Physicist's Responsibility On End-Of-Life for Brachytherapy Devices and Software

Similar documents
Market Update. Randy Tinseth Vice President, Marketing Boeing Commercial Airplanes. Copyright 2016 Boeing. All rights reserved.

Temporary Equipment Fails After 20 Years of Use Worker Gets Sandblasted

Marine Risk Assessment

Public Transport Asset Management

Managing for Liability Avoidance. (c) Lewis Bass

Business Plan Presentation

FMECA Analyses of radiological over-exposure accident to patients in brachytherapy

IMPLEMENTATION STRATEGIES

2016 American Academy of Actuaries. All rights reserved. May not be reproduced without express permission. ADDITIONAL LIABILITY ASSUMPTION OVERVIEW

Notes on Risk Analysis

18.1 Introduction Maintaining pedestrian-related Problems arising in the long term. infrastructure

BGA244 Binary Gas Analyzer

Archery Risk Management Plan Lutanda Yarramundi

Reliability engineering is the study of the causes, distribution and prediction of failure.

Deaths/injuries in motor vehicle crashes per million hours spent travelling, July 2007 June 2011 (All ages) Mode of travel

APPENDIX C. Systems Performance Report C-1

Using what we have. Sherman Eagles SoftwareCPR.

CONTROL SOLUTIONS DESIGNED TO FIT RIGHT IN. Energy Control Technologies

SOP 407: PROTOCOL DEVIATIONS AND UNANTICIPATED PROBLEMS

UNIVERSITY OF OKLAHOMA HEALTH SCIENCES CENTER. Automated External Defibrillator Policy

Water System Assessment User s Guide

Best Practice RBI Technology Process by SVT-PP SIMTECH

Employ The Risk Management Process During Mission Planning

Guidelines for Providing Access to Public Transportation Stations APPENDIX C TRANSIT STATION ACCESS PLANNING TOOL INSTRUCTIONS

DESIGN AND INSTALLATION CONSIDERATIONS FOR TSI AEROTRAK VHP-RESISTANT REMOTE PARTICLE COUNTERS

Failure Mode and Effect Analysis (FMEA) for a DMLC Tracking System

Development and Evolution of an Asset Management Organization

Mark Malone, P.E. SD DOT

US 19 Pedestrian and Bicycle Safe Access to Transit Corridor Study

Public Opinion, Traffic Performance, the Environment, and Safety After Construction of Double-Lane Roundabouts

4 Staff Selection, Appraisal and Development. To prevent harm by identifying and controlling potential hazards.

Identification and Screening of Scenarios for LOPA. Ken First Dow Chemical Company Midland, MI

Accident/Incident Reporting and Investigation Procedures

Competency Record for Sonic Cleaning

SAFETY MANAGEMENT SYSTEM

Work Health and Safety Risk Management Procedures

EMERGENCY MEDICAL SERVICES DATA IN ILLINOIS

HS329 Risk Management Procedure

Medical Instruments in the Developing World

CITY OF WEST KELOWNA COUNCIL POLICY MANUAL

Safety-critical systems: Basic definitions

Hazard and Risk Assessment Guide

Mountain Bike Risk Management Plan

RISK ASSESSMENT. White Paper.

Minnesota Ballpark Authority Board Meeting Minutes October 11, 2018

In-Roadway Warning Light Systems Overview, Evaluation, Installation and Investment Considerations

CASE STUDY ON RISK ASSESSMENTS FOR CROSS CONTAMINATION. Stephanie Wilkins, PE EMA Workshop June 2017

Hazard Identification and Control

Safety-Critical Systems

POLICY ON THE PROVISION & USE OF PERSONAL PROTECTIVE EQUIPMENT

1.1. Any ASA member who meets the following criteria will be allowed unsupervised access to ASA oxygen system

THE ST. LOUIS PREDICTIVE MAINTENANCE PROGRAM

Elements of an Effective Aquatic Risk Management Plan Linda Griffith, JD, ARM

Covered Task 007OP Training Guide Operate Valves

Transportation and Public Works Annual Motor Vehicle Collision Report

Paving for Progress Municipal Streets Seminar

Faculty/School: Faculty of Pharmacy Initial Issue Date: Oct 2016

DRAG HARROW SAFETY & OPERATING INSTRUCTIONS. Original Language. Serial No. Order No.

CBRE Seminar. 30 th March Creating Shareholder Value. Budgeting Operational Expenses Commercial

Operator Exposed to Chlorine Gas

Surf Life Saving Australia Policy

deluxe toilet safety support

Appendix 12 Parking on footways and verges

Reliability predictions in product development. Proof Engineering Co

How to Design Medical Accelerator Systems for Reliability: IBA PT System

Cycling and risk. Cycle facilities and risk management

Gas Injection Systems

Quantitative Risk Analysis (QRA)

VELUX PRODUCT GUARANTEE

SINGLE BRAID INSPECTION

British Schools Karting Championship 2017 Risk Assessment

RiskTopics. Lockout/Tagout October 2017

Safety and operating instructions

Estimating Ridership of Rural Public Demand- Response Transit

Unassisted breathing and death as competing events in critical care trials

1. SAFETY 2. PREPARATION 3. FRAME 4. TRANSMISSION 5. DRIVE 6. ROW UNIT 7. OPTIONAL EQUIPMENT

Ceiling Lift. Arm Extension OWNER S MANUAL

RISK METHODOLOGY FOR FUDS

Risk Assessment Guidance for QM in Brachytherapy. Conflicts. Learning Objectives. Example Procedure

PART Q CONTROL OF HAZARDOUS ENERGY (LOCKOUT-TAGOUT)

Manufacturers continue capacity expansion as technology orders grow

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

GUIDE TO RUNNING A BIKE SHARE. h o w t o p l a n a n d o p e r a t e a s u c c e s s f u l b i k e s h a r e p r o g r a m

VALIDATE LOPA ASSUMPTIONS WITH DATA FROM YOUR OWN PROCESS

Significant Change to Dairy Heat Treatment Equipment and Systems

PRO-ROD TM COILED ROD. Reduce Maintenance Increase Production Enhance Profit

BSR GPTC Z TR GM References and Reporting Page 1 of 8

Siting classification for Surface. Michel Leroy, Météo-France

Attachment C: Benefit-Cost Analysis Spreadsheet

Sample Preview. Sample Preview. Executive Summary. Business Overview. Business Structure. Organization. Management Profile

SAFE WORK METHOD STATEMENT WORKING IN CONFINED SPACE HSE NET NAT SWMS APAND00030

Guidance on safety during abandon ship drills and fire drills on board ships

UNIVERSITY OF TENNESSEE GRADUATE SCHOOL OF MEDICINE INSTITUTIONAL REVIEW BOARD CONTINUING REVIEW AND REAPPROVAL OF RESEARCH

POWER Quantifying Correction Curve Uncertainty Through Empirical Methods

How to Do Flight Testing for TARC. Trip Barber NAR TARC Manager

North Coast Outfitters, LTD. Model SR901RT Multi-Purpose Utility Table SAFETY ASSESSMENT REPORT (SAR)

The Chamber of Commerce for Greater Philadelphia Economic Outlook Survey Results

Policy for Evaluation of Certification Maintenance Requirements

Pavement and Asset Management from a City s Perspective Mike Rief, PE, DBIA and Andrea Azary, EIT. February 12, 2015

CAPA Plans: Solutions, not Blame

Transcription:

Physicist's Responsibility On End-Of-Life for Brachytherapy Devices and Software Wayne M. Butler, PhD. Schiffler Cancer Center and Wheeling Jesuit University Wheeling, WV U rologic Research Institute Customers who choose to continue clinical use of transfer tubes, applicators and accessories beyond the expected life assume responsibility and liability for all use. Nucletron User Notice IUN 799701-00 11 Nov 2013 1

Who is responsible? Patient safety is important to manufacturers and users Other motives may be present but so what? Manufacturer would like to sell more widgets or services User wants to minimize capital and service expenditures 2

Scenarios Manufacturer publishes guidance for end-of-life Limited time of service expected life Limited number of uses useful life Manufacturer declares end-of-life Will no longer service the device Oversimplification of the choice to replace or not 3

Are older devices more hazardous? Survey on 2,031 pieces of equipment in Norway Average age of 7.4 years Mean life span of 15 years Failure rate higher for newer equipment Operator errors higher for newer devices Older equipment less complex and easier to use If you choose not to replace You will need an inspection log Hardware intact and undamaged You will need a testing log Software functioning correctly How often have you seen device failure shortly after a Preventive Maintenance Inspection? 4

What constitutes sufficient data and analysis to avert liability? Predictors of failure Radiation damage not often visible Testing for aging effects may cause harm Elasticity, tensile strength, burst strength Adverse storage conditions Temperature, humidity, light exposure Different from manufacturer s life cycle tests Sterilization procedures take a toll 5

One transfer tube was not sterilized Is your data sufficiently granular to allow a faithful representation of the clinical reality? 6

Track applicator use Date when first placed in service Log sterilization cycles (or cleaning & disinfection) Add field to patient database to record applicator used Log number of uses for transfer tubes 7

Consider replacement informed by risk analysis Risk assessment: 1. Determine the likelihood of harm Likelihood Group Example of Probability of Harm 4 Occurs every time 3 2 High likelihood or considerable certainty, reasonable probability to occur Expected to occur from time to time, infrequent or small likelihood 1 Not expected to occur 0 Inconceivable, not possible 8

Risk assessment: 2. Determine the severity of harm Severity Level Examples of Harm 4 Directly results in death 3 2 Serious or life-threatening injury, permanent impairment Results in moderate injury, temporary impairment, or self-limiting illness 1 Results in minor or no injury Risk assessment: 3. Determine acceptability Severity Likelihood 1 2 3 4 Minor Moderate Serious Death 4 Unacceptable Unacceptable Unacceptable Unacceptable 3 Acceptable Unacceptable Unacceptable Unacceptable 2 Acceptable Further analysis needed 1 Acceptable Acceptable Unacceptable Further analysis needed Unacceptable Unacceptable 0 Acceptable Acceptable Acceptable Acceptable 9

A risk decision An HDR brachytherapy component failed during treatment. Alerts to staff prevented any harm to the patient. National tracking data show the mean time to failure of this component to be 1,000,000 uses. There are 4,000 devices in the field used once daily. Is this risk acceptable? Navigation aids for prioritized replacement 10

Public health perspective Return on investment for medical device safety should be proportional to other social investments in safety Global replacement vs. selective replacement Global replacement ensures all failed components are removed Selective replacement minimizes disruption Life cycle cost analysis Prospective system values derived from anticipated operations and maintenance costs Projected revenue Availability of new technology Medical equipment insurance programs Flexibility of on-demand service Safety of a capped budget 11

Cooperation between Physics and Bio-Med Engineering useful Prioritizing equipment for replacement Track service history Records kept by Physics or Bio-Med Engineering Ranking should include: Function, utilization and risk Equipment age and vendor support Maintenance cost Efficacy of newer technology 12

Institutional policy on replacing obsolete or expired equipment Should be based on historic use data Cost/benefit analysis Whole systems will be capital purchases Components may be billed as repair Availability of competent treatment nearby Your environment is unique 13

Statistical criteria are not individually predictive Statistics from large samples are useful for comparisons Mean or median life expectancy is useful for planning The uncertainty or deviation may be large, small, or unknown Every device will fail, and the time to failure may be surprisingly short or unusually durable or as expected Good luck & thank you 14