Project 184 Preferred Canal Drainage Structure and Release Point Plan

Similar documents
Pre-Application Document Kaweah Project (FERC Project No. 298)

FINAL Caples Lake Fisheries Management Plan. Version 4.0

USING A LABYRINTH WEIR TO INCREASE HYDRAULIC CAPACITY. Dustin Mortensen, P.E. 1 Jake Eckersley, P.E. 1

145 FERC 62,070 UNITED STATES OF AMERICA FEDERAL ENERGY REGULATORY COMMISSION

Suitable Applications Check dams may be appropriate in the following situations: To promote sedimentation behind the dam.

FERC Project 184 ECOLOGICAL RESOURCES COMMITTEE

107 FERC 61,282 UNITED STATES OF AMERICA FEDERAL ENERGY REGULATORY COMMISSION

Packwood Lake Intake Screen Velocity Test Report for Energy Northwest's Packwood Lake Hydroelectric Project FERC No Lewis County, Washington

Final Bull Trout Redd Monitoring Report for the Wallowa Falls Hydroelectric Project

Huntington District. For More Information Contact (304)

Illinois State Water Survey

THREATENED, ENDANGERED, AND SENSITIVE SPECIES 2010 ANNUAL REPORT

JAP Additional Information Sheet

Trout Unlimited Comments on the Scope of Environmental Impact Statement for the Constitution Pipeline Project, Docket No. PF12-9

STRUCTURE 65-B PURPOSE SPILLWAY OPERATION

Deschutes Basin Habitat Conservation Plan. Working Group Meeting December 14, 2017 Redmond, Oregon

APPENDIX J HYDROLOGY AND WATER QUALITY

STRUCTURAL STABILITY ASSESSMENT

REC 6 FISHERIES HABITAT EVALUATION

STRUCTURE S-65 PURPOSE SPILLWAY OPERATION

Redd Dewatering and Juvenile Salmonid Stranding in the Lower Feather River,

APPENDIX A STRUCTURE DESCRIPTIONS AND RATING CURVES

As temporary grade control facilities along waterways until final stabilization is established.

Public Notice. Corps File No. LRE Date: March 19, 2017 Expires: March 18, 2022

Final Bull Trout Genetics Monitoring Plan for the Wallowa Falls Hydroelectric Project. (FERC No. P-308) June 2017

Hydraulic Modeling to Aid TDG Abatement at Boundary and Cabinet Gorge Dams

CHAPTER X: PORTAGES AROUND DAMS

Final Fish Salvage & Temporary Tailrace Barrier Report for the Wallowa Falls Hydroelectric Project Tailrace. (FERC No. P-308) December 18, 2017

APPENDIX C VEGETATED EMERGENCY SPILLWAY. VERSION 1.0 March 1, 2011

Scott Dam Spillway Comparing Physical Model Study Results

PROFILE OF SACRAMENTO RIVER, FREEPORT TO VERONA, CALIFORNIA,

PRELIMINARY RISK ASSESSMENT RIDM PROJECT FOR A DAM WITH A VEGETATION- LINED SPILLWAY AND FERC PILOT

Subject: Wells Hydroelectric Project FERC Project No Bull Trout Management Plan and Incidental Take Annual Report

(Revised February,2005) CULVERTS, BRIDGES, AND FORDS

D.B. Wilson Station CCR Landfill

Rugraw, LLC is the Applicant for FERC Project No Lassen Lodge Hydroelectric Project (LLHP).

DECISION MEMO. Pursuant to 36 C.F.R (e), the following persons are exempted from this order:

San Lorenzo Valley Water District, Watershed Management Plan, Final Version Part I: Existing Conditions Report

P U B L I C U T I L I T Y D I S T R I C T N O.

DAIVÕES DAM SPILLWAY: A NOVEL SOLUTION FOR THE STILLING BASIN

Shovelnose Creek Off-Channel Complex Berm Repair

Final Fish Salvage & Temporary Tailrace Barrier Report for the Wallowa Falls Hydroelectric Project Tailrace. (FERC No. P-308) December 20, 2018

HISTORY OF CONSTRUCTION

Electronic Filing. Thank you for your assistance. Please call if you have any questions or need additional information.

Attached as Exhibit B-2 is BC Hydro's presentation from the Stave Falls Spillway Gates Project Workshop held on January 18, 2010.

FINAL Fish Salvage Plan for the Wallowa Falls Hydroelectric Project Tailrace. (FERC No. P-308) April 19, 2017

SETTLEMENT AGREEMENT

Assessment of Baseline Geomorphic Features at. Proposed Stream Crossings On The Proposed County Road 595. Marquette County, Michigan

BATTLE CREEK FISHERIES STUDIES TASK 4: SURVEYS OF BARRIERS TO THE UPSTREAM MIGRATION OF ANADROMOUS SALMONIDS

Low Gradient Velocity Control Short Term Steep Gradient Channel Lining Medium-Long Term Outlet Control Soil Treatment Permanent [1]

Interim Guidance Fish Presence Absence

Lecture 10 : Sewer Appurtenances

Steve Hemstrom Sr. Fisheries Biologist Chelan PUD Natural Resources Desk: Cell:

Notice of Intent to Close Inactive CCR Surface Impoundments

Annex E Bridge Pier Protection Plan

FERC Division of Dam Safety & Inspections

Coal Combustion Residuals Closure Plan

Project Award Presentation

Plan B Dam Breach Assessment

Session C9: Priest Rapids Fish Bypass: A Case Study from Start to Finish

M EMORANDUM O CTOBER 6, 201 6

P U B L I C U T I L I T Y D I S T R I C T N O.

Tide Gate Modifications for Fish Passage and Water Quality Enhancement

Appalachian Adventure Unguided Tour #5

INFILTRATION PRACTICE MAINTENANCE INSPECTION FORM

Abundance of Steelhead and Coho Salmon in the Lagunitas Creek Drainage, Marin County, California

Lewis River Hydroelectric Projects Settlement Agreement Aquatic Coordination Committee (ACC) Meeting Agenda

SACRAMENTO MUNICIPAL UTILITY DISTRICT UPPER AMERICAN RIVER PROJECT (FERC Project No. 2101) and

NUMERICAL AND PHYSICAL MODELING

SOUTH CAROLINA ELECTRIC & GAS COMPANY COLUMBIA, SOUTH CAROLINA

April 14, Subject: Rocky Reach Hydroelectric Project, FERC No Rock Island Hydroelectric Project, FERC No

Design of Spillway Upgrades

Washington State Fish Passage Barrier Removal Projects. Casey Kramer, PE WSDOT State Hydraulics Engineer

PRE- PROPOSAL FORM - Lewis River Aquatic Fund

Colusa Basin Drain Watershed Fish Stranding Tour Concept Paper Mike Hendrick and Brycen Swart NMFS

ANNUAL INSPECTION BY A QUALIFIED PROFESSIONAL ENGINEER ALL CCR IMPOUNDMENTS CCR Rule Section (b)

LESOTHO HIGHLANDS DEVELOPMENT AUTHORITY

The Hydraulic Design of an Arced Labyrinth Weir at Isabella Dam

TABLE OF CONTENTS 1.0 INTRODUCTION PLAN CERTIFICATION (B)(4) 1

7.Site Note Poders in Labutta Township Labutta North Polder Shansu Sluice Gate - Shansu sluice locates in Labutta (North) polder, it is about 1.5 km n

STREAM SURVEY File form No..

Whitewater Valley Station Surface Impoundment Coal Combustion Residual Annual Report

REPORT TO THE MINISTER OF NATURAL RESOURCES. Pursuant to an appointment made by the Honourable Frank S. Miller, Minister of Natural

Dams as Systems. Pat Regan Federal Energy Regulatory Commission (FERC)

What I ve Learned About Dam Safety Good, Bad and Ugly

Clackamas River Hydroelectric Project Whitewater Kayaking on the Oak Grove Fork

What Happens Downstream Stays Downstream, or Does It? Potential Failure Modes from Spillway Exit Flows

Initial Annual CCR Landfill Inspection OML Existing Landfill OML Expansion Phase 1

Summary of the Pilot Assessment of Three Potential Fish Barriers on Battle Creek

Yale Reservoir Kokanee (Oncorhynchus nerka) Escapement Report 2016

Designing Labyrinth Spillways for Less than Ideal Conditions Real World Application of Laboratory Design Methods

APPENDIX A STRUCTURE DESCRIPTIONS AND RATING CURVES. Lake Okeechobee & EAA Vol 3 A-i December 2005 Version 1 Draft 4

SUBMERGED VENTURI FLUME. Tom Gill 1 Robert Einhellig 2 ABSTRACT

TOP:001.3 U.S. Fish and Wildlife Service TECHNICAL OPERATING PROCEDURE

Chadbourne Dam Repair and Fish Barrier

Three-Year Summary Report. Prospect Whitewater Boating Flow Release. and. Whitewater Boating Access Monitoring Study

HYDRAULIC JUMP AND WEIR FLOW

Proposed Reclassification of Muskrat Creek, North Platte River Basin in Goshen County, Wyoming

TABLE OF CONTENTS LEGAL NOTICE

M E M O R A N D U M. Garcia and Associates P.O. Box 1268 Tahoe City, CA Phone: (530)

Transcription:

Project 184 Preferred Canal Drainage Structure and Release Point Plan September 2011 Version 5.0

REVISION HISTORY Page Description Date 7 Added Section 5.1 Plan Modifications 09/08/11 9 Modified Table 2 to reflect SW 47C Improvements 09/08/11 I

Table of Contents 1.0 Background... - 1-2.0 Introduction... - 1-3.0 Spillway Overview... - 1-4.0 Spillway Characteristics... - 2 - Table 1: Spillways Along The El Dorado Canal... - 4-5.0 Spillway Channels... - 2-5.1 General Practices and Maintenance Measures to Reduce Erosion and Sedimentation along Spillway Channels Figure 1: Spillways Located Along the El Dorado Canal... - 10 - Appendix A Photo Documentation - Spillway Facilities... - 12 - Appendix B Photo Documentation - Spillway Channels... - 12 - II

1.0 Background This plan is the result of a collaborative effort between the El Dorado Irrigation District (EID), Project 184 Ecological Resources Committee (ERC), USDA Forest Service (Forest Service), and the State Water Resources Control Board (SWRCB). This plan is designed in accordance with the Federal Energy Regulatory Commission (FERC) Order Issuing New License October 18, 2006, Appendix A Section 4(e) Condition No. 41 (Condition 41) and Appendix B Condition No. 10 and the Project 184 Settlement Agreement (EID 2003). Condition 41 states: Condition No. 41 Preferred Canal Drainage Structure and Release Point Plan The licensee shall, within 1 year after license issuance, file with FERC a plan approved by the FS and SWRCB after consultation with the ERC, to designate preferred canal drainage structures and release points to be used in the event of an emergency and for maintenance, that will minimize adverse impacts to water quality. The licensee shall implement the plan upon approval. 2.0 Introduction The El Dorado Canal spillways serve a critical role in protecting the integrity of the canal, promoting water supply reliability, and providing environmental protection. Water is conveyed from the El Dorado Diversion Dam (Diversion Dam) to the Powerhouse through the approximately 22 mile long El Dorado Canal (Canal), which traverses steep slopes on the south side of the South Fork American River (SFAR). The Diversion Dam is located about 1.5 miles downstream of the town of Kyburz at an elevation of about 3,911 feet above msl. The Canal discharges at the El Dorado Forebay, located just north of Pollock Pines, at an elevation of about 3,791 feet above msl. Water diverted at the El Dorado Diversion Dam takes approximately 14 hours to reach the Forebay Reservoir, making spillway releases at intervals along the Canal a critical component of project operations. This plan describes preferred canal drainage structures and release points (spillways) and is intended to establish practices that will minimize adverse impacts to water quality. Foothill yellow-legged frog flow fluctuation monitoring and reporting requirements will be conducted in accordance with the Federal Power Act, Section 4(e) Condition No. 37.3. 3.0 Spillway Overview As Canal flows are monitored by the water level alarms, the spillways, operated in conjunction with the El Dorado Diversion Dam and the tributary stream diversions, can provide the most immediate means of partially or fully dewatering the Canal. The spillways provide both active and passive capability to relieve excess water occurring during high - 1 -

inflows, to prevent high water levels as may be caused by Canal restrictions, or to prevent flows from continuing downstream due to facility maintenance and operations (e.g., powerhouse operations, downstream obstruction, etc.). The spillways can be actively controlled by removing flashboards, opening gates, and in some locations dropping a radial check gate to discharge some or all of the canal flow. In addition, with the exception of spillway 39, all spillways have passive spill capability, which allows the spillways to relieve high water over a fixed or adjustable crest of the Canal sidewall as needed. The spillways serve to convey Canal discharges into channels between the Canal and South Fork American River. With few exceptions, the spillway channels are in natural drainages which vary in composition of soil, rock and vegetation. In the interest of protecting water quality, EID has established an erosion rating as a means of ranking spillway channels used to determine spillways to be used routinely verses emergencies only. There are 30 spillways situated generally at less than one-mile intervals along the approximately 22-mile conveyance system (see Figure 1). Eleven spillways are automated and have the capacity to spill the full canal. All automated spillways have electronic systems which must be controlled by an operator either on-site or remotely. There are 22 alarms located at approximately one-mile intervals along the Canal including an alarm within the El Dorado Tunnel. The alarms operate in conjunction with electronic SCADA systems to monitor water elevations in the Canal. The alarms provide immediate warning to operators of any water level fluctuations that may require immediate attention. 4.0 Spillway Characteristics Characteristics of the spillways are summarized in Table 1 indicating the number, location, type, operation type, gate type, capacity, and channel notes. Gaps between spillway numbers result when a bypassed section of Canal was replaced with a tunnel or locations where spillways have been abandoned. Descriptions of each heading are as follows: Spillway #: Number corresponding to map. Location: Nearest identifiable feature or facility to spillway. Spillway Type: Each release point is identified as preferred, secondary, or emergency. o o o Preferred these are preferred locations used for maintenance and emergencies which have good channels and can spill the full Canal capacity. Secondary used when a preferred spillway is not located close enough to quickly relieve a Canal flow restriction. These locations have less than optimum channels and may not be capable of spilling the full Canal capacity. Emergency For emergency use only; these spillways are used only when life or property are at risk, and then, sparingly for short duration spills. These spillways generally have poor channel conditions which could cause erosion and introduce sediment into the South Fork American River. - 2 -

Operation Type: o Automated motor operated; can be operated in either Local or Remote (SCADA) control. o Manual requires operations staff to manually open or close the gate. Gate Type: With the exception of spillway 39, all of the spillways have passive spill capabilities regulated by flashboards. The four general gate types include: o Flashboards gates with stacked stop logs commonly referred to as flashboards. o Radial Check a curved gate that drops down into the Canal preventing flow further down the Canal and diverting flow into a side spillway opening. o Slide vertically moving gate which opens downward allowing flow over the top. o Sluice vertically moving gate which opens upward allowing flow beneath the gate. Capacity: The maximum spill flow in cfs when gate is open. Spill Channel Notes: The notes describe conditions of the channel that are of significance to life and property. The emergency spillways are used only as a last resort and in severe events to prevent overtopping of the Canal. The emergency spillways are used exclusively for short duration spills. For example, a complete breach of the Canal due to a large boulder, tree, or landslide in close vicinity to an emergency spillway may result in the need to release the full capacity of the Canal into an emergency spillway. Partial blockage of the Canal due to ice build-up or a small landslide, boulder or tree may also result in partial release into an emergency spillway. The emergency spillways may also be opened during extreme flood events (e.g., January 1997 flood event) to control natural flows entering the Canal. All designated emergency spillways (as described in Table 1) will be monitored for turbidity at the confluence with the South Fork American River (SFAR) after every spill over 20 cfs. Turbidity is defined by the California Regional Water Quality Control Board (RWQCB) - Central Valley Region (1998) Water Quality Control Plan (Basin Plan) or equivalent document. If turbid, the channels will be investigated to determine the source and identify measures needed to restabilize the channel. The spillway locations are shown on Figure 1 and Appendix A includes example photographs of a sluice gate, radial check gate, flashboards, manual sluice gate with wheeltype operator, passive spill, and a rock-lined channel. - 3 -

Table 1: El Dorado Canal Spillways Spillway # Milepost Location Spillway Type Operation Type Gate Type Capacity in (cfs) Spill Channel Notes 1 0 El Dorado Diversion Dam Preferred Automated Slide 165 None 2 0.5 3 1 Flume 2 Carpenter Creek Downstream Alarm 1 Preferred Manual Flashboards 100 Emergency Manual Radial Check 100 Sand Flat Campground 30 Milestone Tract residents 5 1.8 Flume 4 Preferred Manual Flashboards 100 None 7 2.5 Flume 8/9 Preferred Manual Flashboards 80 None 8 2.7 9 3.1 Upstream Flume 10 Upstream Flume 11 Emergency Manual Sluice 165 None Emergency Manual Sluice 100 None 10 3.5 Flume 13 Preferred Automated Radial Check and Slide 165 None 10A 3.7 Alder Creek Siphon House Alder Creek Preferred Manual Flashboards 120 Alder Creek Tract residents 11 4.1 Flume 20 Emergency Manual Flashboards 100 None 20 7 Flume 30 Bull Creek Preferred Automated Sluice (3) 165 Bull Creek Tract residents 20A 7.5 Alarm 10 Emergency Automated Radial Check 40 Bull Creek Tract residents 20B 7.6 22 8.3 Plum Creek Siphon Flume 39/40 Channel feeds Plum Creek Emergency Manual Flashboards 40 Bull Creek Tract Preferred Manual Flashboards 75 None - 4 -

Spillway # Milepost Location Spillway Type Operation Type Gate Type 23 8.7 Flume 41 Emergency Automated Slide Capacity in (cfs) 165 (may be used at reduced capacity) Spill Channel Notes None 25 9.8 Camp P Secondary Manual Sluice 120 Culvert under Hwy 50 27 11 Camp 3 Ogilby Creek Preferred Automated Slide and Radial Check 165 Bridal Veil Picnic Area 28 11.5 30 12 u/s Esmeralda Tunnel d/s Esmeralda Tunnel 32 13.2 Camp 4 Emergency Automated 33 13.9 35 14.7 37 16.1 39 17.1 40 17.5 d/s Flume 46A Hazel Creek Tunnel d/s Flume 47B Fresh Pond d/s Flume 47B Fresh Pond u/s Flume 47 Fresh Pond Emergency Manual Flashboards 80 Emergency Manual Sluice 80 Sluice and Radial Check 165 Emergency Manual Flashboards 80 Bridal Veil Picnic Area Bridal Veil Falls & Picnic Area Pacific House tract water system Pacific House tract water system Emergency Manual Radial Check 80 None Preferred Automated Radial Check 165 None Emergency Manual Gate - blocked out 80 None Emergency Manual Sluice 80 None 42 18.4 Flume 48 Preferred Automated Radial Check and Slide 165 None 44 19.2 Flume 49/50 Preferred Automated Slide 165 None - 5 -

Spillway # Milepost Location Spillway Type Operation Type Gate Type Capacity in (cfs) 45 19.9 d/s Flume 52 Secondary Manual Sluice 100 46 20.6 Bullion Bend Secondary Manual Sluice 80 47C 21.4 Flume 52A Emergency (To be used only in extreme emergency until channel upgrades are completed; at which time, it is anticipated the spillway will be operated as Preferred) Automated Radial Check 165 Spill Channel Notes Houses below Houses below Culvert under Randolph Canyon Rd. - 6 -

5.0 Spillway Channels 5.0 Spillway Channels As part of in-field sub-committee meetings held during the summer of 2007, each of the channels listed in Table 2 were examined to identify improvements to minimize potential erosion associated with spillway operation and establish timetables for those improvements. Some descriptions of existing conditions are based on field investigations of the Project 184 spillway channels conducted by Richard Harris Ph. D. and summarized in the report entitled Emergency Spill Management. Where appropriate, Table 2 also describes the interim guidelines for use until channel improvements are completed. Appendix B includes representative photographs of the spillway channels. 5.1 Plan Modifications After assessment of the improvements initially contemplated in the Plan for Spillways 11 and 47C, the District has subsequently identified improvements different than those contemplated in the Plan. A description of each modification is provided below and incorporated into Table 2. Spillway 11 Staff has evaluated the site and determined that some of the dead trees have fallen on their own and those that remain standing would be hazardous to fall manually. Therefore, the Plan modification is to allow the remaining dead trees to fall on their own accord over time. This approach meets the objective of the trees falling into the spill channel to slow water and trap sediment. Spillway 47C After improvements (discussed below) to SW 46 are complete, SW 47C will no longer be necessary and thereafter decommissioned, including removal of the spillway box chute, slide gates, stop logs, radial gate and associated building and controls. Implementation of these measures remove the spillway eliminating potential water quality impacts associated with continued operation of SW 47C. Spillway 46 The improvements to SW 46 include increasing the spill capacity to be able to convey 160 cfs and automation to allow remote operation of the spillway. SW 46 releases into Randolph Creek, therefore, improvements also include stabilizing the spillway channel and approximately 150 linear feet of Randolph Creek to accommodate increased flow from the spillway. - 7 -

Table 2. Overview of Spillway Channel Improvements Spillway Number Existing Conditions Identified Improvements Priority Rating 3 Some unstable banks. 10 Well vegetated channel that is in good condition. 11 Well vegetated channel with some bank erosion. Numerous snags (cut off at top) are located near spillway channel. 20 A/B Unstable banks, bank sloughing and caving. Wooden box flume outlet needs to be replaced. Interim Guidelines 2 Passive spill only not-to exceed 20 cfs. None N/A N/A Allow snags (standing dead trees) located within striking distance of the spillway channel to fall on their own accord into the existing channel to slow water and trap sediment. Repair gabion located near confluence with SFAR and install two rocks dams (roughly 18 inches high) upstream at even intervals along the channel to slow water and trap sediment. Appendix B Photo Reference Photo B1 and B2 N/A None Photo B3 and B4 2 Passive spill only not-to exceed 40 cfs. Photo B5 23 Well vegetated channel on steep slope. Bedrock substrate with small boulders and cobbles. Monitor for turbidity* at confluence with SFAR after every spill over 20 cfs and, if turbid, investigate channel as described on page 3 for all emergency spillways. N/A N/A Photo B6 27 Good channel, well vegetated. None N/A N/A Photo B7 32 Intermittent channel with bedrock substrate. Infrequent use of spillway channel; used roughly every 10 years. 33 Bedrock and boulder substrate. Infrequent use of spillway channel; Monitor for turbidity at confluence with SFAR after every spill over 20 cfs and, if turbid, investigate channel as described on page 3 for all emergency spillways. Monitor for turbidity at confluence with SFAR after every spill over 20 cfs and, if turbid, N/A N/A Photo B8 N/A N/A Photo B9-8 -

Spillway Number Existing Conditions used roughly every 10 years. 37 Bedrock substrate. Infrequent use of spillway channel; used roughly every 10 years. 47C Massive erosion and unstable banks. Identified Improvements investigate channel as described on page 3 for all emergency spillways. Monitor for turbidity at confluence with SFAR after every spill over 20 cfs and, if turbid, investigate channel as described on page 3 for all emergency spillways. Decommissioned by removing remote capabilities and remove the box chute, slide gates, stop logs, radial gate, and Priority Rating Interim Guidelines Appendix B Photo Reference N/A N/A Photo B10 1 No passive spill. Use in extreme and unprecedented emergency only. associated buildings. Priority 1 = Scheduled to be completed within the next 5 years (December 2012) Priority 2 = Scheduled to be completed within the next 10 years (December 2017) *Turbidity - as defined by the California RWQCB Basin Plan (1998) or equivalent document. Photo B11 and B12 5.2 General Practices and Maintenance Measures to Reduce Erosion and Sedimentation along Spillway Channels The following measures, on a case-by-case basis, may be incorporated into ongoing project operations and maintenance activities in order to minimize scour and erosion along spillway channels: Where appropriate, fall snags (standing dead trees) and hazard trees into spillway channels perpendicular to flow. Where appropriate, install small (roughly 18 inches high) loose rock dams in channel. If logs are diverting erosive flow into stream banks and causing scour, buck up logs and re-position in the channel to remove pressure from vulnerable stream banks. - 9 -

References California Regional Water Quality Control Board Central Valley Region. 1998. Fourth Edition of the Water Quality Control Plan (Basin Plan). El Dorado Irrigation District. 1999. Emergency Spill Management. Prepared by Richard Harris, Ph.D. (on file). El Dorado Irrigation District. 2003. El Dorado Project FERC Project No. 184. El Dorado Relicensing Settlement Agreement. - 10 -

Figure 1: Spillways Located Along the El Dorado Canal (see next page) - 11 -

Appendix A: Photo Documentation Spillway Facilities Photo A1 Example Passive Spillway with Canal Level Controlled by Flashboards Photo A2 Example Radial Check Gate in Open Position - 12 -

Photo A3 Example Sluice Gate Photo A4 Example Manual Sluice Gate with Wheel-Type Operator - 13 -

Photo A5 Example Passive Spill Photo A6 Example Rock-Lined Spill Channel - 14 -

Appendix B: Photo Documentation Spillway Channels Photo B1 Spillway 3 Channel Photo B2 Wooden Box Outlet at Spillway 3-15 -

Photo B3 Spillway 11 Outlet and Channel Photo B4 Spillway 11 Channel with Snags - 16 -

Gabion Photo B5 Spillway 20 A/B Gabion (sediment trap) Photo B6 Spillway 23 Alluvial Fan Deposit at South Fork American River - 17 -

Photo B7 Spillway 27 Channel Photo B8 Spillway 32 Outlet and Channel - 18 -

Photo B9 Spillway 33 Outlet and Channel Photo B10 Spillway 37 Downstream Channel near Freshpond - 19 -

Photo B11 Spillway 47c Wooden Spillway Outlet Photo B12 Spillway 47c Headcut/Erosion - 20 -

20120217-0009 FERC PDF (Unofficial) 02/16/2012 FEDERAL ENERGY REGULATORY COMMISSION Washington, D. C. 20426 OFFICE OF ENERGY FROIKCIS Mr. Brian Mueller EI Dorado Irrigation District 2890 Mosquito Road Placerville, CA 95667 Project No. 184-151 California El Dorado Hydroelectric Project El Dorado Irrigation District February 16, 2012 Re: Revised Canal Drainage Structure and Release Plan Dear Mr. Mueller: This is in reference to your revised Canal Drainage Structure and Release Plan, filed with the Federal Energy Regulatory (Commission) on January 30, 2012, for the El Dorado Hydroelectric Project No. 184. You also filed documentation of U.S.Forest Service (FS) approval of the revised plan on February 14, 2012. Ordering paragraphs (D) and (E) of the project license' require compliance with the California State Water Resources Control Board's (State Water Board) water quality certification and the FS Section 4(e) Conditions, respectively. Condition No. 10 of the water quality certification and FS 4(e) Condition No. 41 require that you develop a Canal Drainage Structure and Release Plan to designate preferred canal drainage structures and release points to be used in the event of an emergency and for maintenance that will minimize adverse effects to water quality. The plan is to be developed in consultation with both agencies and filed with the Commission upon resource agency approval. You originally filed the plan with the Commission on April 17, 2008, which was subsequently accepted by Commission letter dated May 8, 2008. In your January 30, 2012 letter, you explain that some of the proposed canal improvements in the original plan need to be modified, including: tree management at spillway 11;various improvements to spillway 46; and decommissioning of spillway 47C. You developed these modifications in consultation with the project Ecological Resources Committee, including the State Water Board and FS. The State Water Board and FS formally approved your modified plan by letters dated September 9, 2011, and February 7, 2012, respectively. Review of your revised plan indicates that it adequately meets the requirements of the project license. ' See 117FERC $ 62,044. Order Issuing New License (issued October 18, 2006).

20120217-0009 FERC PDF (Unofficial) 02/16/2012 Project No. 184-151 -2- We note that your proposal to modify spillway 46 was submitted to the Regional Engineer of the Commission's San Francisco Regional Office on January 6, 2012. Please note that your proposal to decommission spillway 47C should also be coordinated with the San Francisco Regional Engineer, pursuant to 18 CFR $12.11. Thank you for your cooperation. Ifyou have any questions regarding this matter, please contact Mr. John Aedo at (415) 369-3335. Sincerely, Chief, Aquatic Resources Branch Division of Hydropower Administration and Compliance

20120217-0009 FERC PDF (Unofficial) 02/16/2012 Document Content(s) 12894896.tif...1-2