum load of 710 kg. Table 2: Weight of panels regarding length and type (steel sheet 0.5/0.5 mm, MW 120 kg/m 3, width 1000 mm) Length FTV 60 FTV 80 FTV 100 FTV 120 FTV 133 FTV 150 FTV 172 FTV 200 FTV 240 2 m 31.5 36.3 42.1 45.9 49.1 53.1 58.5 65.1 74.7 4 m 62.9 72.5 82.1 91.7 98.1 106.1 116.9 130.1 149.3 6 m 94.4 108.8 123.2 137.6 147.2 159.2 175.4 195.2 224.0 8 m 125.8 145.0 164.2 183.4 196.2 212.2 233.8 260.2 298.6 10 m 157.3 181.3 205.3 229.3 245.3 265.3 292.3 325.3 373.3 12 m 188.8 217.6 246.4 275.2 294.4 318.4 350.8 390.4 448.0 14 m 220.2 253.8 287.4 321.0 343.4 371.4 409.2 455.4 522.6 Note: Panel weights stated above are in kg. Table 3: Weight of panels regarding length and type (steel sheet 0.8/0.8 mm, MW 120 kg/m 3, width 1000 mm) Length FTV 60 FTV 80 FTV 100 FTV 120 FTV 133 FTV 150 FTV 172 FTV 200 FTV 240 2 m 49.1 54.8 60.6 66.3 70.2 75.0 81.5 89.4 100.9 4 m 98.1 109.6 121.2 132.7 140.4 150.0 162.9 178.8 201.8 6 m 147.2 164.4 181.7 199.0 210.5 224.9 244.4 268.1 302.7 8 m 196.2 219.3 242.3 265.3 280.7 300.0 325.8 357.5 403.6 10 m 245.3 274.1 302.9 331.7 350.9 374.9 407.3 446.9 504.5 12 m 294.3 328.9 363.5 398.0 421.1 449.9 488.7 536.3 605.4 14 m 393.4 383.7 424.0 464.4 491.2 524.8 570.2 625.6 706.3 Note: Panel weights stated above are in kg. Table 4: Weight of individual panel type per m 2 with steel sheet 0.6/0.6 mm and MW 120 kg/m 3 FTV 60 80 100 120 133 150 172 200 240 Weight (kg/m 2 ) 17.3 19.7 22.1 24.5 26.1 28.1 30.8 34.1 38.9 8

Table 5: Weight of individual panel type per m 2 with steel sheet 0.7/0.7 mm and MW 120 kg/m 3 FTV 60 80 100 120 133 150 172 200 240 Weight (kg/m 2 ) 18.9 21.3 23.7 26.1 27.7 29.7 32.4 35.7 40.5 Table 6: Weight of individual panel type per m 2 with steel sheet 0.8/0.8 mm and MW 120 kg/m 3 FTV 60 80 100 120 133 150 172 200 240 Weight (kg/m 2 ) 20.4 22.8 25.2 27.6 29.2 31.2 33.9 37.2 42.9 Check element weight before using the grippers. Mounting of gripper The use of a gripper is allowed for panel length up to 14 metres. Grippers must be affixed in such a way that the gravity axis of the panel passes through the gripper fastener as shown in Figure 2. Figure 2: The position of the gripper 9

Gripper affixation for vertical assembly of panels Prior to affixing the gripper it is necessary to place polystyrene foam under the panel and move the panel 200 mm in order to drill holes in it. It is necessary to drill three φ 14 holes for 60, 80 and 100 FTV panels (Figure 2). Panel thicknesses of 120, 133, 150, 172, 200 and 240 mm demand three φ 18 holes. The centre of the hole must be at least 35 mm away from the edge of the panel. Before drilling, place the gripper onto the panel so that the edge of the panel rests against the bottom of the gripper. After drilling, place the gripper so that it rests against the top of the panel and connect the panel to the gripper with the help of the fastener (Fig. 3). Before fastening, the lever should be in a horizontal position; and after fastening, the lever should be in a vertical position. Before lifting the panel with the gripper all three fasteners need to be properly affixed. Figure 3: Affixing the gripper Guard Gripper Fastener Panel warning Lifting without a properly affixed fastener is prohibited (Figure 4)! Figure 4: Improper affixation of the gripper 10

Panel lifting During lifting it is necessary to hold the bottom part of the plate by the polystyrene foam so that the panel does not slip onto the adjacent panel. Lifting should be even and without blows or knocks, and care should be taken to prevent damage when lifting the panels (Figure 5). Figure 5: Lifting of a panel gripper polystyrene foam Standard parts are used (steel wire cables, shackles) as connecting parts between the hoisting equipment (lift) and the gripper, and these connecting parts must comply with the appropriate standards (in dimensions, fastening systems). These connecting parts are not described in these instructions and are not an integral part of the gripper system. It is recommended to use a shackle as a connecting element between the gripper and the steel wire cable. warning Use protective gloves when using the gripper. Do not wear loose clothing when lifting using a gripper. After the grippers have been mounted and before the beginning of lifting all persons should move away and back - a safe distance should be kept danger of panel swinging, function defect. 11

Always use protective gloves when using the gripper. All potential problems and dangers should be evident at the initial stage of lifting when part of the panel is still on the ground. Unfastening the grippers Unfastening of grippers is performed in the opposite sequence to fastening. The gripper is fixed with a load-bearing cable during the complete procedure. MAINTENANCE The gripper should be protected against external (weather and mechanical) influences. The gripper that gets scraped very badly during use should be protected against corrosion. Before each use the gripper should be visually checked. If any deformations of the load-bearing elements (safety pin, latches, cover, holder) are observed they should be measured. If they exceed 1 mm, the gripper should be eliminated from use. Useful life of a gripper When the gripper has lifted 10,000 m 2 of FTV panels, or after one year of use, the gripper should be eliminated from use (records of gripper use). During daily inspection if it is noticed that individual parts are worn or bending by more than 10% from their normal state, the gripper should be eliminated from use. Control page Period of checking Type of activity Type of check Method of checking Person checking Note Daily Cleaning, Anticorrosion protection Complete device Visual Operator - Connecting person See MAINTENANCE Half-yearly Cleaning, Anticorrosion protection Complete device Visual, anticorrosion protection if required Operator - Connecting person See MAINTENANCE 12

RECORD OF GRIPPER USE (THIS RECORD MUST BE COMPLETED AFTER EACH USE) Type of gripper: Serial number: Month and year of production: No. Date of use Location Project Country Quantity From To of built in FTV panels (m 2 ) Accepted by (Name and Surname) 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. Note: LOLER expires after 6 months from date of issue of certificate. Notes 13

Appendix No. 2: DECLARATION OF CONFORMITY In accordance with the Machinery Safety Rules, the Official Gazette of the Republic of Slovenia, no. 75/2008, 66/2010 TRIMO d.o.o. Prijateljeva cesta 12, 8210 Trebnje, Slovenia declares with ultimate responsibility that THE GRIPPER OF FTV PANELS FOR VERTICAL FAÇADES PVF Type: PVF (60, 80, 100, 120, 133, 150, 172, 200 and 240 mm) Year of manufacture: 2013 is produced according to the requirements of the following regulations: - Machinery Safety Rules, the Official Gazette of the Republic of Slovenia, no. 75/2008, 66/2010 (MD 2006/42/EC), - SIST EN ISO 12100:2011, - SIST DIN 15018-1:1996; SIST EN 13155:2004+A2:2009; SIST EN 1993 NOTE: The gripper for FTV vertical facades is intended for lifting and carrying panels with a thickness of 60, 80, 100, 120, 133, 150, 172, 200 and 240 mm. Date and place: Trebnje, 01.06.2013 Signature of authorized person: Danijel Zupančič, MA Deputy General Manager for the Technical Sector 14

NOTE

TRIMO D.O.O. PRIJATELJEVA CESTA 12, 8210 TREBNJE, SLOVENIA T: +386 (0)7 34 60 200 F: +386 (0)7 34 44 125 TRIMO@TRIMO-GROUP.COM WWW.TRIMO-GROUP.COM Published by: Trimo d.o.o. 02/2017 Trimo Group holds full copyrights on the information and details provided on this media, therefore any unauthorized reproduction and distribution is strictly prohibited. Professional care has been taken to ensure that information/details are accurate, correct and completed and not misleading, however Trimo, including its subsidiaries, does not accept responsibility or liability for errors or information, which is found to be misleading. Information/details on this media are for general purposes only. Use of it is on your own initiative and responsibility for compliance with local laws. Any deviations in details and project solutions are user responsibility. In no event, will we be liable for any loss or damage including without limitation, indirect or consequential loss or damage, or any loss or damage whatsoever arising from loss profits arising out of or in connection with, the use of this media. All information issued by Trimo Group is subject to continuous development and information/details contained on this media are current at date of issue. It is user`s responsibility to obtain most up-to-date information from Trimo when information/details are used for project. The last version of the document is available on www.trimo-group.com. Latest version of published document in English language prevails over other translated language documents. For information about the delivery of panels see Trimo s General conditions (https://trimo-group.com/en/trimo/general-conditions-of-sale).