Vacuum grease can be applied to Warner chambers by use of a small artist s dotting brush or a syringe. Both approaches are described below.

Similar documents
Vacuum grease can be applied to Warner chambers by use of a syringe or a small artist s dotting brush. Both approaches are described below.

Application of vacuum grease

SERIES 20 CHAMBERS THE RC-25 AND RC-25F CHAMBERS ASSEMBLY

THE RC-26GLP CHAMBER RC-26GLP RC-26G

SERIES 20 CHAMBERS THE RC-20 AND RC-20H CHAMBER ASSEMBLY

SERIES 20 CHAMBERS THE RC-26, RC-26P AND RC-26G CHAMBERS ASSEMBLY

Warner Instruments, Inc Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

QE-1, Rev Warner Instruments, Inc Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &

BPS-2, Rev TABLE OF CONTENTS

User s Guide. Vacuum Controller for liquid delivery systems

INSTRUCTION MANUAL. January 23, 2003, Revision 0

Instruction Manual Updated 7/26/2011 Ver. 2.2

User s Guide. Pressure Controller for liquid delivery systems

Pneumatic spool valve islands

Model # HC-MIS INSTRUCTION MANUAL

OPERATING INSTRUCTIONS

BioAerosol Nebulizing Generator. Operation and Maintenance User Manual

Thanks for choosing EJAI SOLAR product

TJF-Q180V Cleaning and Disinfection Checklist

User's Manual. MixRite TF 10. Edition 05.08

TJF-Q180V Cleaning and Disinfection Checklist

PH01 Perfusion Cannula Manual

Installing ASI Umbilical Delivery Systems

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

Model VR6 System. Installation, Operation & Maintenance

GREIG FILTERS, INC. OPERATION MANUAL

Domiciliary Oxygen Switch. Instructions for Use

Right-Angle Tube Roller Model

GM Series Dual-Block Multi-Function Gas Control Valves

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

Pressure Dump Valve Service Kit for Series 3000 Units

WELLS JOHNSON HIGH VOLUME CANISTERS

Pressure Dump Valve Service Kit for Series 2300 Units

Unisense In Situ UniAmp Connector System

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

Microscopy Cryogenic WORKSTATION. Performance by Design

Live cell imaging handbook & Catalogue Vol. 6.2

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

TECHNICAL DATA. Q = C v P S

Depth sensor. Product reference : REV 1. USER GUIDE and INSTALLATION GUIDE. nke Sailing competition

3190A NEO-ANGLE DOOR INSTALLATION INSTRUCTIONS. Series MODEL NO

Continental Industries TRANSITION FITTINGS or FAX Visit

Polatrak ROV II - Tip Contact Probe Operation Manual

tel: fax: web:

User Manual November 2014

Agilent 1290 Infinity Pump Head Maintenance

1. A proper preparation of the cone and other material is inevitable prior to a CPTU test.

Basic Flows in a Microfluidic Device

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

TECHNICAL DATA. Q= Cv S

Pneumatic valve islands

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

Met One E-BAM Particulate Monitor

G96 Series BASOTROL Dual Operator Valve

SUMMITTM 400 & 600. Natural Gas Barbecues. Step-By-Step Guide

Radnoti Liver Perfusion System

OPERATING MANUAL FOR ALL MODELS OF EASY-LOAD PUMP HEADS

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

ALE-40. R06 Miniature Brass Body Regulator. Water and Compressed Air Service 1/8" and 1/4" PTF Port Sizes. Air line equipment.

MEMBRANE CHAMBER MC. Innovative Engineering for Science

Installation Instructions

Instruction Manual. Coverslip Clamp Chambers

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

QUICK START GUIDE TO DRINKING WATER MONITORING

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION

Bull s-eye Levels and Screw-On Levels

Gas Lines. Technical Manual. Sumitomo (SHI) Cryogenics of America, Inc Vultee Street Allentown, PA U.S.A.

G92 Series BASOTROL Automatic Pilot Gas Valve

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

Flow controller Type ED/CCB311 Instruction manual

Dual Solenoid Gas Valve Installation

OWNER S TECHNICAL MANUAL

Connectors. SECTION 2 OF 3 SECTIONS ON CONNECTORS VHP Tees and Crosses. Top Seller SEE STARRED PRODUCTS. VHP Tees & Crosses for Capillary Tubing

OPERATING MANUAL EASY-LOAD PUMP HEADS

Santa Fe Cycles Assembly Guide Introduction

INSTALLATION & MAINTENANCE INSTRUCTION

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL

Installation Procedure for your Disco Double Kit, by Airgun Lab, LLC.

Valve INV-907. Instructions. 1 Introduction. 2 Installation. Safety. Unpacking. Installing the valve

Multi-Probe Sampling System User Guide & Manual

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

Hand lever valves VHER

Oxygen Dialflow Meter. Instructions for Use

Air Operated Hydraulic Pumping Systems to 50,000 psi

12S 1st Stage. -Maintenance Procedure-

Precision and Instrument Regulators 1/4" port size

Trilogy Theory of Operation

CS Controlled Dissolved Gas assembly with optional CS Air Aspirator assembly. Installation and Operation information

GROUTEC SCOTT VICKERS. Grouting Equipment

UNITY 2. Uni-DAAMS Manual. Version 1.3 (Changes to Section 1.1) March 2010

Gas Sampling Fitting with MK2.1 and L-Probe

INSTALLATION MANUAL JAPANESE ENGLISH GERMAN FRENCH ITALIAN SPANISH. Before installation. Installation INSTALLATION MANUAL: B700

OPERATING MANUAL EASY-LOAD PUMP HEADS

Single UNO. Incubator. .com. Main Features: Incubating chamber. of a Multi Well plate. Manual Air/CO 2 mixer. operation.

SWIRLFLO Refrigerated fountains with FLEXI-GUARD

HumiSys HF High Flow RH Generator

Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems

How to Order RM0 0 Z. IN/OUT fitting type Metric size Inch size Straight Elbow Straight Elbow Straight Elbow Straight Elbow ø ø ø ø ø ø ø ø ø/ ø/ ø/ ø

INSTALLATION, MAINTENANCE & OPERATING INSTRUCTIONS 2-4 REDUCED PORT/ FULL PORT (5700/6700) ANSI CLASS 150/300/600/900/1500/2500 TRUNNION BALL VALVES

Transcription:

Series 20 Chamber Instructions Model RC-21BRFS Closed Bath Imaging Chamber with Field Stimulation SERIES 20 CHAMBERS A feature in common with all Series 20 chambers is the use of a glass coverslip for the floor of the chamber. In most cases, this same coverslip contains the imaging sample. When viewed with inverted microscopes, images are visualized through a single thickness of glass, usually 0.13-0.17 mm. (#1) THE RC-21BRFS CHAMBER The RC-21BRFS is a closed bath imaging chamber incorporating field stimulation electrodes. A pair of platinum wires is epoxied into the parallel sides of the oval shaped bath and the connecting wires terminate in 1 mm pins. The chamber is sealed on both the top and bottom with 25 mm round coverslips. The bath volume of the completed assembly is 260 µl. The chamber features an injection port adjacent to the bath solution input port for direct introduction of substances or removal of bubbles. The chamber also features a back-pressure control on the solution output port. ASSEMBLY A general procedure for the assembly of a Series 20 chamber is to first apply a coverslip to the chamber bottom and then place the assembly in the appropriate platform. The platform serves to (1) clamp the assembly together providing a tight seal between the chamber and coverslip and (2) provide a means to mount the chamber onto the microscope stage, usually via a microscope specific adapter plate. The RC-21BRFS differs from this procedure in that there is an additional coverslip mounted on the top of the chamber to provide an enclosed volume. Application of vacuum grease Vacuum grease can be applied to Warner chambers by use of a small artist s dotting brush or a syringe. Both approaches are described below. NOTE: Prior to beginning assembly make sure all required components are available and thoroughly cleaned. Be sure to remove any old vacuum grease from the perfusion channels and input/output ports. Brush technique The brush technique is performed in a similar manner as described above except that the vacuum grease is applied using a #1 or #2 artist s dotting brush. Brushes can be found in your local art shop, university bookstore, or can be purchased from Warner. 1

NOTE: We suggest the brush technique since the resultant application of vacuum grease is more precise. Syringe technique Begin by loading a 1cc syringe with a small quantity of vacuum grease. The use of a needle is unnecessary and undesirable. Using the syringe, apply a small bead of grease to the chamber as described below. Evenly distribute the grease by placing a spare coverslip into place and gently pressing it into position. Remove and discard the spare coverslip and clean away any grease which may have entered the bath area. Pay particular attention to the perfusion input and outlet ports since the presence of grease in these areas will impede the flow of perfusate. Assembling the Chamber 1. Using the brush or the 1 cc syringe, apply a small bead of grease around the seat which the top coverslip rests upon. Place the appropriate coverslip into the chamber top and gently press it into position to evenly distribute the grease around the seat. 2. Remove and discard the used coverslip. Clean away any grease which may have entered the bath area. Pay particular attention to the perfusion input and outlet ports since the presence of grease in these areas will impede the flow of perfusate. 3. Using the brush or the 1 cc syringe, apply a small bead of grease to the coverslip groove on the bottom of the chamber. Evenly distribute the grease around the seat by placing appropriate glass coverslip onto the chamber bottom and gently pressing it into position. Remove and discard this coverslip. As before, inspect the chamber and remove any grease from the bath area and perfusion ports. NOTE: You may wish to first test fit coverslips into place to determine the best area to apply the grease bead. 4. The chamber is now primed to accept both top and bottom coverslips. Installing the chamber bottom 1. Place the sample-containing coverslip (sample side up) into the provided recess on the bottom of the chamber. 2

2. Check that the coverslip is seated properly and that the droplet of buffer covering the sample is centered on the coverslip. 3. Place the partially assembled chamber into the platform (this should be a P-2, PH-2 or PM-2 platform). Pre-filling the perfusion lines 1. The perfusing solution is delivered through 1/16" OD polyethylene tubing which is attached to the inlet and exit ports. 2. Make attachments as described in the section labeled Perfusion and run a small amount of perfusate through both the inlet and exit ports. This will reduce the introduction of bubbles after the top coverslip is attached. Installing the chamber top 1. Prior to placing the top coverslip into place, fill the bath area with solution. This can be achieved either by introducing perfusate through the inlet port or by pipetting directly into the bath area. 2. Using aspiration, remove any excess fluid from the greased coverslip/chamber interface. Take care to not disturb the grease seal. 3. Place a clean coverslip in the greased chamber top. The final seal is achieved by mounting the platform top. If you are using a P-2 or a PH-2 platform, tighten using the 4 Phillips head screws. Filling the chamber assembly 1. If the bath area is not completely filled, additional solution can be injected via the perfusion input port. 2. Air bubbles can be removed by applying suction with a syringe to the metal access tube next to the input port. 3. Check the chamber for leaks. Attaching the electrode leads 1. Attach the green electrode leads to the assembled chamber/platform prior to mounting it to the microscope. NOTE: Use care when connecting the green wire leads to the chamber body. The contacts within the plug are fragile. 2. Once the platform is mounted to the microscope stage you can make further attachment to your electronics. Mounting onto the microscope The assembled Series 20 chamber/platform can be mounted directly onto a microscope stage if the stage is both flat and has a cutout smaller than the platform. In most cases, however, the stage cutout is larger than the platform necessitating the use of a stage adapter. In addition, a stage adapter is highly recommended if the platform is to be heated since it provides insulation between the platform and microscope stage. Warner Instruments stocks stage adapters for most popular microscopes (see Appendix A) and we will custom manufacture adapters for special applications. Contact our Sales Department for details. 3

PERFUSION Perfusate is delivered to the chamber through 1/16" OD polyethylene tubing (PE-160, available from Warner Instruments). A tubing sample is inserted into the chamber during shipping to identify the input port. Insertion of perfusion tubing to the input port can be greatly simplified by cutting the end of the tube on a bias rather than with a square face. We recommend pre-filling tubing with buffer before insertion as this will reduce the occurrence of bubbles in the flow path. Fluid control Solution source selection and rate of delivery can be of either of manual or automatic design and is left to the user. However, Warner Instruments manufactures several perfusion control systems (e.g., the valve-driven VC-6 and VC-8 Control Systems, both of which can be used for this application). Finally, a reference by Trese Leinders-Zufall describing the advantages of various perfusion control systems is available for download from the related files section of this product s page on our website. You can find this and other references at http://www.warneronline.com/product_info.cfm?id=731. Multiple perfusion solutions Warner Instruments multi-port manifolds (MP Series) can be used to connect up to 8 solution lines to the Series 20 chambers. Input and output ports on the MP series manifolds are designed to accept PE-160 tubing. Tubing ends should be cut on an angle before insertion and pushed in as far as they will go. Air can be removed from each feed line by pre-filling with its appropriate solution. Finally, the manifold output tube is attached to the input port of the chamber. We recommend making the connection between the manifold exit port and chamber input port as short as possible to minimize solution exchange times. Suction/Level control Removal of solution from Series 20 chambers is usually performed by aspiration. We recommend the use of a vacuum trap to avoid introduction of aspirant into your house vacuum lines. In general, suction tubing is installed in a slot in the suction reservoir wall allowing adjustment of the fluid level in the main body of the chamber. Adjust the vacuum until the suction rate is equal to the flow rate into the chamber. PLATFORM HEATING A general discussion regarding issues surrounding heating of solutions and Warner platforms is available for download on our website. (http://www.warneronline.com/product_info.cfm?id=747) Monitoring the heat Heat is transferred to the aluminum platform from a pair of 20 Ω power resistors, one mounted on each side of the platform. Heater platforms are supplied with a thermistor assembly and non-heater platforms can be upgraded by ordering a CC-28 Cable Assembly. The temperature of the platform is monitored by measuring the platform thermistor resistance and adjusting the voltage to the heaters. A second temperature sensing device, such as a thermistor, can be placed in the bath to directly monitor the solution temperature. Automatic heat control is achieved by using either a Warner TC-324B or TC-344B Temperature Controller (single or dual channel models, respectively). These devices allow either the platform or solution thermistor to be selected as the control sensor. The desired temperature is set and automatically maintained at less than 1 C deviation. 4

Thermistor information The maximum temperature rating of the supplied thermistor is 60 C. The thermistor assembly is inserted into the small hole drilled in the side of the platform. NOTE: If the thermistor fits loosely in the hole, use a drop of oil (immersion or mineral), or alternatively vacuum grease, to insure good thermal transfer. MAINTENANCE Cleaning of polycarbonate chambers should be performed using a dilute detergent solution. Alternatively, Warner instruments has developed a trisodium phosphate (TSP) wash protocol which gives very good results. Contact our Technical Support staff or download the protocol in PDF format from our website. (http://www.warneronline.com/pdf/whitepapers/cleaning_plastic.pdf) NOTE: Do not use alcohol, ether or other solvents on plastic parts. Solvents may be used on the anodized surfaces of the platforms. All chamber parts may be autoclaved. 5

APPENDIX A. Warner Stage Adapters Warner Instruments carries an extensive line of stage adapters for our Series 20 chambers and we are constantly adding new adapters as microscope manufacturers add to or modify their product lines. Please contact our offices if you do not find an adapter for your microscope in the list below. You may also want to check our website (http://www.warneronline.com/product_info.cfm?id=711) to see if an adapter has been added since this manual was printed. Nikon Olympus Leica Zeiss Prior & Ludl Manufacturer Microscope Model Stage Adapter Order No. Nikon Diaphot / TE200 / TE300 / TE2000 SA-NIK 64-0291 Nikon TMS with 8x12 cm Cutout SA-TMS/8 64-0292 Nikon TMS with 9x13 cm Cutout SA-TMS/9 64-0293 Nikon E400 / E600 / E800 SA-20UU 64-0298 Nikon Eclipse TS100 SA-TS100 64-0340 Olympus IMT SA-OLY 64-0294 Olympus BX-40 / BX-50 / BX-51 / BX-61 SA-20UU 64-0298 Olympus IMT-2 / IX-50 / IX-70 / IX-71 / IX-51 / IX-81 SA-OLY/2 64-0295 Burleigh Gibraltar Stainless Steel Stage Leica-MicroSystems DMIL with Object Guide SA-20LZ 64-0296 Leica-MicroSystems DMIRB/E with Plane Stage Leica-MicroSystems DMIRB/E SA-20L3P 64-0301 with 3-plate Mechanical Stage Zeiss Axiovert with 85x130 Mechanical Stage SA-20KZ 64-0297 Zeiss Axiovert 100M, 200M Zeiss Axiovert with 211x230 Specimen Stage SA-20LZ 64-0296 Zeiss Axiovert 25, 35, 100, 200 Zeiss Axioskop with 75x30 Mechanical Stage SA-20UUZ 64-0336 Zeiss Axioskop LSM 510 Zeiss with 3-plate Mechanical Stage SA-20L3P 64-0301 Prior & Ludl Motorized Stage on Upright Scope SA-20PL 64-0299 Prior & Ludl Motorized Stage on Inverted Scope SA-20PLI 64-0300 HAI HAI 900 Inverted Microscope SA-HAI 900 64-0302 Burleigh Burleigh Gibraltar Stainless Steel Stage SA-OLY/2 64-0295 Gibraltar Burleigh Gibraltar Aluminum Stage SA-OLY/3 64-0386 NOTE: Warner Instrument Series P or Series PH platforms are designed to fit the Zeiss 76x26 microscope slide frame (#471719) without the use of a stage adapter. All Series PM platforms require a stage adapter. In general, all heater platforms work best with an insulating material between the platform and frame. 6

B. Chamber supplies/spare parts We stock a large selection of supplies for use with Warner chambers. A partial listing of several parts are shown below. Please consult our catalog or website for items not included. Contact our Sales Department for special needs or prices. Part Number Order No. Description Qty/pkg #1 Coverslips CS-25R 64-0705 25 mm diameter round 100 Polyethylene Tubing PE-160/10 64-0755 0.045" x 0.062" (ID x OD) tubing (1.57mm x 1.14mm) 10 ft. (3.3 m) PE-160/100 64-0756 0.045" x 0.062" (ID x OD) tubing (1.57mm x 1.14mm) 100 ft.(33 m) Platforms P-2 64-0278 P-2 platform for Series 20 chambers, non-heater 1 PH-2 64-0285 PH-2 platform for Series 20 chambers, heater 1 PM-2 64-1561 PM-2 Chamber platform with magnetic clamps 1 Replacement/Spare Parts for Heater Platforms CC-28 64-0106 Heater Cable Assembly 1 TS-60P 64-0269 Replacement Control Thermistor 1 TS-70B 64-0276 Replacement Monitor Thermistor 1 Multi-Perfusion Zero Dead Space Manifolds MP-2 64-0206 2 input, 1 output 1 MP-3 64-0207 3 input, 1 output 1 MP-4 64-0208 4 input, 1 output 1 MP-5 64-0209 5 input, 1 output 1 MP-6 64-0210 6 input, 1 output 1 MP-8 64-0211 8 input, 1 output 1 Accessories 111-Kit 64-0378 Silicone Lubricant Kit 1 C. Comments 1) Best temperature regulation is achieved by preheating your solution with an in-line heater (e.g., Warner Fast-flow SH-27B or Slow-flow SF-28) in addition to directly warming the chamber platform. 7

D. Specifications 8