Anesthesia Machine Intro

Similar documents
Anes Machine Use and Pre-use Check - CA1 focus

Anesthesia Delivery Systems What Do I Need to Know About My Machine? A Workshop James H. Philip, MEE, MD, CCE

New Anesthesia Delivery Systems What Do I Need to Know About My New Machine?

Draeger Fabius GS Pre-Use Check

Fabius will not compensate for Lung Compliance or Changes in lung compliance

Technology Topics 2017 James H Philip MEE, MD, CCE page 1

VIMA. (Volatile Induction and Maintenance Anesthesia) How and Why. James H. Philip M.E.(E), M.D.

Anesthesiology Research and Scholarship. Follow this and additional works at:

Working version subject to Departmental approval. Drafted by Dr. Olympio and reviewed by clinical members of The Capital Equipment Committee

Flow meter. bellow vaporizer. APL valve. Scavenging system

Recommendations on Checking Anaesthesia Delivery Systems

HONG KONG COLLEGE OF ANAESTHESIOLOGISTS TECHNICAL GUIDINES RECOMMENDATIONS ON CHECKING ANAESTHESIA DELIVERY SYSTEMS

Hallowell EMC 2000 and 2002 Veterinary Ventilator Set-up, Use, and Troubleshooting

Anesthesia Machines. Inhaled Anesthetic Agents

GE Healthcare. Aestiva/5. More than superior ventilation

Aespire 7100 Essential performance Compact design

The Anesthesia Machine (con t) The primary cause of machine malfunction is failure to check Never start without the American Express items What is the

S/5 Aespire. Quick Reference Guide

Fabius Tiro TM. Designed for your environment. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Fabius Tiro TM. Designed for your environment. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products

THE GE AISYS ANAESTHETIC MACHINE

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings

Operators Manual. Supera Floor Stand Anesthesia Machine M1000. Models: M1000 Basic Non-rebreathing M1200 Basic M1200

Keeping anaesthetic pollution to minimum in theatre environment

Hallowell EMC Vacuum / Scavenging Interface

A9600 Anesthesia Workstation. Your healthcare, we care.

Narkomed MRI-2. A perfect fit for the MRI environment. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Checking a Breathing System

Hallowell EMC Anesthesia WorkStation Operating Manual

What our equipment teaches us

Breathing Systems. Professor Khalid Bashir

Anesthesia. Midmark Animal Health Products

Comparison Of The Efficacy Of Two Low Fresh Gas Flow Techniques In Low Flow Anaesthesia

Anesthesia Workstation

Selecting and Connecting Breathing Systems

GE Healthcare. Avance Carestation. Upgrade promotions guide

Table Top and Convertible Anesthesia Machine Models: M3000 and M3100 (SHOWN WITH OPTIONAL EQUIPMENT)

Operators Manual. Supera Wall Mount Anesthesia Machines. Models: M2300 M2500. (All shown with optional equipment) M2300 M2500

Breathing Circuits. Product training

International Journal of Science, Environment and Technology, Vol. 5, No 5, 2016,

ALLIED HEALTHCARE PRODUCTS, INC. Litholyme, GE Medisorb, Carbolime, and Amsorb Plus. Test Summary

PC7-C Flowmeter O2/N2O Sedation Unit Instruction Manual

Landmark. Veterinary Anesthesia Systems. Operator s Manual P/N

Errors in Monitoring. BWH Clinical Conference 10/06/04. Copyright 2004, James H Philip, all rights reserved.

AUTOVENT 4000 VENTILATOR

Aestiva/5. Operation Manual - Part 1. Software Revision 4.X System Controls, Operation, Checkout

Apollo Safety Features

INTEGRUSPSV ANAESTHESIA WORKSTATION USER MANUAL

Anesthesia Solutions. Prima SP and Prima SP2 Anesthesia Systems. The Future of Anesthesia. Partnership for Life

Your customized anesthesia workstation DRÄGER FABIUS GS PREMIUM. Dräger. Technology for Life

State-of-the-art anesthesia technology

SERVICE KITS AND CALIBRATION NOTES

The centerpiece of a comprehensive anaesthesia workstation

Kinetics of Inhaled Anesthetic Agents

Prima SP2/3 Anaesthetic Machine Range Service Manual Partnership for Life

Testing anaesthetic machines, ventilators and related equipment

Carestation 650. Physical Specifications Product Description Carestation 620 A1 ANESTESI CARESTATION 650

Service Manual. Anesthesia System ANESTHESIA S ANESTHESIA SYSTEM

PORTER INSTRUMENT COMPANY, INC.

Understanding Rebreathing Kinetics

M5400 Operators Manual

The Anesthesia Gas Machine

Historically, rebreathing anesthesia systems

SIGNET 615 ANAESTHESIA WORKSTATION USER MANUAL

VETROSON. OXY-GEN SYSTEMS (Oxygen Generating Systems) Question & Answer Brochure

Medical Instruments in the Developing World

NARKOVET ANAESTHETIC UNIT

Your patients, our primary focus. Siesta i Whispa anesthesia machine

LISTADO DE CIRCUITOS DE PACIENTE

Fabius plus. The plus that makes all the difference. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Fabius plus. The plus that makes all the difference. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Innovating with you Shaping exceptional care

The SAV04 Small Animal Ventilator. Contents Page

STANDARD OPERATING PROCEDURES DIVISION OF COMPARATIVE MEDICINE UNIVERSITY OF SOUTH FLORIDA

Nitrous oxide Quiz 2017 Answers

Operation and Maintenance of the EPV200 Portable Ventilator

patient education program 4156 South 52 nd Street, Omaha, NE ChildrensOmaha.org/HomeHealthcare

D The plus that gives you more DRÄGER FABIUS PLUS

The anaesthesia workstation focused on you

The anaesthesia workstation focused on you

(Delivery System) Pocket Guide. Series 3 software

IV-ANE. User s Manual. Anesthesia equipment for test animals. Petition

VAPOMATIC ANESTHETIC VAPORIZER

COMPANY PROFILE. Engler manufactures the Sonus V ultrasonic dental unit for the human market

Reclaim Basic Set Up

PERSEO EVOLUTION. workstation for gaseous anaesthesia. for adults, children and newborns. Code: OM 403 / 3 gas module 3 rotameter

A200SP Circle Absorber Service Manual

Your patients, our primary focus

MACS Mask CPAP System

ANESTHESIA VAPORIZER SERVICE RECOMMENDATIONS

Welcome to the Specialized Medical Services Respiratory training webinar series!

3:1 High Ratio Oil Pump W. Extn. Kit

APUS Anesthesia Machines

Overview. Front Panel: Keypad and Display

OXY-VIVA 3 RESUSCITATOR OPERATING INSTRUCTIONS

Technical Data and Specifications

Parker Hannifin Corporation Porter Instrument Division 245 Township Line Road Hatfield, PA USA Tel: Ref Rev.

User Guide and Operating Manual

2011 Equipment Catalog

Transcription:

Anesthesia Machine Intro Brigham and Women s Hospital New Residents July 9, 2010 Copyright 2000-2010, James H Philip, all rights reserved

ADS1 Ready JHP

Anesthesia Machine Intro James H. Philip, MEE, MD, CCE Anesthesiologist, Director of Bioengineering Brigham and Women s Hospital Associate Professor of Anaesthesia Harvard Medical School

Anesthetist touch observe (senses) Patient Clinical Care Interactions observe (eyes, ears) touch Monitoring Inhalant Drugs IV Drugs, Fluids Other Work-station ADS, monitors, PIMS requests Care Info (lab data, image..) OR Hospital World

Anesthetist touch observe (senses) Patient Clincal Care Interactions observe (eyes ears) touch Monitoring Inhalant Drugs IV Drugs, Fluids Other Work-station ADS, monitors, PIMS requests Care Info (lab data, image..) OR Hospital World Anesthesia Delivery System

Workstation - Patient Interactions Breathing Circulation Drug delivery for anesthetization

Workstation - Patient Interactions Breathing - safe gases Circulation Drug delivery for anesthetization vapors, gases, IV Intravenous Liquid Delivery Monitoring Recording

ADS - Patient Interactions Breathing - safe gases Drug delivery for anesthetization vapors, gases

Anesthesia Machine Evolution

1846 Morton Ether Inhaler

Inhaler had limitations

1846 version

This 1850 version worked horizontal with no hands required

Open Circuit Inhaler Open Circuit = Non-rebreathing Patient breathes in the ether vapor, breathes ether out (and it is discarded) Breathes in new ether vapor Breathes it out again (discarded)

Manual Resuscitator Open Circuit = non-rebreathing Circuit = what you set is what you get What you put into the circuit is what the patient gets Give sufficient 100% oxygen flow to the reservoir bag (not to empty) Reservoir bag gives 100% oxygen to the breathing bag Breathing circuit The Tidal Volume and Minute Ventilation is determined by the size and frequency of the squeeze of your hand and a perfect seal.

Manual Resuscitator One-way valves make sure gas flows to the patient Breathing circuit A special valve allows exhaled gas to be removed

Bag Reservoir Hose Reservoir Manual Resuscitators

Bag Reservoir A bag reservoir lets you see it provides 100% oxygen to the breathing bag by never emptying and never entraining room air

Partial Rebreathing Circuits are used in Anesthesia Don t throw all the exhaled gas It contains expensive anesthetic vapors Reuse as much as possible somehow (learn more later) Remove (Absorb) CO 2 and Rebreathe the anesthetic Partial rebreathing = semi-closed circuit All ADSs use them

1890 added a Breathing Circuit

1925 Draeger 1927 Forreger added CO 2 absorbsion

1950 added a work surface

Then, Drawers, Temperaturecompensated vaporizers, Circuit, Absorber, Common gas outlet

1990 Integrated Monitors and Data Recording

Datex- Ohmeda Central Display (CD) ADS

2000 Better ventilation for difficult patients FGF-independent ventilation Corrects for circuit leaks More sensitive to water vapor Monitors not integrated

2000 GE Aestiva (BWH L&D and MOR HeliOx for ENT Surgery)

2000 Draeger Fabius (BWH many ORs)

2005-2010 state-of-the-art GE Aisys MOR - many rooms Draeger Apollo GS MOR - 6 rooms

Basics of the Anesthesia Delivery System

Anesthesia Delivery System - ADS Anesthesia Machine Breathing Circuit Ventilator

Anesthesia Machine delivers gases and vapors into a breathing circuit 2001 Provides continuous flow of - Oxygen for Life Air to safely lower F I O 2 Nitrous Oxide for partial anesthesia Agent vapor for complete or partial anesthesia

(Continuous Flow) Anesthesia Machine N 2 O Air O 2 L/m 9 8 7 6 5 4 3 2 1 0 L/m 9 8 7 6 5 4 3 2 1 0 L/m 9 8 7 6 5 4 3 2 1 0 ml/m 900 600 400 300 200 100 50 1 2 3.. Isoflurane Sevoflurane Desflurane Vaporizer Common Outlet FGF (Fresh Gas Flow)

Flow Tubes

Oxygen and Gas Delivery Mechanical Physical knobs Rotameters, GE Aestiva, Aespire

Oxygen and Gas Delivery Mechanical Physical knobs Rotameters, Digital meters Draeger Fabius Draeger Fabius Draeger Apollo Draeger Apollo

Oxygen and Gas Delivery Mechanical Physical knobs Rotameters, Digital meters Draeger Fabius Draeger Fabius Draeger Apollo Draeger Apollo

Electronic Virtual knobs Digital meters GE Avance, Aisys Oxygen and Gas Delivery GE Avance, Aisys % Oxygen in FGF NOT inspired - be careful

Vaporizer Types Mechanical Penlon Signa for isoflurane, sevoflurane GE Tec 3,4,5,7 for isoflurane, sevoflurane GE Tec 6 for desflurane (electro-mechanical) Draeger Vapor 19, 2000 for all agents Direct-reading, temperature-compensated Electronic GE Aladin for all agents

Anesthesia Machine

Anesthesia Machine Schematic

Anesthesia Machine Schematic

SIMPLIFIED ANESTHESIA MACHINE SCHEMATIC DIAGRAM N 2 O SERVICE INLET 55 psi N 2 O 750 psi N 2 O FILTER FAILSAFE VALVE N 2 O N 2 O CHECK VALVE 35 psi PRESSURE REGULATOR S CALIBRATED VAPORIZERS I D 750 psi WALL NEEDLE VALVE DISS diameter index safety system CONNEC- TION O 2 2000 psi O 2 2000 psi O 2 35 psi ON/OFF SWITCH OXYGEN FLUSH VALVE [first] 50 or 250 ml/min O 2 [Anesthetizing gases flow] Flush Flow (last) Fresh Gas Flow (FGF) COMMON OUTLET FRESH GAS HOSE O 2 SERVICE INLET 55psi

Patient Breathing Circuit Allows cyclic flow To and from the patient (AKA Breathing)

Circle absorption anesthetic breathing circuit

flipped

The Circle-Absorber System Exhaust Expired Gas Flows CO 2 Absorbant Rebreathed Sampled 200 ml/min Fresh Inspired

The Circle-Absorber System Exhaust Expired Gas Flows Rebreathed CO 2 200 ml/min Absorbant Fresh Inspired

The Circle-Absorber System Exhaust Expired Gas Flows Rebreathed CO 2 Absorbant Fresh Inspired

The Circle-Absorber System Exhaust Expired Gas Flows Rebreathed CO 2 Absorbant Fresh Inspired To Patient

The Circle-Absorber System Exhaust Expired Gas Flows Rebreathed CO 2 Absorbant Fresh Inspired From Patient

The Circle-Absorber System Exhaust (APL) Expired Gas Flows Rebreathed CO 2 Absorbant Fresh Inspired

The Circle-Absorber System Exhaust (APL) Expired Gas Flows CO 2 Rebreathed Gases (O2, N2O, Agent) Absorbant Fresh Inspired

The Circle-Absorber System Exhaust Expired Gas Flows CO 2 Absorbant Rebreathed Gases No CO 2 rebreathed Fresh Inspired

The Circle-Absorber System Exhaust Expired Gas Flows No Rebreathed Gases CO 2 Absorbant No CO 2 Fresh Inspired

The Circle-Absorber System Exhaust Expired Gas Flows CO 2 Absorbant Rebreathed Gases No CO 2 Fresh Inspired

The Circle-Absorber System Exhaust Expired Gas Flows V E CO 2 Absorbant Fresh Inspired

Gas is sampled from circuit near patient for I/E measures Exhaust Expired Gas Flows CO 2 Absorbant V E Sampled 200 ml/min Fresh Inspired

Low FGF More rebreathing Inspired more dependent on Expired Inspired less dependent on Vaporizer View the Breathing Circuit The Circle-Absorber System

The Anesthesia Workspace

Draeger Apollo

GE Aisys at BWH

Workspace Setup MRSMAID Machine Room Suction Monitors Airway I V Drugs

Workspace Setup MRSMAID Machine Room Suction Monitors Airway I V Drugs

Workspace Setup MRSMAID Machine Room Suction Monitors Airway I V Drugs Suction off if: DISS hose unscrewed Wall switch off Hose disconnect from Canister Canister switch off Insert seated incorrectly Any hole open Flap valve closed because unit was shaken or canister is full Flexible hose kinked Flexible hose stepped on

Perform Machine-Assisted Tests GE Modulus 2 Plus - none GE Aestiva - Minor 12 Hour switch off and on Circuit Oxygen Sensor Cal via SmartVent GE Aisys - Major Most circuit tests are automated Bellows volume & pressure can feel the circuit and make great ventilation modes Draeger Fabius - Major Most circuit tests are automated Ventilator Piston can feel the circuit and make great ventilation modes

CALIBRATE OXYGEN MONITOR Oxygen Monitor on & sensor in air with hole plugged. Calibrate to 21%. Reconnect sensor in circuit

CHECK MACHINE FOR GAS DELIVERY Machine On Oxygen flows smoothly Disconnect oxygen hose Oxygen alarm sounds Switch ON oxygen tank. Verify P > 1000 psi and Alarm silences. Tank off with wrench Turn oxygen flow up Alarm sounds oxygen failure Connect oxygen hose to silence alarm. Turn up nitrous and observe alarm and/or control. Negative Pressure Test - later

CHECK CIRCUIT FOR INTEGRITY Attach circuit including reservoir bag Occlude Y with thumb Flush and fill bag to 30 cmh2o. Test pressure alarms NAD - Continuing pressure alarm, high pressure alarm Ohmeda - High pressure relief Open relief valve and verify that reservoir bag empties Observe scavenger bag fill and empty

CHECK FUNCTION CHECK VENTILATOR FOR FUNCTION Ventilate reservoir bag and observe no volume loss. CHECK SCAVENGER FOR FUNCTION Check that reservoir bag fills and empties. Check valves not stuck.

Thank you

End