Part I - Installation

Similar documents
Part I - Installation

Part I -Installation Tools Needed Screwdriver/Adjustable Wrench to 1-1/2 MOUNTING

120 Series Explosion-Proof Pressure and Differential Pressure Switches

Part I -Installation Tools Needed Screwdriver/Adjustable Wrench to 1-1/2 MOUNTING

J21K Series DIFFERENTIAL PRESSURE SWITCH. features

800 Series. 800 Series INDICATING TEMPERATURE CONTROLS AND THERMOMETERS FEATURES

PRESSURE, VACUUM AND TEMPERATURE

55 Series. 55 Series REMOTE MOUNTING TEMPERATURE SWITCH AND CONTROL FEATURES. Single or Dual 15 A Switch Output. Panel or Surface Mount

PRESSURE, VACUUM, DIFFERENTIAL PRESSURE, AND TEMPERATURE SWITCHES

Operating Instructions

Installation and Operation Manual

Operating Instructions

REMOTE MOUNTING TEMPERATURE SWITCH AND CONTROL

55 Series Series REMOTE MOUNTING TEMPERATURE SWITCH AND CONTROL. features. Single or Dual 15 A Switch Output. Panel or Surface Mount

W Series. W Series HIGH PURITY PRESSURE SWITCHES FOR CLEAN GAS APPLICATIONS FEATURES

Electro-Pneumatic Converter YT-940 SERIES

Index Table. Model 794. Installation, Operating and Maintenance Instructions

55 Series Series REMOTE MOUNTING TEMPERATURE SWITCH AND CONTROL. features. Single or Dual 15 A Switch Output. Panel or Surface Mount

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Instruction Manual for Intrinsically Safe - Reed Switches

FLANGED TWO-PIECE BALL VALVES

FLANGED TWO-PIECE BALL VALVES

Pressure, Vacuum, Differential Pressure

RTD Temperature sensor TH11

GASGUARD VENT LINE3 Ammonia Sensor OPERATING & INSTALLATION MANUAL

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

ITS 300 & 500 SERIES POSITION MONITORING INSTALLATION AND OPERATION MANUAL

COOPER POWER SERIES. Under-oil arrester disconnector installation/operation instructions. OEM Equipment MN800010EN

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

Operating Instructions

GAS FUEL VALVE FORM AGV5 OM 8-03

G92 Series BASOTROL Automatic Pilot Gas Valve

NOVALYNX CORPORATION MODEL WEATHER STATION INSTRUCTION MANUAL

100C Air Compressor Kit

GG-VL2-NH3 AMMONIA VENT LINE SENSOR. Installation and Operation Manual

453 Series Steam Heated Vaporizing Regulator

CSA Sample Draw Aspirator Adapter Operator s Manual

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

200 PSI COMPRESSORS - MODEL NUMBERS

DISASSEMBLING & REASSEMBLING CARTRIDGE INSTALLING SEATPOST ON BIKE

SPECIFICATIONS ATTENTION

Pressure Dump Valve Service Kit for Series 2300 Units

INSTRUCTION MANUAL NI-281WE

COOPER POWER SERIES. Manual or Hostick Operable, Padlockable 150 A Tap-Changer Switch Installation Instructions. Tap-Changer Switch MN800015EN

EXPLOSION - PROOF PRESSURE TRANSMITTER

Installation, Operation and Maintenance Manual

INSTALLATION / OPERATION / MAINTENANCE INSTRUCTION

Models: C62/63/64-A/D

Powers Controls RC 195 Single Input Receiver-Controller

FLANGED MULTI-PORT BALL VALVES

! Warning, refer to accompanying documents.

200 A, 15 and 25 kv class loadbreak bushing insert installation instructions

COOPER POWER SERIES. 50 A 2:1 series multiple (dual voltage) switch cap/wrench, lever or hotstick operable handles installation instructions

BUTTERFLY VALVES Series 800

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

PRESSURE, VACUUM AND TEMPERATURE

RC 195 Receiver-Controller

Series 101/121 Differential Pressure Switches

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

VG5 Supplementary instructions

COOPER POWER SERIES. QD8 Quik-Drive tap-changer VR or VL reversing switch stationary contact assembly kit number A48 installation instructions

Sanitary RTD Temperature sensor TH17. Measuring System Sanitary RTD assembly with connection head TH17 for food and dairy applications.

Installation, Operation and Maintenance Manual. TSV Temperature Shut-off Valve SPD Rev. 6 10/07

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

Types and approvals. Page 1/6. Data Sheet

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

Pressure Dump Valve Service Kit for Series 3000 Units

COOPER POWER SERIES. 600 A 15, 25 and 35 kv class bushing adapter installation instructions. Deadbreak Apparatus Connectors MN650058EN

Installation, Operation & Maintenance Manual

Model 130M Pneumatic Controller

Installation, Operation & Maintenance Instruction. Models: Pulsa, Pulsar, PulsaPro. PULSAlarm LEAK DETECTION

IMPORTANT SAFETY INSTRUCTIONS

Operating Instructions for BAIR22-6 AIR-POWERED CRIMPING TOOL

Temperature gauge Installation Guide

QPL... Pressure Switches. Siemens Building Technologies HVAC Products

OWNERS MANUAL. Model Shown with optional Primary Mooring Cleats. Portable Mooring System SAFETY OPERATION MAINTENANCE PARTS

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

MODEL NUMBER: P PORTABLE COMPRESSOR

MODEL 154XST INSTALLATION AND SERVICE INSTRUCTIONS FOR MODEL 154XST STROBE LIGHT FOR USE IN HARSH ENVIRONMENTS/ HAZARDOUS LOCATIONS

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

J21K Series DIFFERENTIAL PRESSURE SWITCH. features

MODEL 840 AIR HYDRAULIC PUMP INSTRUCTION

Powers Controls RC 195 Multiple Input Receiver- Controller

Section 3- Repair and Calibration Procedures

INSTRUCTION MANUAL COMPACT PRESS. SWITCHES SERIES PCS & PCA

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

Armored Gauge O S & Y Bolted Bonnet Valves Series BB-100

Model PSI Compressor with 3-Gallon Air Tank 12VDC

GM-7000 Series CE Approved Gas Control Valve

400C & 450C DUAL PERFORMANCE VALUE PACKS

Model 106 DPI "Micro-switch" Installation and Operating Instructions

1 DRIVE INDUSTRIAL IMPACT WRENCH

OPERATING AND MAINTENANCE MANUAL

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Transcription:

120 Series Explosion-Proof Temperature and Indicating Temperature Switches and Controls Local Mount Types B121, B122, C120 Remote Mount Types E121, E122, F120; 820E, 822E UNITED ELECTRIC CONTROLS Installation and Maintenance Instructions Please read all instructional literature carefully and thoroughly before starting. Refer to the final page for the listing of Recommended Practices, Liabilities and Warranties. GENERAL Misuse of this device may cause explosion and personal injury. These instructions must be thoroughly read and understood before device is installed. This device is suitable for use in Class I, Division 1, Groups B, C and D; Class II, Division 1, Groups E, f and G; class III; or non-hazardous locations only. enclosure type 4x, 7 & 9. The device has been certified in accordance with the applicable requirements of the following standards: IEC 60079-0, 6 th edition, Revision Date 2013/12 IEC 60079-1, 7 th Edition, Revision Date 2014/06 IEC 60079-1, 6 th Edition, Issue Date 2007/04 IEC 60079-31, 2 nd Edition, Issue Date 2013/11 EN 60079-0:2012+A11:2013 EN 60079-1:2007 EN 60079-31:2014 This device is atex certified for equipment category 2. Suitable for appropriate use in gas zone 1 & dust zone 21 applications. DEMKO 09 ATEX 0815573X 0539 IECEx UL 03.0001X II 2 G Ex db IIC T6 Gb II 2 D Ex tb IIIC T85 C Db IP66-40 C Tamb. + 75 C To prevent ignition of hazardous atmospheres, disconnect supply circuits before opening. keep cover tight while circuits are energized. Maximum Temperature* stated in literature and on nameplate must never be exceeded, even by surges in the system. Occasional operation of unit up to max. temperature is acceptable (e.g., start-up, testing). Continuous operation should be restricted to the designated adjustable range. *Maximum Temperature - the highest temperature to which a sensing element may be occasionally operated without adversely affecting set point calibration and repeatability. This device does not have any field replaceable parts. Any substitution of components may impair suitability for Class I, Division 1. The 120 Series temperature switch utilizes either a liquid filled sensing stem (immersion stem, direct mounting) or liquid filled sensing bulb (bulb & capillary, remote mounting) to detect a temperature change. The response at a pre-determined set point(s), actuates a SPDT, dual SPDT, or DPDT snapacting micro switch(es), converting the temperature signal into an electrical signal. Control set point(s) may be varied by turning the adjustment hex (C120, F120) or the external knob(s) and pointer(s) (B121, B122, E121, E122,820E, 822E) according to the procedures outlined (See Part II - Adjustments) Please refer to the product bulletins for product specifications. Product bulletin may be found at. UE declarations and third party issued certifications are available for download at /prod_approval. Date code format on nameplate is YYWW for year and week. Part I - Installation TOOLS NEEDED Screwdriver/Adjustable Wrench to 1 1/2 MOUNTING to prevent electrostatic discharge, wipe down cover and enclosure of any dust build up before removing cover. Install device where shock, vibration and temperature fluctuations are minimal. do not mount device in ambient temperatures that exceed the limits on the nameplate for the appropriate area mount device to prevent moisture from entering the enclosure. it is imperative to use properly rated explosion-proof sealing fittings for electrical wire entry. to prevent ignition of hazardous atmospheres, seal conduit runs within 18 inches of enclosure TYPES C120, F120, 820E AND 822E ARE PROVIDED WITH TWO 3/4 NPT ELECTRICAL CONDUIT OPENINGS, EITHER OF WHICH OR BOTH CAN BE USED DURING INSTALLATION. A 3/4 EXPLOSION PROOF PLUG* IS PROVIDED FOR PROPERLY plugging THE UNUSED CONDUIT OPENING. THE EXPLOSION PROOF PLUG MUST BE PROPERLY installed. *Plug is approved explosion-proof with the product as a full assembly and does not carry individual markings. Do not knockout any plugs on Explosion-proof types 820E or 822E

the connection of the device shall be made by cable entries or a stopping box suitable for the conditions of use and correctly installed, and certified by type of explosion protection - flameproof enclosure d. always hold a wrench on the temperature housing hex when mounting the device. do not tighten by turning the enclosure as this will damage sensor and weaken solder and welded joints. vertical mounting (temperature probe facing down, see figure 2) is recommended; however device can be mounted in any orientation with adherence to previous warnings and exceptions below. Remote mount types E121, E122 & F120 temperature devices may be mounted vertically (temperature assembly facing down) or horizontally. The conduit connection must be properly sealed (potted) for horizontal installation. Device may be surface mounted via the four 1/4 screw holes on the enclosure or mounting bracket. It can also be mounted directly to a rigid pipe using a thermowell. Device with Breather Drain (Option M450) Types C120, F120 Mount with breather drain facing down (See Figure 1). The conduit connection must be properly sealed (potted) for this type of installation. Types B121, B122, E121 & E122 Mount in vertical position with temperature assembly and breather drain facing down (See Figure 2). Mounting Bulb and Capillary Fully immerse the bulb and 6 of capillary in the control zone. For best control it is generally desirable to place the bulb close to the heating or cooling source in order to sense temperature fluctuations quickly. Be sure to locate the bulb so it will not be exposed to temperature beyond the device range limits. Avoid bending or coiling the capillary tube tighter than 1/2 radius. Exercise caution when making bends near the capillary ends. If a separable well or union connector is used follow separate instructions included with them. WIRING disconnect all supply circuits before wiring device. wire device in accordance with local and national electrical codes. maximum recommended wire size is 14 awg and recommended tightening torque for field wiring terminals is 7 to 17 in-lbs Electrical ratings stated in literature and on nameplate must not be exceeded overload on a switch can cause failure on the first cycle. FIELD WIRING must be rated 90 C MINIMUM. FOR AMBIENT TEMPERATURES BELOW -10 C, USE SUITABLE FIELD WIRING. The external grounding terminal is not to be used as the primary equipment grounding terminal. The internal grounding terminal shall be used as the primary equipment grounding means and the external grounding terminal is only for a supplemental (secondary) grounding connection where local authorities permit or require such a connection. To prevent seizure of enclosure cover, DO NOT remove lubricant. Threads should also be free of dirt, etc. Remove cover and wire device (See Figure 4). Wire directly to the terminal block. An internal grounding terminal is located near the right-hand conduit opening. Replace cover and hand tighten to fully engage cover O-ring. Figure 1: Types C120, F120 Figure 2: Types B121, B122, E121, E122 820E and 822E type units must be surface mounted. Drill mounting holes per Figure 3. If a seal fitting is required, install the nipple and the seal fitting prior to surface mounting the controller. Clearance for 1/4 screw (4) places Figure 3: 820E, 822E Mounting

TYPES B121, C120, E121, F120, 820E SPDT TYPES B122, E122, E122P ORN YEL RED 2SPDT Types B122 and E122 Individual switches may be set together or separately by up to 100% of range. The front (low) switch should never be set higher than the rear (high) microswitch. Turning external knobs will increase or decrease each switch setting independently (see figure 6). Figure 4 Use 90 C copper conductors only. Recommended tightening torque for field wiring terminals is 7-17 in-lbs. Part II - Adjustments TOOLS NEEDED 3/16 Open End Wrench (2) 1/4 Open End Wrench 5/64 Allen Wrench 5/16 Open End Wrench (2 required for 822E only) AFTER COMPLETING ADJUSTMENTS ON ALL 120 SERIES, BE SURE TO RE-INSTALL ADJUSTMENT COVER. DO NOT OVER TIGHTEN COVER SCREWS. For set point adjustment and recalibration, connect device to a calibrated temperature source and stabilize. Types C120, F120 Remove Cover. Adjust set point by holding plunger with 3/16 open end wrench and turning the calibrating screw with another 3/16 open end wrench (see figure 5). Turn clockwise to increase setting or counterclockwise to decrease setting. Figure 5 1 2 Plunger ALSO FOR OPTION 1180 OPTION 1010, 1190, 1195 (FOR TYPE B121, C120, E121, F120 ONLY) RED YEL. ORN. 1 2 1 DPDT 2 Plunger Types B121 and E121 Remove adjustment cover. Adjust set point by turning external knob and pointer to desired setting on scale (see figure 6). BLK VLT TYPE 822E #1 #2 BLU NOTE REVERSE WIRING OF LOW SWITCH BLK BLU VLT RED ORN YEL NC NO COM NC NO COM SWT#2 SWT#1 Figure 6 External knob and pointer adjustment Indicating Temperature Switch Types 820E & 822E NOTE: Prior to making any device adjustment, the cover and adjustment knob should be removed. When adjustment is completed, all applicable parts should be replaced. Type 820E Move the set point Adjustment Pointer up scale beyond the brown Indicating Pointer. This permits checking the set point by moving the lever arm upward with a finger or tool simulating thermal assembly movement. Connect test lights to indicate switch operation or listen for the switch to click. Loosen adjustment A and move the Adjustment Pointer until it agrees with the Indicating Pointer (see Figure 7). When the switch clicks re-tighten the screw. Type 822E NOTE: Type 822E has a single knob and pointer for both switches. Both switches are standardly, factory set together within 5% of the dial range. Turning the knob positions both switches simultaneously, maintaining a constant separation between them. Remove the explosion-proof die-cast cover to permit access to the switches. Move the Adjustment Pointer up scale beyond the Indicating Pointer by an amount greater than the difference between the switch settings by moving the actuating lever upward with a finger or a tool simulating thermal assembly movement (see Figure 7). Connect test lights to indicate switch operation or listen for the individual switch clicks. The set point of switch #1 is determined by the red Adjustment Pointer. The set point of switch #2 may be adjusted by up to 25% of the range span below the switch #1 set point by turning adjustment D in (clockwise). See back page for 822E dual switch adjustment. The set point of switch #2 should not be above that of switch #1. To align switch #1 to the Adjustment Pointer, loosen adjustment A and set the Adjustment Pointer to the scale, then re-tighten adjustment A (see Figure 7). Note: Indicating Pointer Deflection (820E, 822E): The indicating pointers will read slightly low when the bulb temperature is 15 above the controller setting. This deflection is normal and repeatable (approximately 0.5% of scale range on single switch models) and is due to the transference of the switching mechanism load to the thermal system. It can be measured by moving the setting pointer from the high to the low end of the scale and observing the resultant indicating pointer deflection. Note: Indicating Pointer Adjustment (820E, 822E): Use an accurate test thermometer such as a thermocouple with its probe mounted directly to the center of the sensing bulb. Before making any adjustments, allow process temperature to stabilize; i.e., successive on-off cycles repeated.

zone hazardous locations flameproof gap and joint details 120 s Activation Plunger to adjustment screw hole gap joints: 1.140in/28.96mm min length by 0.0039in/0.099mm max annular gap Plunger Guide to enclosure through threaded joints: minimum 8 ½ fully engaged threads Figure 7: Indicating Enclosure Internals Correct any difference between the Indicating Pointer and the test thermometer by holding the compensator with a 5/16 wrench while turning the zero adjustment C on the thermal assembly with a second 5/16 wrench (see Figure 7) until the brown Indicating Pointer reads the same as the test thermometer. Turning clockwise lowers indicated reading. Compare the process temperature with the set point Adjustment Pointer. Loosen adjustment screw A to align set point Adjustment Pointer with the Indicating Pointer. Re-tighten screw A. Correction of Capillary (820E, 822E) If the length of capillary immersed in the process differs from the amount immersed (6, see Mounting Bulb & Capillary in Part I - Installation) at the factory calibration bath, a calibration shift will occur. The error may be corrected as follows: Move set pointer to the highest temperature setting. Note indicating scale reading with the head and sensor at room temperature. Loosen the two thermal assembly mounting screws. Re-position the housing index against the calibration on the instrument case (or skeleton casting) at a rate of 1 division line per capillary length listed in Figure 8. Move to the left if capillary is to be added to the process, or to the right if capillary is to be removed from process. Cover to enclosure through threaded joints: minimum 7 ½ fully engaged threads 121 s & 122 s Activation Plunger to enclosure through hole gap joints: 1.000in/25.40mm min length by 0.0030in/0.076mm max annular gap Adjustment shaft to shaft through hole gap joints: 1.050in/26.67mm min. length by 0.0035in/0.089mm max. annular gap Cover to enclosure through threaded joints: minimum 7 ½ fully engaged threads Manual Reset Option 1530 (120 s,121 s) Reset pivot to pivot guide through hole gap joints: 1.118in/28.40mm min. length by 0.0036in/0.091mm max annular gap Reset guide to enclosure through threaded joints: 8 fully engaged threads Model Number Range Cap Length/ Division* 1-180 to 120 F 2 ft 2-125 to 350 F 1 1 /2 ft 3-125 to 500 F 1 ft 4-40 to 120 F 4 ft 5-40 to 180 F 3 ft 6 0 to 250 F 2 1/2 ft 7 0 to 400 F 2 ft 8 50 to 650 F 2 ft *Added to or taken away from the process Figure 8

Dimensions (Dimensional drawings for all models may be found at.) Internal Set Point Adjustment, Types C120, F120 External Set Point Adjustment, Types B121, B122, E121, E122 Dimension A Model Inches mm NPT 120 9.12 231,4 Immersion stem 121 8.97 227,4 Immersion stem 1BS-8BS 8.47 214,8 Bulb & capillary Dimension A Model Inches mm NPT 120,121 (B121) 10.0 254,0 Immersion stem 120(B122) 10.0 254,0 Immersion Stem 121(B122) 9.84 250,0 Immersion Stem 2BS-8BS 9.31 236,6 Bulb & capillary 13272, 13322 10.0 254,0 Immersion stem (Freeze Protection) 13273, 13321 9.31 236,6 Bulb & capillary (Heat Tracing) Type 822E dual switch Type 820E single switch GROUND SCREW 7" [177.8mm] 3-1/2 [88.9mm] 6-3/8 [161.9mm] 3-3/16 [81.0mm] 4-11/16 [119.3mm] 1-11/16 [43.2mm] 1-3/16 [30.2mm] 7/8 [22.2mm] 3/4 NPT E/C PLUGGED 14-11/16 [373.1mm] 9" [228.6mm] SET POINT INDICATING POINTER (RED) BLK BLU VLT RED ORN YEL SWT #2 SWT #1 5/64 (2mm) SOCKET COVER-LOCK SCREW ADJUSTMENT D 3/4 NPT E/C BOTH SIDES TEMPERATURE INDICATING POINTER (BLACK) CLEARANCE FOR 1/4 SCREW 4 MT'G HOLES 3/8 [9.5mm] SET POINT ADJUSTMENT "A" KNOB 2-1/4 [57.5mm] Dimension A Model Inches mm 2BS 2.44 62,0 3BS 2.13 54.0 4BS 6.75 171,5 5BS 5 127,0 6BS 4.5 114,3 7BS 3 76,2 8BS 3.25 82,6 BULB 1-17/32 [38.9mm] Temperature Sensors Type E121, E122, F120 Models 2BS-8BS Remote Mount Temperature Assembly Type B121, B122, C120 Models 120-121 Direct Mount Temperature Assembly Ø3/8 [9.5mm] B* ** *use dimension b for separable well installations. Ø5/32 [REF] Remote Bulb **Except model 13273, 13321 bulb OD is Ø1/4 (6.35mm) 3/16 (REF) Dimension B Model Inches mm 2BS/BSA 2.63 66,7 3BS 2.13 54,1 4BS 6.75 171,5 5BS 5.00 127,0 6BS 4.50 114,3 7BS 3.00 76,2 8BS 3.25 82,6 13273 9.51 241,5 13321 9.51 241,5

RECOMMENDED PRACTICES AND WARNINGS United Electric Controls Company recommends careful consideration of the following factors when specifying and installing UE pressure and temperature units. Before installing a unit, the Installation and Maintenance instructions provided with unit must be read and understood. To avoid damaging unit, proof pressure and maximum temperature limits stated in literature and on nameplates must never be exceeded, even by surges in the system. Operation of the unit up to maximum pressure or temperature is acceptable on a limited basis (e.g., start-up, testing) but continuous operation must be restricted to the designated adjustable range. Excessive cycling at maximum pressure or temperature limits could reduce sensor life. A back-up unit is necessary for applications where damage to a primary unit could endanger life, limb or property. A high or low limit switch is necessary for applications where a dangerous runaway condition could result. The adjustable range must be selected so that incorrect, inadvertent or malicious setting at any range point cannot result in an unsafe system condition. Install unit where shock, vibration and ambient temperature fluctuations will not damage unit or affect operation. Orient unit so that moisture does not enter the enclosure via the electrical connection. When appropriate, this entry point should be sealed to prevent moisture entry. Unit must not be altered or modified after shipment. Consult UE if modification is necessary. Monitor operation to observe warning signs of possible damage to unit, such as drift in set point or faulty display. Check unit immediately. Preventative maintenance and periodic testing is necessary for critical applications where damage could endanger property or personnel. For all applications, a factory set unit should be tested before use. Electrical ratings stated in literature and on nameplate must not be exceeded. Overload on a switch can cause damage, even on the first cycle. Wire unit according to local and national electrical codes, using wire size recommended in installation sheet. Do not mount unit in ambient temp. exceeding published limits. LIMITED WARRANTY Seller warrants that the product hereby purchased is, upon delivery, free from defects in material and workmanship and that any such product which is found to be defective in such workmanship or material will be repaired or replaced by Seller (Ex-works, Factory, Watertown, Massachusetts. INCOTERMS); provided, however, that this warranty applies only to equipment found to be so defective within a period of 24 months from the date of manufacture by the Seller. Seller shall not be obligated under this warranty for alleged defects which examination discloses are due to tampering, misuse, neglect, improper storage, and in any case where products are disassembled by anyone other than authorized Seller s representatives. EXCEPT FOR THE LIMITED WARRANTY OF REPAIR AND REPLACEMENT STATED ABOVE, SELLER DISCLAIMS ALL WARRANTIES WHATSOEVER WITH RESPECT TO THE PRODUCT, INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. Limitation OF Seller s Liability Seller s liability to Buyer for any loss or claim, including liability incurred in connection with (i) breach of any warranty whatsoever, expressed or implied, (ii) a breach of contract, (iii) a negligent act or acts (or negligent failure to act) committed by Seller, or (iv) an act for which strict liability will be inputted to seller, is limited to the limited warranty of repair and/or replacement as so stated in our warranty of product. In no event shall the Seller be liable for any special, indirect, consequential or other damages of a like general nature, including, without limitation, loss of profits or production, or loss or expenses of any nature incurred by the buyer or any third party. UE specifications subject to change without notice. UNITED ELECTRIC CONTROLS 180 Dexter Avenue, P.O. Box 9143 Watertown, MA 02471-9143 USA Telephone: 617 926-1000 Fax: 617 926-2568 http:// CP12115000