GLOBALFOUNDRIES U.S. INC. Air Dispersion Modeling - FAB 8 Campus C.T. Male Project No.:

Similar documents
Iowa Exceedances of the National Ambient Air Quality Standards, 2013 (Reported Through October 8 th ) Iowa DNR Ambient Air Monitoring Group

PLANT OPERATIONS AND TECHNOLOGY I & II: REAL TIME FURNACE AIR IN- LEAKAGE MONITORING ON COAL, OIL AND/OR GAS FIRED BOILERS

Use of Equivalent Building Dimensions (EBD) to Characterize Upwind Terrain Wake Effects for AERMOD

Gas Turbine Performance Analysis

Discovery HP-TGA 75/750. Site Preparation Guide

ENVIRONMENTAL AND POLLUTANTS GAS ANALYZERS

White Paper. Chemical Sensor vs NDIR - Overview: NDIR Technology:

AIR QUALITY MANAGEMENT IN KWINANA FACT SHEET ON. Sulphur Dioxide ENVIRONMENT COMMUNITY INDUSTRY

Appendix E Air Quality Technical Report

MATERIAL SAFETY DATA SHEET

analytical bulk flow distance FLOW level pressure temperature industrial communication

ISO Respiratory Protective Device Standards

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

Page: 1 Rev. Date 08/07/97 GENERIC SPUNBOND FABRIC (NO SURFACTANT) ESAPCO, 1395 JOHN FITCH BLVD, SOUTH WINDSOR, CT, 06074,

acrolein, acetaldehyde and acetone( cm -1 ); methanol (1306 cm -1 ); ethylene (949 cm -1 ); and isoprene (893 cm -1 ).

Graphics of annual values NABEL

Emission Inventory Evaluation Using DISCOVER-AQ Aircraft Data

EMISSION SURVEY FOR SONAE NOVOBORD: WHITE RIVER. Report No. 565/12 FR.1. March 2013 C & M CONSULTING ENGINEERS PO BOX LYNNWOOD RIDGE 0040

Fryderyk Chopin. Team: Bartosz Kawecki Naglis Kazakevičius Pauline Plötz Helena Sałasinska Dariia Zakharchenko Michelle Zuischko

Properties of Gases Observing Atom Pressure of a Gas Measuring Gas Products of Chemical Inferring Molecule Reactions

Our Air- Why We Should Care!

CCR Fugitive Dust Control Plan

Generalized Pressure Drop Correlation

Experiment AMe-1: Small Animal Respiratory Exchange Ratio (RER)

Examination of uncertainty in heat rate determinations

LK-SX CO 2 +VOC. Application. Security Advice Caution. Notes on Disposal

EMERGENCY PHONE: or (651) (24 hours)

Gas monitoring using GASMET FTIR

High Efficiency SO2 Scrubber Design to Reduce Caustic Consumption

MATERIAL SAFETY DATA SHEET

Phosgene Sensor. Sensoric COCl2 3E 1

Safety Data Sheet CPS IC163 Colorado Photopolymer Solutions, LLC Reviewed on 8/22/18

Overview: Curriculum Goals: Materials: Explore:

MATERIAL SAFETY DATA SHEET

Reduce Turnaround Duration by Eliminating H 2 S from Flare Gas Utilizing VaporLock Scrubber Technology

Respiratory Protective Equipment

The Influence Of The Burning Process At The Thermoelectric Power Station On Ecology And The Ways Of Reducing The Harmful Wastes Into The Atmosphere

MATERIAL SAFETY DATA SHEET Date Printed: 09/26/20012 Date Updated: 01/29/2012 Version 1.4. Substance Name CAS # SARA 313 ACID FUCHSIN No

HiQ laboratory gas generators.

Material Safety Data Sheet

Gas Furnaces 95AF. Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited. 95% AFUE 44,000 to 110,000 Btuh Input 2 to 5 Tons Add-On Cooling

Trace Environmental Systems

MATERIAL SAFETY DATA SHEET

COAL COMBUSTION RESIDUAL (CCR) FUGITIVE DUST CONTROL PLAN

Part 70 Operating Permit Amendment

Exhaust Scrubbers. What you need to know. Move Forward with Confidence

Material Safety Data Sheet FleeceBack Membrane

DEPARTMENT OF ENVIRONMENTAL PROTECTION Air Quality. 35 P.S. Sec (Air Pollution Control Act) and Act 95 (75 PA C.S.

METHOD 3A - DETERMINATION OF OXYGEN AND CARBON DIOXIDE CONCENTRATIONS IN EMISSIONS FROM STATIONARY SOURCES (INSTRUMENTAL ANALYZER PROCEDURE)

NZQA unit standard 7145 version 9 Page 1 of 5. Design and maintain effective ventilation systems for an underground coal mine

2018 National Metal and Nonmetal Mine Rescue Contest. Mine Rescue Field Competition Written Test. Good Luck!

METHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER

At the end of this lesson, you will be able to do the following:

Intended Use of Product: For R&D materials science use only, not intended for drug or household use.

BASF s Mercury Sorbent HX A Mercury MATS Compliant Technology William Hizny, Fabien Rioult PhD, Xiaolin Yang PhD

Appendix F1 AIR QUALITY IMPACT ANALYSIS

SUBSTATION MAINTENANCE ELECTRICAL OPERATING PROCEDURE

Date Printed: 06/13/2008 Date Updated: 01/30/2006 Version 1.4. Product Name CHROMOTROPE 2R (C.I ) Product Number

Re-Tek SAFETY DATA SHEET

PRODUCT CAS NUMBER % BY WEIGHT 2-Methyl-1,3-Propanediol %

All Multi-Tech Non-Phthalate Color Inks MATERIAL SAFETY DATA SHEET

Instrumental Technique GAS CYLINDER

MATERIAL SAFETY DATA SHEET (SEETEC EVA)

Public Opinion, Traffic Performance, the Environment, and Safety After Construction of Double-Lane Roundabouts

Understanding Hydrated Lime Properties In Acid Gas Control

MATERIAL SAFETY DATA SHEET

MONITORING & MEASURING EQUIPMENT FOR EMISSION MONITOR, HAZARD DETECTION & ENERGY OPTIMIZATION VERSION 1. 2

MATERIAL SAFETY DATA SHEET HYALIS - 1% Hyaluronate Refining Serum

Off-gassing from III-V Wafer Processing -- A Collaboration of SEMATECH and IMEC

PROPYLENE HEATING, BRAZING & WELDING

MATERIAL SAFETY DATA SHEET

BICYCLE INFRASTRUCTURE COMPONENT REMOVE II PROGRAM GUIDELINES, POLICIES, AND PROCEDURES

Technical Data Sheet MF010-O-LC

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD)

Safety Data Sheet 1. PRODUCT AND COMPANY IDENTIFICATION 2. HAZARDS IDENTIFICATION. Product Identification Product Name: Everkote 300

EFFECTIVE DESIGN OF CONVERTER HOODS. 111 Ferguson Ct. Suite 103 Irving, Texas U.S.A. 400 Carlingview Dr. Toronto, ON M9W 5X9 Canada.

Safety Data Sheet (SDS) Revision / Review Date: 3/11/14

SAFETY DATA SHEETS. This SDS packet was issued with item:

SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT METHOD INSTRUMENTAL ANALYZER PROCEDURES FOR CONTINUOUS GASEOUS EMISSION SAMPLING

Monterey Bay Unified Air Pollution Control District Silver Cloud Court, Monterey, CA 93940

CHAPTER 3 : AIR COMPRESSOR

Gas Furnaces 95AF2V. Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited

Case 12 Multistage Centrifugal Refrigeration System Halocarbon Refrigerant

NOTICE OF AVAILABILITY FOR PUBLIC REVIEW AND COMMENT 2011 AIR MONITORING NETWORK PLAN

MONITORING & MEASURING EQUIPMENT FOR EMISSION MONITOR, HAZARD DETECTION & ENERGY OPTIMIZATION VERSION 1. 3

Tunnelling. Design Element Health Hazard Considerations Possible Solutions Linked to Ref No.

Indiana Electricity Projections and Renewable Energy

Safety Data Sheet. Lithium bis(pentafluoroethylsulfonyl)imide 1 IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND THE COMPANY/UNDERTAKING

14 FORTUNE DRIVE PRODUCT NAME: EPO-TEK H74 UNF, Part A BILLERICA, MA 01821

MATERIAL SAFETY DATA SHEET

Because every life has a purpose. MSA Z GARD S Sensor Calibration Procedure

Gas-Detection Instruments

MATERIAL SAFETY DATA SHEET

Carcinogen: NTP (No) IARC (No) OSHA (No) DATE REVISED: 6/5/01 REV: A * HMIS CODE ratings are estimated by Epoxy Technology.

Date Printed: 03/22/2007 Date Updated: 09/07/2006 Version 1.8

SAFETY DATA SHEET INDUSTRIAL EP COMPOUND HEAVY DUTY GEAR LUBRICANTS Revision Date:

SAFETY DATA SHEET Isopropyl Alcohol 70% Product Number: 32

Safety data sheet MICRO AIR Revision date : 2009/05/20 Page: 1/6

Material Safety Data Sheet

The table shows the effect of exercise on the action of one person s heart. Heart rate in beats per minute

Transcription:

C.T. Male Associates GLOBALFOUNDRIES U.S. INC. Air Dispersion Modeling - FAB 8 Campus C.T. Male Project No.: 11.1114 AIR DISPERSION MODELING RESULTS COMPARISON TO NATIONAL AMBIENT AIR QUALITY STANDARDS (NAAQS) and 6 NYCRR PART 257-8 USING AERMOD SOFTWARE (METEOROLOGICAL DATA 2004-2008) Summary of Air Modeling Results Model Maximum Background Total CAS No. Chemical Name Run ID Concentration Concentration Concentration Standard % of Total (ug/m 3 ) (ug/m 3 ) (ug/m 3 ) (ug/m 3 ) Time Period 00630-08-0 Carbon Monoxide (CO) CO - Run #01 169.49 1,495.00 1,664.5 40,000 1-Hour 4.161 00630-08-0 Carbon Monoxide (CO) CO - Run #01 64.162 1,150.00 1,214.16 10,000 8-Hour 12.142 NY075-02-5 Particulate Matter (PM 2.5 )* PM Run #01 5.588 23.000 28.59 35 24-Hour 81.679 NY075-02-5 Particulate Matter (PM 2.5 ) PM Run #02 2.331 8.300 10.63 12 Annual Hourly 88.596 07446-09-5 Sulfur Dioxide (SO 2 )** SO 2 Run #01 5.803 40.610 46.41 196.5 1-Hour 23.620 07446-09-5 Sulfur Dioxide (SO 2 ) SO 2 Run #02 5.256 33.536 38.79 1,310 3-Hour (Secondary) 2.961 10102-44-0 Nitrogen Dioxide (NO 2 )*** 1 NO 2 Run #01 83.397 82.72 166.1 188 1-Hour 88.360 10102-44-0 Nitrogen Dioxide (NO 2 ) 1 NO 2 Run #02 4.434 15.6416 20.08 99.64 Annual Hourly 20.148 N/A Fluorides MC Run #01 2.452 N/A 2.45 3.70 12-Hour 66.273 N/A Fluorides MC Run #01 1.814 N/A 1.81 2.85 24-Hour 63.649 N/A Fluorides MC Run #01 0.790 N/A 0.79 0.820 1-Month 96.322 * - 3 Year Average of 98th Percentile of 24 Hour Concentrations ** - 3 Year Average of 99th Percentile of Daily Max. 1 Hour Average *** - 3 Year Average of 98th Percentile of Daily Max. 1 Hour Average Nitrogen Oxide Background Level Based on NYSDEC 2011 data for Amherst, NY (NYSDEC Region 9) Carbon Monoxide Background Levels Based on NYSDEC 2011 data for Loudonville, NY (NYSDEC Region 4) Sulfur Dioxide Background Levels Based on NYSDEC 2011 data for Schenectady, NY (NYSDEC Region 4) PM 2.5 Background Levels Based on NYSDEC 2011 Data for Albany County, NY (NYSDEC Region 4) 1-1-Hour NO X value derived by applying 80% NO 2 /NO X Ratio to NO X modeling result Revised 4/5/2013 Page 1 of 30

C.T. Male Associates GLOBALFOUNDRIES U.S. INC. Air Dispersion Modeling - FAB 8 Campus C.T. Male Project No.: 11.1114 Summary of Model Inputs Particulate Matter (PM 2.5 ) - Model Run #2 File Name: PM02 Output: Annual Concentration Data Boiler Testing Summary: 12 hours per year combusting No. 2 Fuel Oil Boiler Operation Summary: 65% Load for all boilers (while burning natural gas) Generator Testing Summary: 38 hours per year per unit Stack Heights for 8.1 Boilers = 33'; Stacks for Admin Building 2 Boilers = 33'; Stacks for TDC Boilers = 93'; Stacks for TDC Boilers = 125' Max. Annual Result: 2.331 ug/m 3 Annual Hour Standard = 12 ug/m 3 Background Conc. = 8.3 ug/m 3 (2011 NYSDEC Data for Albany County) Total Concentration = 10.63146 88.60% of standard Emission Stack Height Stack Diameter Temperature Flow Rate Velocity Emission Rate Exhaust Type Point # ft m in ft (F) (C) (CFM) (FPS) (lb/hr) Fab 8.1-1 Oxidizer 96 29.261 52 4.33 115 46.11 42,000 47.464 0.021 Fab 8.1-2 Oxidizer 96 29.261 52 4.33 115 46.11 42,000 47.464 0.021 Fab 8.1-3 Caustic Scrubber 96 29.261 52 4.33 72 22.22 42,500 48.029 0 Fab 8.1-4 Caustic Scrubber 96 29.261 52 4.33 72 22.22 42,500 48.029 0 Fab 8.1-5 Caustic Scrubber 96 29.261 52 4.33 72 22.22 42,500 48.029 0 Fab 8.1-6 Acid Scrubber 96 29.261 60 5.00 72 22.22 62,000 52.627 0.0063 Fab 8.1-7 Acid Scrubber 96 29.261 60 5.00 72 22.22 62,000 52.627 0.0063 Fab 8.1-8 Acid Scrubber 96 29.261 60 5.00 72 22.22 62,000 52.627 0.0063 Fab 8.1-9 Acid Scrubber 96 29.261 60 5.00 72 22.22 62,000 52.627 0.0063 Fab 8.1-10 Acid Scrubber 96 29.261 60 5.00 72 22.22 62,000 52.627 0.0063 Fab 8.1-11 Acid Scrubber 96 29.261 60 5.00 72 22.22 62,000 52.627 0.0063 Fab 8.1-11A Acid Scrubber 96 29.261 60 5.00 72 22.22 62,000 52.627 0.0063 Fab 8.1-24 Acid Scrubber 96 29.261 60 5.00 72 22.22 62,000 52.627 0.0063 Fab 8.1-25 Acid Scrubber 96 29.261 60 5.00 72 22.22 62,000 52.627 0.0063 Fab 8.1-26 Acid Scrubber 96 29.261 60 5.00 72 22.22 62,000 52.627 0.0063 Fab 8.1-27 Acid Scrubber 96 29.261 60 5.00 72 22.22 62,000 52.627 0.0063 Fab 8.1-28 Caustic Scrubber 96 29.261 42 3.50 72 22.22 28,000 48.504 0 Fab 8.1-29 Caustic Scrubber 96 29.261 42 3.50 72 22.22 28,000 48.504 0 Fab 8.1-30 Caustic Scrubber 96 29.261 42 3.50 72 22.22 28,000 48.504 0 Fab 8.1-111 RCTO/Fan Stack 96 29.261 42 3.50 115 46.11 28,000 48.504 0.021 Fab 8.1-112 RCTO/Fan Stack 96 29.261 42 3.50 115 46.11 28,000 48.504 0 Fab 8.1-113 RCTO/Fan Stack 96 29.261 42 3.50 115 46.11 28,000 48.504 0 Fab 8.1-114 Oxidizer 96 29.261 18 1.50 554 290.00 3,000 28.294 0 Fab 8.1-115 Oxidizer 96 29.261 18 1.50 554 290.00 3,000 28.294 0 Fab 8.1-58 Dual Fuel Boiler 33 10.058 40 3.33 400 204.44 11,425 21.820 0.289 Fab 8.1-59 Nat. Gas Boiler 33 10.058 40 3.33 400 204.44 11,425 21.820 0.289 Fab 8.1-63 Dual Fuel Boiler 33 10.058 40 3.33 400 204.44 11,425 21.820 0.289 Fab 8.1-64 Nat. Gas Boiler 33 10.058 28 2.33 400 204.44 4,896 19.085 0.124 Fab 8.1-66 Nat. Gas Boiler 33 10.058 28 2.33 400 204.44 4,896 19.085 0.122 Fab 8.1-67 Dual Fuel Boiler 33 10.058 40 3.33 400 204.44 9,793 18.703 0.245 Revised 4/5/2013 Page 28 of 30

C.T. Male Associates GLOBALFOUNDRIES U.S. INC. Air Dispersion Modeling - FAB 8 Campus C.T. Male Project No.: 11.1114 Summary of Model Inputs Emission Stack Height Stack Diameter Temperature Flow Rate Velocity Emission Rate Exhaust Type Point # ft m in ft (F) (C) (CFM) (FPS) (lb/hr) Fab 8.1-88 Oxidizer 96 29.261 52 4.33 115 46.11 42,000 47.464 0 Admin 2-B1 Nat. Gas Boiler 33 10.058 20 1.67 400 204.44 1,991 15.208 0.050 Admin 2-B2 Nat. Gas Boiler 33 10.058 20 1.67 400 204.44 1,991 15.208 0.050 Admin 2-B3 Nat. Gas Boiler 33 10.058 20 1.67 400 204.44 1,991 15.208 0.050 ESB-12 Gens Emergency Generators 33 10.058 18 1.50 815 435.00 15,100 142.41 0.0014 101 Nat. Gas Boiler 93 28.346 8 0.67 190 87.78 457 21.820 0.011 102 Nat. Gas Boiler 93 28.346 8 0.67 190 87.78 457 21.820 0.011 103 Nat. Gas Boiler 93 28.346 8 0.67 190 87.78 457 21.820 0.011 104 Dual Fuel Boiler 93 28.346 42 3.50 268 131.11 9,793 16.964 0.244 105 Dual Fuel Boiler 93 28.346 42 3.50 268 131.11 9,793 16.964 0.244 106 Nat. Gas Boiler 93 28.346 42 3.50 268 131.11 11,751 20.357 0.291 107 Nat. Gas Boiler 93 28.346 42 3.50 268 131.11 11,751 20.357 0.292 108 Nat. Gas Boiler 93 28.346 42 3.50 268 131.11 11,751 20.357 0.292 109 Nat. Gas Boiler 93 28.346 42 3.50 268 131.11 11,751 20.357 0.292 TDC-121 Caustic Scrubber 110 33.528 20 1.67 72 22.22 6,000 45.837 0 TDC-122 Caustic Scrubber 110 33.528 20 1.67 72 22.22 6,000 45.837 0 TDC-123 Caustic Scrubber 110 33.528 20 1.67 72 22.22 6,000 45.837 0 ESB2-12 Gens Emergency Generators 38 11.582 18 1.50 815 435.00 15,100 142.414 0.0014 TDC-124 POU - Acid Scrubber 110 33.528 50 4.17 72 22.22 39,000 47.670 0.0057 TDC-125 POU - Acid Scrubber 110 33.528 50 4.17 72 22.22 39,000 47.670 0.0057 TDC-126 POU - Acid Scrubber 110 33.528 50 4.17 72 22.22 39,000 47.670 0 TDC-127 POU - Acid Scrubber 110 33.528 50 4.17 72 22.22 39,000 47.670 0 TDC-118 Oxidizer 110 33.528 36 3.00 115 46.11 24,000 56.588 0.0046 TDC-119 Oxidizer 110 33.528 36 3.00 115 46.11 24,000 56.588 0.0046 TDC-120 Oxidizer 110 33.528 36 3.00 115 46.11 24,000 56.588 0 Fab 8.2-1 Acid Scrubber 125 38.100 60 5.00 72 22.22 61,111 51.873 0.0131 Fab 8.2-2 Acid Scrubber 125 38.100 60 5.00 72 22.22 61,111 51.873 0.0131 Fab 8.2-3 Acid Scrubber 125 38.100 60 5.00 72 22.22 61,111 51.873 0.0131 Fab 8.2-4 Acid Scrubber 125 38.100 60 5.00 72 22.22 61,111 51.873 0.0131 Fab 8.2-5 Acid Scrubber 125 38.100 60 5.00 72 22.22 61,111 51.873 0.0131 Fab 8.2-6 Acid Scrubber 125 38.100 60 5.00 72 22.22 61,111 51.873 0.0131 Fab 8.2-7 Acid Scrubber 125 38.100 60 5.00 72 22.22 61,111 51.873 0.0131 Fab 8.2-8 Acid Scrubber 125 38.100 60 5.00 72 22.22 61,111 51.873 0.0131 Fab 8.2-9 Acid Scrubber 125 38.100 60 5.00 72 22.22 61,111 51.873 0.0131 Fab 8.2-10 Acid Scrubber (n+1) 125 38.100 60 5.00 72 22.22 62,000 52.627 0 Fab 8.2-11 Caustic Scrubber 125 38.100 42 3.50 72 22.22 27,600 47.811 0 Fab 8.2-12 Caustic Scrubber 125 38.100 42 3.50 72 22.22 27,600 47.811 0 Fab 8.2-13 Caustic Scrubber 125 38.100 42 3.50 72 22.22 27,600 47.811 0 Fab 8.2-14 Caustic Scrubber 125 38.100 42 3.50 72 22.22 27,600 47.811 0 Revised 4/5/2013 Page 28 of 30

C.T. Male Associates GLOBALFOUNDRIES U.S. INC. Air Dispersion Modeling - FAB 8 Campus C.T. Male Project No.: 11.1114 Summary of Model Inputs Emission Stack Height Stack Diameter Temperature Flow Rate Velocity Emission Rate Exhaust Type Point # ft m in ft (F) (C) (CFM) (FPS) (lb/hr) Fab 8.2-15 Caustic Scrubber 125 38.100 42 3.50 72 22.22 27,600 47.811 0 Fab 8.2-16 Caustic Scrubber 125 38.100 42 3.50 72 22.22 28,000 48.504 0 Fab 8.2-17 Oxidizer 125 38.100 52 4.33 115 46.11 37,800 42.718 0.01945 Fab 8.2-18 Oxidizer 125 38.100 52 4.33 115 46.11 37,800 42.718 0.01945 Fab 8.2-19 Oxidizer 125 38.100 52 4.33 115 46.11 37,800 42.718 0.01945 Fab 8.2-20 Oxidizer 125 38.100 52 4.33 115 46.11 37,800 42.718 0.01945 Fab 8.2-21 Oxidizer 125 38.100 52 4.33 115 46.11 37,800 42.718 0.01945 Fab 8.2-22 Oxidizer 125 38.100 52 4.33 115 46.11 42,000 47.464 0 Fab 8.2-23 Dual Fuel Boiler (1500 hp) 125 38.100 42 3.50 268 131.1 9,793 16.964 0.244 Fab 8.2-24 Dual Fuel Boiler (1500 hp) 125 38.100 42 3.50 268 131.1 9,793 16.964 0.244 Fab 8.2-25 Dual Fuel Boiler (1500 hp) 125 38.100 42 3.50 268 131.1 9,793 16.964 0.244 Fab 8.2-26 Nat. Gas Boiler (1800 hp) 125 38.100 42 3.50 268 131.1 11,751 20.356 0.292 Fab 8.2-27 Nat. Gas Boiler (1800 hp) 125 38.100 42 3.50 268 131.1 11,751 20.356 0.292 Fab 8.2-28 Nat. Gas Boiler (750 hp) 125 38.100 28 2.33 268 131.1 4,896 19.083 0.122 Fab 8.2-29 Nat. Gas Boiler (100 hp) 125 38.100 8 0.67 190 87.78 457 21.820 0.0162 Fab 8.2 15 Gens Emergency Generators 125 38.100 18 1.50 815 435.0 15,100 142.414 0.0014 Revised 4/5/2013 Page 28 of 30