Mass Flow Meter (MFM) for Gases

Similar documents
Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases

Bypass Mass Flow Controller (MFC) for gases

Mass Flow Controller (MFC) for Gases

Mass Flow Meter (MFM) for gases

Mass Flow Controller (MFC)/ Mass Flow Meter (MFM) for gases

Mass Flow Controller (MFC) for gases. Inline MFC for nominal flow rates from 25 I N. /min to I N

2/2-Way Solenoid Control Valve

2/2-Way Proportional Valve (motor-driven)

2/2-Way Solenoid Control Valve

2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version

2/2-way proportional valve

2/2-way proportional valve

Vortex Flow Sensor VA Di Ex-d for flow measurement in gases; with integrated, configurable transducer UVA in Ex-d housing

4/2 way Pneumatic Solenoid Valve

The affordable consumption counter for compressed air and gases R 3 /4 (DN 20)

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

KMT. Thermal Mass Flow Meter. for Compressed Air and Gases. Measuring range: m3n/h m3 N

Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres

X-Flow Mass Flow Controller 授权代理 : 北京品超思瑞科技学院公司

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

C-Flow Coriolis Mass Flow Meters

Thermal flow sensor TA Di with integrated transducer for measuring mass flow, standard flow rate and air / gas consumption

Design Features. General Description

Model 601CV. Mass Flow Controller. Product Features:

Armatures for analytical probes

Brooks TMF-Zone 1 Models 5816-Ex/5864-Ex

Thermal flow sensor TA Di for separate evaluation units for measuring mass flow, standard flow rate and air or gas consumption.

Pneumatic high-pressure controller Model CPC7000

Precision pressure sensor Basic version Model CPT6020

EPP4 Pressure Regulator Basic G 1/4"

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

Self-operated Pressure Regulators for special applications

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

KMT. Thermal Mass Flowmeter. for compressed air and gases. Measuring range: Nm³/h Nm³/h

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

Technical Data Sheet T 2025

Features. Description

Model PDT Dewpoint Transmitter

ATM/GR. Electronic pressure switches CUSTOMER BENEFITS

SonoMeter 30 Energy Meters

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Operating Instructions for Direct Flow Mass Flow Meter for gases. Model: DMW

T 2523 EN Type 2406 Excess Pressure Valve Self-operated Pressure Regulators ANSI version

SPCH/ Blowing block

MANUAL KPS Pressure Control Valve

Gas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series

Digital Mass Flow Meters and Controllers for Gases

Self-operated Pressure Regulators Type 2405 Pressure Reducing Valve

better measurement Simply a question of

Thermal Energy Flowmeter Model KEC. Application Range. Special Features

Valve Proving System VDK 200 A S02

Valve Proving System VDK 200 A S06*

GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-300-VEF MBC-700-VEF MBC-1200-VEF

OPTIBAR P 1010 C Technical Datasheet

TRZ 03-K Volumeter. Proven Technology. Superior Performance. TRZ 03-K Volumeter is a Turbine Gas Flowmeter for Secondary Gas Metering.

Pressure regulator for water

AFC. SDPROC and AFC Analog Mass Flow Controller ANALOG MASS FLOW CONTROLLERS. Principles of Operation. Design Features

Ratio Regulator Zero Governor. FRG/6 Series

Flow metering in gases Introduction to COMBIMASS family

NGN Series nitrogen generator

Operating Instructions DB41

Series 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve. ANSI version

DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM

MCQ Gas Blender 100 Series 3 Channels Gas Mixer

GA24 Technical Datasheet

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series

Pneumatic high-pressure controller Model CPC7000

RB 4700 Commercial & Industrial Regulator

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

V83 series Redundant valve manifold systems - Modular with bypass 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

Series 44 Self-operated Pressure Regulators. Type 44-0 B Pressure Reducing Valve. ANSI version

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

MASS-STREAM TM Instruction Manual. D-6200 Analog Mass Flow Meters / Controllers

KTE6000 / KTU6000 Series OEM pressure transmitters for industrial media

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series

The number of revolutions is proportional to the passed volume. The rotation is transferred to a mechanical index, which indicates this volume.

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves single-stage atmospheric operating mode GB-(LEP) 057 D01

Old documentation - Only for your information! Product is not available any more!

Compact pressure switches for gas and air

Type 4708 Supply Pressure Regulator

Solenoid valves VZWF, force pilot operated

Instruction Manual Contact Pressure Vacuum Gauge

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Type 4708 Supply Pressure Regulator

SITRANS P measuring instruments for pressure

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

High-performance submersible pressure transmitter For level measurement Model LH-20

Programmable pressure and temperature transmitters PTM/RS485

Gas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series

RR 16 Commercial & Industrial Regulator

SV - Safety Shutoff Valve with Proof of Closure 1/2" NPT - 2" NPT. SV/614 Series SV-DLE/614 Series

Products Solutions Services. Gas Flow Measurement

Programmable pressure and temperature transmitters PTM/RS485

Transcription:

873 Mass Flow Meter (MFM) for Gases Direct flow measurement by MEMS- Technology for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 ) High accuracy Short response time Compact design and digital communication Type 873 can be combined with Type 8619 Multichannel program controller Type 33 3/2 or 2/2-way solenoid valve Type 613 2/2 way solenoid valve Mass flow meter are used in process technology for the direct measurement of the mass flow of gases. In case of volumetric flow meters, it is necessary to measure the temperature and the pressure or the density, because gases change their density or rather their volume depending on the pressure. The measurement of the mass flow, on the other hand, is independent of the pressure and temperature. The digital mass flow meter type 873 uses a sensor on silicon chip basis located directly in contact with the gas. Due to the fact that the sensor is directly in the bypass channel a very fast response time of the MFM is reached. The actual flow is given over RS485-communication. Type 873 can optionally be calibrated for two different gases, the user is able to switch between these two gases. This instrument communicates with master devices digitally, no further A/D conversions needed. The MassFlowCommunicator software can be used for parameterisation and diagnosis. Technical Data Nominal flow range 1) 1 ml N /min 2) to 8 l N /min (N 2 ), (Q nominal ) see table on p. 2 Turn-down ratio 1:5, higher turn-down ratio on request Operating gas Neutral, non-contaminated gases, on request Calibration gas Operating gas or air with conversion factor Max. operating pressure 1 bar (145 psi) (Inlet pressure) depending on the orifice of the valve Gas temperature - 1 to + 7 C (- 1 to + 6 C with oxygen) Ambient temperature - 1 to + 5 C Accuracy ±.8 % o.r. ±.3 % F.S. (after 1 min. warm up time) Repeatability ±.1 % F.S. Response time (t 95 % ) < 3 ms Materials Body Aluminium or stainless steel Housing Metal Seals FKM, EPDM Port connection NPT ¼, G ¼, screw-in fitting or sub-base, others on request Electr. connection Plug D-Sub 9 pin Power supply 24 V DC Voltage tolerance ± 1 % Residual ripple < 2 % Power consumption 5 W Communication Digital via RS485 (half-duplex or fullduplex), RS422 Protection class IP4 Dimensions [mm] see drawings p. 5-6 Total weight ca. 5 g (aluminium body) Installation horizontal or vertical Light emitting diodes (default functions, Indication for power, limit and error other functions programmable) Binary Input Not assigned (default, other functions programmable) Binary Output (default, other functions programmable) One relay-output for Limit (process value close to full scale value) Max. load: 25 V, 1 A, 25 VA 1) The nominal flow value is the max. flow value calibrated which can be controlled. The nominal flow range defines the range of nominal flow rates (full scale values) possible. 2) Index N: Flow rates referred to 1.13 bar and C. Alternatively Index S which refers to 1.13 bar and 2 C. www.burkert.com p. 1/6

873 Measurement principle The actual flow rate is detected by a sensor. This operates according to a thermal principle which has the advantage of delivering the mass flow without any corrections for the required pressure or temperature. A small part of the total gas stream is diverted into a small, specifically designed bypass channel, that ensures laminar flow conditions. The sensor element is a chip immersed into the wall of this channel. The chip, produced in MEMS technology, contains a heating resistor and two temperature sensors (thermopiles) which are arranged symmetrically upstream and downstream of the heater. The differential voltage of the thermopiles is a measure of the mass flow rate passing this bypass channel. The calibration procedure effectuates a unique assignment of the sensor signal to the total flow rate passing the device. Pressure Loss Diagram (ref. to air, with 25μm inlet filter) p [mbar] 12 11 1 9 8 7 6 5 4 3 G1/4 Flansch The diagram shows exemplarily the pressure loss characteristics when air fl owing through. For determining the pressure loss with another gas it needs to calculate the air equivalent and respect the fl uidics needed with the other gas. 2 1 5 1 15 2 25 3 35 4 45 5 55 6 65 7 75 8 Q [l N/min] Notes regarding the selection of the unit (Other gases on request) Gas Min. Q nom [l N /min] Argon.1 8 Helium.1 5 Carbon dioxide.2 4 Air.1 8 Methane.1 8 Oxygen.1 8 Nitrogen.1 8 Hydrogen.1 5 Max. Q nom [l N /min] Notes regarding the selection of the unit The decisive factors for the perfect functioning of an MFM within the application are the fl uid compatibility, the normal inlet pressure and the correct choice of the fl ow meter range. The pressure drop over the MFM depends on the fl ow rate and the operating pressure. The request for quotation form on page 6 contains the relevant fl uid specifi cation. p. 2/6

873 Ordering table for accessories Article Article no. 9 pin electrical connection D-Sub socket 9 pin solder connection with housing Adapters 3) USB adapter (version 1.1, USB-socket type B) USB connection cable 2 m Communication software MassFlowCommunicator 917623 67693 772299 Download from www.buerkert.com 3) The adapter accessories are used for commissioning and diagnostics and are not absolutely necessary for operation. Software MassFlowCommunicator for Communication with Bürkert MFC/MFM The communication software allows the user to program additionally various functions. For that purpose the MFC or MFM has to be connected to the computer by a RS232 adapter. p. 3/6

873 Pin Assignment 6 9 1 5 Pin Connection 1 Binary input (related to GND Pin2) 2 GND 3 Power supply + 24 V DC 4 Relay, normally opened 5 Relay, normally closed 6 TX+ (RS485-Y) bridge with pin 9 at half-duplex 7 TX- (RS485-Z) bridge with pin 8 at half-duplex 8 RX- (RS485-B) 9 RX+ (RS485-A) Networking Pin 9, RS485 A Pin 8, RS485 B Pin 9, RS485 A Pin 8, RS485 B Pin 9, RS485 A Pin 8, RS485 B Master: i.e. PLC with RS485 Interface Slaves (max. 32) Mass Flow Controller p. 4/6

873 Dimensions [mm] Threaded version 2x M 4 6 1 97 17 28 2 approx. 3.5 1.7 8.5 61.5 29 12.5 G1/4 or NPT1/4 12 Sub-base version 4x 4.5 58.5 17.75 14 14 17.75 35.5 35.5 2x 8.8 2x 6 1 26 58.5 81 92 97 43 17 approx. 3.5 1.7 8.5 61.5 29 2 x M 4 5 p. 5/6

873 MFC/MFM-applications - Request for quotation Please complete and send to your nearest Bürkert sales centre Company Contact person Note You can fill out the fields directly in the PDF file before printing out the form. Customer No Address Postcode/Town Department Tel./Fax E-mail MFC-Application MFM-Application Quantity Required delivery date Medium data Type of gas (or gas proportion in mixtures) Density kg/m 3 4) Gas temperature [ºC or ºF] ºC ºF Moisture content g/m 3 Abrasive components/solid particles no yes, as follows: Fluidic data Flow range Q nom Min. l N /min 4) l S /min (slpm) 5) Max. m N3 /h 4) kg/h c m N3 /min 4) c m S3 /min (sccm) 5) l N /h 4) l S /h 5) 6) Inlet pressure at Q nom p 1 = bar(g) Outlet pressure at Q nom p 2 = bar(g) Max. inlet pressure P 1max bar(g) MFC/MFM port connection without screw-in fitting ¼" G-thread (DIN ISO 228/1) ¼" NPT-thread (ANSI B1.2) with screw-in fitting (acc. to specification for pipeline) mm pipeline (external Ø) inch pipeline (external Ø) Flange version Installation Ambient temperature horizontal vertical, flow upwards C vertical, flow downwards Material data Body Aluminium Stainless steel Seal FKM EPDM Please quote all pressure values as overpressures with respect to atmospheric pressure bar(ü) 4) at: 1.13 bar(a) and C 5) at: 1.13 bar (a) and 2 C 6) matches with calibration pressure To find your nearest Bürkert facility, click on the orange box www.burkert.com In case of special application conditions, please consult for advice. Subject to alteration. Christian Bürkert GmbH & Co. KG 18 / _EU_en_891971 p. 6/6