Product Technical Data and Certification PASSPORT OF GOODS. Q-SEAL SYSTEM (multiple seal) Ruma Products BV. Hoogeveen Holland.

Similar documents
What is required to Engineer, Test and Qualify Swelling Elastomers Seals.

Torque Turn Tests on Q-Slip Sleeve holding down screws Ref: RP/2014 Eng. Jan A

Rate of Flow Valve Series 120

AUTOMATIC HOSE TEST UNIT, TYPE SPU

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures

// ADapters GUIDelines

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

FILTER BYPASS CONTROL

Standard Operating Procedures

HYGIENIC SIGHT FLOW INDICATORS

BACK PRESSURE / SUSTAINING

BACK PRESSURE / SUSTAINING

Avenger Model 33M Installation & Operation Instructions

Supratec Gesellschaft für Umweltund Verfahrenstechnik mbh OXYFLEX - M T / M T M E M B R A N E D I S C D I F F U S ER AERATION TECHNOLOGY

DRILLING HOSE SOLUTIONS

Engineered solutions for complex pressure situations

SCA Series Inverted Bucket Steam Traps

Flexible hoses - Non-metallic materials

WHEATLEY Series 500 Swing Check Valve

DEPARTMENT OF ENVIRONMENTAL PROTECTION Office of Oil and Gas Management

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

Casing Design. Casing Design. By Dr. Khaled El-shreef

Electro-Magnetic Flowmeters Electromagnetic Sensor

Constant Pressure Crude Oil Container Model CPCCP

TYPE ECS SEAL METAL BELLOWS DRY-RUNNING SECONDARY CONTAINMENT Technical Specification

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

LIGHTWEIGHT TRIWALKER OWNER S HANDBOOK

SECTION SHOWER AND BATH ENCLOSURES. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

Standard Operating Procedure Measuring & Testing Equipment

ST 18 Aluminium Gas Model

Type BBS-03, BBS-05, BBS-06, BBS-25

5k Slickline Lightweight Pressure Control Equipment 4 ID

Declaration of Performance (DOP)

DK ton, Double-acting, Die-type Crimping Tool

BSI BSI 5200 THE NEW CAST 60 FITTINGS AN EASY ASSEMBLY A KNOWN PRODUCT, SAFE AND RELIABLE AVAILABLE IN CARBON AND STAINLESS STEEL

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment

Installation Operation Maintenance

Installation, Operating, Inspection and Maintenance Instructions Ladder Climber s Safety System. Warning

QUICK CONNECT FOR 2.0, 4.0 & 5.0 GASES

92831 TEL: (714) FAX:

North American sealing solutions Bridge Plug Ball Drop Frac Plug Caged Ball Frac Plug

ST 18 Aluminium Gas Model

INSTALLATION & MAINTENANCE INSTRUCTION

Bulletin Swimming pool, hot tub and spa installations Rules , , , , , and

Connecting hoses. Type FS. Connecting hoses for the water-side connection of air- water systems and decentralised ventilation units PD FS 1

3/16 Pitch Silent Chain P R E C I S I O N E N G I N E E R E D

ALE-40. R06 Miniature Brass Body Regulator. Water and Compressed Air Service 1/8" and 1/4" PTF Port Sizes. Air line equipment.

North American Orifice Metering System

Precision and Instrument Regulators 1/4" port size

Model Visit our website at:

LIFTING RIG Multi-Product Installation Rig

Success Paths: A Risk Informed Approach to Oil & Gas Well Control

3/16 Pitch Silent Chain P R E C I S I O N E N G I N E E R E D

Media-Isolated Mag Plus Probe Low Pressure-ISO Kit

USM21 Sealed Bimetallic Steam Trap for use with Pipeline Connectors Installation and Maintenance Instructions

Certificate and test report Nr. J144CON Coupling system for solar thermal applications. Test according to SPF test procedure: Test class A1

GAS STRUT SAFETY INFORMATION

HOT OILING OPERATIONS ALL HSE PRC 172. Approved By: Manager, HSE Performance Assurance. Table of Contents

ISO INTERNATIONAL STANDARD

BioAerosol Nebulizing Generator. Operation and Maintenance User Manual

PLT LINE THROWER RESTECH NORWAY AS USERS MANUAL RESCUE 230

(1) Type (2) Cylinder dia. (3) Gripper action : Single-acting closing gripper (normally open) (4) Holder type

Automatic Balancing Valve Pressure difference controller with integrated flow limiter AB-PM DN

Series IRV1000/2000/3000

DESIGN AND PRE - INSTALLATION INFORMATION

FLOW CONDITIONER «EMIS-VEKTA 1200» EMIS-VEKTA 1200.UM.PS v User manual Passport. «EMIS», CJSC Russia, Chelyabinsk

VTL VFL VCL. Low Profile Series V RIGGING & ASSEMBLY INSTRUCTIONS

Model MTB-ASME Vertical Bladder Tanks

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

Pressure-Relief Cartridge Valve, Size 4

Model MTB-ASME Horizontal Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks

Smooth Vent Valve. XVD Series

East Building, PHH-30 U.S. Department New Jersey Avenue S.E. of Transportation Washington, D.C DOT-SP (FOURTH REVISION)

USER MANUAL. MACMAG magnetic separator MHK MHF

Cautions : 1. Be careful when you release the Stop Fitting with some internal pressure

6-way characterised control valves DN15 and DN 20

ABB Instrumentation. Specifications. MagMaster Plus MFF Series Electromagnetic Sensors. MagMaster Plus bringing unsurpassed flowmetering performance

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

STAG. Balancing valves Balancing valve with grooved ends DN

Cautions : 1. Clogging of the element raises resistance to exhaust, thus lowering the

Personal Protective Equipment

EXPIRATION DATE: (FOR RENEWAL, SEE 49 CFR ) 1. GRANTEE: Structural Composites Industries (SCI) Pomona, CA

Horizontal Bladder Tanks

ASB Accumulator Safety Blocks

MDX² INSTALLATION MANUAL (RETROFIT FIBERGLASS, VINYL & CONCRETE POOLS WITH MDX)

World Area Differences Technical Information

Vertical and Horizontal Bladder Tanks

Guide for Evaluating Your Hose Assembly Supplier

DK46 - DK800 Supplementary instructions

Smooth Vent Valve. Series XVD XL XL Q D- XVD XGT CYV

Filling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series

East Building, PHH-30 U.S. Department New Jersey Avenue S.E. of Transportation Washington, D.C EXPIRATION DATE: June 30, 2015

STAD. Balancing valves DN 15-50

Vertical Bladder Tanks

Smallbore rifle CZ99 PRECISION..22 Long Rifle.22 Win. Mag. R.F..17 Hornnady Mag. R.F.

Bladder Accumulators High pressure

"Sharing To Be Better. Influx through failed cement in shoetrack during completion operations

Inverse Proportional Pressure-Relief Cart., Size 2 4

TWO POST RAM PACKAGE 5 GALLON READ THIS MANUAL CAREFULLY BEFORE INSTALLING, OPERATING OR SERVICING THIS EQUIPMENT.

Transcription:

Product Technical Data and Certification PASSPORT OF GOODS Q-SEAL SYSTEM (multiple seal) Ruma Products BV. Hoogeveen Holland.

PASSPORT OF GOODS Content Background Information... 2 Composition... 2 Function and External Views... 3 Technical Features... 4 Q-Multiple Seal Running Instructions.... 5 Maintenance... 6 Transport and Storage.... 6 Manufacture Certification... 7 Manufacture Contact Information.... 9 Manufacture Stamp and Signature... 9 Page 1 of 9

Background Information PASSPORT OF GOODS Note: Ruma Products supports the aim and objectives of the U.S. legislation on the supply of conflict minerals. Ruma Products assures that their products and processes are free from the specified metals. 1. A Q-Multiple Seal is a bonded-to-pipe swelling seal system with 2 mounted bright zincplated steel Centraliser / Running guides and locking section. 2. The Q-Multiple Seal is designed to be bonded onto Oil Country Tubular Goods at a desired position. 3. Bonding is achieved by the use of primer, bonding agent and vulcanizing of the elastomer onto Oil Country Tubular Goods. 4. The Integral Elastomer sections are intended to swell in Contact with a Motive Fluid to create multiple pressure barrier seals between the outside of the tubing it is bonded to and the Inside Diameter of the Containment section. 5. The Q-Multiple Seal by its nature is a one-time-use item that cannot be re-used. 6. The Q-Multiple Seal can be used in all markets without limitation 7. The Q-Multiple Seal does not contain or use Conflict Minerals 8. The Q-Multple Seal is manufactured according to ISO 9001-2008 certification. 9. The Q-Multiple Seal is manufactured in ISO 14001 certified facilities 10. The Q-Multiple Seal is produced by Ruma Products BV, The Netherlands Composition 1. One Q-Multiple Seal Consists of: Multiple Swelling Elastomeric Sealing Sections 2 pieces bright zincplated steel running guides/centralizers A series of Stainless Steel Locking Grub Screws The individual pieces cannot be used separately from another and constitute a completed Whole. Page 2 of 9

Function and External Views PASSPORT OF GOODS The Q-Multiple Seal is Used as a bonded-to-pipe Swelling Seal to be vulcanized onto OCTG to enable swelling Sealing barriers to be fitted to on site. Q-Multiple Seal External View Note for illustration the Seal sections are illustrated in three water swelling elements for clarity. Page 3 of 9

Technical Features PASSPORT OF GOODS 1. Q-Multiple Seal Size is a. Number of seals XX pcs b. Diameter XXX Inches c. length XX Inches d. OCTG Size XX Inches. 2. Operating Temperature range is XX to XXX degree Celsius 3. Q-Multiple Seal Components are manufactured from a. Base pipe XXX b. Connections XXX Box x Pin c. Sealing elements (Oil) X-XX Swelling Elastomer d. Sealing elements (Water) X-XX Swelling Elastomer 4. Swelling Elastomer is designed to operate in a. Oil Swelling motive fluid Type OBM b. Water Swelling motive fluid Type Water based fluid c. Motive Fluid Salinity XX% d. Operating Temperature XX to XXX Celsius e. Time to First Contact XX - XXX Hours f. Time to Seal XXX Hours g. Maximum Operating pressure XXX Bar Page 4 of 9

PASSPORT OF GOODS Q-Multiple Seal Running Instructions. 1. Ensure that packaging has not been damaged and is in place. In the event that packaging has been damaged visually inspect the Swelling Seal Elastomer for both damage and localised swelling. If damage is present or swelling has occurred quarantine this item and use backup seal. Make good detailed colour photos of the damage and or swelling and contact Ruma Products with copies from these for advice on next step with this Item. 2. On the Rig Floor remove all wrapping material and install the Swelling Seal in the Tubing string, ensure that care is taken not to damage the swelling sealing surfaces. Please note the following. Record the Swelling Q-Multiple Seal Serial Number and technical Information. Check the Equipment to be run is the correct Item as specified in the Company Completion Program. The Q-Multiple Seal is fitted with running guides in front of and behind the both outside Seal Sections. These are factory fitted with a 5-10 mm gap between the outside seals and the running guides. Ensure that this is correct and that this has not been altered. In extreme Cold Conditions Elastomer can be extremely brittle and will shatter if mechanically shocked. Ensure the Q-Multiple Seal has a temperature higher than -10 Celsius to ensure this cannot occur. Ensure that the anticipated completion time to get Q-Multiple Seal to Depth corresponds with the delivered swelling versus time curve. Note: In worse case conditions the curve should allow for time to get to depth as well as time to pull back to surface. Page 5 of 9

PASSPORT OF GOODS Ensure care is taken when running through the BOP and proceed to run into the well in a similar manner to all normal completion equipment. Be aware that time should NOT be allowed to slip during the running procedure. Swelling is CONTINUOUS once in contact with well fluids. 3. Important Information: Water swelling elastomers and their speed and degree of swell is Influenced by the following factors: Fluid temperature. The Higher the temperature the more rapid is the swell. Fluid Salinity: The sweeter the Fluid The more rapid is the swell. In the event of delays and difficulties with running Long liners the following needs to be considered. To delay water swell Hold the Completion Brine as cold as possible and as saline as conditions allow. In the event that these conditioning steps are not possible consider ADDING GLYCOL or SIMILAR to the completion Brine. GLYCOL has the effect of altering the Diffusion Gradient of the Completion Brine, reducing and or stopping the rate of swell. This Completion Mixture would have to be circulated out of the well once the problems requiring its use have been eliminated. Maintenance No maintenance is required Item is not to be exposed to rain water or other water sources. Transport and Storage. Store in a dry dark warehouse in original transport packaging. Item can be transported by plane, ship, rail or road and requires no specific special or specific handling or safety instructions. Page 6 of 9

Manufacture Certification PASSPORT OF GOODS Page 7 of 9

PASSPORT OF GOODS Page 8 of 9

PASSPORT OF GOODS Manufacture Contact Information. Ruma Products B.V. Zeppelinstraat 5 7903 BR Hoogeveen The Netherlands Tel. +31 (0) 528 260 160 E-mail: sales@oblique.eu Manufacture Stamp and Signature Page 9 of 9