FLOWMETER MODELS: 1MFA, 4MFA, 6MFA and 8MFA Series SAVE THESE INSTRUCTIONS

Similar documents
U S E R M A N U A L AIR FLOWMETER. MODELS: 1MFA2001 (shown) 1MFA9001 CAUTION. ISO Certified

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician.

U S E R M A N U A L CAUTION. Models: 19MFA Series. Federal (USA) law restricts this device to sale by or on the order of a physician.

ACRYLIC FLOW METERS 0-30, 0-70 & LPM

DRAFT U S E R M A N U A L CAUTION. Model: 19MFA1001 Series. Federal (USA) law restricts this device to sale by or on the order of a physician.

DFB FLOW METERS (DESIGNED FOR BLENDERS, DUAL TAPER)

U S E R M A N U A L. (CGA 870 Connection)

USER MANUAL SAVE THESE INSTRUCTIONS. For the most current manual revision, please visit our Website:

BlenderBuddy 2. Operating Manual & Instructions For Use ENGLISH R233M01 REV. A

U S E R M A N U A L. HELIUM-Oxygen Blender. (DISS and NIST Connections) Model No. PM5400 Series (shown) PM5500 Series SAVE THESE INSTRUCTIONS

USER MANUAL Series (CGA 870 Connections) SAVE THESE INSTRUCTIONS

USER MANUAL Series (Threaded Connections) SAVE THESE INSTRUCTIONS

U S E R M A N U A L. Model: PM4300 Series SAVE THESE INSTRUCTIONS

USER MANUAL. AIR-OXYGEN BLENDER (DISS and NIST Connections) Model No. PM5200 Series PM5300 Series (shown) SAVE THESE INSTRUCTIONS

USER MANUAL SAVE THESE INSTRUCTIONS. 300 Held Drive Tel: (+001) Northampton, PA USA Fax: (+001) ISO Certified

USER MANUAL SAVE THESE INSTRUCTIONS. Manuals available on our Website;

Operating and Maintenance Manual. Flowmeter

AND OPERATION INSTRUCTIONS

U S E R M A N U A L PM2200 SERIES SAVE THESE INSTRUCTIONS

U S E R M A N U A L PM2200 SERIES SAVE THESE INSTRUCTIONS

453 Series Steam Heated Vaporizing Regulator

- GAS REGULATOR - COMPACT STYLE

USER MANUAL PORTABLE OXYGEN CONCENTRATOR SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS

Dialflow Regulator. Instructions for Use

Oxygen Dialflow Meter. Instructions for Use

Pressure Regulator. Instructions for Use

HomeFill II Oxygen Conserving Cylinder

CLEMENTS. ANA Oxygen Regulator with Yoke Connector. User Manual. Manual No. ANA Issue 1

Micro Dial-Flowmeter. Instructions for Use

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator

AIR/OXYGEN BLENDER INSTRUCTION MANUAL

Pressure Regulators. Instructions for Use

CSA Sample Draw Aspirator Adapter Operator s Manual

Yoke Block Instruction Manual

RK-IR Sample Draw Aspirator Adapter Operator s Manual

PC7-C Flowmeter O2/N2O Sedation Unit Instruction Manual

APCO ASU-SCAV & ASU-CAV SINGLE BODY COMBINATION AIR VALVES

PORTER INSTRUMENT COMPANY, INC.

Cocoa Patio Pond with Lit Spillway

Oxygen Dialflow Meter. Instructions for Use

Operating Instructions for BAIR22-6 AIR-POWERED CRIMPING TOOL

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

453 Series Steam Heated Vaporizing Regulator

Pressure Relief Valve Instruction Manual

TactAir PCP Fill Kit/Adapter. Operation Manual

PRESSURE REDUCING STATION INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

RK LEL Sample Draw Aspirator Adapter Operator s Manual

Operating Manual. Models AQT-02 & AQT-COO2 Manual No. MON004 (Rev 2 April 2000)

Push-To-Set Intermittent Suction Unit (PTS-ISU) Instructions for Use

High Pressure Inlet Kits for CONCOA BlendMites and BlendMasters

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company

2 CYLINDER MOBILE CART USER S MANUAL / INSTRUCTIONS

Operating Instruction Manual for Liquid Nitrogen Containers. CRY/CRYC Series. Hagavish st. Israel Tel: , Fax:

Domiciliary Oxygen Switch. Instructions for Use

Yoke Block Instruction Manual

Operators Manual. Supera Floor Stand Anesthesia Machine M1000. Models: M1000 Basic Non-rebreathing M1200 Basic M1200

Portable Compressed CO 2 Regulator

UNIVERSAL TUBE HOLDER SYSTEM

CP-D/CP-M Circular Polarizer for Phoroptor. User s Guide

MEDICAL REGULATOR RANGE (MEDIREG RANGE)

INSTRUCTIONS PARTS LIST

FLANGED TWO-PIECE BALL VALVES

USER MANUAL. SAVE THESE INSTRUCTIONS (For latest revision, go to

INSTRUCTIONS FOR MODEL SG6500 GAS HEATERS

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

Certified ISO 9000 INSTALLATION AND OPERATION INSTRUCTIONS. Before Installing or Operating, Read and Comply with These Instructions

92831 TEL: (714) FAX:

6 & 8 Bubble Panel Installation Manual

WARNING NOTES TABLE OF CONTENTS

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

Instructions for Cleaning & Maintaining Air Compressor

WEATHERIZING INSTRUCTIONS

GM-7000 Series CE Approved Gas Control Valve

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

CPX EMERGENCY STANDBY MANIFOLD INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

Model ASSEMBLY and OPERATING INSTRUCTIONS

Cylinder Tilt Saddle Instruction Manual

Helium-Oxygen Blender

623 Series Dome Load Regulators

PIPETMAN F ENGLISH. Other languages available on our website:

Operation Manual. O2 Quickstick. Oxygen Analyzer 08.17

Rev. B. Operating Instructions

HoverJack. Air Patient Lift. Equipment Manual. From HoverTech International. Issued: June 1,

SERVICE LETTER WARRANTY CONDITIONS FOR ROTAX

Instruction Sheet. SUPERSEDES: New EFFECTIVE: August 1, 2013

Operation Manual. O2 Quickstick. Oxygen Analyzer

TABLE OF CONTENTS. Copyright 2010 Precision Medical, Inc. 10m 11/10 Printed in USA

MACS Mask CPAP System

User Operation Manual and Safety Instructions

GE Oil & Gas Model. Masoneilan* Air Lock-up Valve Instruction Manual. GE Data Classification : Public

Operating Manual. Check and Go Disposable Medical Depot, Inc Port Washington N.Y

200 PSI FAST-FILL AIR SOURCE KIT

AIR INLINE METAL SHEAR

Blendox AII5000F Inhalation Antalgic System. User s Manual :SP-Y Series No. Version :A1. Date of Review:

UltraMaxO OXYGEN ANALYZER OPERATING MANUAL & INSTRUCTIONS FOR USE R221P11. R221M11 Rev. C

Operating Manual CBA Series Cascade Breathing Air Assemblies

Transcription:

USER MANUAL FLOWMETER MODELS: 1MFA, 4MFA, 6MFA and 8MFA Series 1MFA3001 (Shown) 8MFA1001 (Shown) SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician. 300 Held Drive Tel: (+001) 610-262-6090 Northampton, PA 18067 USA Fax: (+001) 610-262-6080 ISO 13485 Certified www.precisionmedical.com

RECEIVING / INSPECTION Remove the Precision Medical, Inc. Flowmeter from the packaging and inspect for damage. If there is any damage, DO NOT USE and contact your Provider. INTENDED USE The Flowmeter is intended for use by physicians, respiratory therapists and other authorized hospital personnel to administer selected doses of medical gases to a patient. READ ALL INSTRUCTIONS BEFORE USING This manual instructs a Professional to install and operate the Flowmeter. This is provided for your safety and to prevent damage to the Flowmeter. If you do not understand this manual, DO NOT USE the Flowmeter and contact your Provider. SAFETY INFORMATION - WARNINGS AND Indicates a potentially hazardous situation which, if WARNING not avoided, could result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. Used without the safety alert symbol indicates a potentially hazardous situation which, if not avoided, may result in property damage. Operating Instructions Symbol for USE NO OIL Symbol indicates the device complies with the requirements of Directive 93/42/EEC concerning medical devices and all applicable International Standards. (On CE marked Devices ONLY)

WARNING Use Flowmeters only for their Intended Use as described in this manual. ALWAYS confirm prescribed flow before administering to patient and monitor flow on a frequent basis. Flowmeters may contain magnetic, ferrous material that may affect the results of an MRI. To Reduce the Risk of Fire or Explosion: ALWAYS follow ANSI and CGA standards for Medical Gas Products and Flowmeters and Oxygen Handling. DO NOT use or store oils, greases, organic lubricants or any combustible materials on or near this Flowmeter. DO NOT use near any type of flame or flammable/explosive substances, vapors or atmosphere. DO NOT smoke in an area where oxygen is being administered. Flowmeters must be operated with the Flow Tube in a vertical, upright position. Only personnel instructed and trained in its use should operate this Flowmeter. Ensure all connections are tight and leak free. Only use oxygen-safe leak detector. DO NOT autoclave. DO NOT gas sterilize with EtO (Ethylene Oxide). DO NOT clean with aromatic hydrocarbons. DO NOT immerse Flowmeter in any kind of liquid. This will void the warranty. The 1MFA3001, 4MFA1001 & 6MFA1001 Flowmeters may have a factory installed restrictor. Prior to use, check Flowmeter labeling for flow restrictions. The 1MFA3001, 4MFA1001 & 6MFA1001 Flowmeters contain a glass Flow Tube which is fragile. Special care should be observed to avoid breaking the Flow Tube. (Continued on Inside)

SPECIFICATIONS Flow Range Graduations Accuracy 0 200 cc 20 cc (0-200) 0-100 cc ±10 cc 101-200 cc ±14 cc 0 1 l/min.1 (0-1) l/min 0-1 ±.05 l/min 0 3.5 l/min.125 (0-1) l/min.25 (1-3.5) l/min 0-3.5 ±.15 l/min 0 5 l/min.25 (0-5) l/min 0-5 ±.20 l/min 0 6 l/min.5 (0-6) l/min 0-6 ±.50 l/min 0 8 l/min.5 (0-8) l/min 0-8 ±.25 l/min 0 15 l/min.5 (0-5) l/min 0-5 ±.25 l/min 1 (5-15) l/min 6-15 ±.50 l/min 0 26 l/min 1 (2-26) l/min 2-4 ±.50 l/min 5-26 ±10% of reading 0 70 l/min 5 (0-70) l/min 0-70 ±10% of reading Flush Flow is the output of the flowmeter when the flow indicator is beyond the highest calibrated graduation. The Flush Flow range is as indicated on the flowmeter labeling. Transport / Storage Requirements -40 F (-40 C) to 140 F (60 C) The gas and inlet pressures are indicated on the Flow Tube or Flowmeter body. NOTE: Storage / Transport outside the specified range may cause damage to the flowmeter. The effect on accuracy of flow due to variations in ambient temperature is standard accuracy +7.3% @ 32 F (0 C) and -3.0% @ 104 F (40 C). The above Flowmeter models are calibrated at specified inlet pressure, 70 F (21 C), standard atmospheric pressure. International models are calibrated per specifications marked on Flow Tube or Flowmeter body. Specifications are subject to change without prior notice. For the most current manual revision please visit our website: www.precisionmedical.com Tell us how we are doing! Visit us at www.precisionmedical.com

OPERATING INSTRUCTIONS WARNING Read this User Manual before installing or operating the Flowmeter. Inspect the Flowmeter for visual damage before use, DO NOT USE if damaged. NOTE: Precision Medical, Inc. strongly recommends the use of kink proof Cannula. 1. Turn Knob to the OFF position. 2. Connect the Flowmeter to the appropriate gas source. The appropriate gas and pressure are specified on the Flow Tube or Flowmeter body. 3. Verify that the Float Ball is at the very bottom of the Flow Tube. NOTE: If the Float is not resting at the bottom of the Flow Tube, the product is leaking; consult the TROUBLESHOOTING Guide. 4. Adjust Flow: To increase - Turn Knob counterclockwise To decrease - Turn Knob clockwise 5. Set flow by aligning center of Float Ball with indicator lines on the Flow Tube. 6. Adjusting flow beyond the last calibrated indicator line will result in an undetermined flow. 7. To obtain maximum flush flow, turn Knob fully Counterclockwise. NOTE: Flush flow is any flow above the last calibrated line on the Flow Tube with an unrestricted flow, as indicated on flowmeter labeling.

TROUBLESHOOTING If the Flowmeter fails to function, consult your Provider or Precision Medical, Inc. Problem Probable Cause Remedy Will not shut off Leak Defective Valve Replace Tetraseal and/or Housing Replace Body Assembly Sticking Float Ball Debris in Flow Tube Clean Flow Tube & Float Ball Unable to set desired flow Blocked Inlet DO NOT over tighten Knob when turning off. This will cause damage to the Flowmeter. Pressures other than those indicated on the Flow Tube or Flowmeter body may affect the accuracy of the indicated flow. Gas Temperatures other than 70 F (21 C) may affect the accuracy of the indicated flow. Attaching accessories to the outlet (which may increase resistance to outlet flow) may change indicated flow but will not affect the accuracy of the flow. ONLY use appropriate gas specific indexed fittings to connect Flowmeter to gas source. Use Oxygen connections for oxygen Flowmeters; use air connections for air Flowmeters. DO NOT attempt to repair the 8MFA Flowmeters. There are no serviceable parts. CLEANING INSTRUCTIONS 1. Disconnect all connections before cleaning. 2. Clean exterior surfaces of the Flowmeter with a cloth dampened with a mild detergent and water. 3. Wipe dry with a clean cloth. Replace Body Assembly Knob will not turn Valve seized Replace Body Assembly 8MFA Models DO NOT have serviceable parts. RETURNS Returned products require a Returned Goods Authorization (RGA) number. Any product returned to Precision Medical, Inc. must be packaged in a sealed container to prevent damage. Precision Medical, Inc. will not be responsible for goods damaged in transit. Return Policy available on the Internet, www.precisionmedical.com.

REPLACEMENT PARTS * PART MODEL # 6MFA 4MFA 1MFA 1001 3001 3501 4001 1001 8001 5001 1101 1211 2001 9001 Spring NA 1575 NA Washer NA 1787 NA Disc NA 1009 1114 1009 1114 1009 Housing 1143 Tetraseal 1123 Flow Tube Kit # 503213 Kit # 503214 Kit # 503215 1012 1152 1010 1021 502459 507573 502117 1011 1031 Float Ball 1576 1005 1029 1005 1154 1154 1005 1029 Body Assembly 1891 1897 502053 505271 504407 504823 504407 504434 504824 Knob 1007 1008 Holder 506176 NA * 8MFA Models DO NOT have serviceable parts. International parts specifications and specific ratings are available upon request. DECLARATION OF CONFORMITY Precision Medical, Inc. 300 Held Drive Northampton, PA 18067, USA Emergo Europe (European Office) Molenstraat 15 2513 BH, The Hague The Netherlands Phone: +31 (0) 70.345.8570 Fax: +31 (0) 70.346.7299 Flowmeters 1MFA, 4MFA, 6MFA & 8MFA Series Classification: IIa Classification criteria: Clause 3.2 Rule 11 of Annex IX of MDD We hereby declare that an examination of the under mentioned production quality assurance system has been carried out following the requirements of the UK national legislation to which the undersigned is subjected, transposing Annex II, 3 of the Directive 93/42/EEC and Directive 2007/47/EC on medical devices. We certify that the production quality system conforms to the relevant provisions of the aforementioned legislation, and the result entitles the organization to use the CE 0473 marking on those products listed above. Applied Standards: EN 1041, EN 14971, EN ISO 13485, ISO 15001, ISO 15002, ISO 15223-1 Notified Body: AMTAC Certification Services Limited Address: Davy Avenue Knowlhill Milton Keynes MK5 8NL, UK Certification Registration No s: 1126 CE Date of Expiry: 03 August 2017 Devices already manufactured: S/N traceability Device History Records Validity of DOC: 04 August 2012 to Date of Expiry Manufacture Representative: Quality Manager Position: Quality Systems/ISO Representative Date of Issue: 04 August 2012

LIMITED WARRANTY AND LIMITATION OF LIABILITY Precision Medical, Inc. warrants that the Medical Gas Flowmeter (the Product) will be free of defects in workmanship and/or material for the following period: (a) Flow Tube and Housing Lifetime of the product (b) Needle Valve Five (5) years from shipment (c) All other parts of the Medical One (1) year from shipment Gas Flowmeter not identified in (a) or (b) above Warranty does not cover breakage / abuse. Should any failure to conform to this warranty appear within the applicable period, Precision Medical, Inc. shall, upon written notification thereof and substantiation that the goods have been stored, installed, maintained and operated in accordance with Precision Medical, Inc. s instructions and standard industry practice, and that no modifications, substitutions, or alterations have been made to the goods, correct such defect by suitable repair or replacement at its own expense. ORAL STATEMENTS DO NOT CONSTITUTE WARRANTIES. The representative of Precision Medical, Inc. or any retailers are not authorized to make oral warranties about the merchandise described in this contract, and any such statements shall not be relied upon and are not part of the contract for sale. Thus, this writing is a final, complete and exclusive statement of the terms of that contract. THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR OTHER WARRANTY OF QUALITY, WHETHER EXPRESS OR IMPLIED. Precision Medical, Inc. shall not under any circumstances be liable for special, incidental or consequential damages including but not limited to lost profits, lost sales, or injury to person or property. Correction of non-conformities as provided above shall constitute fulfillment of all liabilities of Precision Medical, Inc. whether based on contract, negligence, strict tort or otherwise. Precision Medical, Inc. reserves the right to discontinue manufacture of any product or change product materials, designs, or specifications without notice. Precision Medical, Inc. reserves the right to correct clerical or typographical errors without penalty. 503349 rev5 [t4] 8/14 (?M) Printed in USA