Capacities Valve Station, type ICF 15, 20, 25

Similar documents
Selection of ICF made easy Save even more time with ICF

Valve station ICF 15, ICF 20, ICF 25, ICF 50 and ICF 65

2-step solenoid valve Type ICLX

Overflow valves Type OFV REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Instructions. Control Solution ICF 20-4, ICF 25-4, ICF ICF 40-4, ICF 20-6, ICF 25-6, ICF 32-6, ICF 40-6, Direction and position.

2-step solenoid valve Type ICLX

Pressure regulating valves Types OFV, OFV-SS

Instructions. Control Solution ICF 20-4, ICF 25-4, ICF ICF 40-4, ICF 20-6, ICF 25-6, ICF 32-6, ICF 40-6, Direction and Position.

Float valves Types SV 4, SV 5 and SV 6

Dual position solenoid valve Type ICSH 25-80

Solenoid Valves, one - or two step, on/off ICLX

36% higher capacity than market alternatives. New ICF 50-4 and ICF 65-3: A great valve family just got greater.

Overflow valves Type OFV Type OFV-SS REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Valve Station ICF 15, 20 and 25

80% Less installation time with just two welds for fast and efficient installation.

Float valves Types SV 1 and SV 3

80% Less installation time with just two welds for fast and efficient installation.

Solenoid valve type EVR for Hydrocarbons

Gas powered stop valves, type GPLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Solenoid valves, two-step on/off Type PMLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Liquid level regulating valves Types PMFL / PMFH and SV

Modulating liquid level regulators, direct-controlled, type SV 1 and 3 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Crankcase pressure regulator, type KVL REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Pilot valves for pilot operated servo valves

MAKING MODERN LIVING POSSIBLE. Pilot operated internal safety valves type POV REFRIGERATION AND AIR CONDITIONING DIVISION.

Modulating liquid level regulators, servo-controlled PMFL / PMFH and SV

Hand-operated regulating valves in stainless steel Types REG-SA SS and REG-SB SS

Hand operated regulating valves Types REG-SA and REG-SB

Shut-off Liquid level and regulating valves for for Industrial Refrigeration

Evaporating Pressure Regulating Valve Type KVQ REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Electric expansion valves Types AKV 10, AKV 15 and AKV 20

Industrial Refrigeration Control Valves. Catalog C12-PVS Parker Valve Station (PVS) Sizing Guide

Regulating valves REG-SA and REG-SB

Electric regulating valves Type CCMT 2 - CCMT 8 / CCMT 16 - CCMT 42

Safety relief valves SFV 20-25

Capacity regulator (hot gas bypass), type TUH/TCHE/TRHE REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Capacity regulator (hot gas bypass)

D A T A S H E E T. Technical Data. Maximum Working Gauge Pressure (bar) Capillary Tube Length (m) 1.5 (5Ft) Burst Gauge Pressure (bar) 234.

Regulating valves Type REG 6-65 Type REG-SS REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Safety relief valves Type SFV 20-25

Safety relief valves, type BSV 8 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Water valve Type WVO. Data sheet MAKING MODERN LIVING POSSIBLE

AE R8 December 2004 Reformatted November Copelametic Two-Stage Compressors Application and Service Instructions

Condensing pressure regulator, type KVR Differential pressure valve, type NRD

Technology issues regarding Blends of Refrigerants Buffalo Research Laboratory

Evaporator pressure regulator Type KVP

Safety relief valves Type BSV-8

Safety relief valves, type SFA 15

Shut-off valve Type QDV

3-way control valves VK 3

Safety relief valves Type SFA 15 and SFA 15-50

Safety relief valves, type SFA 15 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Evaporator pressure regulator Type KVP

2 - way valve (NO) for steam, pressure relieved (PN 25) VGS - external thread

for for Industrial Refrigeration

Seated valve for steam (PN 25)

2 - way valve for steam, pressure relieved (PN 25) VGS - external thread

Seated valve for steam (PN 25) VFS 2 2-way valve, flange

SINGLE VALVE WITH LOW-FLOW BYPASS

Sales Office: Danfoss Expansion Valves. T*2 Range Order valve and orifice separately Range N -40 C to +10 C Without MOP

Thermostatic Expansion

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

Condensing pressure regulator, type KVR Receiver pressure regulator, type NRD

Modulating refrigerant valves with magnetic actuator, PS45 Hermetically sealed, for safety refrigerants

MSC Guidelines for Refrigeration Machinery

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

Pressure reduction controller (PN 16, 25, 40)

Reliable System Performance PM valves

Quick closing oil drain valve, type QDV 15 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Semi-Hermetic compact screw compressors

CHECK VALVES APPLICATIONS

Refrigeration and Air Conditioning Technical leaflet

Technical leaflet. Pressure and Temperature Regulators. January 1999 RC.4X.B1.22. Danfoss A/S

Guida parametri EVD 200. Manuale d'uso User manual

CROT-6 CROT-10 CRO-4. for Compressor Overload Protection

Joint industry project on foam

Using P-T Analysis As A Service Tool

Troubleshooting Guide. Pg. 1

R-410A 50% R-32 50% R-125.

Technical Instructions Document No. CA2N4721E-P25 Rev. 1, February, Modulating Control Valve for Hot Gas Control.

Radiator thermostats type RA2000, valve bodies type RA-FN (series D) and RA-G

Pressure Regulators. Aperflux 101

Shut-off ball valve Type GBC

TROUBLESHOOTING GUIDELINES

Radiator thermostats type RA2000, valve bodies type RA-FN (series D) and RA-G

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance

POP Safety Valve. POP Safety Valve INTRODUCTION DEFINITIONS

Pressure Regulators. Aperflux 851

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

Differential pressure switch / Lube oil protection control MP 54 and MP 55

PSD 250 Minimum Lubrication System. For lubricants in the 1000 mm²/sec viscosity range

Integral type Differential pressure flowmeter VNT Series

SELECTION CRITERIA FOR SAFETY VALVE

Vacuum. Dry Turbo Pumping Stations. Roughing Pumps for 1 K Helium Pots and Lambda Refrigerators. Hermetically Sealed Pumps for He3 Recirculation

DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITIES

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

The Discussion of this exercise covers the following points: Pumps Basic operation of a liquid pump Types of liquid pumps The centrifugal pump.

Liquid level glasses, type LLG REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Practical Guide. By Steven T. Taylor, P.E., Member ASHRAE

Transcription:

Data sheet Capacities Valve Station, type ICF 15, 20, 25 Based on advanced technology the ICF valve station incorporates several functions in one housing, which can replace a series of conventional mechanical, electro-mechanical and electronically operated valves. This valve station not only provides a number of advantages in the design phase of a refrigeration plant but also in the installation, service and maintenance. The ICF valve stations are designed for low and high pressure refrigerants and can be used in pumped liquid lines, liquid injection lines and hot gas lines. Supplied as a complete assembly, it is fully tested at high pressure and its functions are tested under factory controlled conditions. One code number equals one application solution. Features Designed for industrial refrigeration applications for a maximum working pressure of 52 bar/754 psig. Applicable to CFC, non flammable FC, R717 (Ammonia) and R744 (CO 2). The use of ICF valve stations with flammable hydrocarbons is not recommended. Direct weld connections (No leaks through flanges) Connection types include butt weld and socket weld. Low temperature steel housing. Low weight and compact design. V-port regulating cones on the control modules ensure optimum regulating accuracy particularly at part load. Modular Concept Each housing is available with several different connection types and sizes. Valve service is performed by replacing the function module. Side ports for the connection of pressure gauges, transmitters, sight glasses, service valve etc. ICF valve station Nominal bore DN 25 (1 in.) DN 32-40 (1 ¼ - 1 ½ ) Classified for Fluid group I Category Article 3, paragraph 3 II Danfoss DCS (MWA) 2017.01 DKRCI.PD.FT1.B2.22 52011732 1

ICF 20 and 25 Liquid injection to separator (Expansion) Application 5 ICF with motorized valve ICM is fundamental to maintain stable liquid level in surge drums and separators. For this application the ICF (20-25)-6-5 is recommended. The flexibility of the ICF enables safe operation and efficient operation. This requires slightly subcooled or fully saturated liquid. The sight glass provided will help operator determine whether liquid only is flowing through the ICF. ICF 20-6-5 For fail safe operation this type of ICF is equipped with a ICFE solenoid valve in front of the ICM motor operated valve. Configuration ICFS 20 ICF 20-6-5 ICF 25-6-5 Motor-exp. ICFM 20 M ICFE 25 Motor-exp. ICFM 25 M M5 M5 M6 M6 ICFF 20 ICFO 20 Man. opening ICFS 20 ICFF 25 ICFB 25 Blank A simple combination of solenoid valves and motorized valves provide a wide range of capacities for direct expansion Recommended max. capacities ICF 20-6 and ICF 25-6; application no. 5 (Liquid injection) R717 ICF 20-6 / ICF 25-6 ICF 20-6-5MA33 ICF 20-6-5MA ICF 20-6-5MB66 ICF 20-6-5MB ICF 25-6-5MA33 - Module M5 - Expansion Module Max. evaporating capacity @ 75% open expansion K v (C v) value (complete valve) ICM 20A33 71 0.2 20 0.23 205 0.6 ICM 20A 58 0.7 ICM 20B66 565 1.4 160 1.6 730 2.0 ICM 20B Maximum recommendable capacity. Pipe velocity (1 m/s) used as dimensioning factor. Stated capacity is obtained with a valve opening 75% TE = 20 to 30 C ( 4 to 22 F), TC = +30 C (86 F) 207 2.3 ICFE 25 ICM 25A33 980 2.2 278 2.5 Note: For larger capacities use larger individual weld-in components such as SVA, FIA, ICS or ICM. Danfoss DCS (MWA) 2017.01 DKRCI.PD.FT1.B2.22 52011732 2

ICF 20 and 25 ot gas defrost Application 9 The ICF 20-4-9 and ICF 25-4-9 are designed to provide the necessary functions for hot gas defrost on evaporators. ICF 20-4-9 Configuration ICF 20-4-9 ICF 25-4-9 ICFS 20 / ICFE 25 ICFF 20 ICFS 20 ICFF 25 The maximum flow is typical for most evaporator applications. Evaporator type, frost thickness in fins and pipes as well as required defrost time may change the recommended model. Recommended max. capacities ICF 20-4 and ICF 25-4; application no. 9 (ot gas) R717 ICF 20-4 / ICF 25-4 ICF 20-4-9 ICF 20-4-9 ICF 25-4-9 solenoid module ICFE 25 Max. defrost massflow @ Dp = 1 bar (15 psi) Equivalent evaporating capacity K v (C v) value (complete valve) 148 44.5 3.3 [] 5.4 12.6 3.8 210 63.1 4.2 [] 7.7 17.9 4.9 The stated evaporating capacity is based on the following conditions: TE = 30 C ( 22 F), TC = +30 C (86 F) Defrost conditions: (defrost temperature +10 C (50 F) and inlet temperature +40 C (104 F)) 490 147 9.7 [] 18.0 41.7 11.3 Note: Rule of thumb state that Q defrost 2 x Q evaporating. For larger capacities use larger individual weld-in components such as SVA, FIA, ICS or ICM. Danfoss DCS (MWA) 2017.01 DKRCI.PD.FT1.B2.22 52011732 3

ICF 20 and 25 Liquid feed lines Applications 2 & 3 The ICF 20-6-2(3) and ICF 25-6-2(3) are designed for a typical pumped liquid line in a flooded evaporator system. ICF 20-6-2 Configuration ICFS 20 ICF 20-6-2 ICF 25-6-3 Man. regulating ICFR 20 Man. regulating ICFE 25 ICFR 25 M5 M5 M6 M6 ICFF 20 ICFO 20 Man. opening ICFN 20 /Check ICFF 25 ICFC 25 Check The ICF is available with different solenoid and expansion module with different capacities. The below ICF configurations shows the appropriate combination of solenoids and expansion capacity for the given conditions. Recommended max. capacities ICF 20-6 and ICF 25-6; application no. 2 and 3 (Liquid feed) @ 70% open reg. module (see flow curves) R717 ICF 20-6 / ICF 25-6 ICF 20-6-2RA ICF 20-6-2RB ICF 25-6-3RA ICF 25-6-3RB - Module M5 - Manual reg. module Max. line massflow @ 70% open reg. module* Equivalent evaporating capacity @ N circ = 3:1 K v (C v) value (complete valve) 1070 135 2.1 ICFR 20A [] 39 38 2.4 1620 205 2.6 ICFR 20B [] 59 58 3.0 3150 395 5.3 ICFE 25 ICFR 25A [] 116 112 6.1 Maximum recommendable capacity. Pipe velocity (1 m/s) used as dimensioning factor. Stated equivalent capacity is calculated for n circ = 3:1, valve opening 70% TE = 30 C ( 22 F), TC = +30 C (86 F) * See pressure drop versus massflow and opening degree in below curves. 5200 650 7.2 ICFE 25 ICFR 25B [] 191 185 8.4 Note: For larger capacities use larger individual weld-in components such as SVA, FIA, ICS or ICM. Danfoss DCS (MWA) 2017.01 DKRCI.PD.FT1.B2.22 52011732 4

ICF 20 and 25 (Continued) 2.0 Practical Rule - Finding massflow: Multiply Capacity in TR by: 0.343 x recir rate Multiply capacity in kw by 2.65xrecic rate Example: 50kW ; recirc rate 4:1: 530kg/h Flow capacity: ICF 20-6-2RA (including ICFR 20A - A cone) R717 pump circulating system Pumped liquid line 30 27 Pressure drop p [bar] 1.5 1.0 0.5 Nominal ( p=1 bar / 15 PSI) 24 21 18 15 12 9 6 Pressure drop p [psi] 3 0.0 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 Line massflow 0 5 10 15 20 25 30 35 40 Line massflow [lbm/min] 1 m/s [3.3 f/s] @ DN 20 [3/4] 2.0 Flow capacity: ICF 20-6-2RB (including and ICFR 20B - B cone) R717 pump circulating system Pumped liquid line 30 27 Pressure drop p [bar] 1.5 1.0 0.5 Nominal ( p=1 bar / 15 PSI) 24 21 18 15 12 9 6 Pressure drop p [psi] 3 0.0 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 Line massflow 0 5 10 15 20 25 30 35 40 45 50 55 60 65 Opening scale ICFR 20 1 m/s [3.3 f/s] @ DN 20 [3/4 ] 1 m/s [3.3 f/s] @ DN 25 [1 ] Line massflow [lbm/min] 0 10 20 30 40 50 60 70 80 90 100 Opening degree [%] 0 1 2 3 4 Opening [Spindle turns] Note: The stated pressure drop shown is for the whole ICF. Danfoss DCS (MWA) 2017.01 DKRCI.PD.FT1.B2.22 52011732 5

ICF 20 and 25 (Continued) 2.0 Flow capacity: ICF 25-6-3RA (including ICFR 25A - A cone) R717 pump circulating system Pumped liquid line 30 27 Pressure drop p [bar] 1.5 1.0 0.5 Nominal ( p=1 bar / 15 PSI) 24 21 18 15 12 9 6 Pressure drop p [psi] 3 0.0 0 500 1000 1500 2000 2500 3000 3500 Line massflow 0 10 20 30 40 50 60 70 80 90 100 110 120 Line massflow [lbm/min] 1 m/s [3.3 f/s] @ DN 25 [1 ] 1 m/s [3.3 f/s] @ DN 32 [1 1/4 ] 2.0 Flow capacity: ICF 25-6-3RB (including ICFR 25B - B cone) R717 pump circulating system Pumped liquid line 30 27 Pressure drop p [bar] 1.5 1.0 0.5 Nominal ( p=1 bar / 15 PSI) 24 21 18 15 12 9 6 Pressure drop p [psi] 3 0.0 0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 Line massflow 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 1 m/s [3.3 f/s] @ DN 25 [1 ] Line massflow [lbm/min] 1 m/s [3.3 f/s] @ DN 32 [1 1/4 ] Opening scale ICFR 25 1 m/s [3.3 f/s] @ DN 40 [1 1/2 ] 0 10 20 30 40 50 60 70 80 90 100 Opening degree [%] 0 1 2 3 4 5 Opening [Spindle turns] Note: The stated pressure drop shown is for the whole ICF. Danfoss DCS (MWA) 2017.01 DKRCI.PD.FT1.B2.22 52011732 6

ICF 15 Common solenoid Application 8 & 9 The ICF 15-4-8 and 15-4-9 are designed for both ot gas lines and Liquid lines in most common refrigeration plants ICF 15-4-8 / ICF 15-4-9 Configuration ICF 15-4-8 ICF 15-4-9 ICFS 15 ICFS 15 ICFF 15 ICFO 20 Man. opening ICFF 15 ICFB 20 Blank The generic configuration consists of the shown functions. The 2 different capacities shown in the tables below are achieved by 2 variants of the solenoid valve module and. Rated capacities for ICF 15 Type Rated capacity 1 ) Liquid Suction vapour ot gas K v R717 R22 R134a R404A R717 R22 R134a R404A R717 R22 R134a R404A ICF 15-4-8 252 54.3 48.9 36.9 11.6 6.1 4.5 5.3 63.0 23.7 19.6 21.0 3.2 3.7 ICF 15-4-9 350 75.5 68.0 51.3 16.1 8.5 6.3 7.4 87.6 32.9 27.2 29.2 4.2 4.9 1 ) Rated liquid and suction vapour capacity is based on evaporating temperature t e = -10 C, liquid temperature ahead of valve t l = +25 C, and pressure drop across valve p = 0.15 bar. Rated hot gas capacity is based on condensing temperature t c = +40 C, pressure drop across valve p = 0.8 bar, hot gas temperature t h = +65 C, and subcooling of refrigerant t sub = 4 K. C v gal/min Capacity Capacities are based on liquid temperature t l = +25 C ahead of valve, evaporating temperature t e = 10 C, and superheat 0 K. Liquid capacity Q l kw R 717 (N 3 ) Type Liquid capacity Q e kw at pressure drop across valve p bar 0.1 0.2 0.3 0.4 0.5 ICF 15-4-8 211 300 366 426 476 ICF 15-4-9-225 399 519 617 Capacities are based on liquid temperature t l = +25 C ahead of evaporator. The table values refer to the evaporator capacity and are given as a function of evaporating temperature t e and pressure drop p across valve. Capacities are based on dry, saturated vapour ahead of valve. During operation with superheated vapour ahead of valve, the capacities are reduced by 4% for each 10 K superheat. Suction vapour capacity Q e kw R 717 (N 3 ) Type Pressure drop across valve Suction vapour capacity Q e kw at evaporating temperature t e C p bar 40 30 20 10 0 +10 0.10 6.3 8.3 10.6 13.1 16.0 19.3 ICF 15-4-8 0.15 7.5 10.0 12.8 16.0 19.5 23.5 0.20 8.5 11.4 14.7 18.4 22.4 27.0 0.10 ICF 15-4-9 0.15 0.20 Not suitable Danfoss DCS (MWA) 2017.01 DKRCI.PD.FT1.B2.22 52011732 7

Capacity (continued) An increase in hot gas temperature t h of 10 K, based on t h = t c +25 C, reduces valve capacity approx. 2% and vice versa. A change in evaporating temperature t e changes valve capacity; see correction factor table below. ot gas capacity Q h kw Type Pressure drop across valve p bar R 717 (N 3 ) ot gas capacity Q e kw Evaporating temp.t e = 10 C. ot gas temp. t h = t c + 25 C.Subcooling t sub =4K Condensing temperature t c C +20 +30 +40 +50 +60 0.10 19.6 21.1 22.5 23.7 24.6 0.20 27.6 29.6 31.6 33.4 34.9 ICF 15-4-8 0.40 38.7 41.8 44.5 47.0 49.2 0.80 53.9 58.4 62.3 66.0 69.3 1.60 73.5 80.4 86.5 92.0 96.7 0.10 - - - - - 0.20 20.3 22.0 23.2 24.2 25.2 ICF 15-4-9 0.40 46.8 50.5 53.5 56.0 59.0 0.80 75.0 81.0 86.5 91.2 95.5 1.60 103.3 112.5 121.0 124.5 135.0 Correction factor When sizing valves, the table value must be multiplied by a correction factor depending on evaporating temperature t e. t o C 40 30 20 10 0 +10 R 717 (N 3 ) 0.89 0.91 0.96 1.0 1.06 1.10 An increase in hot gas temperature t h of 10 K reduces valve capacity approx. 2% and vice versa. ot gas capacity G h kg/h Type ICF 15-4-8 ICF 15-4-9 ot gas temperature t h C 90 Condensing temperature t k C R 717 (N 3 ) ot gas capacity G h kg/h at pressure drop across valve p bar 0.5 1 2 3 4 5 6 25.0 142.0 196.9 270.4 315.7 347.0 368.2 379.8 35.0 159.4 221.6 305.0 363.4 407.4 440.0 462.8 45.0 177.1 248.7 344.1 410.5 463.5 507.6 541.7 25.0 182.8 277.0 379.5 448.6 499.2 536.1 562.0 35.0 205.3 311.3 430.0 514.5 577.0 629.0 668.2 45.0 226.5 344.2 480.4 578.5 654.8 718.8 771.7 Danfoss DCS (MWA) 2017.01 DKRCI.PD.FT1.B2.22 52011732 8

Danfoss DCS (MWA) 2017.01 DKRCI.PD.FT1.B2.22 52011732 9

Danfoss DCS (MWA) 2017.01 DKRCI.PD.FT1.B2.22 52011732 10