SUUNTO COMBOS AND MECHANICAL INSTRUMENTS

Similar documents
SUUNTO ELEMENTUM AQUA USER GUIDE

CHEMICAL INDUCTION KIT (Pt.No Issue 6, October 2015)

RADROVER REAR RACK INSTALLATION MANUAL

TL-12 FLUSH TANK. Manual Ref. # MN-??? Polyurethane Machinery Corp. REVISION 1.0

ROPV R40 E Series User Manual

J Air and Water Kit Instructions Part# 02584

WARRANTY, QUICK START GUIDE

P5523. Users Manual. Liquid to Gas Separator. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Inflatable Stand Up Paddle Board Manual

USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician.

Please Do Not Return This Product To The Store!

4-in-1 Professional Inflator Kit

D Series Air and Water Kit Part# 02550

URC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports

INTRODUCTION BILL OF MATERIALS SPECIFICATIONS & TOOLS PROCEDURES OPERATION OF SEATPOST GIANT LIMITED WARRANTY

User Instruction Manual

Revolution Gurney Attachment

Yoke Block Instruction Manual

RG3100 and RG3100Ice Regulator System

DISASSEMBLING & REASSEMBLING CARTRIDGE INSTALLING SEATPOST ON BIKE

User Operation Manual and Safety Instructions

OWNERS MANUAL. Model Shown with optional Primary Mooring Cleats. Portable Mooring System SAFETY OPERATION MAINTENANCE PARTS

Pressure Relief Valve Instruction Manual

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

PERSONAL AIR BREATHING UNIT

Remington 700. Disclaimer Limited Warranty Satisfaction Guarantee Installation Instructions

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

SMART Oxygen Analyzer. User Manual

Yoke Block Instruction Manual

3 Scotch-Weld Polyurethane Reactive Adhesive Applicator Replacement Part Installation Guide

This document to be used with Hurley traditional Davits

Owner s Manual W Automatic Aboveground Pool Cleaner

DFB FLOW METERS (DESIGNED FOR BLENDERS, DUAL TAPER)

Cylinder Tilt Saddle Instruction Manual

WARNING NOTES TABLE OF CONTENTS

The Churchill. Chest Clip Guard

U S E R M A N U A L AIR FLOWMETER. MODELS: 1MFA2001 (shown) 1MFA9001 CAUTION. ISO Certified

Operation Manual. O2 Quickstick. Oxygen Analyzer

WELCOME SAFETY INSTRUCTIONS

Model ASSEMBLY and OPERATING INSTRUCTIONS

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

NOTES TABLE OF CONTENTS

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

FlashGARD HP Reverse Osmosis Filtration System Model Number FSTMO75 Part Number

ACRYLIC FLOW METERS 0-30, 0-70 & LPM

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

TactAir PCP Fill Kit/Adapter. Operation Manual

isup MANUAL THANK YOU FOR PURCHASING A KAHUNA isup, WE HOPE YOU HAVE MANY YEARS OF PADDLING ENJOYMENT.

Operation Manual. O2 Quickstick. Oxygen Analyzer 08.17

INSTRUCTIONS warranty watch care

HUBEN K1 Pre-charged Pneumatic Air Rifle Owner s Manual

ATD /8 x 50 Retractable Air Hose Reel Owner s Manual

PC1131 Electric Air Compressor

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

SMART Carbon Monoxide Analyzer. User Manual

PRESSURE COMPARATOR 10000PSI 700bar. Operator Instructions CRYSTAL. engineering corporation

PoolNaturally. Pure. Simple. Genius. Installation and Product Use Instructions In ground and above ground pools

RK LEL Sample Draw Aspirator Adapter Operator s Manual

3M Liqui-Cel EXF-10x28 Series Membrane Contactor

RK-IR Sample Draw Aspirator Adapter Operator s Manual

Traditional Basketball Set. Assembly & Installation Instructions

Portable Compressed CO 2 Regulator

Gemini Owner s Manual

CSA Sample Draw Aspirator Adapter Operator s Manual

Pasture Meter Auto Lift Kit 5003 (Leaflet Pt.No Issue 4, October 2015)

ADMINISTRATION GENERAL INFORMATION OCEANIC ADMINISTRATION FOR PRODUCT SERVICE PROCEDURES

WARRANTY & WATCH CARE

602 STRINGING MACHINE OWNER'S MANUAL

HoverJack. Air Patient Lift. Equipment Manual. From HoverTech International. Issued: June 1,

Lab Cock. Contents. User s Manual (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

User s Manual. USB Golf Simulator. Contents

6 digital caliper with case

Windy City II. User instruction manual WARNING: Fill pressure: 200 bar (approximately 2,900 psi)

FLANGED TWO-PIECE BALL VALVES

PARK AVENUE 7' POOL TABLE WITH TABLE TENNIS & BENCHES ASSEMBLY INSTRUCTIONS

Installation Instructions Air Compressor Part # 2780, 2781

1 waterp wa r te o rp o r f o - of us us a a..com co m Waterproof Wetsuit Manual

HMO500. Headrest Hardware. Stealth s Multi-Axis Headrest Hardware. Installation Manual INSTALLATION INSTRUCTIONS FOR. Stealth Products HMO500 Hardware

PILOT PEDAL DRIVE INSTRUCTIONS

SERVICE LETTER WARRANTY CONDITIONS FOR ROTAX

V O L L E Y B A L L S E T

Model C Pipe Line Strainer 6, 8 & 10 Inch (DN150, DN200 & DN250) 250 psi (17,2) General Description. Technical Data. Page of 6 MAY, 2006 TFP1644

O2 Portable. User Manual

INSTRUCTIONS PARTS LIST

3M Liqui-Cel EXF-10x28 Series Membrane Contactor with ANSI or JIS Connections with Integrated End Caps

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information

DRAFT U S E R M A N U A L CAUTION. Model: 19MFA1001 Series. Federal (USA) law restricts this device to sale by or on the order of a physician.

OWNER'S MANUAL. Copyright 2003 GAMMA - All Rights Reserved

2 CYLINDER MOBILE CART USER S MANUAL / INSTRUCTIONS

7 FOOT POOL TABLE WITH TABLE TENNIS TOP ASSEMBLY INSTRUCTIONS

Monster Windy City Leopard

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

Modular skylight warranty

SOTR Special Operations Tactical Respirator

RG2200 BC Integrated Octopus

Contact Chamber and PoolMoss Packs

Tactical Sniper air rifle & carbine

TR5000 THE TOUGHEST TRAINING SYSTEM ON THE PLANET. MODEL NO. STRIKER TRAINER 2L Escalade Sports

SANTA CRUZ BICYCLES Geometry Adjust Flip Chip

Transcription:

en SUUNTO COMBOS AND MECHANICAL INSTRUMENTS INSTRUCTION MANUAL Combo Consoles I Console Compasses CB-71/STD and CB-71/DS Depth Gauge SM-16 I Pressure Gauge SM-36

SUUNTO Combo Consoles Introduction The Suunto combo consoles for recreational use, allow you to create a personal combo according to your own specifi c needs. Analog gauges, dive computers and compasses fi t together like building blocks. The combos consist of four main modules: the pressure gauge module, the instrument module and two different compass modules. The pressure gauge module is designed for the Suunto pressure gauges and it can also be used with the new Suunto Quick Release (QR). The basic combinations are displayed below: 2

Assembling the Combo Modules 1 2 3 (3) 5 4 (5) 1. CB-ONE module front cover with SM-36 pressure gauge in place (see section CB-ONE Module assembly) 2. CB-IN-LINE module front cover 3. CB-end piece or CB-71/STD compass (optional) 4. CB-IN-LINE module back cover with instrument 5. CB-ONE module back cover or CB-71/DS compass (optional) 3

CB-ONE Module Assembly The CB-ONE Module is designed to fi t the Suunto SM-36 analog pressure gauges. Before assembling the CB-ONE module the hose cover needs to be fi tted on the pressure hose. The hose cover ensures that the SM-36 pressure gauge fi ts properly on the CB-ONE module. If the Suunto Quick Release is used, the hose cover is not to be used (See section CB-ONE module assembly using the SUUNTO Quick Release). After attaching the hose cover the pressure hose and gauge are assembled on the CB-ONE front cover according to the picture. After the pressure gauge is in place the CB-ONE back cover (or alternatively the CB-71/SK-7/DS compass) is attached with four screws. 4

CB-ONE Module Assembly when using the SUUNTO Quick Release If the SUUNTO Quick Release (QR) is used the hose cover should be attached on the high pressure hose below the female end of the QR. The male part is attached to the pressure gauge which is then fi tted onto the CB-ONE front cover according to the picture below. CB-IN-LINE Module Assembly The CB-IN-LINE module fi ts the Suunto Vyper and Zoop dive computers or the SM-16 round depth gauge. The Vyper locks in place on the IN-LINE module back cover. For the other instruments there are lugs on the back cover aiding the orientation. The Suunto Vyper and Zoop are delivered with a display shield. 5

SUUNTO Console Compasses CB-71/SK-7/STD and CB-71/SK-7/DS The CB-71/SK-7 is available in two versions: the CB-71/SK-7/STD for attachment on top of the combo modules or the Cobra dive computer, and the CB-71/SK-7/DS for attachment on the back side of the CB-ONE module. Compass use for divers General instructions Usually a compass must be held precisely in a horizontal position, otherwise the needle will sting. The SK-7 compass may however be inclined about ±30 degrees. Sighting a compass bearing Hold the compass so that the compass is in a horizontal position and the direction line points away from you. Turn with the compass until the direction line points at your destination, then turn the direction ring until the magnetic North needle is aligned between the slit marks. The front end of the direction line on the SK-7 shows your compass bearing, and as long as the North needle is aligned between the slit marks, the direction points toward your destination. The SK-7 compasses also have a side reading window, which also enables you to take a bearing by directing the compass towards the destination and by reading the compass bearing from the side window. This bearing can be memorized by turning the direction ring to that bearing. Setting a given bearing or direction The scale division on the SK-7 is 360 degrees clockwise from 0 degrees at North. Turn the direction ring until the front end of the direction line is at the desired direction. Turn the compass until the needle falls between the slit marks. The direction line now points in the desired direction. Magnetic declination Maps and marine charts are drawn in correlation to the geographic poles, while the magnetic compass needle is subject to magnetic declination which varies according to the location. General orientation on the diving site Before diving, check the main compass bearings at the dive site, paying special attention to memorizing the direction of the shoreline and bearings of landmarks that may be of importance. Natural aids to underwater navigation The underwater extension of the shore s inclination tells the diver if he is following the shoreline. Be careful however as underwater ridges may lead you astray. Surface occasionally to check your position. The dip and stratifi cation of rocks on the shore can often be followed over large areas under water. 6

Sand ripples usually form long lines parallel to the shore. The direction of currents should be noted by their effect on algae or drifting particles. Use the compass to check the bearing of the current. In shallow water, the sun s direction can be seen from shadows on the bottom, or by looking towards the surface. Swimming in a straight line along the bottom is greatly facilitated if you can line up three distinctive objects in your line of vision. As you reach the fi rst one, line up a new one farther away, so that you again have three points determining your course. This way you can counteract the effects of side current. Compass Balancing The horizontal and vertical components of earth s magnetic fi eld vary in different locations. For this reason Suunto compasses are balanced for 2 different zones. If the compass is used in an adjacent balancing zone the compass needle will tilt only slightly. However, the farther the compass is used from it s intended zone, the more the needle will tilt. In extreme situations the needle might stick. For this reason it is very important to know in which country the compass will be used. Compass zone map 7

SUUNTO Mechanical Gauges Suunto depth gauge SM-16 Models available: 45 m, 70 m, 150 ft, 230 ft Suunto pressure gauge SM-36 Models available: 300 bar and 4000 psi Before usage Depth gauge: Before diving, check the position of the depth indicating pointer. Atmospheric conditions (altitude, temperature) may cause the point to not indicate zero. If this is the case, turn the adjusting screw located at the right side of the gauge to align the pointer to zero. The adjustment is to be made at the temperature of usage. Repeated unnecessary adjustments may cause excessive wear to the seals and eventual leakage. CAUTION! Do not attempt to adjust the water entry port located at the left side of gauge. Tampering with the port can cause damage to internal components. Do not pressure test gauge in air. Always immerse the gauge in water while pressure testing it. Pressure gauge: The hose has an end fi tting with 7/16 20 UNF-thread. If your regulator has a different thread size in the high pressure (HPoutput) port, ask your dealer for the correct adapter. Always inspect the o-ring at the male thread to be sure it is clean and undamaged before connecting it to the regulator. Always turn your air supply on slowly. Always turn the pressure gauge dial face away from your face when turning on the air supply. Do not overtighten the hose at the gauge, the fi tting is pressure proof even when tightened with fi ngers. Service Avoid subjecting the gauges to excessive shock loads such as those that might occur from being dropped or hit against an 8

immovable object. Do not subject the gauges to pressures beyond their maximum range. Temperature extremes can be damaging. In general, the gauges should not be exposed to temperatures to which you would not expose yourself. CAUTION! After use, rinse the gauges or the console with fresh water and store them out of direct sunlight, in a dry place at room temperature. CAUTION! Do not attempt to clean the gauges with anything other than water. Use of cleaning agents or compressed air can cause permanent damage. The introduction of any probe into the water entry port of the depth gauge or the pressure relief valve opening of the pressure gauge can also damage internal components. Before prolonged storage the instruments should be removed from the console, rinsed with fresh water and stored separately. CAUTION! Do not attempt to disassemble the gauges. Special tools and training are required to perform the adequate service. The instruments must be serviced by an authorized dealer every second year or after 200 dives (whichever comes fi rst). 9

Operating and Storage Temperatures SM-16 Operating temperature 0 C to 40 C [32 F to 104 F] Storage temperature -20 C to 50 C [-4 F to 122 F] SM-36 Operating and storage temperature 0 C to 40 C [32 F to 104 F] Technical Specifications The Suunto depth gauge SM-16 complies with the pren 13319 standard. The tolerances for depth gauges are: At 3m +0.8 / -0.4 m At 6m +0.8 / -0.4 m At 9m ±0.8 m At 15m +1/ -1.2 m At 30m +1/ -1.2 m At 45m +1/ -1.5 m At 60m +1 / -1.5 m The SM-36 pressure gauges comply with the EN 250 standard. The tolerances for pressure gauges, measured at decreasing pressure are: At 40 bar ± 5 bar At 100 bar ± 10 bar At 200 bar ± 10 bar At 300 bar ± 10 bar 10

Suunto Limited Warranty Suunto warrants that during the Warranty Period Suunto or a Suunto Authorized Service Center (hereinafter Service Center) will, at its sole discretion, remedy defects in materials or workmanship free of charge either by a) repairing, or b) replacing, or c) refunding, subject to the terms and conditions of this Limited Warranty. This Limited Warranty is only valid and enforceable in the country of purchase, unless local law stipulates otherwise. Warranty Period The Limited Warranty Period starts at the date of original retail purchase. The Warranty Period is two (2) years for display devices. The Warranty Period is one (1) year for accessories and consumable parts, including but not limited to chargeable batteries, chargers, docking stations, straps, cables and hoses. Exclusions and Limitations This Limited Warranty does not cover: 1. a) normal wear and tear, b) defects caused by rough handling, or c) defects or damage caused by misuse contrary to intended or recommended use; 2. user manuals or any third-party items; 3. defects or alleged defects caused by the use with any product, accessory, software and/or service not manufactured or supplied by Suunto; 4. replaceable batteries. This Limited Warranty is not enforceable if item: 1. has been opened beyond intended use; 2. has been repaired using unauthorized spare parts; modifi ed or repaired by unauthorized Service Center; 3. serial number has been removed, altered or made illegible in any way, as determined at the sole discretion of Suunto; 4. has been exposed to chemicals including but not limited to mosquito repellents. Suunto does not warrant that the operation of the Product will be uninterrupted or error free, or that the Product will work with any hardware or software provided by a third party. Access to Suunto warranty service You must have proof of purchase to access Suunto warranty service. For instructions how to obtain warranty service, visit www.suunto.com/warranty, contact your local authorized Suunto retailer, or call Suunto Help Desk +358 2 2841160 (national or premium rates may apply). 11

Limitation of Liability To the maximum extent permitted by applicable mandatory laws, this Limited Warranty is your sole and exclusive remedy and is in lieu of all other warranties, expressed or implied. Suunto shall not be liable for special, incidental, punitive or consequential damages, including but not limited to loss of anticipated benefi ts, loss of data, loss of use, cost of capital, cost of any substitute equipment or facilities, claims of third parties, damage to property resulting from the purchase or use of the item or arising from breach of the warranty, breach of contract, negligence strict tort, or any legal or equitable theory, even if Suunto knew of the likelihood of such damages. Suunto shall not be liable for delay in rendering warranty service. 12

SUUNTO HELP DESK GLOBAL +358-2-284-1160 USA (toll-free) +1-800-543-9124 CANADA (toll-free) +1-800-267-7506 www.suunto.com Suunto Oy 11/2005, 09/2006, 11/2011. All rights reserved. Suunto is a registered trademark of Suunto Oy.