Spirax Compact FREME Flash Recovery Energy Management Equipment

Similar documents
QuickHeat TM Packaged Heat Exchanger Solutions

DF1 and DF2 Diffusers

Dri-Line Mk3 Monnier Compressed Air Drain Trap

Dri-Line Mk2 Spirax-Monnier Compressed Air Drain Trap

TSS21 Sealed Thermostatic Steam Tracer Trap

TP1 and TP2 Temporary Cone Shaped Strainers

BT6HC Hygienic Sanitary Balanced Pressure Steam Trap for High Capacity and CIP/SIP Applications

FV Flash Vessel Installation and Maintenance Instructions

MST21 Stainless Steel Balanced Pressure Thermostatic Steam Trap

TA10A and TA10P Steam Tracing Temperature Control Valves Installation and Maintenance Instructions

Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Dial Adjustment)

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Knob Adjustment)

KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions

Fig 12, Fig 14HP, Fig 16, Fig 16HP and Fig 16L Strainers

CP10 Sensor Installation and Maintenance Instructions

DCV10 Stainless Steel Disc Check Valve for use with Condensate Pumps

Fig 1, Fig 12, Fig 13, Fig 14HP, Fig 16, Fig 16HP and Fig 16L Strainers

KBV21i and KBV40i Air Actuated Boiler Blowdown Valves

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators

PV4 and PV6 Piston Valves

MF2M Monnier Miniature Compressed Air Filter

Manual Actuated Boiler Blowdown Valves

IFTGS14 Ball Float Steam Trap ½" and ¾" with Integral Spiratec Sensor

MFP14-PPU (Vented) Automatic Packaged Pump Units

DCV1, DCV3 and DCV3LT Disc Check Valves Installation and Maintenance Instructions

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators Installation and Maintenance Instructions

MSC-P and MSC-N Manifolds for Steam Distribution and Condensate Collection

CVS10 Sanitary Check Valves

IX1 Spirax-Monnier International Compressed Air Filter Installation and Maintenance Instructions

APT14, APT14HC and APT14SHC Spares 2

AE14 Automatic Air Vents for Liquid Systems Installation and Maintenance Instructions

AVC32 Carbon Steel Air Vent for Steam Systems

UIB30 and UIB30H Sealed Inverted Bucket Steam Traps for use with Pipeline Connectors

SA Control Valve types: BM, BMF, BX, SB, NS, KA, KB, KC (Normally open) BMRA, BMFRA, BXRA, SBRA, NSRA, KX, KY (Normally closed)

ML3M Monnier Miniature Compressed Air Lubricator

DCV6 Disc Check Valve

Type 130 and HL10 'Safeguard High Limit Control' Installation and Maintenance Instructions

SRV66 Sanitary Pressure Reducing Valve

HM and HM34 Inverted Bucket Steam Traps Installation and Maintenance Instructions

FTGS14 Ball Float Steam Trap DN15 (½") to DN25 (1")

AVM7 Stainless Steel Thermostatic Air Vent

AE30 Automatic Air Eliminators / Air and Gas Vents for Liquid Systems

PC10HP Pipeline Connector (ASME 600)

BCV31 DN40 - Blowdown Control Valve

CA44, CA44S, CA46 and CA46S Air and Gas Traps

BTM7, BTS7 and BTS7.1 Stainless Steel Thermostatic Clean Steam Traps

TD62LM and TD62M Thermodynamic Steam Traps with Replaceable Seats

M33F ISO, M33S ISO and M33V ISO Ball Valves Installation and Maintenance Instructions

CS10-1 Stainless Steel Clean Steam Separator

BPT13 Balanced Pressure Thermostatic Steam Traps

M10HTi ISO Tobacco Ball Valve Screwed, SW, BW and Flanged versions

Airodyn, BRair and BRoil Compressed Air Drain Traps

TW Temperature Control Valve

Fig 3, 7, 33, 34, 34HP, 36, 36HP, 37, 3616 and Fig 3716 Flanged Strainers

MPC1M, MPC2M and MPC2AM Monnier High Efficiency Compressed Air Filter / Regulators

M111 Spiraflo Transducer

S and SF Inverted Bucket Steam Traps

M70i ISO and M80i ISO Stainless Steel Ball Valves for Sanitary Systems Installation and Maintenance Instructions

BCV31 DN20 - Blowdown Control Valve

BT6-B Sanitary Balanced Pressure Thermostatic Steam Trap

TD62LM and TD62M Thermodynamic Steam Traps with Replaceable Seats Installation and Maintenance Instructions

TDC46M, TDS46M and UTDS46M Thermodynamic Steam Traps with Maintainable Seat Installation and Maintenance Instructions

SRV2S Pressure Reducing Valve

Fig 7, 33, 33.1, 34, 34HP, 36, 36HP, 37, 3616 and Fig 3716 Flanged Strainers Installation and Maintenance Instructions

BRV71 and BRV73 Pressure Reducing Valves

BDV1 and BDV2 Blowdown / Depressurisation Valves

CA10S, CA14 and CA14S Air and Gas Traps

Vane Flow Switches Colima FLU Series

IP2M, IP2AM and IP2DM Monnier International Compressed Air Filter/ Regulators

BDV60 Blowdown Vessel Installation and Maintenance Instructions

FT53, IFT53, FT54, IFT54, FT57 and IFT57 Ball Float Steam Traps - DIN

AE50S Automatic Air and Gas Vent for Liquid Systems Installation and Maintenance Instructions

Spirax SafeBloc TM DBB3 Double Block and Bleed Bellows Sealed Stop Valve. 1. Safety information. 2. General product information. 3.

USM21 Sealed Bimetallic Steam Trap for use with Pipeline Connectors Installation and Maintenance Instructions

M45 ISO Ball Valve DN25 to 150 Installation and Maintenance Instructions

LP31 Level Probe. 1. Safety information. 2. General product information. 3. Installation. 4. Wiring. 5. Maintenance

A3S Bellows Sealed Stop Valve Installation and Maintenance Instructions

LP10-4 Level Probe. 1. Safety information. 2. General product information. 3. Installation. 4. Wiring. 5. Maintenance IM-P402-92

SCA Series Inverted Bucket Steam Traps

STERI-TROL Clean Service 'S' Series Two-port Control Valves DN15 (½") to DN100 (4")

TD45 Thermodynamic Steam Trap Installation and Maintenance Instructions

AVS32 Stainless Steel Air Vent for Steam Systems Installation and Maintenance Instructions

Thermocirc Installation and Maintenance Instructions

PC3000, PC3001 and PC4000, PC4001 Pipeline Connectors

SRV461S and SRV463S Stainless Steel Direct Acting Pressure Reducing Valves

BCVi43 Blowdown Control Valve

Standard Pressure Powered Pump Packaged Units to Size 3 x 2 Type PPEC, PTC & PTF with vented and ASME coded receivers

FT16 Ball Float Steam Trap Installation and Maintenance Instructions

STD Spray Type Desuperheater

Colima TOR Magnetic Level Switches

CA16 and CA16S-14 Air and Gas trap Installation and Maintenance Instructions

BSA6T and BSA64T Stainless Steel Bellows Sealed Stop Valves Installation and Maintenance Instructions

UBP32 Sealed Balanced Pressure Thermostatic Steam Trap for use with PC_ Pipeline Connectors Installation and Maintenance Instructions

VAD Variable Area Desuperheaters

FT43, FT44, FT46 and FT47 Ball Float Steam Traps Installation and Maintenance Instructions

1. General safety information. 2. General product information. 3. Installation. 4. Commissioning. 5. Operation. 6. Maintenance. 7.

Fig 1, Fig 12, Fig 13, Fig 14, Fig 16 and Fig 16L Strainers Installation and Maintenance Instructions

BTD52L Thermodynamic Steam Trap Installation and Maintenance Instructions

FTC62 and FTS62 Ball Float Steam Traps Installation and Maintenance Instructions

Transcription:

IM-UK-cFREME UK Issue 1 Spirax Compact FREME Flash Recovery Energy Management Equipment Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning 5. Maintenance Copyright 2015 IM-UK-cFREME UK Issue 1 1 Printed in GB

1. Safety information Note: This document refers only to the mechanical installation and commissioning of the Spirax compact FREME unit and should be used in conjunction with the relevant IMIs for the other system components and supplementary safety information for all the system components. Warning Your attention is drawn to Safety Information Leaflet IM-GCM-10, as well as to any National or Regional regulations that are in place. This product is designed and constructed to withstand the forces encountered during normal use. Use of the product for any purpose other than its intended use could cause damage to the product and may cause injury or fatality to personnel. Before any installation or maintenance procedure, always ensure that all primary steam and condensate return lines and secondary water lines are isolated. Ensure any residual internal pressure in the system or connecting pipeworks are carefully relieved. 1.1 Intended use Referring to the Installation and Maintenance Instructions and Name-plate check that the product is suitable for the intended use / application. The product described below complies with the requirements of the European Pressure Equipment Directive 97 / 23 / EC and carries the mark when so required. Product Maximum allowable operating limits Fluid Spirax Connection Pressure Temperature compact Primary side 14 bar g 198 C Steam & Condensate FREME Secondary side 25 bar g 170 C Water i) The product has been specifically designed for use on the fluid(s) shown above. The product s use on other fluids may be possible but, if this is contemplated, Spirax Sarco should be contacted to confirm the suitability of the product for the application being considered. ii) Check material suitability, pressure and temperature and their maximum and minimum values. If the maximum operating limits of the product are lower than those of the system in which it is being fitted, or if malfunction of the product could result in a dangerous overpressure or overtemperature occurrence, ensure a safety device is included in the system to prevent such over-limit situations. iii) Determine the correct installation situation and direction of fluid flow. iv) Spirax Sarco products are not intended to withstand external stresses that may be induced by any system to which they are fitted. It is the responsibility of the installer to consider these stresses and take adequate precautions to minimise them. v)w Remove protection covers from all connections and protective film from all name-plates, where appropriate, before installation on steam or other high temperature applications. 2 IM-UK-cFREME UK Issue 1

1.2 Access Ensure safe access and if necessary a safe working platform (suitably guarded) before attempting to work on the product. Arrange suitable lifting gear if required. 1.3w Lighting Ensure adequate lighting, particularly where detailed or intricate work is required. 1.4 Hazardous liquids or gases in the pipeline Consider what is in the pipeline or what may have been in the pipeline at some previous time. Consider; flammable materials, substances hazardous to health, extremes of temperature. 1.5w Hazardous environment around the product Consider; explosion risk areas, lack of oxygen (e.g. tanks, pits), dangerous gases, extremes of temperature, hot surfaces, fire hazard (e.g. during welding), excessive noise, moving machinery. 1.6 The system Consider the effect on the complete system of the work proposed. Will any proposed action (e.g. closing isolation valves, electrical isolation) put any other part of the system or any personnel at risk? Dangers might include isolation of vents or protective devices or the rendering ineffective of controls or alarms. Ensure isolation valves are turned on and off in a gradual way to avoid system shocks. 1.7w Pressure systems Ensure that any pressure is isolated and safely vented to atmospheric pressure. Consider double isolation (double block and bleed) and the locking or labelling of closed valves. Do not assume that the system has depressurised even when the pressure gauge indicates zero. 1.8. Temperature Allow time for temperature to normalise after isolation to avoid danger of burns. 1.9w Tools and consumables Before starting work ensure that you have suitable tools and / or consumables available. Use only genuine Spirax Sarco replacement parts. 1.10 Protective clothing Consider whether you and / or others in the vicinity require any protective clothing to protect against the hazards of, for example, chemicals, high / low temperature, radiation, noise, falling objects, and dangers to eyes and face. 1.11 Permits to work All work must be carried out or be supervised by a suitably competent person. Installation and operating personnel should be trained in the correct use of the product according to the Installation and Maintenance Instructions. Where a formal 'permit to work' system is in force it must be complied with. Where there is no such system, it is recommended that a responsible person should know what work is going on and, where necessary, arrange to have an assistant whose primary responsibility is safety. Post 'warning notices' if necessary. IM-UK-cFREME UK Issue 1 3

1.12 Handling Manual handling of large and / or heavy products may present a risk of injury. Lifting, pushing, pulling, carrying or supporting a load by bodily force can cause injury particularly to the back. You are advised to assess the risks taking into account the task, the individual, the load and the working environment and use the appropriate handling method depending on the circumstances of the work being done. Allow hot parts to cool before commencing work, to avoid the risk of burns. Always wear appropriate safety clothing before carrying out any installation or maintenance work. 1.13 Lifting (Figure 1) The Spirax compact FREME unit should be lifted by suitable lifting gear, from the base, placed in position and securely bolted to the floor. Please Note: - On no account is the Spirax compact FREME unit to be lifted by any other part, other than the base. - Sufficient space should be provided in its location to allow access for maintenance. - The FR-5000 unit occupies a maximum of 3.7 m³ space (Maximum footprint of 2.2 x 2.1 metres). - The FR-10000 occupies a maximum of 6.5 m³ space (Maximum footprint of 2.6 x 2.5 metres). - The FR-15000 occupies a maximum of 6.5 m³ space (Maximum footprint of 2.6 x 2.5 metres). 4 IM-UK-cFREME UK Issue 1

2. General product information 2.1 General information The Spirax compact FREME packaged flash steam and condensate recovery energy management system recovers the useful energy from condensate and transfers it back into the boiler feedwater. The system recovers heat energy from the condensate providing heat energy directly into the pump discharge side of the boiler feedwater. Heat can be recovered raising the feedwater temperature above 100ºC without causing any operational problems and minimum backpressure. A high proportion of this energy would otherwise have been lost. Spirax compact FREME systems can be sized for any feedwater flowrate up to 15,000 kg / h and are supplied fully assembled and pressure tested, ready for installation. The Spirax compact FREME Flash Recovery Energy Management unit consists of the following core items (Figure 1): A Condensate cooling fully welded plate & shell heat exchanger. B Control valve for condensate control. C Direct acting bellows sealed excess pressure valve. D Ancillary equipment that has not been specifically highlighted. Condensate inlet Note: For additional information about any particular product used in the construction of this unit see the relevant Technical Information Sheet. C Fig. 1 Water outlet A * * Condensate outlet Water inlet B 2.2 Identification The unit is available in the following package options: FR-5000 FR-10000 and FR-15000 IM-UK-cFREME UK Issue 1 5

3. Installation Warning: Before proceeding with any installation or maintenance work read Section 1, Safety information. 3.1 Firstly check that the unit and all its equipment has arrived as ordered and has not been damaged whilst in transit. 3.2 Determine the correct installation situation and the correct direction of fluid flow. 3.3 Remove protection covers from all connections and protective film from all name-plates, where appropriate, before installation on condensate or other high temperature applications. 3.4 Installation - Position the unit on the floor and bolt it down, ensuring that sufficient space is left for maintenance. 3.5 Piping connections - It should be ensured that all connecting pipework is stress free and adequately supported. The condensate supply should always be maintained at the specified design pressure and temperature for the unit. The Spirax compact FREME must not operate above the maximum pressures and temperatures indicated on the name-plate attached to the unit. The installation of an appropriately sized safety valve, to protect any lower pressured equipment is strongly recommended. Spirax Sarco supplies a range of traps, strainers, separators, safety valves and pressure reducing equipment. 3.6 Air supply If a pneumatic control system is installed, connect a compressed air supply (4.5 to 8 bar g (65 to 116 psi g)) to the pressure regulator mounted on the control valve. 3.7 Electrical supply All electrical wiring and connections should be carried out in accordance with National Regulations. A lockable isolator / switch disconnect should be fitted adjacent to the unit. Mains supply is directly connected to the primary side of the incoming control panel isolator (shown with the IP2X cover removed) and main earth terminal as shown in Figure 2. Q1 16A 1L2 3L2 5L2 PE 2T1 4T2 6T3 Fig. 2 6 Phase connection Neutral connection Earth connection IM-UK-cFREME UK Issue 1

3.8 Electrical specifications Electrical supply: Refer to the name-plate on the unit Control panel supply voltage Control panel load requirements Electrical control actuator Pneumatic control actuator 110 Vac / 60 Hz 240 Vac / 50 Hz Internally fused at 5 amps 24 Vac 4-20 ma control 4-20 ma control Note: Power supply 10-16 A 3.9 Electrical connections The following are available for customer connection to the Spirax compact FREME system if required: Volt free contacts Terminal designation Description Type 10 and 11 Enabled / running signal 12 and 13 High limit alarm 1 x N/O contact 1 x N/C contact 1 x N/O contact 1 x N/C contact Control panel Fig. 3 10 11 13 12 Volt free enable signal Volt free high limit alarm Customer to connect at the point of being commissioned into operation IM-UK-cFREME UK Issue 1 7

4. Commissioning We recommend the service and support of a Spirax Sarco Commissioning Engineer. Details of this service can be found by contacting Spirax Sarco. Note: In most new installations, dirt collects in the condensate line during construction of the piping systems. It is essential that the unit is flushed prior to commissioning. Commissioning procedure (see Figures 4 and 5): - Ensure that the control panel is powered - For the controller settings see the appropriate specific IMI supplied with the unit. - Shut the feedwater bypass valve (4). - Open feedwater isolating valves (3 and 5). - Open condensate outlet valve (6). - Open condensate bypass valve (2). - Check for water circulation through the Spirax compact FREME. - If the circulation is okay, slowly open the main condensate inlet valve (1) and close the condensate bypass valve (2). - Check that the outlet water temperatures are within acceptable values. - Check the operation of the condensate control valve (8). Important DEP excess pressure valve setting (7), if fitted: Setting the desired upstream pressure - The valve is supplied 'unset' with the spring adjuster at its lowest adjustment position. The upstream pressure may be set against either a 'dead end' condition or 'flowing' condition, depending on the requirements of the application, taking into account the effect of proportional offset. Details of setting can be found in the separate Installation and Maintenance Instructions, IM-S12-10, for the DEP Excess Pressure Valve. The Spirax compact FREME unit is now ready for service. Fig. 4 Side elevation of the Spirax compact FREME See the table at the top of page 9 for part identification 1 3 4 7 9 2 5 8 6 8 IM-UK-cFREME UK Issue 1

Item Description 1, 2, 3, 4, 5 and 6 Ball valves 7 Excess pressure valve 8 Control valve 9 Heat exchanger Condensate inlet 7 1 Water outlet 2 3 9 * * Condensate outlet 4 5 6 Water inlet 8 Fork lift Fork lift Fig. 5 Perspective view of a Spirax compact FREME Flash Recovery Energy Management unit IM-UK-cFREME UK Issue 1 9

5. Maintenance General For maintenance of the individual components that comprise the system, please see the product specific IMI s (Installation and Maintenance Instructions) supplied with the unit. Scale formulation Within open systems, where there is continual make-up water, there is a risk of scale formation. The extent of the scale will depend largely upon the water quality, which varies greatly from area to area. A test, conducted by a water treatment specialist, is recommended to determine the local quality and whether problems are foreseen. After extended service, the heat exchangers require cleaning. Regular chemical cleaning should be considered to remove scale. ¾" ports are available on the inlet and outlet piping of the heat exchanger allowing easy connection for 'Clean-in-Place' apparatus. Safe operation of this product can be guaranteed only if it is properly installed, commissioned, used and maintained by qualified personnel in compliance with the operating instructions. General installation and safety instructions for pipeline and plant construction, as well as the proper use of tools and safety equipment, must also be complied with. 10 IM-UK-cFREME UK Issue 1

IM-UK-cFREME UK Issue 1 11

12 IM-UK-cFREME UK Issue 1