Topline Peristaltic Dosing Pump for PAC Installation, Commissioning and O&M Manual

Similar documents
Nothing's as cool, as a freshwater pool. easychem 770 ORP and ph Controller for Pools and Spas with Timer Output for Pool Pump

TOPLINE ELECTRONICS LTD CO2 CONTROL UNIT MANUAL

UsER manual for Watersens ph -REDOX

Installation and Maintenance Manual. ECO Filtration Unit with 6-way-Top-Mount-Valve. Art. Nr

Instructions for Use

MAGNA-CHEM AUTOMATIC CHLORINATOR - MODEL: CSA-2P MAGNA ORP Chlorine Pump

Guide to Winterising. Pool Treatment

After filling the pool with clean water in the summer, two basic factors can take place due to the exposure of water to the sun and the air.

swimming pool technology

SM Models Manual Control

Super-Clean SCT Series SuperClean Sand Filter. Installation Manual

SM Models Manual Control

The Refurbishment of Filtration & Chemicalisation Systems On A Recent Project

Compact4Pool. pool filters. For spas and swimming pools by up to 20,000 litres Pump, filter, pre-filter and UV-C in one. Advantages of Compact4pool:

VERTICAL AIR COMPRESSORS

Dosing & Granudos. Controllers. Chemical Storage. Chemical. Dosing &

Ventam 85 Installation & Commissioning Instructions

Catalina Spa-kle Installation and User Guide

NEWS: 20% discount on service agreements signed before 1st March 2010

Above Ground Pool Care The Complete Guide to Fun Pool Water Maintenance

CLEANING AUTO CELL OWNERS HANDBOOK

INSTALLATION AND OPERATING INSTRUCTIONS

Columbus Instruments

Sanitizers. Sanitizers. Sanitizers for Pools & Spas

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119

Budget Range Operators Handbook

VERTICAL AIR COMPRESSORS

GRUNDFOS alldos product information. Vaccuperm 111 / 113. Vacuum gas dosing systems for chlorine gas, ammonia, sulphur dioxide and carbon dioxide

PART 1 GENERAL..2 Components of the gas chlorination system include, but are not limited to the following:

Sanitizers. Sanitizers. Sanitizers for Pools & Spas

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION

Technical Service Bulletin March 2015 TSB142.01

VACCUPERM Vacuum chlorine gas dosing systems

CARTRIDGE FILTERS. Models: CF50, CF75, CF100, CF150,

Semi-Automatic Controllers

JET SWIM ELEGANCE 70 INSTALLATION AND USER GUIDE

AutoChanger Installation & User Guide Issue 2

Instruction Manual Contact Pressure Vacuum Gauge

OXYGEN MINERALE ABSOLUTE RANGE OWNER S MANUAL OXY MINERALE 600/1000 SERIES

ORB-400 BUBBLE/HAZE MACHINE. Item ref: UK User Manual

hth EASIFLO SYSTEM New Generation for 2015 Feeder specifications hth EASIFLO The perfect solution for treatment of commercial swimming pools

Manual. Online Degasser DDG-75. Manual Degasser DDG-75 April DURATEC Analysentechnik GmbH Rheinauer Strasse 4 DE Hockenheim Germany

TWO POST RAM PACKAGE 5 GALLON READ THIS MANUAL CAREFULLY BEFORE INSTALLING, OPERATING OR SERVICING THIS EQUIPMENT.

OEM Manual. MODEL ½ Digit DRUM SCALE

Installation, operating and maintenance Instructions for Seemag bypass level indicator

USER MANUAL. AirPal Air Supply. (AS-1100 North America) 1488 Limeport Pike, Coopersburg, PA airpal.com fax

COUNTER CURRENT UNIT. Instruction Manual

Instruction Manual Updated 7/26/2011 Ver. 2.2

PUREX PROTECT PLUS 6/1. PRODUCT: Phosphoric Acid / Vinyl Copolymer. USAGE IN: Inground and aboveground pools and spas

Pool Information 2015

Experiment Instructions. Circulating Pumps Training Panel

Operating Manual RP and SMT Models

Pressure switches for air and water CS

RAMZONICS. Saltwater Chlorinator

INSTALLATION & SPA CARE MANUAL MODEL SPA-1R. - Outdoor Unit - FOR ALL SPAS UP TO 2,000 GALLONS

SP/ST/SA Models Pulse-input and Analog-input Control

PORTABLE WORK LIGHT MODEL NO: CL6FS OPERATION INSTRUCTIONS PART NO: GC0315

24L AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: RANGER 7/240 PART NO: LS0913

Vessel Installation and Operating Manual

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

Fiber Optic Lighted Bubbler Spillway Pot (DLP-45) Installation Manual

SALT CHLORINATOR RANGE CATALOGUE

3/8" Dr. Air Butterfly Impact Wrench

AP100 series ph/redox (ORP) cartridge sensors with water-wash option

100L AIR COMPRESSOR MODEL NO: TIGER 16/1010 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

O2100C Oxygen Measurement Module Technical Use Notes do not use other wall adapters with the O2100Cmodule. 10% / V 5% / V 2% / V 1% / V 10% / V

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

The Univentor 1250 Anaesthesia Unit

PUNE TECHTROL PVT LTD. Instruction and Maintenance Manual for Float and Tape Gauge FTG

Jacuzzi. J-CQ420 Cartridge Filter Installation and Operating Instructions

Air Differentail Pressure Switch

Waste Management System.

TECHNICAL ACCESSORIES

SALT WATER CHLORINATORS INSTALLATION INSTRUCTIONS

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

IntelliChlor Power Center (For use with IntelliChlor model IC60, IC40 and IC20)

CCS240 and CCS241. Technical Information. Sensors for chlorine dioxide Amperometric, membrane-covered sensors for installation in the CCA250 assembly

1020 Industrial Drive, Orlinda, TN fax

For pure and gentle pool and spa water

Model 130M Pneumatic Controller

24L AIR COMPRESSOR MODEL NO: TIGER 11/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

Endura AZ40 Sensor assembly Smart electronics PCB

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL

OWNER S TECHNICAL MANUAL

User Manual. MagnaMaster and ChloroMaster Electrolytic Chlorinator.

Advanced Fluid Handling Cart Owner s Manual

multi-boost the EPS range of multi-boost water systems Owners Manual Installation Operation Maintenance demand special treatment

Digital Melting Point Apparatus

TWO POST RAM PACKAGE 55 GALLON

MoveRoll Conveyor Operating and Maintenance Manual

1020 Industrial Drive, Orlinda, TN fax

24L OIL FREE AIR COMPRESSOR MODEL NO: TIGER 7/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS10/13

GENO -Flushing Compressor Product Data Sheet F 02

Water Weir Flow Controller. Introduction. Safety Precautions. Mounting the Hardware

OWNER S MANUAL NMB SERIES

Powers Controls D Day-Night Thermostats

GROUTEC SCOTT VICKERS. Grouting Equipment

ST1600 SAND FILTER PUMP

Purifier for Vinyl Lined Pools

Screw Compressors 11-22kW

Transcription:

Topline Peristaltic Dosing Pump for PAC Installation, Commissioning and O&M Manual Topline Electronics Limited 2105 This publication may not be copied, in full or in part, without prior written consent

Introduction. The Topline Peristaltic PolyAluminium Chloride (PAC) dosing pump offers low capacity precision output pump for the dosing of PAC directly from the carboy in which it is delivered, without further need for diluting or decanting. PAC is applied to swimming pools, and all such filtered water systems, to improve filtration efficiency by increasing the size of small particles of suspended solids in the water, binding them together to produce larger masses. A typical pool sand filter can produce a filtrate of around 20 microns. Many small particles, including cryptosporidium, can pass straight through the filter bed at this size. Correctly optimised PAC systems can increase the efficiency of the pool filter down to some 5 microns. Solids are backwashed away, following the filter manufacturer s instructions for correct backwashing rates, and results in crystal clear swimming pool. Lowering the amount of suspended solids in the pool with PAC dosing can often lead to a marginal lowering of chemical consumption, as there is a lower demand for chlorine from these solids, a lowering of combined chlorine and can act as a phosphate remover, reducing algae growth. Swimming pool PAC chemicals are normally designed only for sand filters up to a maximum filter rate of 35m 3 /m 2 /hr. PAC is not normally suitable for use with Diatomatious Earth filters, Cartridge filters or Zeolite filters. PAC should only be installed pre-filter, in a full flow section of pipe work, as far from the filter as possible, but after any chemical sample draw-off point. PAC can only coagulate solids in stable ph conditions. ph levels between 7.0 and 8.0 should be maintained at all times. Topline do not recommend that pre-filter chlorination (or ph correction) be applied with PAC installations as the ph will locally fluctuate during injection, leading to poor efficiency of floc production. Specification. Topline Peristaltic Dosing Pump Model Topline Peristaltic Dosing Pump Capacity 1.5 150 ml/hr Suction Lift Max 2 m Back Pressure 1.5 bar max. Hose Connections: 6 mm x 4mm ID OD Soft PVC Initial Accuracy ±10% Operating Temperature: 5-55 C Running Time 100% Protection Rating IP65 Dimensions (W x H x D): 95 x 175 x 130 mm Weight: 1.25 kg (approx.) Power AC 230 V ±10%, 50/60 Hz Fuses 0.2 A MT (fitted) Current consumption 5 VA max Page 2 of 8

Installation. The pump should be mounted on a suitable wall, or mounting board, directly above the carboy/bund for the PAC and can be mounted using the four screws and wall plugs supplied. The pump is disassembled to fix to the wall, by removing the front face plate, then unscrewing the pump body from the rear mount plate. The pump cover is removed by carefully levering the notches on either side of the pump with a flat screwdriver and pulling the cover clear. The body is removed from the support plate by loosening the four retaining screws. Cover Body Mount Plate Page 3 of 8

It is recommended that the dosing hose from the Topline peristaltic dosing pump to the injection point is as short as possible, with a maximum recommended hose length of 15m and vertical injection height of <10m. Power for the Topline peristaltic dosing pump maybe taken from any 1 amp fused supply, however since the pump should only dose into a full flow filter delivery pipe, whilst the circulation is operating, a source interlocked with the pool pumps would be preferred. Some versions of the Topline TEC range of swimming pool controllers can be used to provide a power supply interlocked to shut down with the controller flow switch. The dosing pump should be fitted with either a switched fused spur or suitably IP rated plug and socket. Topline do not typically recommend the use of IP rated standard UK 230v 13amp plug enclosures, this is to prevent accidental use of such sockets with power tools etc. which may cause damage of a chemical controller output power supply. The Topline peristaltic dosing pump is supplied with 15m of dosing hose, which should be run in a protective/carrier conduit for the entire run. We would recommend 20mm or 25mm upvc electrical conduit for this purpose. We do recommend that joints or swept bends are not solvent welded for hose replacement/inspection purposes. In common with all chemical dosing hoses we do not recommend that joints are positioned above walkways or doorways to prevent overhead chemical spillages in the event of a split hose. The cap of the supplied drum of PAC should be removed and drilled out to allow the hose(s) to pass through. The cap will be reused with subsequent carboys. Main Power Input 1 3 L 230v Terminal 3 Neutral Terminal 1 Electrical installation works may only be carried out by suitably qualified and experienced electrical engineers. Page 4 of 8

Application & Commissioning. Not all PAC products are the same. Variations in PAC concentrations are common across the many different suppliers. The stated dose rates are noted for reference only. Please refer to your chemical supplier for specific dose rates. Using the Topline peristaltic dosing pump, in keeping with the requirements of the Pool Water Treatment Advisory Group (PWTAG), PAC is dosed pre-filter 24 hours per day, all the time the filtration plant is operating. The typical operational setting is for a PAC product is around 0.1ml/m 3 /hr. This may need adjusting to suit the prevailing conditions of the pool water. For example; a heavily polluted pool, such as a children s pool, may need a setting of 0.3ml/m 3 /hr, and an Olympic size a pool, with a low use and large buffer of treated water, could possibly be lowered to 0.1ml/m 3 /hr. The Topline peristaltic dosing pump has a maximum output pressure of 1.5 Bar. The output of the dosing pump should be checked against the dose rate chart to ensure that either a higher or lower back pressure is not overrunning or impairing pump output. The pump cover is removed by carefully levering the notches on either side of the pump with a flat screwdriver. The settings on the table below should be used to set up the pump for the desired output, for example a pool of 100m 3 /hr with an applied dose rate of 0.1ml/m 3 /hr would require a dose rate of 10ml/hr. And so the selector switch would be set to Position 1 and the dial set to dial would be set to 5.5. Similarly 60m 3 /hr would require a dose of 6m/hr and so selector switch Position 1 would be set and the dial set to 3.5. To check that this setting is correct the suction hose should be put into a calibration tube (or tube of a known capacity) and the pump run for 10 minutes. The amount drawn from the tube is multiplied by 6 to give the capacity in ml/hr. The pump should be adjusted accordingly, until the correct setting is achieved. The design of the motor is provides a step-less increase from 0.5 to 194ml/hr through the potentiometer scale. This will vary however, depending upon the back pressure at the injector, the length of suction lift and the length of delivery hose (max 15m) and its elevation to the injection point. Page 5 of 8

The pump output is set by choosing the higher or lower dosing range, with the selector switch, and then carefully rotating the potentiometer from 1 10 clockwise to increase the pump output from 1.5 to 150ml/hr Selector Switch Potentiometer Dose Rates (at 0.1ml/m 3 /hr PAC) Pump Setting Switch Position 1 Switch Position 2 Output ml/hr Pool Flow m 3 /hr Output ml/hr Pool Flow m 3 /hr 1 0.5 5 19.4 194 1.5 1.2 12 29.1 291 2 2.4 24 38.8 388 2.5 3.6 36 48.5 485 3 4.8 48 58.2 582 3.5 6 60 67.9 679 4 7.2 72 77.6 776 4.5 8.4 84 87.3 873 5 9.6 96 97 970 5.5 10.8 108 106.7 1067 6 12 120 116.4 1164 6.5 13.2 132 126.1 1261 7 14.4 144 135.8 1358 7.5 15.6 156 145.5 1455 8 16.8 168 155.2 1552 8.5 18 180 164.9 1649 9 19.2 192 174.6 1746 9.5 20.4 204 184.3 1843 10 21.6 216 194 1940 Page 6 of 8

Operation There is no operational procedure to follow. The Topline Peristaltic Dosing Pump is set to run 24 hours per day, all the time the circulation is in operation. The general usage of PAC should be noted over a period of days/weeks to identify when the pump is losing efficiency. The PAC is dosed from the carboy in which it is delivered. The carboy in use and any carboy in stock must be bunded. PAC is generally an acid, and therefore must not be stored with hypochlorites. Suitable lifting and handling precautions should be made for the carboy drum, which in addition to the dead weight carries some inertia when carried, due to the movement of the liquid within. Suitable COSHH and RAMS will need to be produced for any such tasks. The Topline Peristaltic Dosing Pump will not drain the carboy completely. Wearing suitable personal protective equipment (PPE), the residue maybe decanted into a clean container and carefully poured into the new carboy (provided suitable volume is available). Service Intervals Over a period of time the Topline peristaltic dosing pump injection point may become fouled with a residue of PAC, we recommend that the injection point is checked and cleaned every six months minimum. The capillary hose will lose its elasticity over time. We recommend that the peristaltic dosing pump capillary hose be replaced every 12 months. We recommend that the injection hose be replaced every two years. Spares Capillary Hose Kit (Blue) 6mm OD x 4mm ID Hose Connection Part Number T6098 Injector ½ BSP 6mm OD x 4mm ID Hose Connection Part Number T6097 Non-Return Foot Valve- 6mm OD x 4mm ID Hose Connection Part Number T6096 Page 7 of 8

Topline Electronics Ltd A8 Ropemaker Park Hailsham East Sussex BN27 3GU Tel: 01323 440 760 Fax: 01323 844 508 sales@topline.uk.net www.topline.uk.net Topline Electronics Limited 2017 Page 8 of 8