Our most comfortable and intelligent Non Contact Tonometer ever

Similar documents
628 Differential Pressure Decay Leak Tester

Keeler Digital Applanation Tonometer (D-KAT)

DFX II Series. Digital Force Gauge

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

We measure it. For gas and water installers. testo hpa. bar

Battery Powered Thermal Mass Flow Meters for Gases

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Series 7250 Ruska High-Speed Digital Pressure Controller. GE Sensing. Features

Selecting the right pressure sensor for your application

Blood Parameter Monitoring System 550

Diagnostics in the instrumentation More than just equipment monitoring

ON736 Series: Oxygen/Nitrogen by Inert Gas Fusion

Pneumatic high-pressure controller Model CPC7000

MACH ONE MASS FLOW CONTROLLER. MACH ONE SERIES flow control. MASS FLOW CONTROLLERS at the speed of sound.

Fabius Tiro TM. Designed for your environment. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Narkomed MRI-2. A perfect fit for the MRI environment. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

OptonPro. High-power laser up to 7000 mw. Laser therapy natural healing with the power of light

P3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features

Four common PRESSURE CALIBRATION PAIN POINTS

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

Neles ValvGuard VG9000H Rev 2.0. Safety Manual

6200 Automatic Isoperibol Calorimeter Calorimeter with 1108 Oxygen Bomb, Bucket and 1757 Printer

HUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0

L-708 / L-708LD Bore Alignment System

Fabius Tiro TM. Designed for your environment. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

WindProspector TM Lockheed Martin Corporation

red-y compact series product information Battery Powered Thermal Mass Flow Meters for Gases

ONH836 Series: Oxygen/Nitrogen/Hydrogen by Inert Gas Fusion

P3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features

Focused on essentials DRÄGER SAVINA 300

SpeedMax White Paper. Dynastream Innovations Inc. 228 River Avenue Cochrane, AB T4C 2C1. p f

Pneumatic Outflow Control

Improve Process Reliability

Optical Dissolved Oxygen Meter

Fail Operational Controls for an Independent Metering Valve

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

ekom Compressor for Medical Air Sonata with Ekom

HumiSys HF High Flow RH Generator

Windar Photonics Wind Sensor. Great at Control

Homecare Pneumology NEONATOLOGY ANAESTHESIA INTENSIVE CARE VENTILATION Step beyond the future

KGW - ISOTHERM. Operating Instructions. Level controlling device for liquid nitrogen LEVEL CONTROL LN2

OUS31. Technical Information

New Generation System M, leading the World in the Non-Invasive Measurement of Critical Real-Time Parameters.

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

The benefits of the extended diagnostics feature. Compact, well-proven, and flexible

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

Easy with a modular concept for future expansion

Series Ruska Digital Pressure Indicator. GE Sensing & Inspection Technologies. Features

Entry to the premium class!

Design of an Automated Perfusion Pump James J Higham

The Future of Hydraulic Control in Water-Systems

Hydraulic comparison test pump Models CPP1000-X, CPP1600-X

Over 80 years of experience in precision weighing and UniBloc technology

COMPARISON OF DIFFERENTIAL PRESSURE SENSING TECHNOLOGIES IN HOSPITAL ISOLATION ROOMS AND OTHER CRITICAL ENVIRONMENT APPLICATIONS

Microscopy Cryogenic WORKSTATION. Performance by Design

h2000 plus HyDROGEN LEAk DETECTOR

Fail operational controls for an independent metering valve

PositionMaster EDP300 Extended Diagnostics. Compact, well-proven, and flexible

VIAFLO 96. Electronic 96 Channel Hand Held Pipettor

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

c) Loss of product or replacement when units are being serviced All of these are factors that need to be considered by the user.

Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L

Pneumator. Testo Industrial Services More assurance, better service. Pressure calibrator and measuring instrument.

U S ER S AN D M AI N TEN AN CE M AN U AL

KMT Waterjet Systems Inc.

Focused on essentials DRÄGER SAVINA 300

The following gives a brief overview of the characteristics of the most commonly used devices.

HUMOR 20 HUMOR 20. High-precision Humidity Calibrator. Water T, p1

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

brands you trust. DEPA DH Next Generation Air Operated Double Diaphragm Pumps

Micro Motion 3098 Gas Specific Gravity Meter

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in:

7250 Sys. Ruska Multi-Range Pressure Calibration System. GE Sensing & Inspection Technologies. Features. Applications

T EK-COR 1100A. Coriolis Mass Flowmeter. FLOW. Technology Solutions

Convergent Technologys product overview

What is LPG? Released Energy in the narrowest area. Clean and sure in the practise

Specifications...Easy CLIA Classification: Sample Type: Blood gas analyzer operation has never been simpler Sample Size: Measured Parameters PCO2

Optical Dissolved Oxygen Meter

SCAM T.P.E. WATER TREATMENT SYSTEM SWT- AP AUTOMATIC PURGE

COSMO INSTRUMENTS CO., LTD.

Setting a New Standard in Flash Chromatography Performance

Oxylog 2000 plus. Step up your performance. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Protec P3000 (XL) Helium Sniffer Leak Detector

HOW WISE TECHNOLOGY WORKS INFICON Protec P3000 sensor powered by Wise Technology, consists of an evacuated gas cell covered by a quartz membrane.

AirElite 4h KO₂ closed circuit breathing apparatus

CSO/STORMWATER MANAGEMENT. HYDROVEX HHV-E Vortex Driven Regulator

Datasheet: K-30 ASCII Sensor

Deadweight Tester / Pressure Balance High pressure up to 5,000 bar / 70,000 psi CPB5000-HP. Applications. Special features. Description. Rel.

Did you know that new clean air regulations are now mandatory for all practices?

UniBloc technology and over 80 years of experience in precision weighing. Registered

How to specify a product. Process Sensors and Mechanical Instruments

Air Plus User Manual

Assembling and testing fluid power systems

Mass Flow Controllers

Pressure independent control valve (PICV) FLOWMATIC

Hydraulic Valve Installation Guide

Unisys. Imagine it. Done. c Consulting. c Systems Integration. c Outsourcing. c Infrastructure. c Server Technology. Unisys NDP 30 and NDP 110

The Ins and Outs of I/P Transducers

Micro Motion 7812 Fiscal Gas Density Meter

Transcription:

Our most comfortable and intelligent Non Contact Tonometer ever

the intelligence inside intellipuff - the Keeler intelligent puff system giving you a quantum leap forwards in accuracy and ease of use. intellipuff embodies electronic and optical technology to deliver you the speed, accuracy and ease of use you and your patients deserve. Accuracy guaranteed. Ease of use intellipuff automatically senses when there is difficulty perhaps a dry eye or a damaged cornea and adjusts the automatic firing criteria accordingly simple. Keeler s unique algorithm will constantly evaluate your readings and ensure the tightest range is used to give you the final and perfect result every time. When the intelligent system considers you have enough reliable readings for an eye, the sound system will let you know no more guesswork and the minimum puffs per patient.

Our softest puff ever Gentle is understating the new system and if the patient has high pressures the puff will automatically increase for the next measurement. Kind, intelligent and simple. Technology working for you. Engineered to perfection this 5th generation device is better than ever there are no limits. This is the most accurate, smallest, quietest, lightest, fastest Pulsair ever. No more bulbs to change our new LED (Light Emitting Diode) illuminated targeting system will last a lifetime and never need changing. Cooler, 100% reliable, 100% consistent. Cost effective no sterile consumables to purchase, and printing is optional, so your ownership costs are insignificant. Time on target system easier to use Algorithm to ensure best readings greater accuracy Sounds to inform of the status of data gathered greater confidence Lighter puff soft and gentle for your patients

More information, more control intellipuff displays the rolling average of your readings the more data you have the better the result delivered. Outlying readings are automatically excluded by our algorithms. User control allows you to select your preferred user options, printing, sound notifications, display cha aracteristics. intellipuff will self check the system and tell you all is well, confidence inspired. You can choose how your intellipuff is configured Name: Date: Time: Right Eye: Avg IOP: 10.4 mmhg Data: (20), 10, 10, 10 Left Eye: Avg IOP: 10.5 mmhg Data: 10, 11, 10, 10

Hand-held and Non Contact Save time, increase flexibility. Conventional chinrest devices take time to get the patient aligned and comfortable just consider the total time wasted over a 12 month period adjusting table and chinrest heights and settling your patients. Time is our most precious commodity. Pulsair intellipuff gives you more time Add to this time saving the flexibility to measure IOP s on patients that are unsuitable for a chinrest device those with disabilities, children, the elderly or infirm. Save time and cost. Pulsair intellipuff does not touch the eye and hence virtually eliminates any possibility of cross infection. Pulsair intellipuff requires no anaesthetic or fluorescein, has no need for any disinfection or sterilisation regime and requires no single use consumables. Usage costs virtually nil. Objective Tonometry The Pulsair intellipuff will only fire when perfect alignment and patient position have been achieved, thus removing all subjectivity from the measured result. Tonometry you can trust. No need to get the patient to a chinrest any patient, anywhere, supine or sitting it makes no difference total versatility For additional stability and to ensure the perfect conditions are met every time use the new pop out forehead stabiliser

Desk top or wall mount Space saving flexibility - Save valuable space Pulsair intellipuff uses less than 50% of the space of conventional non contact tonometers and is the only model that can be wall mounted. intellipuff is the only model that can be wall mounted! Whether you wall mount or prefer to place it on you desk you win the space war every time. No special instrument table is required put it where you want it. Move it when you want to. Total flexibility.

Technical Information Keeler Pulsair intellipuff subsystems Air impulse tonometry is an extremely complex process. Reliable, repeatable and accurate objective tonometry relies upon the performance of two critical subsystems: Position detection It is important that the instrument knows its position and orientation relative to the eye being measured. When an air packet is released towards the cornea, the release position and the direction of the air travel have significant effect on the reaction of the cornea to the puff and therefore the measurement result. This position detection in the case of a hand-held instrument in which neither the patient s eye nor the operator s movements are restricted becomes of critical importance. In the latest Keeler instrument this is carried out through the use of 3 optical sensors working at infra-red wavelength. A continuously monitored and controlled LED infra red light source provides a precisely directed beam whose reflection from cornea is registered by the 3 sensors. These sensors provide the critical alignment data related to the distance, pitch and the alignment of the instrument from the cornea. The signals are converted to digital form at rates of up to 100K bytes per second. It is the intelligent processing of these signals which enable the on-board processor to calculate precisely the instruments position relative to the patient s eye every fraction of a millisecond thus allowing an event (air release) only when alignment is perfect. The quantized air puff Here, our instrument design departs from the more conventional motor/rotary-actuator driven piston for generation of the air puff. In a handheld instrument it is of paramount importance that the measurement is carried out in the shortest possible time, reducing the possibility of hand/eye movement which can lead to errors in the measurement. Following extensive research at Keeler, we have perfected a pressurised plenum chamber and solenoid-valve technique which enables the instrument to perform its measurement within a maximum period of 10ms of data capture (typically 3ms). Accurate control and measurement of the reservoir pressure together with high speed measurement of each individual generated air puff and the tracking of individual solenoid valve characteristic has enabled the instrument to achieve repeatability of operation well beyond that experienced in instruments of this type in the past.

Specifications Calibration range 5mmHg to 50mmHg Measurement scale mmhg (millimetres of mercury) Displayed accuracy 0.1mmHg Display 4 character dot matrix scrolling Firing system Automatic and objective Illumination system LED infra red Working distance 20mm Mounting system Table/desktop/wall Base unit dimensions 260 x 215 x 220mm (H x D x W) Base unit weight 2.465Kg Handpiece dimensions 315 x 150 x 46mm (H x D x W) Handpiece weight 0.890Kg Umbilical cord length 2.0m Printer Thermal line printer Part Numbers: 2414-P-2001 intellipuff unit 2414-L-7008 Printer paper roll 0088 Complies with: Safety (Medical) EN 60601-1:1990 plus amendments A1:1993, A11:1993, A12:1993, A2:1995 and A13:1996. EN ISO 15004:1998, Clause 6.3 optical radiation hazard, Clause 7.3 environmental conditions. EN60601-1-2 for EMC. Keeler Limited Clewer Hill Road Windsor Berkshire SL4 4AA Freephone: 0800 521251 Tel: +44 (0) 1753 857177 Fax:+44 (0) 1753 827145 Keeler Scotland 25 Deerdykes View Westfield Estate Cumbernauld G68 9HN Freephone: 0800 521251 Tel: +44 (0) 1236 721214 Fax: +44 (0) 1236 721231 Keeler USA 456 Parkway Broomall PA 19008 USA Toll Free: 1 800 523 5620 Tel: 1 610 353 4350 Fax: 1 610 353 7814 www.intellipuff.com