Declaration of Conformity In Accordance with ANSI/ISEA

Similar documents
Declaration of Conformity In Accordance with ANSI/ISEA

Declaration of Conformity In Accordance with ANSI/ISEA

ARC FLASH PROTECTION AT HEIGHTS

New ANSI Fall Protection Standards

Fall Protection. ANSI-What is it, Why is it important? Craig Firl. March 5 th, Company Private

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z (R2002)

Position control Constant torque. Maximum 0.5 (.02) Axial. Radial. Hinge centerline 9±0.1 (.354±.004) Part Number

If you have any questions concerning this report, please feel free to contact me. REPORT OF LABORATORY ANALYSIS

Demand Responsive Lighting Control Acceptance Document (Page 1 of 5)

ATEX, IECEx and MET (Class I, Division 1) Safety Instructions icam502

Contact person Date Reference Page Michael Lindblad F025843A 1 (1) Sustainable Built Environment

CATALOG SUPPLEMENT

IPSWICH & SUFFOLK YOUTH FOOTBALL LEAGUE - RULES Revised 27 June 2016

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Trading Application Form

SEI Certification Program Manual

Region: USA Language: EN Number : TB0031 Revision : B. Total Page: 3 Page n : 1 First Issue: 10/2014 Rev. Date: 10/08/2014

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SUMMARY STEPS TO CERTIFY ACOUSTIC DUCT SILENCER PERFORMANCE UNDER AMCA INTERNATIONAL S CERTIFIED RATINGS PROGRAM

CTAG:b9927e36a4b3f34a9138ce0bb2426b22 Certificate of Calibration

56 LESLIE HOUGH WAY SALFORD GREATER MANCHESTER M6 6AJ UNITED KINGDOM. Tel: +44 (0) Fax: +44 (0)

Service Bulletin

PHOENIX, AZ USA

SUMMARY STEPS TO CERTIFY AIRFLOW MEASUREMENT PERFORMANCE UNDER AMCA INTERNATIONAL S CERTIFIED RATINGS PROGRAM

Deadweight Trolley. Deadweight

SIERRA-SACRAMENTO VALLEY EMS AGENCY PROGRAM POLICY REFERENCE NO. 474

Service Bulletin

Supersedes: The copy of this document located on Measurement Canada s website is considered to be the controlled copy.

ENGINEERING TECHNICAL REPORT

PEM-EX-C. Figure: PEM-EX-C*A*G. ka054000en; Rev. 2.7 J

Vaisala Pressure, RH & Temp. Transmitter. The instrument was operational upon receipt. The instrument was adjusted and calibrated.

2017 and 2018 Updates to crane regulations and industry standards

It s not like other pressure gauges

BS EN ISO : 1999

ISO INTERNATIONAL STANDARD. Personal protective equipment for protection against falls from a height Single-point anchor devices

Title: INSTRUMENT AND EQUIPMENT DOCUMENTATION AND RECORDS

Series 101/121 Differential Pressure Switches

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

CTAG:e43bda4f8e48714fbb aefb192 Certificate of Calibration

IAC WORKMAN 30FT SELF RETRACTING LANYARD

SUMMARY STEPS TO CERTIFY FAN PERFORMANCE UNDER AMCA INTERNATIONAL S CERTIFIED RATINGS PROGRAM

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

GUIDANCE FOR THE APPLICATION OF EQUIPMENT CALIBRATION AND TRACEABILITY OF MEASUREMENTS ON INSPECTION BODIES

Title: The Air Leakage Performance of Timber Doorsets fitted with NOR710 Series Smoke Seals in Accordance with BS 476: Part 31, Section 31.

TEST REPORT. ACCORDING TO IES LM For. Samsung Electronics Co., LTD. 1,Samsung-Ro,Giheung-Gu,Yongin-City,Gyeonggi-Do 17113, Korea

Guide to using and filling out Club or Team or Player Registration Forms

Self-Certification Documentation

CALIBRATION SERVICES HUMIDITY DEW POINT AIR VELOCITY MASS FLOW TEMPERATURE CO 2 PRESSURE. (+34)

Sept 23, 2014 LAB MANUAL

LEAP CO 2 Laboratory CO 2 mixtures test facility

Club Sustainability Award Season 2018/19

Limpet Test Specification 001:2009 Summary

,!! ~~ Testing Procedure ~/'L

Safe transport of radioactive materials Leakage testing on packages

Team : Colchester. Gladiators. Team ID : Game Status: Team : Colchester. Gladiators. Team ID : Game Status: Team : Colchester

Club TO APPLY. to become a

UMA Drawing Number ST B EMI GROUND TEST PROCEDURE

TR Test Report Complementary Testing RKN e1 Container (+5 C) Protection by Insulation Version: 01 Page: 2 (22)

ANSI/ASSE Z359 Fall Protection Code Revisions strengthen benchmark consensus standard

AN OVERVIEW OF THE ANSI Z359 FALL PROTECTION CODE

WYDOT CONCRETE MIX DESIGN PROCEDURE

Chicago Rabbinical Council 2701 West Howard Street Chicago, IL (773) Fax: (773) Rabbi Sholem Fishbane, Kashruth Administrator

ISO/IEC JTC 1/SC 2 N 3208

Certificate of Accreditation

This document is a preview generated by EVS

HUMOR 20 HUMOR 20. High-precision Humidity Calibrator. Water T, p1

Originally Issued: 10/08/2010 Revised: 10/27/2017 Valid Through: 10/31/2018

DAIRY. Record Book.

Intra-EU trade in live wild boar. PAFF April 2018

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

CALIBRATION CERTIFICATE # 500

MIDDLESEX COUNTY AMATEUR SWIMMING ASSOCIATION

Stator Resistance Thermometers

1. Introduction. The Easy Guide to TMV3 Approval

Height Safety Lifting Load Control

HEAVY DUTY PNEUMATIC

Traceable calibration of automatic weighing instruments in dynamic operation

Distribution Connection Forms

Height Safety Lifting Load Control

Unique mounting features for Thermal Mass Flow Meters. By Martin Raab in cooperation with CaTeC b.v.

PFS Test Report TL-109

First Revision No. 37-NFPA [ Detail ]

Certificate of Accreditation

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z TROXLER ELECTRONICS LABORATORIES, INC. James Pratt Phone:

IECEx Certificate of Conformity

IRB Regulation 22 Performance Specification Re-test Field Report

Speed of opening, stability, descent rate

Standards of Practice Emergency Shower/Eyewash Installation, Use, Testing & Maintenance

TYPE APPROVAL CERTIFICATE

Gene Milligan T10 Principal Member

AAMA/WDMA/CSA 101/I.S.2/A AAMA/WDMA/CSA 101/I.S.2/A STRUCTURAL PERFORMANCE TEST REPORT SUMMARY RENDERED TO:

Product(s) approved by this certificate is/are accepted for installation on all vessels classed by DNV GL.

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Engineering Report Crash Safety (Impulse) Shock Test. Crystal Group, Inc. for. Prepared by. Phillip M. Toftely, Test Engineer.

EU Declaration of Conformity

This document is a preview generated by EVS

Fumehood Performance Test Report

Certificate of Accreditation

Hosted By: North Coast Aquatics (NCA)

GRADES FABRIC. SPECIFY: Dimensions are in inches and are approximate. Upholstery Contact Customer Service if dimensions are critical.

Transcription:

Declaration of Conformity In Accordance with ANSI/ISEA 125-2014 Alexander Andrew, Inc. 1306 S. Alameda St Compton, CA 90221 Declaration # D0215012 Declaration Date 2.25.15 Tested Item # 6' DuraTech Web Mini SRD Additional Items Conforming Under this Declaration: 72706SA1 72706SA2 72706SA3 72706SA5 72706SA6 72706SB1 72706SB2 72706SB3 72706SB4 72706SB5 72706SB6 72706SD1 72706SD3 72706SE2 72706SF4 72706SF6 72706SG5 72706SG6 72706TB1 72706TB2 72706TB3 72706TB4 72706TB5 72706TB6 Alexander Andrew, Inc. declares that the product(s) listed above is in conformity with the requirements of the following performance standard(s): Conformity Assessment Method in accordance with ANSI/ISEA 125-2014 Level 1 Level 2 X Level 3 Level 1: Lab Outside the Scope of ISO/IEC Standard 17025:2005 Level 2: Lab Within the Scope of ISO/IEC Standard 17025:2005 Level 3: Independent 3rd Party Lab accredited to ISO/IEC Standard 17025:2005 Supporting Documentation PC-0542 PC-0543 Authorized Signature Name Dustin Hawkins Title VP Business Development Date 9.11.15 DoC Rev1 7.2.14

Ex ova OCM Attached to this attestation is the test report generated by Testing Laboratory. Exova OCM test witness certifies the report accurately presents the testing performed on the samples identified. Test Report # Date PC-0542 2/25/2015 Base Part# Sample ID's Results 2333203 2333184 2333188 2333200 2333189 2333208 2333175 2333171 2333187 2333193 1234571 2333193 2333172 2333177 2333173 2333190 2333209 2333207 Test Witness Signature: Robert Fortner Technician Mechanical Laborato (Signed for and on behalf of Exova-OCM) Approval Signature: Bruce K. Sauer Technical Director Approval Signature: Thomas J. (Tom) Parsons Manager Quali I Technical Services (Signed for and on behalf of Exova-OCM) ~~ This attestation shall not be reproduced except in full, without the written approval of Exova-OCM. The laboratory has witnessed the testing the material I items supplied by the client as sampled by the client. The testing is not within Exova OCM's L.A.B scope of testing and was not performed at Exova OCM. LABORATORY ACCREDITATION...-----.- BUREAU ACCREDITED Certificate# L2195 Testing ISO/IEC 17025 Testing Laboratory Attestation Number: 350239-2 Revision Letter: Original Page 2 of 2 Exova OCM 3883 East Eagle Drive Anaheim, CA 92807 USA

Test Report PC-0542 Date 2/25/2015 Rev Rev Date 4.2.1, 4.2.3, 4.2.5, 4.2.6, 4.2.8.1, PC-0542 Date Received Test Operator Peter Mahbubani Test Operator Yesbet Sierra Sample ID 2333203 2333184 2333188 2333200 2333189 2333208 2333175 2333171 2333187 2333193 1234571 2333193 2333172 2333177 2333173 2333190 2333209 2333207 Material/Sample Identification Certificate# TL-594 Testing Page 1 of 26 FLT-08 Rev. D 10/1/2014

Test Report PC-0542 Date 2/25/2015 Rev Rev Date 4.2.1, 4.2.3, 4.2.5, 4.2.6, 4.2.8.1, PC-0542 Date Received 4.2.1 Test Summary Test Criteria Test Result /Fail < 1800 Lbf Class A < 1350 Lbf Class B < 900 Lbf 17.6" 1342.1 LBf 876.9 LBf 1.6 LBf 21.7" 4.2.1 4.2.1 4.2.3 4.2.3 4.2.3 Dynamic Strength Line Constituent Strength Dynamic Strength Line Constituent Strength Dynamic Strength Line Constituent Strength < 1800 Lbf 1202.6 LBf Class A < 1350 Lbf Class B < 900 Lbf > 1000 Lbf 1042.3 LBf 4' Fall w/ 300 Lb Test Weight; Weight Shall Not Strike the Ground 18.1" < 1800 Lbf 1285.0 LBf Class A < 1350 Lbf Class B < 900 Lbf 4' Fall w/ 300 Lb Test Weight; Weight Shall Not Strike the Ground 914.7 LBf 1.8 LBf Did not strike ground Did not strike ground > 1000 Lbf 1040.1 LBf 4' Fall w/ 300 Lb Test Weight; Weight Shall Not Strike the Ground 828.3 LBf 1.8 LBf Did not strike ground > 1000 Lbf 1040.8 LBf Certificate# TL-594 Testing Page 2 of 26 FLT-08 Rev. D 10/1/2014

Test Report PC-0542 Date 2/25/2015 Rev Rev Date 4.2.1, 4.2.3, 4.2.5, 4.2.6, 4.2.8.1, PC-0542 Date Received 4.2.5 Static Strength > 3,000 Lbf for > 60 Seconds 3021.1 lbf 4.2.5 Static Strength > 3,000 Lbf for > 60 Seconds 3018.8 lbf 4.2.5 Static Strength > 3,000 Lbf for > 60 Seconds 3021.8 lbf 4.2.6 2.1 lbf 4.2.6 2.4 lbf 4.2.6 2.2 lbf 18.7" 4.2.8.1 4.2.8.1 4.2.8.1 < 1800 Lbf 1133.9 LBf 18.7" < 1800 Lbf 1305.8 LBf 789.9 LBf 2.2 LBf 20.6" < 1800 Lbf 1076.2 LBf 785.0 LBf 1.6 LBf 837.3 LBf 1.75 LBf Certificate# TL-594 Testing Page 3 of 26 FLT-08 Rev. D 10/1/2014

Test Report PC-0542 Date 2/25/2015 Rev Rev Date 4.2.1, 4.2.3, 4.2.5, 4.2.6, 4.2.8.1, PC-0542 Date Received 12.25" 4.2.8.2 4.2.8.2 4.2.8.2 < 1800 Lbf 1197.2 LBf 18.0" < 1800 Lbf 1254.0 LBf < 1800 Lbf 1120.8 lbf 838.1 LBf 2.4 lbf 897.5 LBf 1.8 lbf 16.4" 851.3 lbf 2.0 lbf 19.1" 4.2.8.3 < 1800 Lbf 1168.2 lbf 776.0 lbf 1.8 lbf 21.9" 4.2.8.3 < 1800 Lbf 1250.5 lbf 815.3 lbf 1.8 lbf Certificate# TL-594 Testing Page 4 of 26 FLT-08 Rev. D 10/1/2014

1306 S. Al~111etJ~ Slr eel, I el: (::!:.13) hl UUbU PC-0542 lieill1lm.il'l.gm~=:i l.tll~ Date I 2/2512015 Rev I I Rev Date I 4.2.1, 4.2.3, 4.2.5, 4.2.6, 4.2.8.1, Base Part# Proposed Part# Test Request# NIA PC-0542 I BOMINo Date Received 212312015 I Date Complete! 2/2412015 Class A!:24" Class B :;54" 19.2" 4.2.8.3!: 1800 Lbf 1330.6 lbf Class A:; 1575 Lbf Class B:; 1125 Lbf 923.0 lbf 1.25 Lbf- 25 Lbf 2.0 lbf P/N Self-retracting Device meets the requirements of ANSI Z359.14 2012. Lab Quality Manager Peter Mahbubani!Witnessed by l:c..u 11r.1Ctllfl;. ' H r.lui '~~ I Date I 2/25/2015 I ~~ I Date I '1/rs1/1':{' ~ ~IS ;ab:""a"l:... s accru:lrtt::i,.. a::con:lar:ct: Nl't'!'I Ult: -.c'.:grhze:i '"te,,.at.;;:i,..,a, itat'::i ::#!SO IE(. l 7C25.lCCS.,,\I XC't:lrUf:..:lt'. ::IUT'\.:l'IH'1fttl ttchj"~ =-="'e t ~C fer a ::lef~e::i sc::a:e al"i~ tl'le :i;;;trat:-c~ ~fa lab-:: rate') :i,..,al":t 1 Ta,,ag -r.e,,t S('.ltt:IT' l"tlf'l' tc tl'le J-= 1"1t ~ ~~-1.\F C.0,,...,..11,.>q,.; t: :lated ia-111a,... ~CC9 t ACCREDITED Certificate" TL-594 Testing Page 5 of 26 FLT-08 Rev. D 10/1/2014

Exova ClCM Attached to this attestation is the test report generated by Testing Laboratory. Exova OCM test witness certifies the report accurately presents the testing performed on the samples identified. Test Report # Date PC-0543 2/25/2015 Test Witness Signature: Robert Fortner Technician Mechanical Laboratory Base Part# Sample ID's Results 2333206 2333202 2333176 2333183 2333204 2333178 2333175 2333171 2333187 2333203 1234184 2333188 2333182 2333164 2333212 2333210 2333194 2333167 2333169 2333191 2333201 (Signed for and on behalf of Exova-OCM) ~ ~--=-.). -:::> Approval Signature: Bruce K. Sauer Technical Director Approval Signature: Thomas J. (Tom) Parsons Manager Qualit I Technical Services (Signed for and on behalf of Exova-OCM) c?-w~ This attestation shall not be reproduced except in full, without the written approval of Exova-OCM. The laboratory has witnessed the testing the material I items supplied by the client as sampled by the client. The testing is not within Exova OCM's LAB scope of testing and was not performed at Exova OCM. Testing Laboratory Attestation Number: 350239-3 Revision Letter: A Page 2 of 2 Exova OCM 3883 East Eagle Drive Anaheim, CA 92807 USA LABORATORY ACCREDITATION...------ BUREAU ACCREDITED Certificate# L2195 Testing ISO/IEC 17025

Test Report PC-0543 Date 2/25/2015 Rev Rev Date 4.2.1, 4.2.3, 4.2.5, 4.2.6, 4.2.8.1, PC-0543 Date Received Test Operator Peter Mahbubani Test Operator Yesbet Sierra Sample ID 2333176 2333183 2333204 2333175 2333171 2333187 2333182 2333164 2333212 Material/Sample Identification 2333206 2333202 2333178 2333203 2333184 2333188 2333210 2333194 2333167 2333169 2333191 2333201 Certificate# TL-594 Testing Page 1 of 26 FLT-08 Rev. D 10/1/2014

Test Report PC-0543 Date 2/25/2015 Rev Rev Date 4.2.1, 4.2.3, 4.2.5, 4.2.6, 4.2.8.1, PC-0543 Date Received Test Criteria Test Result /Fail 4.2.1 Test Summary < 1800 Lbf Class A < 1350 Lbf Class B < 900 Lbf 18.9" 1136.6 lbf 806.6 lbf 1.8 lbf 14.0" 4.2.1 4.2.1 4.2.3 4.2.3 4.2.3 Dynamic Strength Line Constituent Strength Dynamic Strength Line Constituent Strength Dynamic Strength Line Constituent Strength < 1800 Lbf 1149.4 lbf Class A < 1350 Lbf Class B < 900 Lbf 853.7 lbf 2.2 lbf 13.1" < 1800 Lbf 1234.2 lbf Class A < 1350 Lbf Class B < 900 Lbf 4' Fall w/ 300 Lb Test Weight; Weight Shall Not Strike the Ground 866.2 lbf 2.0 lbf Did not strike ground > 1000 Lbf 1040.8 lbf 4' Fall w/ 300 Lb Test Weight; Weight Shall Not Strike the Ground Did not strike ground > 1000 Lbf 1041.5 lbf 4' Fall w/ 300 Lb Test Weight; Weight Shall Not Strike the Ground Did not strike ground > 1000 Lbf 1040.1 lbf Certificate# TL-594 Testing Page 2 of 26 FLT-08 Rev. D 10/1/2014

Test Report PC-0543 Date 2/25/2015 Rev Rev Date 4.2.1, 4.2.3, 4.2.5, 4.2.6, 4.2.8.1, PC-0543 Date Received 4.2.5 Static Strength > 3,000 Lbf for > 60 Seconds 3021.1 lbf 4.2.5 Static Strength > 3,000 Lbf for > 60 Seconds 3018.8 lbf 4.2.5 Static Strength > 3,000 Lbf for > 60 Seconds 3021.8 lbf 4.2.6 2.1 lbf 4.2.6 2.4 lbf 4.2.6 2.2 lbf 24.2" 4.2.8.1 4.2.8.1 4.2.8.1 < 1800 Lbf 989.0 lbf 766.9 lbf 1.8 lbf 19.8" < 1800 Lbf 1226.7 lbf 815.6 lbf 1.8 lbf < 1800 Lbf 1218.7 lbf 23.3" 769.1 lbf 1.8 lbf Certificate# TL-594 Testing Page 3 of 26 FLT-08 Rev. D 10/1/2014

Test Report PC-0543 Date 2/25/2015 Rev Rev Date 4.2.1, 4.2.3, 4.2.5, 4.2.6, 4.2.8.1, PC-0543 Date Received 20.4" 4.2.8.2 4.2.8.2 4.2.8.2 < 1800 Lbf 1312.8 lbf 844.3 lbf 1.8 lbf 19.2" < 1800 Lbf 1026.6 lbf < 1800 Lbf 1150.2 lbf 783.6 lbf 1.8 lbf 20.1" 874.7 lbf 1.6 lbf 25.4" 4.2.8.3 < 1800 Lbf 972.1 lbf 801.3 lbf 1.6 lbf 22.8" 4.2.8.3 < 1800 Lbf 1037.8 lbf 826.8 lbf 1.8 lbf Certificate# TL-594 Testing Page 4 of 26 FLT-08 Rev. D 10/1/2014

4.2.1, 4.2.3, 4.2.5, 4.2.6, 4.2.8.1, 4.2.8.2, 4.2.6.3 Base Part# Proposed Part# PC-0543 BuiltB Whom Date Received Class A~ 24" Class BS54" 21.9" ANSI 2359.14-2012 4.2.8.3 S1800 Lbf Class A~ 1575 Lbf Class B ~ 1125 Lbf 1.25 Lbf 25 Lbf 1049.6 lbf 829.6 lbf 3.8 lbf Lab Quality Manager Peter Mahbubani Date 4/20/2015!witnessed by Date C> m '-l -...i a!:=-n:, '>:: ir::rtir:t - ~ : :: :ia-c:e.-llt.. f"e "'l!::r.ze=.. te '"n =- ~a,,:;a : :.C E: 1 7 J~S z::s -.. J a.::-::: e::'tat ~- ::e-r :-st" t s tir =oo: - -::a.::-ro;:ete'":tt r: 01 :hif '"t::l' J::;::ir ar-:1 t~e ::irrat :. "' :;fa a~:: at::, :l'..:a Tf Ta a;rte.? l>sfl'... e'e t:; t~t: : "'t '50 ',..1.~- J.1' :.:TT:."' :;:.. e :;IJH:t. a"'.. ar, z.;.:;9 ACCRrnlTED Certificate# TL-594 Testing Page 5 of 26 FLT-08 Rev. D 10/1/2014