SR MARINER DIGITAL DEPTH METER DDM- 1 DDM- 2 INSTALLATION INSTRUCTIONS

Similar documents
INSTALLING THE ECHO SOUNDER TRANSDUCER CHANGING THE OPERATING CONFIGURATION

Depth transducer TH 52

Depth sensor. Product reference : REV 1. USER GUIDE and INSTALLATION GUIDE. nke Sailing competition

DESIGNED AND MANUFACTURED IN ENGLAND CLIPPER DEPTH DEPTH METRES ECHO SOUNDER.

Copyright 2004 by the Thomas G. Faria Corporation, Uncasville CT No part of this publication may by reproduced in any form, in an electronic

Panoptix PS51-TH FrontVü/LiveVü Thruhull

WIND CLIPPER KTS ILLUM SCALE INC DEC CLIPPER WIND SYSTEM

INTRODUCTION TO NETWORK WIND 3 MOUNTING THE UNIT 14 SELECTING THE DISPLAY MODE 5 ABBREVIATIONS AND DEFINITIONS 17

RUDDER KIT INSTRUCTIONS

CLIPPER DUET M P H DEPTH F E E T SPEED TOTAL TRIP ILLUM. Duet COMBINED LOG AND ECHO SOUNDER

CLIPPER DEPTH METRES ENTER SHALL DEEP ILLUM CLIPPER ECHO SOUNDER

Installation, Compensation and Maintenance Instructions for. RITCHIE Compasses. Made In U.S.A

INSTALLATION AND USER INSTRUCTIONS for TARGET 2 LOG, DEPTH & WIND MARINE INSTRUMENTS

DIRECT DRIVE DIXIE DOUBLE SEAMER Model 25D

User Manual for the Mars Calibration Bench

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

MAINTENANCE PROCEDURE FOR X 650

PIRANHA I & 2 OPERATION GUIDE

Shoreline Cantilever Lift 2500lb Capacity Models: (108" inside width) - Part # (120" inside width) - Part #

Model No. D10D INSTALLATION AND OPERATION MANUAL D10DX.01T Digital Depth Sounder with Air & Water Temperature, Transom Mount Transducer

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

RAI-M series RUDDER ANGLE INDICATOR SYSTEM

Operation Manual Guillotine Cutter RC-5

Paddle Bar Replacement

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

Pressure Dump Valve Service Kit for Series 3000 Units

1.0 - OPENING AND CLOSING THE DOOR

Sideshift SS230 Installation on a 2006 Bayliner 265SB

Pressure Dump Valve Service Kit for Series 2300 Units

MANUAL BE SERIES Test Benches

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

P5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Hydrostatic Pressure Testing

Row Marker OEM /

HP-104 & HP-106 Tapping Machine OPERATIONS MANUAL

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Drawn up by: / RK Revision: 01 Reviewed: Page: 1 of 23 HI-SR 540 USA. Operating instruction SR 540 Face Shield

Assembly Instructions. -Cantilever Boat Lifts

Planning and general precautions ithrust Tunnel Systems installations.

I.H.S INSTALLATION INSTRUCTIONS

ULTIMATE 12 RUDDER INSTALLATION INSTRUCTIONS

Confer Plastics Inc. - Installation Manuals CONFER PLASTICS, INC. CONFER PLASTICS, INC. POOL ENTRY SYSTEM FOR ABOVE-GROUND POOLS

TECHNICAL DATA. Q = C v P S

Chapter 2 Rigging. Cutting Wire Rope. Anchoring Wire Rope to Drum. Winding Wire Rope Onto Drum

bathrooms.com Concentric Thermostatic Shower Mixers Cleaning and Care Installation Manual Contents

TECHNICAL DATA. Q = C v P S

Misaligned Folds Paper Feed Problems Double Feeds Won t Feed FLYER Won t Run iii

TECHNICAL DATA. Q = C v P S

AGM 33 PIKE ALL FIBERGLASS. Specifications Length: 92 Diameter 5.5 Weight: 24 lbs Motor Mount: 75mm Fins: 6-3/16 G10 CP: 68 from nose tip Parts List

MASTER TRUING STAND TS-3. Optional Dial indicator set with brackets Dial indicator bracket set only

TS1. Ultrasonic Tank Sender. Installation and Operating Instructions. For TS1 Firmware v3.8. Page 1 INST-TS1-V13 18/11/10

INSTALLATION INSTRUCTIONS

For ELECTRIC ANCHOR WINCH Models: T Pontoon 35 T sw Salt Water Series Coastal 35

Model No. D10D INSTALLATION AND OPERATION MANUAL D11S Surface Mount Digital Depth Sounder with Transom/Glue-In Transducer

(PLEASE CONTACT YOUR LOCAL DEALER or CUSTOMER SERVICE FOR WARRANTY INFORMATION)

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50 Systems Outfitted with ABM-725 Monitor C O M P A N Y

2,500/4,000 LB Easy Riser Vertical Cable Feighner Lift

INSTRUCTION GUIDE S-WORKS ROAD CARBON CRANKSET (Carbon and Alloy OSBB cups)

Ladies Shopper Bike Assembly Manual 28C03

What hull material types will the system work on? Do I still need an antifoul paint?

Installation Instructions

Congratulations, once again, on buying an E RIDER Model 18!!!!

mn100 Analog Display

Precision Liquid Settlement Array Manual

Operation Manual Piston Sensed Gas Pressure Regulators

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

LITERIDER 2&3 IMPORTANT WARNING. 2Bike (1x) Bolt (1x) Nut (1x) Small Hex Wrench (1x)

Gas Valve Replacement Kit

256 Pneumatic Pressure Indicator

IMPORTANT SAFETY INSTRUCTIONS

GENUINE CARGO NET INSTALLATION AND USER S INSTRUCTIONS

Big Ride ASSEMBLY AND INSTALLATION INSTRUCTIONS * * C A U T I O N * *

Supplementary instructions. Rod and cable components. for VEGAFLEX series 80. Document ID: 44968

with O 2 Controller Instruction Manual

Preferred Instruments Danbury, CT USA

PURA. Pure Gas Dewpoint Transmitter. Users Guide

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

15ME-014 INSTRUCTION MANUAL OF STERN TUBE SEALING TYPE EVK2RV. URL

Falcon 3 145, 170, 195 and Tandem Owner / Service Manual

TECHNICAL DATA. Q = C v P S

PRODUCT SUPPORT MANUAL YACHT BEAM 6M Searchlight Remote Control System with Joystick Remote Control Panel

SDX Submersible Depth Transmitter User Manual

PART NUMBER: E361SXA200 DESCRIPTION: KAYAK CARRIER

MUELLER A A Non-Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

Regulators repair and maintenance. XS Compact 2nd stage. January 2014 Rev XSC /3 Ed. C /14 1

For ANCHOR WINCH Model: T Big Water 45 T sw Salt Water Series Big Water 45

SPM INDOOR TRAINING CYCLE ASSEMBLY MANUAL MODEL: SPM

ICE PROTECTION - PROPELLER

DM-RD (English) Dealer s Manual. ROAD Rear Derailleur RD-9000 RD-6800 RD-5800 RD-4700

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &

IMPALA CONTROL PANEL CONVERSION KIT an ISO 9001:2008 Registered Company REV E 4/13/ IMPALA CNTRL PNL INST PG 1 OF 16

Section 3000 CONVEYOR CHAIN LUBRICATION SCHEMATIC...39 AIR OPERATED SPRAY DISPENSERS - CENTRAL ACRYLIC RESERVOIR Section 3000 Index

Bladerider X8 Assembly Help Notes

General Information. NTA607HD Lift Assist Adjustments. Tools Required. Work Location. Notations and Conventions U B F D R B F L

Arbor Terminator Press Operation Manual For IDT Connectors Order No Engineering No: AM

Digital Depth Sounder Display Installation and Operation Manual. time for you to react.

MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

Operating Procedure TITON SUBSEA BOLT TENSIONER

QUALITY ALUMINUM BOAT LIFTS, INC. INSTRUCTIONS. Dominator Lake Lift

ASSEMBLY & USE MANUAL

Transcription:

SR MARINER DIGITAL DEPTH METER DDM- 1 DDM- 2 INSTALLATION INSTRUCTIONS Congratulatio n s in choosing a high perfor m a n c e marine instru m e n t and welcome to the growing family of SR Mariner produc t owners. Since our establish m e n t in 1973, we have engineered our prod uc ts to give you quality at a reaso na ble price. To familiarize yourself with all the feature s and installation proced u re s please read the following instructions carefully. If you still have any questions or comme n t s please call your neares t dealer or call us at (716) 693-5977 or write: SR Instruments 600 Young Street Tonawand a, NY 14150 Attn: Service Department It is recommended that you temporarily hook up your SR MARINER equipment before installation so that you become familiar with its connection s and syste m perfor m a n c e. DO NOT CUT ANY CABLES, but connect according to wiring diagra m (fig.3). Put the trans d u c e r in a pool of water or hang it over the side of the boat to test the syste m. If all functions perfor m satisfactorily, proceed with installation. If the syste m fails to perfor m, check all connection s. If system still fails to perfor m check with your dealer for advice and/ o r replace me n t if neede d. CHARACTERISTICS OF DIGITAL DEPTH METER MODEL FEET METERS FATHOM VISUAL ALARM DDM- 1 2-300 N/A.5-50 YES DDM- 2 N/A 1-100.5-50 YES Note: Optional audible alarms are available for meters.

INSTALLING THE DISPLAY 1. Cut a 4-1/16" (max 4-1/8") diameter hole in the bulkhead or instrument panel where the display unit is to be mounte d (fig.1). 2. Be sure to remove all burrs and clean the face of the bulkhea d or panel with deterge n t to remove all traces of dirt, oils, fingerprin ts, etc... 3. Each display unit is furnishe d with an adhesive backed sealing ring to hold the unit fast in place and creates a watertight seal. Please note that it is not recom m e n d e d that the paper backing be remove d until the syste m is tested and finally calibrate d. When ready for final mounting simply remove the paper backing, position unit correctly and firmly press into place. 4. Install the RETAINING RING as shown and tighte n with a blade type screwdriver. NOTE: Maximum hull thicknes s for thru hull fitting is 1-1/ 4 (Figure2)

INSTALLATION TIPS FOR TRANSDUCERS SAILBOATS: The preferred position of the trans d u c e r is where water is diverging aroun d the hull and is free from turbule nce and eddies. This is generally in the forward one- third of the hull in front of the keel and approxima t ely one foot off the centerline. Generally the knot meter trans mit t er can be mou n te d on one side of the keel with the depth trans d u c e r in a similar position on the opposite side of the keel. If due to access consideratio n s, it is necessary to locate the dept h trans d uc e r and the knot meter trans mit te r on the same side on a fore and aft line, be sure to locate the dept h trans d uc e r forward of the knot meter trans mit te r so that the turbulence created by the paddlewheel does not interfere with the depth sensor. The depth trans d uc e r should be installed in a fairly flat area where the degree of angle does not exceed 20 degrees (you can use fairing blocks to accom plis h this). An alterna te location is along side the keel two feet away and ahead of amids hi p s. The thru hull fittings require a 2 1/8" hole with a 30 degree flange. SR Mariner provides a tool (THT) that drills and flares this hole in one operatio n. If this tool is not available locally contact the factory and arrange m e n t s can be made to rent one (the THT tool requires an 1/2" drill motor). NOTE: The thru hull fitting should already have an o- ring installed. INSTALLING THE TRANSDUCER THRU HULL: Choose the location of the sensors and cut your holes for the thru hull fittings. File a notch FACING FORWARD to seat the key way. The key way ensures proper orientation of the sensor s for use and/ o r mainten a nc e. After proper fit is secure d, place bedding compo u n d arou n d the lip and body of the fitting where it will be in contact with the hull. Insert the thru hull fitting and tighten the fitting nut by using a span n e r wrench or tap with a small wooden block against the nut to provide a snug fit. DO NOT OVER TIGHTEN! CEMENTED TO HULL: If your primary importa nc e is for shallow water monitoring, the trans d u c e r may be cemente d to the hull thereby eliminating a need for a hole throug h the hull. The position selected must not have air voids, balsa fillers, etc It is best to choose a location and make a small putty dam and fill it with water and put your trans d u c e r in it to see if a stable depth is indicate d (the boat should be afloat and the trans d uce r face should be wetted before inserting into puddle). At this point back off on the gain until reading become s unstable to see how much reserve gain is available. Compare this gain setting with the trans d u c e r hung overboar d; this will give an approxima tion of attenua tion at the chosen location. If operation is suitable, clean the surface of the trans d uce r with lacquer thinner to remove the anti- fouling paint. Clean the hull to remove grease and mold release. The trans d u c e r may now be cemente d with epoxy or fiberglass resin (stir the epoxy slowly to avoid air bubbles). THERE SHOULD BE NO AIR BUBBLES IN THE ADHESIVE BOND.

FOLLOW THE MOUNTING INSTRUCTIONS FOR DISPLAY AND TRANSDUCER BEFORE PROCEEDING: 1. Connect the trans d uc e r and power wires to the display unit as shown in figure 3. 2. If you choose to connect night lighting simply connect your 12 volt D.C. wire as indicate d in figure 3 and install a SPST switch on the positive (+) line to complete the circuit and activate the lights. 3. To set alarm, turn the left knob on instru m e n t to SET. Next, turn the right knob to desired alarm setting. The visual alarm (and DA- 1, if installed) will be activated when depth is at or below alarm setting. (Figure 3) CALIBRATION GAIN: The rear GAIN control is a manual override on the auto m a tic gain control (AGC) and is used to set the maximu m gain. It usually is factory set to be fully clockwise (maximu m gain) for the greatest sensitivity, however sometime s turbulence, ignition or electrical disturb a nc e, or spurious reflections from the keel may make the readings unstable. If this occurs, turn the GAIN control counter clockwise slightly until the readings stabilize. SHALLOW GAIN: When the trans d uc e r sends out its signal, it can receive a reflection from the keel, pilings or other nearby objects before the reflection from the botto m. To eliminate the return s from these unwante d signals, the SHALLOW GAIN must be adjus te d. For best results start in 10-15 feet of water and turn the SHALLOW GAIN clockwise until the readings are substa n tially less than the actual dept h. Now turn counter clockwise until the readings return to the actual dept h. Repeat this proced ur e while under way. KEEL OFFSET: The display can be adjuste d to display depth s from surface of the water to botto m, from the keel to bottom, or transducer to bottom - the unit is factory set for transducer to bottom. If you desire a different set up then measu re the water depth with a lead line and adjus t the KEEL OFFSET clockwise for a lower reading (keel to botto m) or counter clockwise for a higher reading (surface to botto m). Each indicator represe n t s a 1 foot increme n t.

POWER CONSUMPTION LIGHTS AMPS OFF.020A ON.175A ACCESSORIES ICW- 1 INSTRUMENT COVER O- RING GASKET FOR THRU- HULL DP- 1 DUMMY PLUG CLP RNG CLAMP RING MC- 1 METER CASE FOR (YOUR MODEL NUMBER) SEAL RING GASKET FOR INSTRUMENT GAUGE TH- 1 THRU- HULL FITTING DA- 1 AUDIBLE DEPTH ALARM Made in the USA