February 5, 2014 REQUEST FOR ADDITIONAL INFORMATION FOR THE REVIEW OF THE MODEL NO PACKAGE

Similar documents
".1<1.:).-. _. Mr. Sylvain Faille FILE I-QOSS!ER I

A Rationale for Pressure Relief Device(s) Qualification Requirements (LH2)

Regulatory Concerns for Leakage Testing of Packagings with Three 0-Ring Closure Seals

v. Size shall be specified on drawings.

CB7 Bayonets Male & Female 1/4", 3/8, & 1/2 Size

COMMERCIAL ITEM DESCRIPTION TORCHES, OXYACETYLENE, HAND HELD, CUTTING AND WELDING

MSC Guidelines for Pressure Vessels

CLASS D - SENSITIVE LEAK TEST GAS AND BUBBLE METHOD. 1.1 To provide definitive requirements for PNEUMATIC pressure testing of piping systems.

Transportation Package Seal Performance in Beyond Design Basis Thermal Exposures 12472

~ goss7-- OSTI RECEIVED LEAKAGE TESTING OF PACKAGINGS WITH THREE-O-RING CLOSURE SEALS. c=t) SUMMARY INTRODUCTION

PERFORMANCE SPECIFICATION PROPELLANT, HYDROGEN

Summary of Substantive Changes between the 2004 e1 and 2017 editions of ASSE 1011, Hose Connection Vacuum Breakers

SECTION BUTTERFLY VALVES

East Building, PHH-30 U.S. Department New Jersey Avenue S.E. of Transportation Washington, D.C DOT-SP (TWENTY-THIRD REVISION)

VALVE MANUFACTURERS ASSOCIATION API 622 API 624

Procedure: Pressure equipment safety

Exhibit 4. Determination of Static Pressure Performance of the Healy Clean Air Separator (Executive Orders VR-201-N and VR-202-N)

NIOSH Task Number 18388

Proportional Relief Valves

1811G/H PITOT-STATIC TEST SET

Tank Blanketing Pressure Regulators RHPS Series

GUIDELINES FOR CONDUCTING HYDROGENATION REACTIONS

ASSE International Product (Seal) Listing Program

MSC Guidelines for Independent Fuel Tanks

FUGITIVE EMISSIONS EXPERIMENTAL MEASUREMENTS AND EQUIVALENCY

Regulated Oil and Gas Companies under National Energy Board Jurisdiction

NBIC Committee Action Block

PROCEDURES FOR REPAIRS TO ASME NV STAMPED PRESSURE RELIEF DEVICES OF NUCLEAR SAFETY RELATED PRESSURE RELIEF VALVES

Installation Operation Maintenance

TYPE 7800 SERIES 7848D/7848W UNIVERSAL VESSEL SEAL Technical Specification

Tutorial on Flange Qualification using CAEPIPE

MSC Guidelines for Sanitary & Sewage Systems

CNS In-Pool Assembly Mechanical Design for OYSTER Project

Standard Pneumatic Test Procedure Requirements for Piping Systems

TYPE 7828G/7828GD 7800 SERIES UNIVERSAL VESSEL SEAL Technical Specification

INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Model Sanitary Vent SECTION I

CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

INSTALLATION, MAINTENANCE & OPERATING INSTRUCTIONS 2-4 REDUCED PORT/ FULL PORT (5700/6700) ANSI CLASS 150/300/600/900/1500/2500 TRUNNION BALL VALVES

East Building, PHH-30 U.S. Department New Jersey Avenue S.E. of Transportation Washington, D.C EXPIRATION DATE: June 30, 2015

UIB30 and UIB30H Sealed Inverted Bucket Steam Traps for use with Pipeline Connectors

Control of Nuclear Gloveboxes and Enclosures Using the No- Moving-Part Vortex Amplifier (VXA)

HANDBOOK SAFETY DEVICES. Ed SAFETY DEVICES DS-ED 01/ ENG 1

Instrument Operating Manual

EXPIRATION DATE: (FOR RENEWAL, SEE 49 CFR ) 1. GRANTEE: Structural Composites Industries (SCI) Pomona, CA

Bourdon Tube Pressure Gauges Ultra High Purity (UHP) Series Type

Limited quantities of compressed gases.

East Building, PHH-30 U.S. Department New Jersey Avenue S.E. of Transportation Washington, D.C DOT-SP (FOURTH REVISION)

Design and Safety Document for the Vacuum Windows of the NPDGamma Liquid Hydrogen Target at SNS

Installation, Operation and Maintenance Manual for Back Pressure Regulator

[Reserved] Packagings ICC 3 1 3AA 3AL 3AX 3A480X 3AAX

Valve Inspection & Testing

VACUUM TESTING PRECAST CONCRETE MANHOLES

AWWA C504 COMPLIANT VALVES FROM 3 THRU 108

Environmental Gasket Company Ltd. 309 Hanzhongmen Ave. Nanjing, PR China. 13EGC-MPA /Hh/Mor/Scr Fishbone Gasket

ASSE International Product (Seal) Listing Program

INSTALLATION, OPERATION and MAINTENANCE MANUAL

IAPMO GUIDE CRITERIA FOR BALL VALVES IAPMO IGC PURPOSE

Propor tional Re lief Valve s

PERFORMANCE SPECIFICATION SHEET MICROPHONE ASSEMBLY, M-169A/AIC

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

LESER Deutschland Standard Functional Tightness Test (Cryo) Content

Compressed Gases Storage and Handling Safety Policy. Individual Unit Function: Safety Procedure No.: SOP-0103 Page: 1 of 6

Installation Instructions For Flat Seated Bolted Type RAH Series Disk Holders

PERFORMANCE SPECIFICATION VALVE; AIRCRAFT, PNEUMATIC, HIGH-PRESSURE CHARGING

DRAFT REGULATORY GUIDE DG-1074

Design DSA Steam-Atomized Desuperheater

PVP2006-ICPVT

Johnston Invar Coupling Johnston Invar Coupling

Horizontal Bladder Tanks

Vertical Bladder Tanks

Section 1.3: PRESSURE VESSEL COMPONENTS AND SYSTEMS AND COMPRESSED GAS CYLINDERS

THE PROCESS OF JOINT INTEGRITY

Wheel operated Residual Pressure Valves

HEALTH AND SAFETY EXECUTIVE HM NUCLEAR INSTALLATIONS INSPECTORATE

Product Test Report F.A. Lennon Drive December 2015 Solon, Ohio U.S.A. Page 1 of 7. Valve Series Description Test Pressure Test Qty.

IDEM Indiana Department of Environmental Management Office of Land Quality P.O. Box 6015 Indianapolis, IN OLQ PH: (317)

Threaded Closures Installation, Operation & Maintenance

Safe transport of radioactive materials Leakage testing on packages

HYDROSTATIC LEAK TEST PROCEDURE

Guidance on the Ionising Radiations Regulations 1999 (IRR99)

Air Eliminators and Combination Air Eliminators Strainers

CONTENTS OF THE PCSR CHAPTER 1 - INTRODUCTION AND GENERAL DESCRIPTION

Overflow valves Type OFV REFRIGERATION AND AIR CONDITIONING. Technical leaflet

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

International Civil Aviation Organization DANGEROUS GOODS PANEL (DGP) MEETING OF THE WORKING GROUP OF THE WHOLE. Montreal, 18 to 22 April 2005

KECKLEY. Installation, Operation, and Maintenance Manual. Style KGV - Knife Gate Valve

General page Straight unions page Angle unions page Tee and L-unions page Gauge connection unions page 42

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Берг АБ Тел. (495) , факс (495) Turning Ideas Into Engineered Solutions KAYDON RING & SEAL, INC.

Advisory Circular (AC)

Figure 1: Hydrostatic Pressure Forces Are Perpendicular to the Surface

Commercial Practice Test Method Internal Vapor Analysis of Hermetic Devices

Model MTB-ASME Vertical Bladder Tanks

Before using or working with the Grab n Go Heliox system, please read and understand the usage and safety instructions provided in this booklet.

Hydraulic Piston Accumulators

600 o F High Temperature Aging Cell Instruction Manual

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

Model MTB-ASME Vertical Bladder Tanks

Model MTB-ASME Horizontal Bladder Tanks

Transcription:

February 5, 2014 Mr. Patrick W. McGuire, Assistant Manager Nuclear Material Stabilization Project Savannah River Operations Office U.S. Department of Energy P.O. Box A Aiken, SC 29802 SUBJECT: REQUEST FOR ADDITIONAL INFORMATION FOR THE REVIEW OF THE MODEL NO. 9975 PACKAGE Dear Mr. McGuire: By letter dated September 30, 2013, the United States (U.S.) Department of Energy s (DOE) Savannah River Operations Office submitted an application to request a Certificate of Compliance for the Model No. 9975 package. In connection with the staff s review of your application, we need the information identified in the enclosure to this letter. We request that you provide this information by March 7, 2014. If you are unable to meet this deadline, you must notify us in writing no later than February 27, 2014, of your submittal date and the reasons for the delay. The staff will then assess the impact of the new submittal date and notify you of a revised schedule. Please reference Docket No. 71-9975 and TAC No. L24798 in future correspondence related to this request. The staff is available to meet with you to discuss your proposed responses. If you have any questions regarding this matter, I may be contacted at (301) 287-0759. Sincerely, /RA/ Pierre Saverot, Project Manager Licensing Branch Division of Spent Fuel Storage and Transportation Office of Nuclear Material Safety and Safeguards Docket No. 71-9975 TAC No. L24798 Enclosure: Request for Additional Information cc: J. Shuler, Department of Energy, c/o L. F. Gelder H. Gunter, Department of Energy, Savannah River Operations Office J. Bellamy, Savannah River National Laboratory

Mr. Patrick W. McGuire, Assistant Manager Nuclear Material Stabilization Project Savannah River Operations Office U.S. Department of Energy P.O. Box A Aiken, SC 29802 SUBJECT: REQUEST FOR ADDITIONAL INFORMATION FOR THE REVIEW OF THE MODEL NO. 9975 PACKAGE Dear Mr. McGuire: By letter dated September 30, 2013, the United States (U.S.) Department of Energy s (DOE) Savannah River Operations Office submitted an application to request a Certificate of Compliance for the Model No. 9975 package. In connection with the staff s review of your application, we need the information identified in the enclosure to this letter. We request that you provide this information by March 7, 2014. If you are unable to meet this deadline, you must notify us in writing no later than February 27, 2014, of your submittal date and the reasons for the delay. The staff will then assess the impact of the new submittal date and notify you of a revised schedule. Please reference Docket No. 71-9975 and TAC No. L24798 in future correspondence related to this request. The staff is available to meet with you to discuss your proposed responses. If you have any questions regarding this matter, I may be contacted at (301) 287-0759. Sincerely, /RA/ Pierre Saverot, Project Manager Licensing Branch Division of Spent Fuel Storage and Transportation Office of Nuclear Material Safety and Safeguards Docket No. 71-9975 TAC No. L24798 Enclosure: Request for Additional Information cc: J. Shuler, Department of Energy, c/o L. F. Gelder H. Gunter, Department of Energy, Savannah River Operations Office (SROO) J. Bellamy, Savannah River National Laboratory G :\SFST\Saverot\71-9975\RAI letter.doc ADAMS Accession No. : ML14042A041 OFC: SFST E SFST E NAME: DATE: PSaverot SFST E SFST E SFST E SFST E SFST DTang DTarantino JChang JBorowski ACsontos CAraguas 01/27/2014 01/28/2014 02/03/2014 01/29/2014 01/29/2014 02/03/2014 02/03/2014 OFC: SFST E SFST E NAME: DATE: MDeBose MSampson 02/05/14 02/04/2014 SFST E SFST E SFST E SFST E SFST OFFICIAL RECORD COPY

Request for Additional Information for the Model No. 9975 Package Docket No. 71-9975 By letter dated September 30, 2013, the United States (U.S.) Department of Energy s (DOE) Savannah River Operations Office submitted an application to request a Certificate of Compliance for the Model No. 9975 package. This request for additional information (RAI) identifies information needed by the staff in connection with its review of the RAI responses and of the application. The requested information is listed by chapter number and title in the applicant s safety analysis report. The staff reviewed the application using the guidance in NUREG-1609, Standard Review Plan for Transportation Packages for Radioactive Material." Each individual RAI section describes information needed by the staff to complete its review of the application and to determine whether the applicant has demonstrated compliance with the regulatory requirements. Chapter 2 Structural and Materials Evaluation 2-1 Clarify Table 2-19 of the application Maximum Containment Vessel Primary and Secondary Stress combinations. Identify the acronyms or abbreviations, P pr, Q p, F pr, Q total, and F total, used in presenting stress categories for reporting containment vessel stress analysis results. Demonstrate, as an example, the calculations of the governing stress margins for Sections AA, BB, CC, and DD of the primary containment body using the stress values listed in the table. The stress intensity summary table should clearly be delineated to facilitate staff s review of the basis and results for stress analysis for the containment vessels. This information is required by the staff to determine compliance with 10 CFR 71.41(a). 2-2 Discuss the use of the lubricant as it may relate to possible detrimental effects to the fit, function, or operation of the O-rings and nut thread surfaces of the package. Define and explain the meaning of or equivalent. The operating procedures specify that, if cleaned as part of step 20, the O-ring surfaces shall be lightly re-lubricated with a silicone high vacuum grease, and the Cone-Seal Nut thread surfaces be lubricated, if needed, with a small amount of KRYTOX fluorinated grease, or equivalent. This information is required by the staff to determine compliance with 10 CFR 71.39 and 71.43(d). 2-3 Correct, as appropriate, the typo and editorial errors as follows:

- 2 - a. Page 2-22. Change ASME Code Section NB-3226 to read ASME Code Subsection NB-3226. b. Page 2-34. Change Appendix 3.4 to read Appendix 2.4. c. Page 3 of 6, Appendix 2.5. Change The 9966 and 9973 to read 9967 and 9973, in the second last line from the bottom of the page. This information is required by the staff to determine compliance with 10 CFR 71.31. Chapter 3 Thermal Evaluation 3-1 Provide additional justification for the statement made in Section 3.4.1.1 of the application: The differences in 3013 inner and convenience cans from different DOE sites are small and will not impact the overall accuracy of the results presented in this application. The applicant should explain what the differences are in the 3013 inner and convenience cans and why these differences will not impact the overall accuracy of the thermal performance presented in this application. This information is required by the staff to determine compliance with 10 CFR 71.33, 71.35, 71.71, and 71.73. 3-2 Use the NCT steady-state temperatures (with insolation) as the initial temperatures of the package for the HAC thermal analysis. As stated in Section 3.1 and Appendix 3.22 of the application, the HAC temperatures are influenced by the initial temperatures of the package that are set for NCT with insolation or without insolation. Based on Tables 9 and 10 of Appendix 3.22, the NCT component temperatures can be increased up to 50~60 F from without-insolation to with-insolation. Per NUREG-1609 and 10 CFR Part 71, the initial steady-state temperature distribution used in the HAC thermal evaluation should be consistent with the thermal evaluation under NCT, therefore the temperature distribution from the NCT with insolation should be used as the initial conditions of the HAC thermal analysis. Therefore, the applicant should perform the thermal analysis with the NCT steady state temperatures (resulting from the case with insolation) as the initial conditions of the HAC thermal analysis. This information is required by the staff to determine compliance with 10 CFR 71.71 and 71.73. 3-3 Provide references to clarify the charring temperature of the fiberboard (Celotex) and explain how the thermal conductivity varies with the temperature. The applicant used the non-char fiberboard thermal properties throughout the entire fiberboard during the 30-minute fire and the char fiberboard thermal properties on the first 1.4-inch regions from the drum wall both radially inward from the drum side and axially inward from the top and bottom during the post-fire cooldown. The applicant listed the thermal properties of fiberboard in SAR Table 3.6 (including char and non-char fiberboard thermal conductivities) without providing references regarding the fiberboard thermal properties.

- 3 - The applicant should provide the references to identify the temperature that charring of the fiberboard occurs and clarify how the char fiberboard thermal conductivity varies with the temperature from 140 o F to 500 o F (Table below). This is needed for staff s justification of the thermal conductivity variation of the Celotex fiberboard. Temperature 100 o F 140 o F 200 o F 300 o F 500 o F Thermal Conductivity (Btu/hr-ft- F) 0.07 0.07 1.0 0.30 0.07 This information is required by staff to determine compliance with 10 CFR 71.73. 3-4 Clarify whether administrative controls are also required when diluting the 3013 container with helium. The applicant described in SAR Section 3.4.4.3 that the local atmosphere within the 3013 container should be diluted to 5% (or less than 5%) oxygen by helium or nitrogen cover gas, and then stated in SAR Section 3.4.6 that detonation is prevented by administrative controls that require dilution of the material-handling containers by nitrogen (without mentioning the helium). The applicant should clarify whether the administrative controls are required when using helium as a dilution cover gas. This information is needed to assure the administrative control is appropriately applied to prevent detonation. This information is required by the staff to determine compliance with 10 CFR 71.43(d). Chapter 4 Containment Evaluation 4-1 Clarify the extent of the PCV and SCV containment boundaries and confirm the effectiveness of the leak-test port plug, gland nut, and cone-seal plug to resist leakage. a) SAR page 4-1 indicates that the gland nut is not part of the containment boundary. However, it would appear from Figure 4-2 that the leak-test port plug, cone-seal plug, and gland nut provide containment in the region around the vertical leak-test port through-hole. b) Page 4-1 and 4-3 indicate that the PCV and SCV leak-test port plug and gland nut are used to contain content. It appears from SAR Figure 4-2 that, when installed, the lower O-ring prevents the PCV (and SCV) content from coming in contact with the leak-test port plug. However, page 8-3 indicates the lower O-ring is not tested during fabrication, maintenance, and periodic leak testing. Explain whether the leak-test port plug and mating threads of the leak-test port gland nut and cone-seal plug meet the 1E-7 ref cm 3 /sec leaktight criterion without the presence of the lower O-ring. If so, confirm that the cone-seal plug, and leak-test port plug and gland nut are listed as Important to Safety. If not, explain what measures are taken to ensure that the lower O-rings are installed as part of the containment boundary? This information is required by the staff to determine compliance with 10 CFR 71.33,

- 4-71.51, and 71.105. 4-2 Clarify the classification of the PCV and SCV, including their O-rings, plugs, and nuts. The PCV and SCV, including their O-rings, plugs, and nuts, are listed as part of the containment boundary, and therefore, should be classified as Important to Safety per NUREG/CR-6407. This information is required by the staff to determine compliance with 10 CFR 71.33 and 71.105. 4-3 Provide details of the PCV and SCV O-rings and groove/gland, including dimensions and compression set. a) Although details of the O-ring grooves and surface finish are provided in drawing R- R4-G-00102, details of the O-rings, such as dimensions, are not provided in the SAR. b) Drawing R-R4-G-00102 indicates a gland dimension of 0.086 inch whereas page 69 of 234 of Appendix 2.2 indicates a 0.0995 inch mean depth of the O-ring gland. Explain the differences in the two values and confirm that the O-ring glands are appropriate for the O-ring dimensions. c) Provide calculations that confirm the torque values denoted on SAR pages 7-7 and 7-8 are sufficient to provide the required compression of the O-rings. This information is required by the staff to determine compliance with 10 CFR 71.33 and 71.43. 4-4 Confirm that the PCV and SCV O-ring seal arrangement is equally effective in resisting internal and external pressures. SAR page 2-25 indicates that the O-rings can withstand internal pressures of 575 psig. In addition, page 2-47 discusses analyses that show the containment vessels can structurally withstand the 290 psi external pressure of 10 CFR 71.61. However, a conclusion confirming that the O-ring arrangement can withstand the 290 psi external pressure was not provided. This information is required by the staff to determine compliance with 10 CFR 71.61. 4-5 Clarify whether the concentration of hydrogen within the package is below 5% (by volume) during the expected shipping period, as discussed on page 3-8 and page 4-6 of NUREG-1609. Analyses in SAR Section 3 of Appendix 3.6 indicate relatively high hydrogen concentrations due to radiolysis of water vapor within the seal welded 3013 container. However, the calculations assume a 50 year storage period. Calculations that show the hydrogen concentrations during the expected shipping period should be provided. This information is required by the staff to determine compliance with 10 CFR 71.43.

- 5-4-6 Confirm the appropriateness of leakage test procedures and leakage test personnel qualifications. Certain leak testing details were not found in Chapter 7 and Chapter 8. Confirm that appropriate detailed leakage test procedures are provided in lower tier documents and that leakage test personnel qualifications (i.e., ASNT certified Level III for writing procedures, etc.) are established. This information is required by the staff to determine compliance with 10 CFR 71.105, 71.123, and 71.135. 4-7 Provide details of the pre-shipment leakage test, including the type of test, so that a review can be performed. a) SAR page 4-5 states the inner O-ring forms a test volume to perform the preshipment leak test but details are not provided. The type of test (envelope, pressure rise, etc.) for the PCV and SCV should be discussed. b) SAR page 7-6 states that the PCV is diluted to at least 75% CO2 for seal testing. However, leakage test details are not provided and, therefore, it is uncertain whether the leakage acceptance criteria varies with the dilution amount. If so, the acceptance criteria should reflect the dilution amount. This information is required by the staff to determine compliance with 10 CFR 71.87. 4-8 Provide the following containment-related documents that were not included in the SAR: Reference 5 from SAR page 8-4 Reference 7 from SAR page 4-11. This information is required by the staff to determine compliance with 10 CFR 71.33 and 71.87.